Operation With Comprehensive Maintenance Contract ( Cmc ) For Complete Fire Fighting Equipment And Fire Alarm System At Homi Bhabha Cancer Hospital Research Centre, Visakhapatnam, Andhra Pradesh - 530053. Operation With Comprehensive Maintenance, Andhra Pradesh, visakhapatnam, Aganampudi-Andhra Pradesh

Tata Memorial Centre has published Operation With Comprehensive Maintenance Contract ( Cmc ) For Complete Fire Fighting Equipment And Fire Alarm System At Homi Bhabha Cancer Hospital Research Centre, Visakhapatnam, Andhra Pradesh - 530053. Operation With Comprehensive Maintenance. Submission Date for this Tender is 04-12-2021. Fire Alarm Systems Tenders in Andhra Pradesh, visakhapatnam, Aganampudi Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29876249
Corrigendum : Operation With Comprehensive Maintenance Contract ( Cmc ) For Complete Fire Fighting Equipment And Fire Alarm System At Homi Bhabha Cancer Hospital Research Centre, Visakhapatnam, Andhra Pradesh - 530053. Operation With Comprehensive Maintenance
Open Tender
Indian
Andhra Pradesh
Andhra Pradesh, visakhapatnam, Aganampudi
04-12-2021

Tender Details

Operation With Comprehensive Maintenance Contract ( Cmc ) For Complete Fire Fighting Equipment And Fire Alarm System At Homi Bhabha Cancer Hospital Research Centre, Visakhapatnam, Andhra Pradesh - 530053. Operation With Comprehensive Maintenance Contract ( Cmc ) For Complete Fire Fighting Equipment And Fire Alarm System At Homi Bhabha Cancer Hospital Research Centre, Visakhapatnam, Andhra Pradesh - 530053.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Nov-2021 Online Pre-Bid Meeting Other 04-12-2021

Key Value

Document Fees
Refer document
EMD
INR 46000.0 /-
Tender Value
INR 23 Lakhs /-

BOQ Items

Name of Work: Operation with Comprehensive Maintenance Contract (CMC) for various Fire Fighting Equipment and Fire Alarm System at Homi Bhabha Cancer Hospital & Research Centre, Visakhapatnam, Andhra Pradesh - 530053.
Sl. No. Item Description
1Technician salaries:- Wages to be paid for 04 No"sSemi Skilled Technicians for 26 days inround the clock operation ( 04 No"s X 12 Months= 48) of pumps ,valves and also initial assistance in defect rectification subjected to fire fighting equipments. Total Monthly Charges Including ESIand EPFas promulgated by Govt.of India time to time.The contractor must pass on these monthly charges to workers, ESIC and EPFO and shall submit proof of electronic payments made to HBCH&RC,Vizag for further proessing.( Rates as per Ministry ofLabour and Welfare Office order dated23/04/2021)
2Supervisor Salaries:-Wages to be paid for 01 No. Skilled Technicianfor supervisiory duties of the technicians for 26 days in a month.Engineer will beSingle Point of contact for all defects and undertaking of Maitenence schedule as mentioned below.Total Monthly Charges Including ESIand EPFas promulgated by Govt.of India time to time .The contractor must pass on these monthly charges to workers, ESIC and EPFO and shall submit proof of electronic payments made to HBCH&RC,Vizag for further proessing.( Rates as per Ministry ofLabour and Welfare Office order dated23/04/2021)
3PUMP Unit of Diesel Engine Driven Pump:- Diesel engine drivencentrifugal Horizontal split case fire fighting diesel engine pump set having capacity of 2280 LPM at 88m head along with all accessories with CI casing, standard fitting, bronze impeller, Stainless Steel shaft, mechanical seal with water cooled heat exchanger diesel engine, having speed of 1500 rpm.CMC Including cleaning of strainers,replacement of gaskets,vibration pads if required,Greasing at greasing points,replacement of seals and arrest any leaks fromfittings and make operational for 24X7 operation in all respect.Replacement of faulty pressure gauges ,Vibration Pads when required.Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.PUMP MAKE KIRLOSKAR ,PUMP TYPE DSM 100/36,CENTRIFUGAL PUMP,PUMP NO. 1723017352 QA NO.D10318A548/200TOTAL HEAD-88M, DISCHARGE 136.800M3/HR ,PUMP INPUT -44.459 KW ,IMP DIA MM BR/ 365 SIZE & RPM100 X 125 & 1500MAT CODE43 ,RECOMMENDED PRIME MOVER RATING -127 HP
4ENGINE Unit of Diesel Engine Driven Pump :- Fuel pipelaid from diesel tank upto engine ,Exhaust piping cladding with 12 mm thick super ceramic fiber rope including fittings, clamps steel support bends and canopy at termination point of suitable dia for the engine as per manufacturers instruction shall be included. Supply of the charge of lubricants,fuel, distilled water for battery and other consumables related to Diesel Engine shall be included.CMC including Repair/Replacement of batteries,Strating Motor,Dynamo,Air & Lub Oil Filters,replacement of rubber hose/bellows, Exhaust bellows, Silencer , Belts,Jubliee Clips.Any other minor repairs in all respects to make the equipment operationally available 24X7.Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.Note :- CMC to be undertaken by authorised/OEM of the Engine.ENGINE TYPE6R1080T,RATING KW/HP93.47/127 HP,RPM 1500 ,RATING &STD ISO& 3046 GOVERNNG CLASS M2, ENGINE NO.6H.2410.10 / 1720022 ,(DISEL SPRIEYR )BOSCH F0002 A0Z 421 / PES6A95D320RS3559 ,BOSH SL NO. 75809688 ,BATTRIES MAKE EXIDE CARE BATTRIES QTY -02 NOS,ENGINE AIR CLEANER F6.504.01.0.00
5Main Fire fighting pump (Electrical driven ) COMPREHENSIVE MAINT CONTRACT includes: Motor driven Centrifugal Horizontal,split case Fire fighting pump set along with all accessories capacity of 2280 LPM at 88m head with CI casing, mechanical seal standard fittings, Stainless Steel shaft, bronze impeller, suitably rated electrical driven squirrel cage induction motor running at 1500 rpm (synchronous speed) with Class-F insulation, IP-55, suitable to operate 415 V +/- 10% 50 Hz +/- 3%, 3 phase AC supply, including supplying MS common base plate frame and foundation bolts, anti vibration pads complete.with coupling guard & all other accessories etc. CMC Including cleaning of strainers,replacement of gaskets,vibration pads if required,Greasing at greasing points,replacement of seals and arrest any leaks fromfittings and make operational for 24X7 operation in all respect.Replacement of faulty pressure gauges ,Vibration Pads when required.Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.PUMP MAKE : KIRLOSKAR,PUMP TYPE DSM/100/36, PUMP L CUPLING SW-276ø32 QA NO. D10318A548/100,TOTAL HEAD -88 M DISCHARGE,136.800 M3/HR,PUMP INPUT ,PUMP NO 44.303 ,1723017353IMP DIA MM BR/362,SIZE & RPM100 X 125 & 1480MAT CODE 43 RECOMMENDED PRIME MOVER RATING - 75 KW MOTOR MAKE CG APEX ,MACHINE NO. 75KE4, KW & HP -75.0 & 100.00 HP, VOLTS -415 +/- 10%, BRG DE / NDE 6318- C3 / 6318- C3 ,GREASE UNIREXN3IEC 60034-1 : IE2 , REF QLAM RELUB HRS20643, 5800 RPM & AMP1480 & 126ADELTAFRAME NO.280S EFF , 94.00%GREASE QTY / SHAFT 120 grams,HALF KEY BALANCED
6Fire fighting Jockey pump (Comprehensive Maint. Contract includes) :- Motor driven Centrifugal End suction topdischarge Jockey pump set for fire fighting system of capacity of 180 LPM at 88m head along with all accessories, mechanical seal, CI casing, Stainless Steel shaft, standard fittings, bronze impeller, electrical driven suitably rated squirrel cage induction motor with synchronous speed not exceeding 2950 rpm with Class-F insulation,IP-55 to operate at 415V+/- 10% 50 Hz+/- 3% 3 phase AC Supply, including supplying MS common base plate.CMC Including cleaning of strainers,replacement of gaskets,vibration pads if required,Greasing at greasing points,replacement of seals and arrest any leaks fromfittings and make operational for 24X7 operation in all respect.Replacement of faulty pressure gauges ,Vibration Pads when required.Any other minor repairs in all respects to make the equipment operationally available 24X7.Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included. PUMPS MAKE : KIRLOSKAR,PUMP TYPE CPHM 25/26 A ,PUMP NO. 1789317778,PUMP INPUT SIZE 7.840 KW 25×80mm ,TOTAL HEAD - 88m, DISCHARGE -10.800 M3/Hr,IAMP DIA MMBR/247/300 MAT CODE 43, PUMP RPM2926rpm,MOTORMAKE CG apex,KW & HP11.0 & 15.0 hp RPM 2925,VOLT /AMP415 ± 10 %/19A ,REF QKAM2607 BEARING DE/NDE ,6209-2Z/ 6209-2Z GREASE SHAFT IEC 60034-1E2half keybalanced , FRAME ND160 M,EFF& HZ 89.40% & 50 ± 5% PF & CONN DIAG0.88 & 302DUTY & IP,S1 & 55
7Terrace pumps (Comprehensive Maint. Contract includes) :- Motor driven centrifugal end suction pump top discharge set for fire fighting system of following capacities & head along with all accessories with CI casing, Stainless Steel shaft, standard fittings, bronze impeller, love joy coupling to the electrical driven TEFC, squirrel cage induction motor suitably rated, with synchronous speed not exceeding2950 rpm, class-F insulation, IP-55 rating, suitable to operate on 415 V + / - 10%, 50 Hz + /- 3% , 3 phase ACsupply .CMC Including cleaning of strainers,replacement of gaskets,vibration pads if required,Greasing at greasing points,replacement of seals and arrest any leaks fromfittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included. PUMP MAKEKIRLOSKAR BROTHERS LTD, PUMP TYPEDB40/16, PUMP L COUPLINGØ24/8/27.3 OA NO. D10209A509/200, TOTAL HEAD -35 M, DISCHARGE-27 M3/HR, PUMP INPUTPUMP NO40.085KW 10206180319IMP DIA MM, BR/173SIZE & RPM40 X 65 & 2885RPM, MAT CODE56,RECOMMENDED PRIME MOVER RATING 7.5 KW , MOTOR MAKECG apex 3PHASE INDUCTION MOTOR,MACHINE NO.7.50KNE2, KW & HP 7.5 KW& 10 hp VOLTS 415 +/- 10% ,BRG DE / NDE,DE6308- C3 /NDE 6208- C3 , DUTEY S1, REF QLAMRELUB HRS RPM & AMPFRAME NO. ,ND1325EFF, 94.00%,GREASE QTY / SHAFT ,120 grams HALF KEY BALANCED
8Domestic water pumps (Comprehensive Maint. Contract includes) :- Domestic water pump set of capacity 960 LPM at 70 m headwith suitable auto /manualstar delta starter ,control MCB ,indication lamp, metering . etc along with all accessories with SS casing chamber, SS shaft, standard fittings, SS impeller with necessary coupling to the electrical driven TEFC, squirrel cage induction.CMC Including cleaning of strainers,replacement of gaskets,vibration pads if required,Greasing at greasing points,replacement of seals and arrest any leaks fromfittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included. PUMP MAKE -KIRLOSKAR BROTHERS LTD PN0-18001034443 PUMP TYPE -CPHM 50/26,PUMP NO. 1701318015 , DIA NO. D10219A509/100,TOTAL HEAD 70 M DISCHARGE67.600 M3/Hr , PUMP INPUT -20.334, IMP DIA MM OF8M/246/30 SIZE & SPEED , 50X80mm & 2950 RPMRECOMMENDED PRIME MOVER RATING 30 L CUPLINGRRL-190/140ø32×55, L CUPLING MAT CODE ,A2424132109MOTOR MAKE & NO. C G apex/ no 30KE2 ,KW & HP 30 & 40.00 hp ,VOLTS415±10%, AMB 50°C ,BEARING DE/ NDE 6312 -2Z/6212 -2Z ,IEC 60034-1-E2, RPM 2950 A,52.00 DELTA THCL / RISE, F/B FRAME ND 200L CONN DIAG & DUTY ,302 & S1 IP55,HALF KEY BALANCED REF RIAM 20024 H2 50±5%
9UG Sump Dewatering water pumps (Comprehensive Maint. Contract includes) :-Under ground sump dewatering pump 1 HP Motor Delivery head upto 14 mtrsheadwith suitable auto /manualstar delta starter ,control MCB ,indication lamp, metering . etc along with all accessories with SS casing chamber, SS shaft, standard fittings, SS impeller with necessary coupling to the electrical driven TEFC, squirrel cage induction.CMC Including cleaning of strainers,replacement of gaskets,vibration pads if required,Greasing at greasing points,replacement of seals and arrest any leaks fromfittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included. PUMP MAKE KIRLOSKAR BROTHERS LTD , PUMP MODEL 750CW -HEAD REANG 4.5 TO 14 DIS REANG ,6-1 DEL SIZE, 50MM PUMP TYPE , SUBMERSIBLE MOTORKW/HP,0.75 /01 HP RPM 2900,AMP 1.63A,MAXSOLDE SIZE 20 MM, RPM 1450,HZ 50.
10Air Cushion tank CMC includes :- Air cushion tank ( material IS 2062/2002)with drain valve, gate valve, provision for pressure switches, pressure gauge etc inside the pump house.The tank fabricated out of 8 mm thick M.S.sheet cylindrical shape with 300 mm dia. and 1.5 m height.Make - Indegenious.CMC includes repair/ replacement of pressure switches ,isolating valves/cocks,safety valves ,Welding of supports.Cleaning and applying of anticorrosive Paint/Primerfollowed by application of SIgnal Red paint as required.Any other minor repairs in all respects to make the equipment operationally available 24X7 .Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
11CI Gate (sluice) valves :- Double flanged CI gate (sluice) valves of following sizes of ratings PN 1.6 with non rising stem conforming to IS-14846 with all necessary fittings like flanges, neoprene gaskets, nuts, bolts, hardware etc. Make - Leader. CMC includes removing of accumulated water in valve chamber,debris,grass , mud for making the valve chamber free for operation. Replacement of gland packing,gasket,replacing of valve wheel if required. Repair /Replacement defective valve of same make and model ,capacityto ensure 24X7 operation.Any other minor repairs in all respects to make the equipment operationally available 24X7
12200 mm dia.
13150 mm dia.
14100 mm dia.
1580 mm dia.
1665 mm dia.
1750 mm dia
1840 mm dia
19Non return valves : Double flanged CI Non return valves of following sizes of ratings PN 1.6 conforming to IS-5312 or IS 9338 as required with gun metal working parts CI body and including all necessary fittings like flanges, neoprene gaskets, nuts bolts for fixing with pipe, hardware etc. Make - Leader. CMC includes Repair/Replacement of defective NRV of same make and model and capacity.Any other minor repairs in all respects to make the equipment operationally available 24X7
20150 mm dia.
21100 mm dia.
2250 mm dia.
23Y" Strainer: "Y" strainer of following sizes made out of cast iron, with perforated brass filter fixed,in position, to flange or pipe with nut bolts, gaskets, washers etc. Make - Leader .CMC includes cleaning of strainers periodically, Repair/Replacement of defective ,Y -Strainerof same make and model and capacity. Any other minor repairs in all respects to make the equipment operationally available 24X7.
24200 mm dia.
25100 mm dia.
2665 mm dia.
27Air Release valves :- SS Air Release valvewith SS isolation valve, tapers, G.I. pipes and specials etc.Make- Leader . CMC includes periodical relasing of air/draining from fire shafts. Repair/Replacement of defective ,Air Rlease valves of same make and model and capacity.Any other minor repairs in all respects to make the equipment operationally available 24X7.
2825 mm dia single acting air release valve
29Upright type sprinkler :-Quartzoid bulb Sprinkler head end connection 15mm dia, upright type confirming to relevant IS amended upto date with standard response K=80 and temperature rating = 68 Deg C. with universaldeflector UL listedcomplete with fusible glass capsule, chromium finish. Make -M/sHD Fire Protect Pvt.Ltd. CMC includes replacement of used/defective/leaking/bursted sprinkler both in above and below false cieling with same make ,model and rating.Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
30Pendant type sprinkler :-Quartzoid bulb Sprinkler head end connection 15mm dia, pendanttype confirming to relevant IS amended upto date with standard response K=80 and temperature rating = 68 Deg C. with universaldeflector UL listedcomplete with fusible glass capsule, chromium finishalong with stainless steel rosette.Make -M/sHD Fire Protect Pvt.Ltd.CMC includes replacement of used/defective/leaking/bursted sprinkler both in above and below false cieling with same make ,model and rating. Any other minor repairs in all respects to make the equipment operationally available 24X7.Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
31Flexible drop pipes :- Metallic stainless steel (SS 304) braided Flexible drop pipes of 25mm dia with cross bar assembly support suitable for grid ceiling, reducing fitting, special shoulder Nipple, reducing nipple, T bar braket, braket clip assembly. Flexiblelength1500mm . Make -M/sHD Fire Protect Pvt.Ltd .CMC includes replacement of used/defective/leaking/bursted sprinkler both in above and below false cieling with same make ,model and rating. Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
32Flow switches :- Vane type flow switches (flow sensors) fixed directly on pipe line of the following diameters,Flow switch shall accommodate a micro switch with at least 2 NO and 2 NC contacts.The instrument is weather proof with IP55 cover and suitable cable gland are properly fixed. Out of 2 NO/NC contacts, one will be used for connecting to annunciator panel and other will be used for connecting to BMS.with 1 NO & 1 NC potential free contacts. Make -M/s ValkonPvt.Ltd (D K Instruments ). CMC includes Repair/Replacement of defective/Non functional,Flow Switches with same make,model and Specification. Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
33150 mm dia
34Alarm Valve :- 150mm dia Fire sprinkler Alarm valve HD fire / Tyco make with inlet and outlet connections pressure gauges including gong,trim assembly. Make -M/sHD Fire Protect Pvt.Ltd. CMC includes maintenance and checks withRepair/Replacement of defective/Non functional,Alarm valvewith same make,model and Specification. Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
35Pressure gauges :- Pressure gauges SS material not less than 150 mm dial with shut off gauge, cocks, all fittings etc.Make -M/sHD Fire Protect Pvt.Ltd. CMC includes Replacement of defective/Non functional, pressure gauges with same make,model and Specification.Any other minor repairs in all respects to make the equipment operationally available 24X7
36Pressure switches :- Pressure switches with a range of 0-15 kg/cm with low & high set points conforming to relevant IS specification, on air cushion tank, complete in all respects. Make -M/sIndfoss. CMC includes maintenance and checks withRepair/Replacement of defective/Non functional,pressure switcheswith same make,model and Specification.Any other minor repairs in all respects to make the equipment operationally available 24X7
37Landing valves:- Single outlet Oblique typeGM/Brass Hydrant landing valve, 80mm dia flanged inlet & 63mm dia instantaneous type female outlet with SS Hand wheel, SS blank cap & GI chain twist release type plugincluding providing 80mm dia GI"Heavy class" . Pipe piece of 450mm including nuts, bolts, washers, gaskets with necessary fittings like Tees, elbows etc.Make -M/sLeader Pvt.Ltd. CMC includes removing of accumulated water in valve chamber,debris,grass. Replacement of gland packing,gasket,replacing of valve wheel if required. Repair /Replacement defective valve of same make and model.Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelinesabove ground level for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
38External Stand post Hydrant :-Single outlet Oblique type GM/Brass Hydrant valve 80 mm dia inlet & 63 mm dia Instantaneous type female outletwith SS Hand wheel, SS blank cap & chain, twist release type plug including nuts, bolts,washers gasket.isolation gate valve (sluice) and 80 mm diaGI"Heavy class" pipewith duck foot bend, cement concrete thrust blocks of required sizes making flanged joints. Make -M/sArihant Fire Protection Service Pvt.Ltd .CMC includes removing of accumulated water,debris,grass around the hydrant post. Replacement of gland packing,gasket,replacing of valve wheel if required. Repair /Replacement defective valve of same make and model ,capacityto ensure 24X7 operation.Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines above ground levelfor painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
39Hose reels :- Rubber hose reel of 20mm dia X 36mlong with swinging drum along with high pressure braided rubber hose including 8mm dia SS cut of nozzle.Riser cum down comer including connecting the other end to the wet riser cum down comer by providing necessary connecting nipple / coupling, nuts, bolts etc.Make -M/sNew age Fire Protection Industries Pvt.Ltd. CMC includes replacement of rubber hoses , connceting valves (Dia -32 mm),jubliee clips and replacement of total unit in case of damage/failure.Any other minor repairs in all respects to make the equipment operationally available 24X7.
40Fire Hose boxes(External hydrant) :- Fire hose box made out FRP of size 750 X 450 X 250mm for accomodating 2 nos. hose pipe(each 15m long) and branch pipe with nozzle.The box have full front glass door with lock and key& with angle iron frame . MS angle iron supports of required height fixed in cement concrete foundation.The FRP fire hose box shall be painted with two coats of signal red enamel paint from outside and white enamel paint from inside.Make -M/sHD Fire Protect Pvt.Ltd.CMC shall be inclusive of maintenance ofbreak glass box containing key for the cabinet along with hammer. Hydrant cap ,Hydrant O- Ring, Locking pin, Rubber beading,painting.Any other minor repairs in all respects to make the equipment operationally available 24X7.
41Fire Hose boxes(Internal Hydrant) :-16G MS sheet metal box of size 750x450x200 mm to accommodate 02 nos. of hose pipe(15mtr length)and branch pipe with nozzle or hosy branch pipe with nozzle. The box shall have front glass door lock with angle iron frame. The hose pipe box shall be fixed with 4 nos. of C.P. Brass screws and rawal plugs on the wall and including painting with two coats of synthetic enamel paint of approved make.Make -M/sArihant Fire Protection Service Pvt.Ltd.CMC shall be inclusive of maintenance ofbreak glass box containing key for the cabinet along with hammer. Hydrant cap ,Hydrant O- Ring, Locking pin, Rubber beading,painting.Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
42Hose Pipes :- Hose pipe for fire fighting,(fabric reinforced Rubber lined woven jacketted (RRL) fire hose) of 63mm dia x 15m length, fitted with male and female Gunmetal coupling. Hose pipehaving ISI marks with bursting pressure of 35.7 Kg/sq.cm completed Make -M/sArihant Fire Protection Service Pvt.Ltd.CMC shall be inclusive of maintenance of hose reel, end fittings,replacement of hose in case of damage/leakage. Any other minor repairs in all respects to make the equipment operationally available 24X7.
43Branch pipes :- Stainless steelbranch pipe of 63mm dia fitted with detachable hexagonal nozzle suitable to connect hose pipe. Make -M/sArihant Fire Protection Service Pvt.Ltd. CMC includes maintenance of surface from rust,theft of nozzles, replacement in case of damage.Any other minor repairs in all respects to make the equipment operationally available 24X7.
44Siamese Connections :- Siamese Connections having four numbers 63 mm dia G.M. inlet (instantaneous male coupling)along with one number 150 mm dia C.I. double flange non return valve of of rating PN 1.6 with G.M. working parts, one number 50 mm dia G.M. drain valve ofand fittings all connected to 150 mm dia GI pipe with necessary fittings including blank caps.GM inlet housing box made out of 14 guage M.S. sheet with angle and frame in all respects. Make -M/sArihant Fire Protection Service Pvt.Ltd.CMC includes removing of accumulated water,debris,grass around the Siamese connections. Replacement of gland packing,gasket,replacing of valve wheel if required. Repair /Replacement defective valve,dummy piece of same make and model ,capacityto ensure 24X7 operation. Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines above ground level for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
45Fire Brigade Breaching inlets :- Fire brigade connection with 4 nos. GM make 63 mm dia instantaneous male coupling mounted on 150 mm MS pipe above fire water tank with all fittings for fixingwith pipe including blank cap and painting with 2 coats of signal red anti corrosive paint over 2 coats of red oxide primer etc.Make -M/sArihant Fire Protection Service Pvt.LtdReplacement of gland packing,gasket,replacing of valve wheel if required. Repair /Replacement defective valve,dummy piece of same make and model ,capacityto ensure 24X7 operation.Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
46Fire buckets :-Supply and placing of fire buckets filled with dry and clean sand to be kept on floor or wall hook. The fire bucket of galvanized mild steel of 13 litres capacity.Make -M/sSafex Pvt.Ltd . CMC includes maintenance of fire bukets with anti corrosive painting, repair/ replacement of bucket in case of damage. Any other minor repairs in all respects to make the equipment operationally available 24X7.
47HIGH VELOCITY WATER SYSTEM FOR TRANSFORMERS FIRE FIGHTING
48Deluge Valves (DV) with TRIM :- Deluge valves assembly along with all accessories complete in all respect .including all required accessories such as six way manifold, valves, NRVs, Emergency Release Box, restriction nozzles, Positive drain actuator, pressure gauges, stop valve, Drip valve, check valve, etc.CMC includes Repair /Replacement of complete or part assembly with same make & model and should be available for 24X7 operation. Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
49100 mm dia
50H. V. Nozzles :-H.V. Nozzles all as per drawing,15 mm dia . CMC includes Repair/Replacement of Nozzle in case of bursting/Testing with same make and model. Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
51Quartzoid Bulb Detectors :-Quartzoid Bulb DetectorsBulb detectors all as per drawing,15 mm dia.Any other minor repairs in all respects to make the equipment operationally available 24X7. Maintenance of all associated pipelines for painting, corrosion,Rubber Joint replacements, arresting of any type of leaks is also included.
52Y Strainer :-"Y" strainer 100 mm dia made out of cast iron, with perforated SS filter fixed, in position,to flange or pipe with nut bolts, gaskets, washers etc. in an apporved manner, complete in all respect as per drawing.CMC includes Repair /Replacement of complete or part assembly with same make & model and should be available for 24X7 operation.Any other minor repairs in all respects to make the equipment operationally available 24X7.
53CI Gate (sluice) valves :- Double flanged CI/Cast Steel Gate Valve of required sizes of ratings PN 1.6 with rising stem conforming to IS-14846 with all necessary fittings like flanges, neoprene gaskets, nut bolts, hardware, flange joint etcCMC includes removing of accumulated water in valve chamber,debris,grass , mud for making the valve chamber free for operation. Replacement of gland packing,gasket,replacing of valve wheel if required. Repair /Replacement defective valve of same make and model ,capacityto ensure 24X7 operation.Any other minor repairs in all respects to make the equipment operationally available 24X7
54150 mm dia
55100 mm dia
56Gun Metal Ball Valve :- Gun Metal Ball Valve of 25 mm dia.CMC includes Repair /Replacement of complete or part assembly with same make & model and should be available for 24X7 operation. Any other minor repairs in all respects to make the equipment operationally available 24X7.
57Carbon-di-oxide Fire extinguishers -4.5 Kg :- Extinguisher consisting Flat base including valve, discharge hose & complete in all respects including filling with CO2 gas conforming to IS 15683:2006,wall suspension bracketas required. Make -M/sSafex Pvt.Ltd, M/s KANEX Ltd M/s Fire Tite Ltd. Filling of all the extinguishers after awarding work order followed by CMC includes Refilling of expired extinguishers after expirydate/ Emergency usage/ Training, Marking of next due date with suitable sticker on extinguisher ,replacement of defective Flexible hose,Pressure gauge,Locking pin,Operating handle ,Clamp, with same model . Fixing of extinguishers if removed / loosely fitted . markingof Calibration/ Refilling date and due date on eachextinguisher.Any other minor repairs in all respects to make the equipment operationally available 24X7.
58Carbon-di-oxide Fire extinguishers -2.0 Kg :-Extingusher consisting of Flat base including valve, discharge hose & complete in all respects including initial fill with CO2 gas conforming to IS 15683:2006,wall suspension bracketas required.Make -M/sSafex Pvt.Ltd, & M/s FIre Tite . Filling of all the extinguishers after awarding work order followed by CMC includes Refilling of expired extinguishers after expirydate/ Emergency usage/ Training, Marking of next due date with suitable sticker on extinguisher,replacement of defectiveFlexible hose,Pressure gauge,Locking pin,Operating handle ,Clamp, with same model . Fixing of extinguishers if removed / loosely fitted . markingof Calibration/ Refilling date and due date on eachextinguisher. Any other minor repairs in all respects to make the equipment operationally available 24X7.
59Carbon-di-oxide Fire extinguishers -9.0 Kg :-Carbon-di-oxide Fire extinguishers capacity of 9.0 Kg(Trolly Mounted),Flat base including valve, discharge hose & complete in all respects including initial fill with CO2 gas conforming to IS:2878.Make -M/sSafex Pvt.Ltd .Filling of all the extinguishers after awarding work order followed by CMC includes Refilling of expired extinguishers after expirydate/ Emergency usage/ Training, Marking of next due date with suitable sticker on extinguisher,replacement of defectiveFlexible hose Flexible hose,Pressure gauge,Locking pin,Operating handle ,Clamp, with same model . Fixing of extinguishers if removed / loosely fitted . markingof Calibration/ Refilling date and due date on eachextinguisher.Any other minor repairs in all respects to make the equipment operationally available 24X7.
60ABC Fire extinguishers - 6.0 KG :- Extinguisher consisting of pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683:2006 as required. Make -M/sSafex Pvt.Ltd & M/s KANEX & M/s Firetite.Filling of all the extinguishers after awarding work order followed by CMC includes Refilling of expired extinguishers after expirydate/ Emergency usage/ Training, Marking of next due date with suitable sticker on extinguisher,replacement of defectiveFlexible hose,Pressure gauge,Locking pin,Operating handle ,Clamp, with same model . Fixing of extinguishers if removed / loosely fitted . markingof Calibration/ Refilling date and due date on eachextinguisher.
61ABC Fire extinguishers - 2.0 KG :-Extinguisher consistig of pressure indicating gauge, internal tube, squeeze lever type valve fullycharged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete n all respects including wall suspension bracket.Make -M/sSafex Pvt.Ltd & M/s Firetite. Filling of all the extinguishers after awarding work order followed by CMC includes Refilling of expired extinguishers after expirydate/ Emergency usage/ Training, Marking of next due date with suitable sticker on extinguisher,replacement of defectiveFlexible hose,Pressure gauge,Locking pin,Operating handle ,Clamp, with same model . Fixing of extinguishers if removed / loosely fitted . markingof Calibration/ Refilling date and due date on eachextinguisher. Any other minor repairs in all respects to make the equipment operationally available 24X7.
62Mechanical Foam Type Extinguisher -9.0 KG :-Mechanical foam Type Extinguisher, capacity of 9.0 Kg(Trolly Mounted) complete in allrespects including initial fill and as required .Make -M/sSafex Pvt.Ltd & M/s KANEX.Filling of all the extinguishers after awarding work order followed by CMC includes Refilling of expired extinguishers after expirydate/ Emergency usage/ Training, Marking of next due date with suitable sticker on extinguisher,replacement of defectiveFlexible hose,Pressure gauge,Locking pin,Operating handle ,Clamp, with same model . Fixing of extinguishers if removed / loosely fitted . markingof Calibration/ Refilling date and due date on eachextinguisher. Any other minor repairs in all respects to make the equipment operationally available 24X7.
63NOVEC 1230 GAS SUPPRESSION SYSTEM SPEC -CT ROOM :- Quote Lumpsum charges for CMC of complete NOVEC GAS systemfor CT -SIMULATOR including refilling for any loss in the system to mainatin the pressure gauge in operating zone, all the equipment, accessories,electric and electronic circuits,PCB Cards,Panel, Software/program if any .Any other minor/major repair, replacement of any component/equipment complete in all respects to make the equipment operationally available 24X7. The System Consists of the following :- 80 L Capacity Seamless cylinder CCOE approvedwith syphon tube, Cylinder valve with pressure gauge & safety burst disc - 03 No"s Novec 1230 gas/fluid 150 Kgs Electrical Actuator 1No"s Manual Pneumatic Actuator 1No"s Actuator adaptor 2 No"s Pneumatic actuator 2 No"s Discharge Flexible Hose 2 No"s Pneumatic Actuation Hose with fittings 3 No"s Discharge nozzles 4 No"s Piping:- M.S. Seamless Sch.40 ASTM A-106 Gr.B with necessary fittings, supports, etc.1No"s Single Cylinder wall fixing bracket 4 No"s Warning Sign 1 No"s Gas Release Unit 1 No"s Gas inhibit Unit 1 No"s Conventional Detection System Apollo make Sr.65 Conventional Optical smoke Detector c/w base or multi-sensor/ Heat Detector8 No"s Conventional hooter with flasher 2 No"s 2 Zone fire alarm + 1 area gas release panel c/w inbuilt Power supply, battery charger & battery backup1 No"s 2 x 1.5 sq.mm Copper armouured cable200 Mtrs Response Indicator 4 No"s Audio Visual repeat Indicator at fire Control room1 No"s All major & minor Accessories for releasing and aborting NOVEC gas with electronic components1 Set
64NOVEC 1230 GAS SUPPRESSION SYSTEMPET -CT :- Quote Lumpsum charges for CMC of complete NOVEC GAS systemfor CT -SIMULATOR includingincluding refilling for any loss in the system to mainatin the pressure gauge in operating zone, all the equipment, accessories,electric and electronic circuits,PCB Cards,Panel, Software/program if any .Any other minor/major repair, replacement of any component/equipment complete in all respects to make the equipment operationally available 24X7. The System Consists of the following :- 80 L Capacity Seamless cylinder CCOE approvedwith syphon tube, Cylinder valve with pressure gauge & safety burst disc - 03 No"s Novec 1230 gas/fluid 220 Kgs Electrical Actuator -2No"s Manual Pneumatic Actuator2 No"s Actuator adaptor 3 No"s Pneumatic actuator 3 No"s Discharge Flexible Hose3No"s Pneumatic Actuation Hose with fittings 4 No"s Discharge nozzles 6 No"s Piping:- M.S. Seamless Sch.40 ASTM A-106 Gr.B with necessary fittings, supports, etc. 2No"s Single Cylinder wall fixing bracket 6 No"s Warning Sign2 No"s Gas Release Unit 2 No"s Gas inhibit Unit2No"s Conventional Detection System Apollo make Sr.65 Conventional Optical smoke Detector c/w base or multi-sensor/ Heat Detector12 No"s Conventional hooter with flasher 4 No"s 2 Zone fire alarm + 1 area gas release panel c/w inbuilt Power supply, battery charger & battery backup2 No"s 2 x 1.5 sq.mm Copper armouured cable350 Mtrs Response Indicator 6 No"s Audio Visual repeat Indicator at fire Control room2 No"s All major & minor Accessories for releasing and aborting NOVEC gas with electronic components1 Set
65NOVEC 1230 GAS SUPPRESSION SYSTEMCT - SIMULATOR:- Quote Lumpsum charges for CMC of complete NOVEC GAS systemfor CT -SIMULATOR includingincluding refilling for any loss in the system to mainatin the pressure gauge in operating zone,all the equipment, accessories,electric and electronic circuits,PCB Cards,Panel, Software/program if any .Any other minor/major repair, replacement of any component/equipment complete in all respects to make the equipment operationally available 24X7. The System Consists of the following :- 80 L Capacity Seamless cylinder CCOE approvedwith syphon tube, Cylinder valve with pressure gauge & safety burst disc - 03 No"s Novec 1230 gas/fluid162 Kgs Electrical Actuator -2No"s Manual Pneumatic Actuator2 No"s Actuator adaptor 3 No"s Pneumatic actuator 3 No"s Discharge Flexible Hose3No"s Pneumatic Actuation Hose with fittings 4 No"s Discharge nozzles 6 No"s Piping:- M.S. Seamless Sch.40 ASTM A-106 Gr.B with necessary fittings, supports, etc. 2No"s Single Cylinder wall fixing bracket 6 No"s Warning Sign2 No"s Gas Release Unit 2 No"s Gas inhibit Unit2No"s Conventional Detection System Apollo make Sr.65 Conventional Optical smoke Detector c/w base or multi-sensor/ Heat Detector12 No"s Conventional hooter with flasher 4 No"s 2 Zone fire alarm + 1 area gas release panel c/w inbuilt Power supply, battery charger & battery backup2 No"s 2 x 1.5 sq.mm Copper armouured cable350 Mtrs Response Indicator 6 No"s Audio Visual repeat Indicator at fire Control room2 No"s All major & minor Accessories for releasing and aborting NOVEC gas with electronic components1 Set
66Removing, Refilling,Reinstallingof 01 No. 80 L cylinder with NOVEC Gas ,pressure testing and pressure gauge replacing if required
67NOVEC 1230 GAS SUPPRESSION SYSTEMCT- SCAN :- Quote Lumpsum charges for CMC of complete NOVEC GAS systemfor CT -SIMULATOR includingincluding refilling for any loss in the system to mainatin the pressure gauge in operating zone,all the equipment, accessories,electric and electronic circuits,PCB Cards,Panel, Software/program if any .Any other minor/major repair, replacement of any component/equipment complete in all respects to make the equipment operationally available 24X7. The System Consists of the following :- 80 L Capacity Seamless cylinder CCOE approvedwith syphon tube, Cylinder valve with pressure gauge & safety burst disc - 03 No"s Novec 1230 gas/fluid189 Kgs Electrical Actuator -1 No"s Manual Pneumatic Actuator1 No"s Actuator adaptor 3 No"s Pneumatic actuator 3 No"s Discharge Flexible Hose3No"s Pneumatic Actuation Hose with fittings 4 No"s Discharge nozzles4 No"s Piping:- M.S. Seamless Sch.40 ASTM A-106 Gr.B with necessary fittings, supports, etc.1 No"s Single Cylinder wall fixing bracket 6 No"s Warning Sign1 No"s Gas Release Unit 1No"s Gas inhibit Unit 1 No"s Conventional Detection System Apollo make Sr.65 Conventional Optical smoke Detector c/w base or multi-sensor/ Heat Detector8 No"s Conventional hooter with flasher 2 No"s 2 Zone fire alarm + 1 area gas release panel c/w inbuilt Power supply, battery charger & battery backup1 No"s 2 x 1.5 sq.mm Copper armouured cable220 Mtrs Response Indicator 4 No"s Audio Visual repeat Indicator at fire Control room1 No"s All major & minor Accessories for releasing and aborting NOVEC gas with electronic components1 Set
68FIRE ALARM SYSTEM :-CMC of complete Fire Alarm Sysytemof all blocks viz. RT Block,Doctors Hostel,Nurses Hostel,Dhramashala, Sevice Block, RegistrationBlock,Substation,Cafeteria Block .Any other minor/major repair, replacement of any component/equipment complete in all respects to make the equipment operationally available 24X7 consisting of below mentioned equipments. Any damages to existing wiring connected to Fire alarm, Smoke detector, any other sensor/Detector connected with fire fighting alarm system is included in this scoe of work. Replacement of Alarm Panels, installation of Software, PCB cards , any other accesories related to complete Fire Alarm monitoring system is included in this scope of work :-
69Smoke detector below false ceilingMake -Hekatron, Model-MTD 533X
70Smoke detector above false ceiling with Response indicator ,Make-Hekatron/ Rchrack , Model-MTD 533X / BX-UPI
71Smoke detector in direcet ceiling, Make- Hekatron,Model- MTD 533X
72Heat detector, Make- Hekatron, Model- LKM593X
73Duct detector with monitor modular , Make- Hekatron , Model- LKM593X
74Manual Call Point ( MCP ) ,Make- Schrack, Model- MCP545X-2R
75Loop poweredHooter, Make- Schrack,Model- BX-SOL-R
76Control rely module ( CRM ) , Make- Schrack, Model- BX-O1
77Monitor module (MM ) , Make- Schrack, Model- BX-I2
784Loopfire alarm panelMake- Schrack
791Loopfire alarm panel ,Make- Schrack
80number of Fire cables loop
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy