}

Tender For 11 Kv And Lt Line Pole Broken Due To Heavy Strom Therefore Damage On Various Location 11 Kv 09 No And Lt Line Pcc Pole 26 No Under Jaora R Dc-Madhya Pradesh

Madhya Pradesh Paschim Kshetra Vidhyut Vitran Corporation Limited has published Tender For 11 Kv And Lt Line Pole Broken Due To Heavy Strom Therefore Damage On Various Location 11 Kv 09 No And Lt Line Pcc Pole 26 No Under Jaora R Dc. Submission Date for this Tender is 08-11-2021. Pure Elemental Gases Tenders in Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29735248
Tender For 11 Kv And Lt Line Pole Broken Due To Heavy Strom Therefore Damage On Various Location 11 Kv 09 No And Lt Line Pcc Pole 26 No Under Jaora R Dc
Tender
Indian
Madhya Pradesh
08-11-2021

Tender Details

Tender For 11 Kv And Lt Line Pole Broken Due To Heavy Strom Therefore Damage On Various Location 11 Kv 09 No And Lt Line Pcc Pole 26 No Under Jaora R Dc , in jaora town area vairous nos of poles deteriorate due to aging effects or dueto mud and water ,an estimate has been framed for replacement of 02 no 11 kv vcb on hathikhana thq feeder and ratlami gate thq feeder due to mechanical distrance , bapu sarpanch wala 100 kva dtr at vill- sarwani found over loaded to reduced over loading req .nust additional 25kva dtr ,estimate for vcb installation on dlf feeder wich is opperate by 11 kv 3 no main at kharwakala s/s , an estimate has been proposed for replacement of detoriated damaged lt rs joist pole , nd gaffar khan s/o sattar khan location akya fanta piploda rod ,estimate has been framed for 2 nos 33 kv broken pole on 33 kv bhojakhedi feeder ,estimate of 25 kva additional dtr for overloading 63 kva dtr shivlal ke khe wala 87 hp load , incharge medical officer civil hospital jaora has applied for new oxygen plant unit-2 connection , vcb of 11 kv moedl thq feeder and naryangarh dlf feeder is not in service , its mechanical part is not working and it has been declared unservicible by tsg department ,10 kw new service connection for providing supply to new petrol pump connection throught 25 kva transformer ,app recieved from relaince jio info ltd c/o nitin chansoriya for cl nsc 4 kw at village usargar , due to overload dtr it becomes necessary to augment 25 to 63 kva stimate framed in full deposit scheme ,estimate for 11 kv vcb replacement banji dlf feeder 33/11 kv s/s gangasagar of dhamnod d/c under ratlam o&m division , 33 kv shivgarh feeder datoriated 3 no pcc pole near khetalpur under ratlam o&m ,estimate of 25 kva additional dtr for overloading 100 kva dtr devda wala 93 hp load ,nd virendra kumar panel s/o arjun bai patel location tal choukri jaora ,estimate for nd scheme 11 kv line 0.49 km and 11 kv tapping pole and 1 x 25 kva dtr at applicant aashu s/o rajesh choudria , estimate for nd scheme 11 kv line 0.49 km and 11 kv tapping pole and 1 x 25 kva dtr and applicant aashu s/o rajesh chourdia , location ujjainby pass rod nsc 10 kw ndl , estimate for nd scheme augmentation 63 to 100 kva dtr at applicant ,an estimate hasbeen proposed for installtion of new 11 kv vcb on main ptr 2 at sukheda substation due to mechanical damage ofold vcb at 33/11 kv sukheda substation under sukheda dc of jaora division , an estimate has beenproposed for installation of new 11 kv vcb on maukhhedi dlf due to doom burst of old vcb , estimate for nd scheme 11 kv line 63 kva dtr , estimate for additional 25 kva dtr , replacement of 11 kv badoda irr vcb pipload 33/11 kv ss , estimate framed for additional 1*100 kva dtr installation , estimate for providing 1 *100 kva additional transformer at overloaded mohanmmanda sahab wali location in jeeran dc ,krishan trading co propo sh fatehchand s/o madhonarayan bansal 95 hp cd 42 kw connection on survey no 411 & 417 fourlane at village barukheda a 100 kva transformer with necesary material will be installed on barukheda dl feeder by reusing the line and dp pole ereated for temporary connection , m/s gulati industries parthner mamta w/o lavnish gulati has load enhancement 74 hp to 120 hp of gulati industries on 11 kv girdoda dl feeder existing dp is on pcc pole structure hence 200 kva dtr will be rest on stone plinth will be constructed by application in r-1 dc , estimate framed as per voltage problem at boradiya kala jawan singh wala 100 kva dtr due to overload and vr so estimate framed additional 100 kva total loafd on 100 kva in 110 hp so additional dtr

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail