Repairs/Replacement And Maintenance Of Sewage Treatment Plant, Fire Fighting System And Central Acs/Cassettes Type Acs And Ahu Units And Connected Allied Works At Cdm Secunderabad Under Age E/M No 1 Of Ge (Utility) Secunderabad Repairs/Replacement And M, SECUNDERABAD-Telangana

Military Engineer Services-MES has published Repairs/Replacement And Maintenance Of Sewage Treatment Plant, Fire Fighting System And Central Acs/Cassettes Type Acs And Ahu Units And Connected Allied Works At Cdm Secunderabad Under Age E/M No 1 Of Ge (Utility) Secunderabad Repairs/Replacement And M. Submission Date for this Tender is 13-12-2021. Fire Fighting Consumable Tenders in SECUNDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

29938930
Corrigendum : Repairs/Replacement And Maintenance Of Sewage Treatment Plant, Fire Fighting System And Central Acs/Cassettes Type Acs And Ahu Units And Connected Allied Works At Cdm Secunderabad Under Age E/M No 1 Of Ge (Utility) Secunderabad Repairs/Replacement And M
Open Tender
Indian
Telangana
SECUNDERABAD
13-12-2021

Tender Details

Repairs/Replacement And Maintenance Of Sewage Treatment Plant, Fire Fighting System And Central Acs/Cassettes Type Acs And Ahu Units And Connected Allied Works At Cdm Secunderabad Under Age E/M No 1 Of Ge (Utility) Secunderabad Repairs/Replacement And Maintenance Of Sewage Treatment Plant, Fire Fighting System And Central Acs/Cassettes Type Acs And Ahu Units And Connected Allied Works At Cdm Secunderabad Under Age E/M No 1 Of Ge (Utility) Secunderabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Dec-2021 Amendment Other 06-12-2021
2 06-Dec-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-12-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT & MAINTENANCE OF SEWAGE TREATMENT PLANT, FIRE FIGHTING SYSTEM AND CENTRAL ACs/ CASSETTES TYPE ACs & AHU UNITS AND CONNECTED ALLIED WORKS AT CDM SECUNDERABAD UNDER AGE E/MNO 1 OF GE (UTILITY)SECUNDERABAD
Sl. No. Item Description
1M&L for preventive maintenance and tesing of fire fighting system control panel consisting zone type microprocessor based panel, fire/smoke/flame detectors and connected to CO2 cylinder bank of two zones consisting of 06 cylinders in each zone of 125 kg each by creating artificial smoke/fire in the presence user/CDM and MES representative and resetting the system after testingat site and preparing the test result sheet complete all as specified and directed.
2M&L for preventive maintenance, tesing and attending complains of fire alarm system having wireless control panel consisting zone type microprocessor based panel,wireless photo electric fire/smoke detectors with artificial smoke/fire in the presence of user/CDM and MES representative including clearing the minute particles with air blower of smoke detectors and resetting the setting after testing in Library, SP block and Ashwamedha block complete all as specified and directed. Note: Testing should be done by Ceasefire/visonic company.
3M&L for filling of CO2 gas in 45 kg cylinders of CO2 bank including disconnecting the cylinders from manifold and refixing carefully with necessary teflon thread seal tape and hardware at site complete all as specified and directed.
4Supply and replacement of 1/4"" highly inflamable hose pipe assy of length 300mm (as per sample) and is connected to CO2 gas cylinder master valve to slave valve assy and approved ISI std and specified and directed.
5Supply and replacement of1/4"" highly inflamable hose pipe assy of length 500mm (as per sample) and is connected to CO2 gas cylinder master valve to header pipe and complete all as approved ISI std and specified and directed.
6Taking out and dismantling of U/s CO2 Master valve assembly from the cylinder and cleaning of all the dismantled parts of cyliner and replacethedamaged CO2 master valve complete with 24 solenoid and manual release leverwith newat site and testing the same on completion alll as specified and as directed.
7Taking out and dismantling of U/s CO2 slave valve assembly from the cylinder and cleaning of all the dismantled parts of cyliner and replacethedamaged CO2 slave valve complete with pneumatic actuator and manual leverwith newat site and testing the same on completion alll as specified and as directed.
8M&L 10Kg Standalone Suppression System- HFC236 fa ceiling mounted fire extiguisher clean agent stored pressure guage weight 14.8Kg, empty weight 4.8Kg can height 316MM, diameter 300MM, dischrage time less 10Secs, Auto dischrage mechanism on temperature rise applicable on class A,B,Cand electrically started fire, can construcrion: Deep drawn & CO2, mig welded valve construction forging & machining, internal coating of Can: Epoxy coating external coating of can: Epoxy polyster powder coating sheet metal thickness: 2.0MM helium leak detection tested, 5 Years warranty. Make: Product code CF-000770 OF CEASEFIRE or equivalent as approved by GE
9M&L 5Kg Standalone Suppression System- HFC236 fa ceiling mounted fire extiguisher clean agent stored pressure guage weight 7.7Kg, empty weight 2.7Kg can height 267MM, diameter 230MM, dischrage time less 10Secs, Auto dischrage mechanism on temperature rise applicable on class A,B,Cand electrically started fire, can construction: Deep drawn & CO2, mig welded valve construction forging & machining, internal coating of Can: Epoxy coating external coating of can: Epoxy polyster powder coating sheet metal thickness: 1.6MM helium leak detection tested, 5 Years warranty. Make: Product code CF-000771 of CEASEFIRE or equivalent as approved by GE
10Supply , Installation Commissioning and testing of wireless Panel : Operating frequency range : 868.15 MHz to 869.85 MHz maximum radiated power 5 dBm (3 MW) operting frequency chnnels : 7 communication range with translator or expander module, IP rating :42 dimensions : 85 mm * 85 mm weight (with out batteries) : 134 gms, primary power cell : CR123A (3V & 1.2Ah) secondary power cell : CR2032A (3V & 0.2Ah) Oprating Temperature: - 30 degree C to +55 degree C, maximum trolerated humidity (no condensing) : 95% RH Complete all as specified and directed .
11Supply, fixing and testing of wireless photo electric smoke detector comprising with following specification complete all as specified and directed. Specifications:- (i) Cover range : 50 Cubic meter to 100 Cubic meter (ii) Battery type : 3V CR 123A (iii) Battery expected life : 5 year (iv) Weight : 165 gram (v) Operating temperature : 10 degree C to 50 degree C (vi) Operating environment : Indoor (vii) Dimension : 120 mm x 58 mm
12S&F of suitable at site 3V CR123A Lithium Battery of wireless photo electric smoke detector with having life of 5 year, along with testing after fixing of detector incl taking down old Unsv battery complete all as specified and directed.Make : Panasonic as approved by GE
13Supply, installation, commissioning and testing ofsmoke detector oftype Photoelectric / Optical with base with self inbuilt intelligence and compared to EN-45 addressable type complete all as specified and directed. Make: Reliance/Zeco Wizmart/Notifier as approved by GE
14Supply, installation, commissioning and testing of Heat detector type Photoelectric / Optical with base with self inbuilt intelligence andcompared to EN-45 addressable type complete all as specified and directed. Make: Reliance/Visonic/Notifier as approved by GE
15Testing and Commissioning Pressure test the system with dry Nitrogen upto 300 PSI and rectifiying the leakages , pressure hold upto 300 PSI for 48 Hrs , Vaccumizing the system upto 500 micrones & commissioning the unit, test running etc as per requirements (Refrigerant gas shall be paid seperate)
16M&L for Cleaning/descaling of cooling coil fins of IT center AHU of 66TR capacity for oxides, dust and improving the heat transfer capacity by using 50% concentration HCL/H2SO4 cleaning acid and brushing all as directred by Engr-in-charge. Make: ACCEL as approved by GE
17M&L for Cleaning/descaling of cooling coil fins of Library AHU of 33TR capacity for oxides, dust and improving the heat transfer capacity by using 50% concentration HCL/H2SO4 cleaning acid and brushing all as directred by Engr-in-charge.
18M&L for Cleaning/descaling of cooling coil fins of Ductable ACs of 11 TR capacity for oxides, dust and improving the heat transfer capacity by using 50% concentration HCL/H2SO4 cleaning acid and brushing all as directred by Engr-in-charge
19Repairs of Indoor PCB Controls of 11 TR AC as specified and directed.
20S&F of New Controls with remote for 11 TR Ductable unit as specified and directed.Make:- HITACHI as approved by GE
21S&F of PCB of 11 TR HITACHI Outdoor unit as per requirement of site. Make:- HITACHI as approved by GE
22S&F of Electronic Thermostate including replaceing of U/S Old Thermostate as per requirement of site. Make:- HITACHI/VOLTAS as approved by GE
23S&F of liquid line filter 5/8 ae per requirement of site all as specified and directed
24Supply and Charging ofRefrigerant Gas R-410/407C or equivalnt in Froen/Mafron family in sealed cylinders all as directed by Engr-in-charge
25Supply and fill Compressor Oil Make : Sheetal (IOC) or equivalent as approved by GE
26Supply, fixing and commissioning Scroll Compressor of Capacity 11 TR with all its specification including removing of Old Unsv compressor as per requirement of site. Make:- HITACHI/VOLTAS as approved by GE
27M&L for Servicing of Compressor Suction and discharge Shut-off Valves by replacing Teflon washers and hard ware for proper functioning all as directed
28S&F for replacement of the following unsv items of LT panel board of the AC plant and air cooling system :
29MCCB 32 Amps, 3 phase 3 pole, 25 KA, 415 volts with fixed magnetic settings complete. Make : L&T type DNO-100C as approved by GE
30MCCB 63 Amps , 3 phase 3 pole, 25 KA, 415 volts with fixed magnetic settings complete. Make : L&T type DNO-100C as approved by GE
31Front Mounting Add-on aux. Contact Block MNX A2.Make :- L&Tor equivalent as approved by GE
32Power contactor 3 pole 25 amps 415 volts type ML-3.Make : Cat Part No 3TS3300 of SIEMENS or Equivalent as approved by GE.
33Power contactor 3 pole 25 amps 415 volts type ML-3.Make : Cat Part No LC1E2501M7 of SCHNEIDER or Equivalent as approved by GE.
34Over load relay 3 phase 440 volts 28 to 42 amps.Make : L&T type ML-3 as approved by GE
35MCCB 100 Amps , 3 phase 3 pole, 25 KA, 415 volts with fixed magnetic settings complete.Make : L&T type DNO-100C as approved by GE
36Rewiring of 11 TR outdoor unit fan motor as specified and directed.
37M&L for servicing and over hauling of 66/33 TR AHU Blower motor of 7.5 HP including varnishing the stator and replacing the worn out drive end/driven end bearings and greasing and reassembling and testing complete all as directed
38S&F for replacement of UNSV "V" belts suitable for 7.5 HP air blower motor size of "V" beltcomplete,all as specified and directed .
39M&L for servicing and overhauling of air curtain for prevention dust and conditioned air losses, single phase 220V 50 Hz, made out of MS/CRCA Sheet of minimum thickness 18 gauge finished with two coats of red oxide and final coat of synthetic enemell paint (oven backed) with MS/CRCA 18 gauge square perfoated suction grills alluminium alloy fans and single phase electric motor, nozzles etc, complete with fitting and accessories so as to produce 1-1.5 m/sec air velocity at floor level for door opening for size 70" x 78" complete all as specified and directed.
40S&F PVC insulated flexible stranded copper conductor of size 16 sqmm x 4 core complete all as specified and directed.Make :- Havells/ Polycab/KEI as approved by GE
41Repair/Maintenance, excluding spares but including regualr maintenance of the Sewage treatment plant of capacity 50 Cum/day installed at CDM Dhruva under AGE E/M No 1 including carrying out complete maintenance /servicing/ repairas requied of all the sub systems viz controlpanels, compressor blower, pump motors, lamella plant, filter press, filtration plant& sodium hyprochlorite dosing plant (with all the accessoires ) breakdown maintenance and replacement of unserviceable parts, re-fixing of old serviceableparts/new parts if any inclduing the following and all as specified and directed by Engineer-in-Charge
42Note :- (i)New parts if any shall be paid under separate items as supply only (ii) Unit rate quoted by tenderer isof checking of system monthly by technician and necessary servicing and repair job signed by JE /Engr-in-Charge (iii) Unit rate quoted by tenderer is of checking of system fortnightlyby Engineer and necessary servicingand repair job signed by JE /Engr-in-Charge (iv) In addition to above specific emergency complaints receiving telephonically from time to time shall be attended within 24 hrs after receiving the same (v) The scope of work includes the charges required for removing, repairing, refixing, carrying out electrical termination and fixing/installing testingcommissioning etc and all as directed (vi) The workhas to be carried through ion exchange company authorized representative.
43M&L for emptying and cleaning/removal of hold up sewage from and sludge from drains including cleaning of Bar Screen chamber of STP of capacity 50 Cum/Day all as specified and directed by Engr-in-Charge
44M&L for removal of sewage and garbage from oil grease chamber of STP capacity 50 Cum/Day with the help of sewage pump mounted on portable bowser complete all as specified and directed by Engr-in-charge
45M&L for removal of sewage and garbage from collection tank with the help of sewage pump mountedon portablebowser and replacementof air diffusers with unserviceable distribution pipe network of STP of capacity 50 Cum/Day all as specified and directed by Engr-in-Charge
46M&L for removal of sewage and garbade from Aeration tank ofSTP of capacity 50 CUM /day with the help of pump mounted on portable bowser/manual includingcleaning of distributionpiping networkcomplete all as specified and directed
47M&L for replacement of FMR Fluidized Bio-Media suitable for STP of capacity 50Cum /Day all as specified and directed by the Engr-in-Charge
48Supply of New clarifier plates suitable for STP of capacity 50 Cum/day incl taking down old unsv all as specified and directed by the Engr-in-charge
49Supply of New Micron Catridges along with Housing suitable for STP of capacity 50 Cum/day incl taking down old unsv all as specified and directed by the Engr-in-charge
50Rectification of UV system and supply of spare as per requirement all as specified and directed.
51Supply of Membrane diffuser suitable for STP of capacity 50 Cum/day incl taking down old unsv all as specified and directed by the Engr-in-charge
52M&L for removal of sewage and garbage from lamella clarifier including painting with one coat of red oxide and two coat of sysnthetic enamael paint and cleaning of fiver setting plated of lamella claffiercomplete all as specified and directed by Engr-in-Charge
53M&L for emptying cleaning of sand media filter including welding work etc complete all as specified and directed by Engr-in-Charge
54M&L for epoxy coating and sand media filter vesselinternally suitable forSTP of capacity 50 Cum per day complete all as specifiedand directed by Engr-in-Charge
55M&L for replacement of filter media of sand media filter unit as described by Ion Exchage precipitation including testing of the same complete all as specifiedand directed by Engr-in-Charge
56M&L for repalacement of existing gasket and fasterner of sand media filter unit including nut, bolt and washers all as specified and directed by Engr-in-Charge
57M&L for emptying cleaning of activated carbonunit including welding work etc complete all as specified and directed by Engr-in-Charge
58M&L for epoxy coating of activated carbon unit vessel internally suitable 50 CuM per day STP compelte all as specified and directed by Engr-in-Charge
59M&L for replacement of filter media of activated carbon unit suitable 50 Cum per day capacity STP precipitation includingtesting of the same complete all as specified and directed by Engr-in-Charge
60M&L for replacementof existing gasket and fasterner of active carbon unit including nut bolt and washers all as specified and as directed by Engr-in-Charge
61Dismantling the unserviceablepart of sewage treatment compressor blower and replace with new spare part including testing after completion all as specified and directed by Engr-in-Charge
62M&L for servicing and over hauling of 7.5 HP induction motor including varnishing the stator and replacing the worn out drive end/driven end bearings and greasing and reassembling and testing complete all as directed atSTP
63Supply only the following spares for repairs of pump set of 7.5/10 HP capacity:-
64Ball bearing
65Impellers
66PCV fan
67Gland rope
68M&L for servicing and over hauling of 2HP induction motor including varnishing the stator and replacing the worn out drive end/driven end bearings, greasing,reassembling and testing complete all as directed AT STP
69M&L for servicing and over hauling of 1 HP induction motor including varnishing the stator and replacing the worn out drive end/driven end bearings, greasing, reassembling and testing complete all as directed
70Supply only the following spares for repairs of Mono block pump set of 1.0/2.0 HP capacity:-
71Ball bearing
72Impellers
73PCV fan
74Gland rope
75M&L for servicing and over hauling of 5 HP Blower motor including varnishing the stator and replacing the worn out drive end/driven end bearings, greasing, reassembling and testing complete all as directed AT STP
76M&L for cleaning of sewage well including chocking of all incoming sewage line entering to sewage well for dewatering and desuldging of slurry of sewage pump
77M&L for De- watering sewager cleaning machine of cap 3000 ltrs and depositing in MCD main hole at distance of 1 Km
78M&L for Desludging of slurry using buckets and pulleys of depth total depth 7.5 mtr slurry average depth 2.5 mtr including depositing at a distance not exceeding 1000 mtr from starting point of sewager pump
79M&L for scrapping of walls of well including and removing of materials not exc 50 mtr from starting point all as directed
80M&L for de watering, De sludging and De silting of septic tanks, man holes, sludge chambers and the like by mannual or mechanical means depositing in tankers and disposal of the same at the placeexceeding distance of 2 KM and not exc 3 KM where directed and sprinkling of bleaching on the disposed material 3 KG per Cum. (the rate includes transportation, bleaching )
81Supply onlyWater treatment chemicalBio Clean Septic Powder available complete all as specified and directed
82Supply only Water treatment chemical sodium hypo Chloride consisting 14% chlorine content diluted ClNao, complete all as specified and directed.
83Supply only Water treatment chemical enzyme-2 (DAP consisting 18:46:0, 18% Nitrogen and water super phosphates 46% by minimum weight, packedin 50 Kg Polythene bagcomplete all as specified and directed.
84Supply only Activated Carbon Filter media (ACF), Grade IV-900, size of layeras complete all as specified and directed. Makes :Granular/Norit as approved by GE Note: ACF Media combination quality & quantity shall be as directed & recommended by OEM only.
85Supply only Activated sand Filtermedia (ASF), complete all as specified and directed. Note: ASF Media combination quality & quantity shall be as directed & recommended by OEM only. (a) Daily consumption quantity of each item viz, Chemical Bio Culture Bacteria solution, Sodium Hypochloride etc shall be submitted.Also daily consumption of all chemicalsshall be recorded in register and maintained at site. (b) The manufacturer shall comply and guarantee the authenticity of the product by providing Test Certificate with Hologram which will be provided by the Authrorised Distributor at the distribution point for each Batch of Product delivered on their letter head. (c) The manufacturer will affix its hologram on each and every drum/container/bag. If the said product is delivered without the said hologram and/or it is seen to be tampered, then the product can be discarded as spurious.
86M&F for MBBR fludised bio-media of vergin PPUV stablized material,cylindrical with external fins structure,black colour,22mm dia x 16mm height ,specific gravity 0.9 to 0.95 gms/sqcm all as specififed and as directed . Make: TP Aqua/Cool tech/Hydrotech as approved by GE
87M&L Bactria culture for STP for developing MLSS and control odor complete all as directed by Engr-in-Charge. Make: Organic plus or its techno commercial equivalent make as approved by GE
88Supply only TCCA 90% Chlorine (Trichloroisocyanuric Acid), effective content of chlorine % :>=90, Content of water %<= 0.5, PH Value of 1% Solution : 2.7 to 3.3, Granular Chlorine/Tblet in packing of 50 Kg complete all as specified and directed.
89Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying ofmains / Poles, stay, cables and the like not exc 10 sq m on plan and not exc 1.5 m in depth and getting out in Hard / Densesoil complete all as specified and directed.
90M&L for Supply, spread and filling approved river sand in cable trenches as cushioning of under ground cables including punning down of sand in layers complete all as specified and directed. Note:- Thickness of sand cushion after punning down will only be measured and paid.
91Supply and lay un-reinforced precast concrete cable cover block, class LV, Type Iflat size 250 x 150x 40 mm laid dry in trenches over under ground cablescomplete all as specified and directed.
92Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
93Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
94Supply & laying only XLPE insulated PVC sheathed armoured heavy duty LT UG electric cable with aluminium conductor 1100 volt grade laid in trenches / fixed on wall / poleof cross sectional area of cable 16 Sqmm, 4 core including taking down old unserviceable cables complete all as specified and directed.
95All as per item No 80 above but cross sectional area of cable 25 Sqmm, 3.5 core.
96Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long)including painting with two coats of aluminum paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) widecomplete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
97S&F in replacement of LED flood fitting of 120W pressure die cast aluminium body , IP66 on existing pole with provisioning of 2 runs of cable PVC insulated Multi core unsheathed 1100 volts grade 4 Sqmm multistranded with aluminium conductor from fitting to junction box including provision of necessary brakets for fixing of fitting complete all as specified and directed. Make :- BAJAJ/HAVELLS/PHILIPS as approved by GE
98S&F cable junction box thermoplastic body IP 66 , size 225mmx295mmx122mm suitable for helogen free and weather proof for out door installation with metric knockout for cable entry suitable for cable size 10-25 sqmm including 01 No SP MCB single pole of capacity 5 to 30 Amps 240 Volts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron with boltd all specified and as directed. Make: Hensil/Neptune/sintex as approved by GE
99S&F in repairs CI foot valve leather sheet type / flange type suitable for 80 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.
100S&F in repairs CI foot valve leather sheet type / flange type suitable for 50 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.
101S&F in repairs PVC foot valve leather sheet type / flange type suitable for 50 mm dia GI suction heavy duty includung replacement of nuts, bolts washers, gaskets and flanges etc. complete all as directed and specified by Engr-in-charge.
102Supply and laying of 3-layer PP-R Polypropylene random copolymer pipes SDR 7.4 & SDR 11 UV Stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches etc all as specified and directed of following sizes:-
10332 mm bore.
10440 mm bore.
10550 mm bore.
10675 mm bore.
107110 mm bore.
108S&F 32 mm PP-R Gate valves ( brass insert) as per requirement of the site complete all as specified and directed
109S&F 40 mm PP-R Gate valves ( brass insert) as per requirement of the site complete all as specified and directed
110S&F PVC pipes of pressure rating 6 kgf/cm2 laid in trenches complete all as specified and directed
11125 mm bore.
11240 mm bore.
113S&F 63 mm PVC pipes of pressure rating 4 kgf/cm2 laid in trenches complete all as specified and directed
114Supply and Fix 75 mm PVC pipes of pressure rating 4 kgf/cm2 laid in trenches complete all as specified and directed
115S&F in existing line 15 mm stop valve cast copper alloy, screwed down , high pressure , with crutch handle, screwed both ends for iron pipe or union and fixedcomplete all as specified and directed.
116S&F PP Ball Valve 40mm bore complete all as specified and directed.
117S&F PP Ball Valve 63mm bore complete all as specified and directed.
118S&F PVC Flush Valve 40mm bore complete all as specified and directed.
119S&F PVC Flush Valve 63mm bore complete all as specified and directed.
120M&L for emptying and cleaning/removal of hold up sewage from and sludge from rain water harvesting tanks including cleaning of gravel filter,Mesh chamber of Drip irrigation systemall as specified and directed by Engr-in-Charge
121M&L for servicing and over hauling of 3 HP Open well submersible pump set including varnishing the stator and replacing the worn out drive end/driven end bearings, greasing, reassembling and testing complete all as directed
122M&L for servicing of Solar water Heater 200 LPD HHC System including changing of gasket, minor spares part as per requirement on site complete all as specified and directed.
123Removing unserviceable and thermosate fixing the new one as requirement on site all as specified and directed.
124M&L for servicing of 20 KW Solar power plant ,invertor, DC wiring including minor Spare part upto Rs 1000 each after disconnection the DC/AC Cable and resetting the plant after testing complete all as specified and directed.
125S&F of Charge Controller unit (8 Amps or required on site) for Solar Light 28 Watt incl taking down old Unsv one complete all as specified and directed.
126S&F of Solar LED Street light 28 Watt incl taking down old unsv one complete all as specified and directed.