| 1 | FIRE HOSE REEL & HYDRANT SYSTEMS |
| 2 | od105088/2021_2022 : Supply, installation, testing and commissioning of Manual Swing Type Fire Hose Reel Complete Set with heavy duty drum / reel, 19mm. dia. x 30Mtr. long 2-ply polyester yarn braided / rubber braided pressure hose, Red Coloured, heavy duty nylon on/off jet/spray nozzle, 22mm. isolating valve and all other necessary fixing accessories including Fabrication and Erection ofM.S. Support, as per requirement, for Fixing the Fire Hose Reel Set. |
| 3 | od105107/2021_2022 : Supply, installation, testing and commissioning ofFire Hydrant Valve,bearingto ISI:5290 Type-A mark, Stainless Steel-304 body with 63mm. oblique instantaneous single outlet, 75mm. N.B. flanged inlet, Stainless Steel -304 spindle, complete with PVC blank cap, G.I. chain etc. |
| 4 | od105108/2021_2022 : Supply, installation, testing and commissioning ofFire Brigade Inlet Breeching, C.I. body, having 3 Gunmetal, 63mm. male instantaneous inlet, conforming to IS: 903, with non return valves, 25mm. drain valve, flanged outlet, 3 nos. of rubber blank caps and G.I. chains. |
| 5 | od105109/2021_2022 : Supply, installation, testing and commissioning of Fire Hose, RRL hose jacketed with circular woven synthetic fiber. conforming to IS: 636:88, with Working Pressure 14 Kg/Cm2, Proof Pressure 22 Kg / Cm2 and Burst Pressure 38 Kg / Cm2. The Fire Hose shall be with IS: 636 Type-A marking and63mm. dia. x 15 Meter long withpair of63mm. male and female instantaneous couplings, Stainless steel - 304,having IS: 903 mark and duly S. S. wire wounded. The hose shall be rolled and hung to suitable M. S. support in the Fire Station. |
| 6 | od105110/2021_2022 : Supply, installation, testing and commissioning of Branch Pipe, Stainless Steel-304,short type, with 63mm. male instantaneous inlet, male threaded outlet, fitted with 16mm. bore nozzle, having IS: 903 mark. |
| 7 | od105111/2021_2022 : Supply and fix at site in position Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and as per requirement. |
| 8 | od105112/2021_2022 : Supply and fix at site in position Weather Proof Fire Hose Cabinet, wall / pole mounting type, 30” x 24” x 10” size, to accommodate two 15m length of delivery hose and branch pipe, acrylic fronted double door, with lock, 2 keys and a break glass recess for keys, painted Fire Red. The price shall be inclusive of fixing accessories and pole for mounting, all as per requirement. |
| 9 | od105113/2021_2022 : Providing, Fixing,testing and commissioning of Flow Switch, Vane type, IP 65 Protection with 20 Bar Working Pressure Protection with all necessary accessories, for monitoring Fire Sprinkler System. The control cabling from flow switches to Fire Sprinkler Annunciating Panel shall be measured separately. |
| 10 | FIRE PUMPS AND ACCESSORIES |
| 11 | od105114/2021_2022 : TERRACE PUMP -Supply, erection, testing & commissioning of electrical motor driven Booster Pump of Monoblock type capable to deliver 450LPM at 35 MWC.The pump will be coupled to TEFC motor with speed of 2900 RPM and complete setmounted on common base frame. The quoted rate includes providing & fixing of Pressure gauge, Pressure switch, and Foundation bolts etc. |
| 12 | od105115/2021_2022 : MOTOR CONTROL PANEL - Supply, installing, testing and commissioning of compartmentalisedcontrol panel for Terrace Boster pump with all accessories required formplete instalation as directed by the Engineer in charge. The panel include necessary starter, controls, connections and interconnection etc. as required. |
| 13 | FIRE PIPES, VALVES & ACCESSORIES |
| 14 | od105116/2021_2022 : Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and But welded fittings for pipes above 50mm including pump room with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification.<br>80 mm |
| 15 | od105118/2021_2022 : Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and But welded fittings for pipes above 50mm including pump room with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification.<br>100 MM |
| 16 | od105122/2021_2022 : Hydrant, Sprinkler System & Plant Room : Providing, fixing, pressure testing and commissioning ofAbove Ground Fire Line Pipe Work with Heavy Duty (Class-C) Galvanized Steel Pipes, confirming to IS: 3589/1239 Part - I and with Heavy Duty Galvanized Ductile Iron Screwed Fittings for Pipes up to 50mm diameter and But welded fittings for pipes above 50mm including pump room with all accessories required for complete installation such as tees, elbows, reducers, check nuts, unions, flanges, nipples and neoprene gasket, bolts, nuts, washers etc. including cutting, threading, grooving, joining, fixing in ducts, on walls, ceiling etc. by using suitable and strong enough supports, as per requirement, providing higher sizes of Sleeves/Opening, wherever required, and closing the gap between the pipes and sleeves/openings with 2 Hr. Fire Rated compound / sealant to the approval of Engineer - in - Charge /Consultant. The total pipe work shall be protected with approved painting system as per technical specification. All Pipe Fittings shall be UL Listed and FM Approved, as per the technical specification.<br>150 MM |
| 17 | od105123/2021_2022 : Under ground piping: Supply, installation, Testing and Commissioning of G.I"C" class pipesof following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials.The rate is inclusive of excavation up to a depth of 1.5 m & wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistant tape as per IS : 10221 with 15 mm overlap.<br>80 MM |
| 18 | od105124/2021_2022 : Under ground piping: Supply, installation, Testing and Commissioning of G.I"C" class pipesof following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials.The rate is inclusive of excavation up to a depth of 1.5 m & wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistant tape as per IS : 10221 with 15 mm overlap.<br>100 MM |
| 19 | od105125/2021_2022 : Under ground piping: Supply, installation, Testing and Commissioning of G.I"C" class pipesof following sizes conforming to IS1239 with fabricated welded joints with neccessary fittings/ specials.The rate is inclusive of excavation up to a depth of 1.5 m & wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistant tape as per IS : 10221 with 15 mm overlap.<br>150 MM |
| 20 | od105126/2021_2022 : Providing, fixing, testing and commissioning of Forged Ball Valve, PN-20 gunmetal /cast alloy, including necessary accessories and connections.<br>25 MM |
| 21 | od105127/2021_2022 : Providing, fixing, testing and commissioning ofButterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. <br>80 MM |
| 22 | od105128/2021_2022 : Providing, fixing, testing and commissioning ofButterfly Valve, PN-16, slim seal, standard lever operated type confirming to BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete. <br>150 MM |
| 23 | od105129/2021_2022 : Providing, fixing, testing and commissioning ofNon Return Valve, Wafer Swing Check type, PN-16, conforming to IS: 13095 withrequired companion flanges nuts, bolts etc. complete. <br>150 MM |
| 24 | od105130/2021_2022 : Supply, installation, testing and commissioning ofAir Release ValveGunmetal, conforming to IS 903:1993, having rubber ball with sealing seat and with 25mm. BSP threaded male inlet, including necessary accessories and connections. |
| 25 | od105131/2021_2022 : Providing and fixing C. I.GateValve with Non Rising Stem & Cap Top, PN-16, confirming to IS: 14846 with ISI Mark and with required companion flanges, rubber insertions, bolts, nuts, Washers etc. complete. The Price shall be inclusive of ‘Fabricated Key' for Operation from Ground Level, as per Technical Specifications.<br>100 MM |
| 26 | od105132/2021_2022 : Providing and fixing C. I.GateValve with Non Rising Stem & Cap Top, PN-16, confirming to IS: 14846 with ISI Mark and with required companion flanges, rubber insertions, bolts, nuts, Washers etc. complete. The Price shall be inclusive of ‘Fabricated Key' for Operation from Ground Level, as per Technical Specifications.<br>150 MM |
| 27 | od105133/2021_2022 : Supply, installation, testing and commissioning of 4" dia. Bourdon Type Pressure Gauge, with ISI Mark orof equivalent International Standards.<br>Standard Type for indoor use with shut off cock and connection Pipe |
| 28 | CONVENTIONALFIRE ALARM SYSTEM |
| 29 | od105134/2021_2022 : Supply, Installation, Testing and Commissioning of micro processor based Fire Alarm Control Panel with fire and fault audio visual indication, test, reset and isolation feasibility with built in battery charger and battery with fully assembled and wired for 10 zone. |
| 30 | od105135/2021_2022 : Providing, fixing test and commission Conventional typeManual Call Station Point with analogue module that monitors and reports contact status, all as per technical Specifications. |
| 31 | od105136/2021_2022 : Providing, fixing, test and commissionConventional type Weather/Water Proof/Corrosion Resistant type Analogue Manual Call Point having an integrally mounted analogue module that monitors and reports contact status, IP67 rated, complete as per technical specifications. |
| 32 | od105137/2021_2022 : Providing, fixing, test and commission Conventional Type Horn/Strobe rated at 82 dB @3Mtr. for audible annunciation and 75Candela flashing at 1Hz. for visual indication, complete as per technical specifications. |
| 33 | od105138/2021_2022 : Providing, fixing, testing and commission Weather/Water Proof/ Corrosion Resistant Conventional Type Horn/Strobe, Rated at 82 dB @3Mtr. for audible annunciation and 75Candela flashing at 1Hz. for visual indication, IP: 66 Rated, complete as per technical specifications. |
| 34 | od105141/2021_2022 : Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Red Colour / Finish,as per Technical Specifications. |
| 35 | FIRE EXTINGUISHERS |
| 36 | od105142/2021_2022 : Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.<br>ABC Dry Chemical, Store Pressure Type - 2 Kg. |
| 37 | od105143/2021_2022 : Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.<br>ABC Dry Chemical Powder, Store Pressure Type - 4 Kg. |
| 38 | od105144/2021_2022 : Providing, fixing, commission and install in position following Portable Fire Extinguisher as per BIS 2190 and BIS: 15683:2006 and with relevant ISI Stamping/Marking.<br>Fire Bucket including Fabricated M. S. Stand |
| 39 | TALK BACK SYSTEM |
| 40 | od105145/2021_2022 : Supply, installation, testing & commisioning of automatic control console of 8 zones micro process based complete with floor to floor announcing and talk back facilities with the following features and made functional: (a) Feather type key pads to select the zones. (b) Moulded plastic attractive enclosure. (c) Backlight Liquid Crystal Display (LCD) (d) User friendly interactive display. (e) Announcement selector - PH Switch. (f) Listen selector switch. (g) All Call switch to select all zones simultaneously for announcement (h) Zones Call Display On the LCD With Audio Alarm. Panel to be installed in the Fire |
| 41 | od105147/2021_2022 : Controller Unit with 120 W amplifier, Goose neck type microphone and with the following features: (i) Built in Power supply. (ii) Zone Selector switching Circuit (iii)Terminal blocks to terminate zones wires, amplifier wires etc., (iv) Zone Call processing Circuit etc and made functional. Panel to be installed in the Fire Control Room. |
| 42 | od105148/2021_2022 : Supply, installation, testing and commisioning of Public Address speaker with talk back facility 6 Watts with L M T and call switch, made out of powder coated CRCA sheet, wall mounting type and to be installed at a height of not less than 150 CM from the finished floor levels, suitable for concealed mounting. |
| 43 | od105149/2021_2022 : Providing, fixing / laying, test and commission 2Core x 1.5 mm2 FRLS Armored Cables with Red Colour / Finish,as per Technical Specifications. |
| 44 | SIGNAGES |
| 45 | od105150/2021_2022 : Fire Exit Light - Laser type, with High Glow LED Light, size: 12” x 6” or nearby, Ceiling Mounting type with hanging clamps, on/off switch, Red / Green Colour option, power consumption: 18 Watt or less with all accessories required for complete installation as directed by the engineer inc charge. Power supply shaould be provided with UPS back-up. |
| 46 | od105151/2021_2022 : Supplyand install in position following Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engieer in charge.<br>Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm. |
| 47 | od105152/2021_2022 : Supplyand install in position following Sign Boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners with all accessories required for complete installation as directed by the Engieer in charge.<br>Floor Identification Signage (MAIN STAIRCASE, FIRE STAIRCASE, FIRE ASSEMBLY POINT, PUMP ROOM, FIRE CONTROL ROOM, ELECTRICAL ROOM, FIRE LIFT, PASSENGER LIFT Etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm.<br>Supply and install in position the Signage "FIRE ORDER" it should contain the matter specified in the technical details on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2' x 3'. |
| 48 | MISCELLANEOUS WORKS |
| 49 | od105153/2021_2022 : Constructing masonry Valve Chamber in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice / gate valve, including all supports for fixing valve, with Heavy Duty C.I. cover and frame, i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design<br>Internal Size: 60 x 60 x 75cm, deep |
| 50 | od105155/2021_2022 : Fabrication, supply, installation at site Heavy Duty Galvanized MildSteel Puddle Flange, Fabricated from Heavy Grade M. S. Pipe, confirming to IS: 1239/ 3589, with PN:20 Drilled M.S. Flange(s), as per Table BS-10 and M.S. Plate, all as per tender drawings and technical specifications, provided. After total fabrication, the puddle flange should be hot dipped galvanized to IS: 4759 and further protected with Epoxy Coating to the approval of the Engineer - in - charge and Consultant.<br>150mm.dia, 700mm. Long. |
| 51 | WATER TANK |
| 52 | 2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 53 | 4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) |
| 54 | od103416/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.<br>All work upto plinth level |
| 55 | od103417/2021_2022 : Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 340 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.<br>All work above plinth level upto floor V level |
| 56 | 5.33.1 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level |
| 57 | 5.33.2 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level |
| 58 | 5.3 : Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). |
| 59 | 5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 60 | 5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 61 | 5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 62 | 5.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 63 | 5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts |
| 64 | 5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 65 | 10.26.3 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes |
| 66 | 13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) |
| 67 | 51.13.21.1 : Water proof plasteringwith Cement Mortar 1:4 (1 cement : 4 fine sand) 12mm thick plaster finished with a floating coat of neat cement mixed with water proofing compound of approved make@ 2kg/m2 of mix floated hard and troweled smooth including all labour, material, conveyancecharges etc complete. |
| 68 | 13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) |
| 69 | 13.44.1 : Finishing walls with water proofing cement paint of required shade:New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 70 | 13.62.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to givean even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture . |