| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Bd.A.1 Page Number 259 |
| 2 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof 50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthe bedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstrutting etc.complete.(Liftupto1.50m)ByMechanical Means Bd.A.2 Page Number 259 |
| 3 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steelcentering,formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredand curingcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Typemixer/concreteBatchmixplant(Panmixer)etc.complete. Withfineaggregate(CrushedsandVSI Grade) Bd. E. 1 Page Number 287 |
| 4 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalfor R.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsand steel stanchionsetc. including bailing out water,Steelcentering formwork, laying/pumping cover blocks, compaction and curingrougheningthesurfaceifspecialfinishistobeprovided(Excluding reinforcementandstructuralsteel)etc.complete,withfullyautomaticmicroprocessorbasedPLCwith SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.3 Page Number 298 and B.7, Page Number38 |
| 5 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumping,compactionfinishing the formedsurfaceswithcement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.5 Page Number 300 and B.7, Page.Number 38 |
| 6 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping,compactionandroughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) Bd.F.6 Page Number 300 and B.7, Page Number38 |
| 7 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.8 Page Number 302 and B.7, Page Number38 |
| 8 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) Bd.F.9 Page Number 303 and B.7, Page Number38 |
| 9 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings andschedules.including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Bd.F.17, Page Number 306 |
| 10 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:6 infoundationsandplinthofinnerwalls/inplinthexternalwallsincludingbailingoutwatermanually, striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete. Bd.G. 1 Page Number 313 |
| 11 | Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.layersincluding watering and compacting etc. complete. Bd.A.10 Page Number 262 |
| 12 | Fillinginplinthandfloorswithcontractors material/broughtfromoutsideandapprovedbyEngineer incharge inlayersof15cm to20cmincludingwateringandcompactionetc.complete. Bd.A.11 Page Number 263 |
| 13 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6 insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete Bd.G.5 Page Number 315 |
| 14 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop ironstrips25mm X1.6mm placed ateverythirdcourse,properlybentandbondedatendsscaffolding, racking out joints and watering etc. complete. Bd.G.7 Page Number 316 |
| 15 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. As directed by Engineer in charge. |
| 16 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 17 | Providing internal cement plaster 20mm thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete |
| 18 | Providing and fixing steel frame door of angle 50 x 50 x 6 mm with mild steel bars 16 mm dia. horizontally at 10mm c/c for ventilator portion including iron hold fast boxes for fixing shutters including welding, finishing, painting etc. complete. |
| 19 | Providing and fixing steel window C.R.C. sheet as per I.S. 1513 : 1986. gauge sect. 65 x 40 x 25 mm shutter single sheet of 24 gauge single leaf joinedby fusion welding at appropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first andlastribshouldbe60mmawayfrom verticaledgeoftheshutter.theshuttershallbe welded, with angle to from the periphery of the shutter. At the center of the frame there shall beangleweldedtobifurcatetheframeintosegmentswithtwoleaf shuttersquare12mm square guard bars at 120 mm center with all accessories As directed by Engineer in charge. |
| 20 | Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hot dip zinc coating including fabricating glazing with plain / obscured glass panes 5 mm thick and approved type and quality and iron oxidized fixtures and fa |
| 21 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary,preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. c |
| 22 | Providing andapplying three coatsof waterproof cementpaint ofapprovedmanufacture andofapproved colourto newplasteredsurfacesincludingscaffoldingifnecessary,cleaningand preparingthesurface, watering for two days etc. complete. |
| 23 | Providing and applying two coats of lead/zinc base oil paint/ bituminous paint of approved colour and shade to new wood work and fiber boards including preparing the surface, knotting, scaffolding if necessary, excluding primer coat etc. complete. |
| 24 | Providing and fixing coloured glazed earthenware Wash Hand Basin of 45 cm x 30 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe |
| 25 | Providing and laying for 150 mm dia salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete. |
| 26 | Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. |
| 27 | Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its |
| 28 | Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclus |
| 29 | Providing and laying ceramic tiles ofhaving size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour c |
| 30 | Providing and laying ceramic tiles of having size 30 cm. x 30 cm. and confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling wihte/colour cement slurry cleaning curing etc |
| 31 | Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. |
| 32 | Providing and fixing on walls/ ceiling/ floors 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 1.93 kg/meter with necessary fitting remaking good the demolished portion and applying primer of anti-corrosive oil paint, 2 coats I |
| 33 | Providing and fixing black kadappa stone as shelves 25mm. thick machine polished, extending the polish upto 20 cm width on lowerside, rounding corners, laying in position jointing with bedding cement mortar 1:4 proportion curing etc etc. complete. |
| 34 | ROYALTY CHARGES :- Supply of Rubble, Murum, Soil, 60mm./40mm. metal (Hand broken), royalty charges are not included in the rates.[As per Govt. of Maharashtra, Revenue and Forest Departments Gazette No.67 Dt.15 May,2015. States that the royalty charges ofRs.141.34/Cu.M. ) are considered. The surcharge levied on Royalty shall also be payable to the contractor. ROYALTY CHARGES FOR SAND |
| 35 | ROYALTY CHARGES FOR OTHER MINERALS |
| 36 | Laboratory testing charges are not considered in the Rate Abstracts. Where ever required separate item shall be taken in the estimate for material testing charges, on the basis of testing frequency and charges fixed by Vigilance & Quality Control Circle, for the current year and shall form part of tender.testing of material by Quality control and certified quality must be use by contractor. CONCRETE Compressive Strength of C. C. Cube (Set of 3 Cubes) |
| 37 | PART II- ADD 12% GST |
| 38 | 1% FOR LABOUR INSURANCE |