| 1 | Dismantling single layer of Mangalore pattern tiles in roofing complete all as specified and as directed by Engineer in charge. |
| 2 | Taking downcement mortar bed including cement plaster/PCC beading etc from sloped RCC roof surfaces at a height upto 12mtrof anydescription/any thickness including cleaning with water etc complete all as specified and as directed by Engineer in charge.NOTE for item Nos 1&2:- (a)All debris, unserviceable items shall be removed from site and thrown away at dumping area upto 5 Km inside INA area where directed. Loading, unloading, staking and transportation charges etc shall be included in the qouted rate.(b)The work shall be executed on slope roof/flat roof upto a height of 12m.(c)Old serviceable MP roof tiles & ridge tiles obtained from item No. 01 shall be re-fixed at any other buildings roof upto a distance 5 Km. Therate quoted shall be deemed to be included all elements for the same including transportation. |
| 3 | DismantlingPlain or corrugated steel sheeting, any gauge, thickness, including Nainitalor similarpattern roof coverings as directed by Engineer in charge. |
| 4 | Dismantling unframed timber scantlings 40 Sqcm and over in section, in any position as directed by Engineer in charge. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directedby Engineer in charge. |
| 6 | Demolition of plain cement Concrete (unreinforced) of any description and in anypositionnot otherwise specifically provided for includung existing roof treatment, roof PCC tiles etc. complete all as specified and as directed. |
| 7 | Taking down existing water proofing treatment of any description and removal rubbish off the premises, complete all as specified and as directed by Engineer in charge. |
| 8 | Demolition of brickwork or Pre-cast cement concrete block masonry, built in cement mortar complete all as specified and directed. |
| 9 | Taking down cement plaster on brick/ PCC block wall or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed by Engineer in charge. |
| 10 | Demolition floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises, complete all as specified. |
| 11 | Dismantling CI soil waste pipe 100mm dia including all joints and branch piecesjointed in cement mortar complete all as specified and directed. |
| 12 | All as per item No. 11 above but 75 mm dia. |
| 13 | Dismantling water tanks exc. 500 ltrs but not exc. 1000 ltrs capacity and removing to store |
| 14 | M&L for applying cement slurry with 3.0kg of cement per sq. metre over existing RCC roofcomplete all as specified and as directed by Engineer in charge. |
| 15 | M&L for screed bed/ Rendering 15mm thick on fair faces ofconcrete surfaces in CM (1:3 ) mixed with liquid water proofing compound as per manufacturer\"s instruction complete and finishing the surface even and smooth without using extra cement all as specified and as directed by Engineer in charge.( NOTES :-(a) water proofing compund will be meausred and paid seprately.(b)Therate quoted shall be deemed to be included necessary scafolding etc as required) |
| 16 | M&L for two coat of Dr. Fixit Roof seal top coat waterprofing ovet a coat of self priming complete all asper manufacturer\"s instruction and as directed by Engineer in charge. |
| 17 | Supply only Liquid water proofing compound complete all as specified. MAKE :- ROFFEE HYPROOF of Roffee construction chemicals pvt.ltd/Conplast PROLAPIN 421 IC of FOSROC chemicals or equivalent make approved by GE. |
| 18 | S&F Galvanised Iron framed work for fixing of mangalore pattern tiles over existing RCC slopping roof with any type of sectionsincluding necessary welding, bolting, reveting etc complete all as specified and as directed by Engineer in charge. |
| 19 | S&F plain plates channels. Square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment (Fe-410W, Gde E-250, Qlty-A) |
| 20 | S&F 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed by Engineer in charge. |
| 21 | S&F 0.5 mm thickPre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, ridge, valley gutter etc. fixed with self tapping screws complete all as specified and as directed by Engineer in charge. |
| 22 | M&L for Preparation of newsteel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer. |
| 23 | M&L forpreparation of newsteel surfaces of any description n. exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer. |
| 24 | Re-fixing roof tiles mangalore pattern interlocking tiles including cleaning the tiles with wire brush and washing with water jet to remove all fungals etc completeall as specified and as directed by Engineer in charge. |
| 25 | M&L roof tiles Mangalore pattern interlocking at side joints, laid dry complete all as specified and as directed. |
| 26 | M&L Ridge or hip tiles to suit Manglore pattern or roofing tiles bedded and jointed in cement mortar 1:6complete all as specified and as directed |
| 27 | S&FClay terracotta ceiling tiles complete complete all as specified and as directed by Engineer in charge. |
| 28 | M&L for preparation of old MP roof tile surfacesand applying one coats of antifungal tile guardpaintto match with the existing colour complete all as per manufacturer\"s instructions and as specified. |
| 29 | M&L for preparation of new MP roof tileand applying two coats of antifungal tile guardpaintof approved colour complete all as specified and as per manufacturer\"s instructions. |
| 30 | M&L forPCC 1:2:4 type B-1 (20mm graded aggregate) as in levelling course, roof kerbs, coping etc. using water proofing compound and finishing the surface even and smooth complete all as specified and as directed. NOTE :- water proofing compund will be meausred and paid seprately. |
| 31 | M&Lfor preparation of roof surface by throughly wire brushed, washed, dried up, cleaned of all the foreign matter and dust, and applying bitumenous primer @ 250 gms/sqm, and then laying 4mm thick APP modified bituminous membrane with non woven polyester matt as reinforcement weighting not less than 4.00Kg per sqm, laid on primed surface with torch application method by providing overlap minimum 100mm on logitudinal and 150mm on transerve direction,and finishing the surface with solar reflective bituminous aluminium paint at the rate of 100 grams per sqm with preparation of treated surfaces, all angles and similar projections should be sealed well with extra care to ensure full bondage, all joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR Latex @ 200ml/bag of cement. |
| 32 | M&L for Pre-cast cement concrete block masonry type C1 1:3:6 (using 20 mm aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified |
| 33 | M&L for Rendering 15mm thick on fair faces of brick work or stone work, concrete surfaces in CM (1:4 )with liquid water proofing compound complete all as specified and as directed. NOTE :- water proofing compund will be meausred and paid seprately. |
| 34 | M&L for preparation of new surfaces and applying two coats of sandtex matt finish paint over a coat of primer to external wall/ Chajja/ Roof projection etc complete all as specified and as per manufacturers instructions. |
| 35 | M&L cement concrete type D2 1:4:8(using 40mm graded aggregate)as in sunken floor filling complete all as specified and as directed. |
| 36 | M&L, coloured Non-skid ceramic tiles (square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 15 mm thick screed bed in CM 1:6 all as specified. |
| 37 | M&L Glazed ceramic coloured tiles 300 x 200 x 6 to 7mm thick in vertical surfaces of stone/brick wall, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick backing coat plaster in CM 1:4 all as specified. |
| 38 | S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints,laid in trenches or floor (Work in foul condition and in shaft) complete all as specified and directed. |
| 39 | Ditto all as per item No. 38 herein before but fixed to walls. |
| 40 | S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints,laid in trenches or floor (Work in foul condition and in shaft) complete all as specified and directed. |
| 41 | Ditto all as per item No. 40 herein before but fixed to walls. |
| 42 | S&F 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement concrete complete all as specified and directed. |
| 43 | S&F in repair PVC (SWR) \"S\" Trap for 110 mm dia of pipe all as specified. |
| 44 | S&F PVC (SWR) bends 110mm dia any radius(Work in foul condition and in shaft) complete all as specified and directed. |
| 45 | S&F PVC (SWR) bends 75mm dia any radius(Work in foul condition and in shaft) complete all as specified and directed. |
| 46 | S&F 110 mm PVC (SWR) Branch pieces single (equal or unequal) with parallel branches (Work in foul condition and in shaft) complete all as specified and directed. |
| 47 | S&F 75 mm PVC (SWR) Branch pieces single (equal or unequal)with parallel branches (Work in foul condition and in shaft) complete all as specified and directed. |
| 48 | S&F 75 mm PVC (SWR) junction single (single T) equal or unequal (Work in foul condition and in shaft) complete all as specified and directed. |
| 49 | S&F 110 mm PVC (SWR) junction single (single T) equal or unequal (Work in foul condition and in shaft) complete all as specified and directed. |
| 50 | S&F 110 mm PVC (SWR) vent cowl (Work in foul condition and in shaft) complete all as specified and directed. |
| 51 | S&F 75mm mm PVC (SWR)vent cowl (Work in foul condition and in shaft) complete all as specified and directed. |
| 52 | S&F in repair vitreous china, wash down water closet(EWC), white with seat cover, closed pattern with flat bottom and cover with mild steel (CP) or aluminium hinging device fixed with necessary bolts complete all as specified. |
| 53 | S&F in repair PVC valve less syphonic action type flushing cistern low level with inlet ball valve float and handle including brackets 10 ltrs capacity. |
| 54 | S&F in repair chromium plated health faucets (hand held shower type) with shut off valve (thumb or push button type) to allow controlled and continuous flow of water with adequate length and wall mounted pedestal for hanging the faucet etc complete all as specified. |
| 55 | S&F in repair vitreous China wash basin, white flat back 550x400mm including pillar tap and waste coupling CP,fixing brackets, cutting for and pinning in ends of brackets all as specified. |
| 56 | S&F 32mm dia PVC flexible waste pipe for urinals/WHB/sink all as specified |
| 57 | S&F in repair angular stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for union and fixed, suitable for 15 mm bore pipe,complete all as specified. |
| 58 | S&F in repairs 15mm bore chromium plated bib taps (fancy type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes all as specified. |
| 59 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm. |
| 60 | Taking up or down steel tubing and connections, 25 or 32 mm bore complete all as specified and as directed. |
| 61 | S&F 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed on walls/ceiling or laying in floors complete all as specified. |
| 62 | S&F 32mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed on walls/ceiling or laying in floors complete all as specified. |
| 63 | S&F Rotational moulded polythene water storage tanks 750 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified including dismantling of old U/s water tank and removing from site complete all as specified and as directed. |
| 64 | S&F in repair25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms) all as specified. |
| 65 | NOTES:- (a)All debris, unserviceable items which are not included in schedule of credit shall be removed from site and thrown away at dumping area upto 5 Km inside INA area where directed by Engineer- in Charge. Loading, unloading, stacking and transportation charges etc for removal of debris shall be deemed to beincluded in relevent items of taking down, dismantling, demolition etc.(b)The work shall be executed on sloped roof/flat roof upto a height of 12m with proper scaffolding. |