| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 2 | Excavationforfoundationinhardmurum includingremovingtheexcavatedmaterialupto distanceof 50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthe bedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringandstrutting etc.complete.(Liftupto1.50m)ByMechanical Means |
| 3 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/quartzite/ gneiss metal for foundation and bedding including bailing out water, Steelcentering,formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredand curingcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Typemixer/concreteBatchmixplant(Panmixer)etc.complete. Withfineaggregate(CrushedsandVSI Grade) Bd. E. 1 Page Number 287 |
| 4 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalfor R.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsand steel stanchionsetc. including bailing out water,Steelcentering formwork, laying/pumping cover blocks, compaction and curingrougheningthesurfaceifspecialfinishistobeprovided(Excluding reinforcementandstructuralsteel)etc.complete,withfullyautomaticmicroprocessorbasedPLCwith SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.3 Page Number 298 and B.7, Page Number38 |
| 5 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering,formwork,coverblocks,laying/pumping,compactionfinishing the formedsurfaceswithcement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumTypemixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.5 Page Number 300 and B.7, Page.Number 38 |
| 6 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) Bd.F.6 Page Number 300 and B.7, Page Number38 |
| 7 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Bd.F.8 Page Number 302 and B.7, Page Number38 |
| 8 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) Bd.F.9 Page Number 303 and B.7, Page Number38 |
| 9 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings andschedules.including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Bd.F.17, Page Number 306 |
| 10 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:6 infoundationsandplinthofinnerwalls/inplinthexternalwallsincludingbailingoutwatermanually, striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete. Bd.G. 1 Page Number 313 |
| 11 | Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.layersincluding watering and compacting etc. complete. Bd.A.10 Page Number 262 |
| 12 | Fillinginplinthandfloorswithcontractors material/broughtfromoutsideandapprovedbyEngineer incharge inlayersof15cm to20cmincludingwateringandcompactionetc.complete. Bd.A.11 Page Number 263 |
| 13 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6 insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete Bd.G.5 Page Number 315 |
| 14 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop ironstrips25mm X1.6mm placed ateverythirdcourse,properlybentandbondedatendsscaffolding, racking out joints and watering etc. complete. Bd.G.7 Page Number 316 |
| 15 | Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete. As directed by Engineer in charge. |
| 16 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Bd. L.2 Page Number 368 |
| 17 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:5without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Bd.L.4 Page Number 368 |
| 18 | Providing and fixing steel frame door of angle 50 x 50 x 6 mm with mild steel bars 16 mm dia. horizontally at 10mm c/c for ventilator portion including iron hold fast boxes for fixing shutters including welding, finishing, painting etc. complete. As directed by Engineer in charge. |
| 19 | Providing and fixing steel window C.R.C. sheet as per I.S. 1513 : 1986. gauge sect. 65 x 40 x 25 mm shutter single sheet of 24 gauge single leaf joinedby fusion welding at appropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first andlastribshouldbe60mmawayfrom verticaledgeoftheshutter.theshuttershallbe welded, with angle to from the periphery of the shutter. At the center of the frame there shall beangleweldedtobifurcatetheframeintosegmentswithtwoleaf shuttersquare12mm square guard bars at 120 mm center with all accessories As directed by Engineer in charge. |
| 20 | Providing and fixing steel ventilator fully glazed partly fixed as per detailed drawing without hotdipzinc coatingincluding fabricatingglazing withplain/obscuredglasspanes5mm thick and approved type and quality and iron oxidized fixtures and fastening oil paint 2 coats etc. complete. BD-T-53Page Number 509 As directed by Engineer in charge. |
| 21 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cementplasteredsurfaces includingscaffoldingifnecessary,preparingthesurfacebythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete. As directed by Engineer in charge. |
| 22 | Providing and applying external raincoat painting with crack fillingacrylic polymer basedchemical compoundcoatingtotheexternalsurfaceofwallstopreventwaterseepageinthemasonrywallsduring monsoonaddedwithrequiredshadeSteinertogiverequiredshadetothesurfaceintwocoats.Including providing three coatofpriming ofpolymerbaseprimerincludingpreparing surfacescrapping theexisting looseoldpaint,removinglooseparticlesofsand on the surface opening and cleaning the cracks developed in theexternalplaster, removinglooseparticlesbychiseling,fillingcracksbychemicals compoundofapproved makewithproperpenetrationetc.CoatingofRaincoatwiththehelpofbrush andasper instructions andspecificationgivenby manufacturerandwithinstructionfrom Engineer in- charge. Work shall be executed by certified applicator only and covering gurantee of 3 years on court stamp paper of Rs. 500/- and necessary testing etc. complete. As directed by Engineer in charge. |
| 23 | Providing and applying two coats of lead/zinc base oil paint/bituminous paint of approved colourandshade tonewwoodworkandfiberboardsincludingpreparingthesurface, knotting, scaffolding if necessary, excluding primer coat etc. complete. Bd.O. 1 Page Number 403 |
| 24 | Providing and fixing coloured glazed earthenware Wash Hand Basin of 45 cm x 30 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connectionincluding P.V.C. waste pipe andtrapup to the outside face ofthe wall.Making goodthe damaged surface, testing etc. complete. Bd.V.30 Page Number 565 |
| 25 | Providing andlaying for 150 mm dia salt glazedstoneware pipe including fittings Suchas bends, tees, single junction, double junctions laying, jointing (including excavation andrefillingthe trenches) complete. Bd.V.39, Page Number 573 |
| 26 | Providingsoakpitofsize 120cm x120cm x120cmincluding excavatingandfilling with brick-bats. Bd.V.46, Page Number 576 |
| 27 | ProvidingandfixingOrissatypewhiteglazedearthenware575mmwaterclosetpan including S trap withearthenware footrests,castironsoilandventpipe uptooutside face ofthe wall 1:2:4brick batlime concrete bedding without flushing tank and its accessories etc. complete. As directed by Engineer in charge. |
| 28 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and builtcorrugatedinclusiveofdeliveryuptodestinationhoistingand fixing of accessories such as inlet,outletoverflowpipeinclusiveofalltankscapacity between 200 to 1000 liters As directed by engineer-in- charge. |
| 29 | Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (groupDII-A)and7to8mm thickforflooring inrequiredpositionlaidonabedof1:4cementmortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Bd.M.12 Page Number 385. |
| 30 | Providingandlayingceramictilesof havingsize30cm.x30cm.andconfirmingto corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. Bd.M.13 Page Number 386. |
| 31 | Providingandfixing20mm dia.screwdownbib/stoptapofbrassincluding necessarysocketunionnut complete. Bd.V.8 Page Number 554 |
| 32 | Providingandfixingonwalls/ceiling/floors20mmdia.heavygradehavingembossedasISIMark galvanised iron pipes of 1.93 Kilogram/meter with necessary fitting remaking good the demolishedportion andapplyingprimerofanti-corrosiveoilpaint,2coatsIncluding necessaryscaffoldingandremoving existingpipelineifnecessaryandconveyingand stacking the same in PWD chowky or as directed etc. complete.Bd.V.5 Page Number 551c |
| 33 | Providingand fixingblackkadappastoneas shelves25mm. thickmachinepolished, extendingthe polish upto 20 cm width on lowerside, rounding corners, laying in positionjointingwithbedding cement mortar 1:4 proportion curing etc etc. complete. Bd.M.29 Page Number 391 |
| 34 | ROYALTY CHARGES :- Supply of Rubble, Murum, Soil, 60mm./40mm. metal (Hand broken), royalty charges are not included in the rates.[As per Govt. of Maharashtra, Revenue and Forest Departments Gazette No.67 Dt.15 May,2015. States that the royalty charges ofRs.141.34/Cu.M. ) are considered. The surcharge levied on Royalty shall also be payable to the contractor.ROYALTY CHARGES FOR SAND |
| 35 | ROYALTY CHARGES FOR OTHER MINERALS |
| 36 | Laboratory testing charges are not considered in the Rate Abstracts. Where ever required separate item shall be taken in the estimate for material testing charges, on the basis of testing frequency and charges fixed by Vigilance & Quality Control Circle, for the current year and shall form part of tender.testing of material by Quality control and certified quality must be use by contractor. CONCRETE Compressive Strength of C. C. Cube (Set of 3 Cubes) |
| 37 | PART II- ADD 12% GST |
| 38 | 1% FOR LABOUR INSURANCE |