C / O Flow Irrigation Scheme Sarankani Kuhal Co Rcc Trench Weir Rcc De Siltting Chamber 2 Nos Rcc Lining Of Main Channel Cut And Cover 2520 Mtrs Rcc Main Channel 7865 Rmts And Co Out Let Chamber De- Silting Drainage System Co Aqueduct Foot Path Cross, Shahpur-Himachal Pradesh

Irrigation And Public Health Department has published C / O Flow Irrigation Scheme Sarankani Kuhal Co Rcc Trench Weir Rcc De Siltting Chamber 2 Nos Rcc Lining Of Main Channel Cut And Cover 2520 Mtrs Rcc Main Channel 7865 Rmts And Co Out Let Chamber De- Silting Drainage System Co Aqueduct Foot Path Cross. Submission Date for this Tender is 29-11-2021. Irrigation Work Tenders in Shahpur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29814400
Corrigendum : C / O Flow Irrigation Scheme Sarankani Kuhal Co Rcc Trench Weir Rcc De Siltting Chamber 2 Nos Rcc Lining Of Main Channel Cut And Cover 2520 Mtrs Rcc Main Channel 7865 Rmts And Co Out Let Chamber De- Silting Drainage System Co Aqueduct Foot Path Cross
Open Tender
Indian
Himachal Pradesh
Shahpur
29-11-2021

Tender Details

C / O Flow Irrigation Scheme Sarankani Kuhal Co Rcc Trench Weir Rcc De Siltting Chamber 2 Nos Rcc Lining Of Main Channel Cut And Cover 2520 Mtrs Rcc Main Channel 7865 Rmts And Co Out Let Chamber De- Silting Drainage System Co Aqueduct Foot Path Crossing And Retaining Wall Etc

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Nov-2021 C/O Flow Irrigation Scheme Sarankani Kuhal Date 29-11-2021

Key Value

Document Fees
INR 2500 /-
EMD
INR 936047.0 /-
Tender Value
INR 9.35 Crore /-

BOQ Items

Name of Work: C/O Flow Irrigation Scheme Sarankani Kuhal in Tehsil Shahpur Distt. Kangra (HP) (SH:- C/O RCC trench Weir, RCC De siltting chamber (2 Nos), RCC Lining of Main channelcut and cover2520 mtrs, RCC main channel 7865 Rmtsand , C/ O out let chamber,De- silting/ Drainage systemC/ O Aqueduct , Foot path crossingandRetaining walls etc. ) Estimated Cost- 93596266/- Earnest Money- 936047/- Time Limit- Three Year
Sl. No. Item Description
1Design, construction , testing and commissioning of R.C.C trench weir in M 30 grade cement concrete across Kholi Khad as per site condition of appropriate length and height including depth above and below the natural bed level of khad to obtain 374.47 LPS discharge as per proper design requirment including the cost of site development, excavation, cutting and dewatering etc in all kinds of soil. The structural design of trench weir shall strictly confirm to relevent of BIS code and specification.
2Design, construction , testing and commissioning of R.C.C aqueductin M 30 grade cement concrete 20 mtrs longand 4.5 mtrs high (2 Nos) at (i) RD1300 to1320(ii)1480 to 1500, 10 mtrs long4 mtrs high (2 Nos) at RD 8765 to 8775, 8820 to 8830, and 5 mtrs longand 4.5 mtrshigh (1 Nos) at RD 10265 to 10270. at per site condition appropriate height and depth above and below the natural bed level. i/c the cost of site development, excavation, cutting and dewatering etc in all kind of soil.The structural design of trench weir shall strictly confirm to relevent of BIS code and specification.
3Design, construction , testing and commissioning of R.C.Cmain channel(cut and cover )fromRD 0 to 2520 =2520 rmts to carry the 374.47 LPS flow of water inM 25grade cement concreteas per proper design and drawingi/c the cost of site development, excavation, cutting and dewatering etc in all kind of soil as per direction of Engineer-in-Charge within all leads and lifts.
4Excavation in foundation trenches etc. in earth work in all kinds of soil such as pick work,jumper work, blasting work soft /hard rock,chieslingsoft /hard rock where blasting is prohibited, slushy, daldal and saturated soil I/c pumping or bailling out water with in all heights stacking the excavated soil with 15cm layer when required into plinth ,sides of foundations etc. consolidating each deposited layerbyramming and watering and then disposing of all surplus earth as per direction of Engineer-in-Charge with in all leads and lifts .
5Providing form work with steel plates 3.15mm thick welded with angles iron in frame 30x30x5mm so as to give a fair finish i/c centring,shuttering,strutting and propping etc. with wooden batten and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.height of propping and centring below supporting removal of the same for insitu work in:-
6Vertical surfaces such as walls(any thickness)bartitions and the like i/c attached,pillasters plinth and string courses and the like within all leads and lifts.
7In duct of Kuhal ( in Sqm)
8Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilevers upto floor level within all leads and lifts.
9Providing and laying cement concrete 1:4:8(1 cement: 4sand: 8graded stone agg.40mm nominal size)and curing complete excluding cost of form work in foundation and plinth within all leads and lifts.
10Providing and laying cement concrete 1:3:6(1 cement: 3sand: 6graded stone agg.40mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts.
11P/L C.C. 1:2:4(1 cement: 2sand: 4graded stone agg.40mm nominal size)and curingcomplete excluding the cost of form work and reinforcement work for rainforcement cementconcerete work in foundation and plinthcomplete within all leads and lifts.
12Vertical surfaces such as walls(any thickness)partitions and the like i/c attached,pillasters plinth and string courses and the like within all leads and lifts.
13Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilevers upto floor level within all leads and lifts.
14Providing and layingCement concrete 1:5:10(1 cement: 5sand: 10 graded stone agg.40mm nominal size)with 15% plum and curing complete excluding cost of form work In retaining walls/breast walls, thesize of plum shall usually be 150mm to 300mm as per HP.PWD specifications.
15Providing and laying cement concrete 1:6:12 (1 cement:6 sand: 12 graded stone aggregate 40 mm nominal size) and curing complete excludingcost of centering and shuttering in foundation and plinth.
16Providing mild/tor steel reinforcement for RCC work i/c bending, binding and placing in position complete upto floor two level within all leads and lifts. ( in Kgs.)
17Providing & fixing CI Sluice valve ( with hand wheel)make Kirloskar / Leader / KSB / PN-1.0 as per IS: 780:1984 class -I upto 300mm dia.( i/c brass spindle & as per 2906-1984 class-II for dia. 300 mm ) complete with bolts nuts, rubbe insertion etc., ( the tail piece if required shall be measured & paid for separately). within all leads and lifts. (300 mm dia )
18Providing ,Laying ,jointing and testing MS steel pipe 300 mm dia4 mm thick. (excluding the cost of earth work in trenches) within all leads and lifts of following dia. (IS - 3183 -2012 grade -FE- 330.)
19Providing, Laying jointing and testing HDPE pipe 100 mm dia. (In Rmts ) as per IS 4984: 1995 PE - 80 , 4.00 Kg / centimeter square.
20Providing, Laying, Jointing and testingMSERWof 300 mm dia 4.00 mm thick .make such as Jindal / Swastik / Surya/ Roshni with galvanised Zink coated as per BIS 3589 - 1991 steel grade FC - 330,includingflange , anti corrosive treatment in all respect (excluding the cost of earth work in trenches) within all leads and lifts.
21Providing and Fixing Ball valve ( PVC ) 100 mm dia of reputed makewithin all leads and lifts.
22Steel work welded in built up sections,trusses and framed work, including cutting ,hoisting ,fixing in position and applying a priming coat of red lead paint:- In beams ,joints, channels angle cleats as in main and cross beams , lip and jack, rafters, pillers connected to common rafters and the like, angle iron gate etc.within all leads and lifts.
23Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement : 3 sand) within all leads and lifts.
24Providing and fixing water stoper seal 230 mm wide 6 mm thick complete within all leads and lifts. ( GB 18173 - 20 - 2000 polymer)
25Providing and fixing bitumen fiber board 12 mm thick of approved make within all leads and lifts ( ASTM - D. 1751-83/D - 545 - 84)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail