Repair / Maintenance Of Dg Set, Amf / Lt Panel And Its Connected Items At Makarpura Af Stn Baroda-1 Old Unserviceable Gi Pipe Of Size Of 40 / 50 Mm Bore Dia. Rm 48 50.00 2400.00 2 Old Unserviceable Bricks Any Size Each 8000 1.00 8000.00 3 Old Un

Tender Notice

29571102
Corrigendum : Repair / Maintenance Of Dg Set, Amf / Lt Panel And Its Connected Items At Makarpura Af Stn Baroda-1 Old Unserviceable Gi Pipe Of Size Of 40 / 50 Mm Bore Dia. Rm 48 50.00 2400.00 2 Old Unserviceable Bricks Any Size Each 8000 1.00 8000.00 3 Old Un
Indian
Gujarat
04-11-2021
11-11-2021
13-11-2021

Tender Details

Repair / Maintenance Of Dg Set, Amf / Lt Panel And Its Connected Items At Makarpura Af Stn Baroda-1 Old Unserviceable Gi Pipe Of Size Of 40 / 50 Mm Bore Dia. Rm 48 50.00 2400.00 2 Old Unserviceable Bricks Any Size Each 8000 1.00 8000.00 3 Old Unserviceable Of Lt Underground, Cable 50 Sqmm 3.5 Core To 120 Sq Mm 3.5 Core Rm 900 20.00 18000.00 4 Old Unserviceable Of Lt Underground, Cable 16 Sqmm 3.5 Core To 25 Sq Mm 3.5 Core Rm 500 15.00 7500.00 5 Old Unserviceable Of Lt Underground, Cable 10 Sqmm 2 Core Rm 150 10.00 1500.00 6 Old Unserviceable Straight Through Joint Any Type Each 12 10.00 120.00 7 Old Unserviceable Mccb 63 / 100 / 160 / 200 / 250 Amps Each 18 25.00 450.00 8 Old Unserviceable Aluminium Cable Lugs Any Size Each 299 2.00 598.00 9 Old Unserviceable Mcb Each 10 2.00 20.00 10 Old Unserviceable Voltmeter / Ammeter / Avf Meter Each 5 25.00 125.00 11 Old Unserviceable Selector Switch Each 3 2.00 6.00 12 Old Unserviceable Phase Indicator Lamp Each 5 1.00 5.00 13 Old Unserviceable Ct Coils Each 2 5.00 10.00 14 Old Unserviceable Capacitor Any Type Each 7 50.00 350.00 15 Old Unserviceable On Load Changeover Switch Each 1 50.00 50.00 16 Old Unserviceable Long Travel Limit Switch Each 1 5.00 5.00 17 Old Unserviceable Cross Travel Limit Switch Each 1 20.00 20.00 18 Old Unserviceable Brake Unit For Hoising Each 1 20.00 20.00 19 Old Unserviceable Single Phase Preventer Each 2 5.00 10.00 20 Old Unserviceable Brake Set Each 2 10.00 20.00 21 Old Unserviceable Gear Oil / Engine Oil Ltr 165 5.00 825.00 22 Old Unserviceable Push Button Each 4 2.00 8.00 23 Old Unserviceable Air Termination Aluminium Rod Each 25 2.00 50.00 24 Old Unserviceable Test Point Terminal Block Each 5 2.00 10.00 25 Old Unserviceable Air Filter Each 18 10.00 180.00 26 Old Unserviceable Lube Oil Filter For Generator 25 Kva - 62.5 Kva Each 14 5.00 70.00 Ca No.Ge ( Af ) / Brd / Of 2021-22 Serial Page No.23 ( Schedule Of Credit ) ……..Contd S. No Description Of Item Of Works Unit Qty Rate ( Rs. ) Amt ( Rs. ) 27 Old Unserviceable Fuel Filter Filter For Generator 25 Kva - 62.5 Kva Each 19 5.00 95.00 28 Old Unserviceable Fuel Pipe Rm 20 5.00 100.00 29 Old Unserviceable Oil Water Pressure Gauge Each 2 15.00 30.00 30 Old Unserviceable Pressure / Ignition Switch Any Type Each 3 5.00 15.00 31 Old Unserviceable Indicating Lamp Each 10 2.00 20.00 32 Old Unserviceable Battery Terminal Heavy Duty Of Brass. Each 12 5.00 60.00 33 Old Unserviceable Fan Belt. Each 5 2.00 10.00 34 Old Unserviceable Self Starter 12 / 24 Volts Each 2 50.00 100.00 35 Old Unserviceable Turbo Charger Assembly Each 1 100.00 100.00 36 Old Unserviceable Fuel Injector Pump Each 1 100.00 100.00 37 Old Unserviceable Avr Each 1 50.00 50.00 38 Old Unserviceable Battery Lead Each 5 5.00 25.00 39 Old Unserviceable Solenoid Valve Each 1 10.00 10.00 40 Old Unserviceable Engine Coupling Each 1 25.00 25.00 41 Old Unserviceable Battery 12 Volt Any Type Each 4 1500.00 6000.00 42 Old Unserviceable Supply Failure Timer Each 2 5.00 10.00 43 Old Unserviceable Restoration Timer . Each 1 5.00 5.00 44 Old Unserviceable Auxiliary Contactor Each 2 5.00 10.00 45 Old Unserviceable No / Nc Contact Each 10 2.00 20.00 46 Old Unserviceable Under Voltage Relay Each 3 5.00 15.00 47 Old Unserviceable Time Delay Relay Each 1 2.00 2.00 48 Old Unserviceable Contractor Any Type Each 5 25.00 125.00 49 Old Unserviceable Battery Charger Amf Panel 12 / 24 Volt . Each 2 25.00 50.00 50 Old Unserviceable Controller Each 3 10.00 30.00 51 Old Unserviceable Avr Each 2 15.00 30.00 52 Old Unserviceable Contactor Relay Any Type Each 6 100.00 600.00 Ca No.Ge ( Af ) / Brd / Of 2021-22 Serial Page No.24 ( Schedule Of Credit ) ……..Contd….. S. No Description Of Item Of Works Unit Qty Rate ( Rs. ) Amt ( Rs. ) 53 Old Unserviceable Fuse Holders & Fuse Bases Any Type Each 10 10.00 100.00 54 Old Unserviceable Fuse Links

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Nov-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 11-11-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 29000.00 /-
Tender Value
INR 14.50 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINTENANCE OF DG SET, AMF/LT PANEL AND ITS CONNECTED ITEMS AT MAKARPURA AF STN BARODA
Sl. No. Item Description
1Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed
2Returning , filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
3Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
4M&L for sand cushioning to PVC cable with using clean dry and natural river sand and gently punning down below/around cable complete all as specified and directed. Note : Punned thickness shall be measured for payment.
5Supply, laying and fixing galvanised iron pipe light grade, laid under roads/ drain / along with the pole /fixing of airtermination rodwith flat iron clamps, bolts, nuts washers complete all as specified and directed of following size:-
6Size of 40 mm bore dia.
7Size of 50 mm bore dia.
8Supply and fix cable cover, class LV, flat, size 190mm x 90mm x 90mm as in protection of cable laid dry, flat, abutting each other width wise complete all as specified and directed.
9Supply, laying, jointing and testing of LT underground, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, Heavy duty, electric power cable laid in trenches/ ducts/fixed on pole/ wall / laid under road / path / culvert / drains / culverts encased in GI pipe, electric cable with aluminium stranded conductor, including jointing and testing 1100 volts grade with necessary lugs and compression brass glands including taking down old cable complete all asspecified and directed.
10120 Sq mm 3.5 core
1195 Sqmm 3.5 core
1270 sqmm 3.5 core
1350 sqmm 3.5 core
1425 Sq mm 4 Core
1516 sqmm 4 core
1610 sqmm 2 core
17M&L for straight through joint outdoor type for LT UG cable including jointing kits heat srinkable typecomplete suitable for aluminium conductor cables complete all as specified and directed of the following size.
18Size of 25 to 50 sqmm3.5 core
19Size of 70 to 95 sqmm3.5 core
20Size of 120 to 185 sqmm3.5 core
21M&L forfixingMCCB 4 Pole 63 AmpsConforms to IS/IEC 60947-2,IEC 60947-2 & EN 60947-2,Ics=100% of Icu,Common SS Enclosure with Thermal Magnetic Release, 415 volts, 10 KA complete all as specified and directed.
22M&L forfixingMCCB 4 Pole 100 AmpsConforms to IS/IEC IS/IEC 60947- & IEC 60947-2,Ics=100% of Icu,Common SS Enclosure with Thermal Magnetic Release, 415 volts, 25 KA complete all as specified and directed.
23M&L forfixingMCCB 4 Pole 160 AmpsConforms to IS/IEC IS/IEC 60947- & IEC 60947-2,Ics=100% of Icu,Common SS Enclosure with Thermal Magnetic Release, 415 volts, 25 KA complete all as specified and directed.
24M&L forfixingMCCB 4 Pole 200 AmpsConforms to IS/IEC IS/IEC 60947- & IEC 60947-2,Ics=100% of Icu,Common SS Enclosure with Thermal Magnetic Release, 415 volts, 25 KA complete all as specified and directed.
25M&L forfixingMCCB 4 Pole 250 AmpsConforms to IS/IEC IS/IEC 60947- & IEC 60947-2,Ics=100% of Icu,Common SS Enclosure with Thermal Magnetic Release, 415 volts, 25 KA complete all as specified and directed.
26M&L forfixingMCCB 4 Pole 400 AmpsConforms to IS/IEC IS/IEC 60947- & IEC 60947-2,Ics=100% of Icu,Common SS Enclosure with Thermal Magnetic Release, 415 volts, 50 KA complete all as specified and directed.
27Supply and fixAluminium cable lugs ( lugs are made from 99.5% pure aluminium) as per IS of following Size;-
28185 Sq mm
29120 Sq mm
3095 Sqmm
3170 sqmm
3250 sqmm
3335 sqmm
3425 Sq mm
35Supply and fix MCB, single pole and neutral link240 volts 40 to 63 Amps capacityC series fixed inLT panel including taking down old unserviceable MCBs.complete all as specified and directed.
36Supply and fixVoltmeter digital type accuracy Class 1.0, 0.5, Input voltage measurement range 50-520 VAC (P-P), Aux supply 80-300 VAC,CT secondary site selectable 1A / 5A,Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters.complete all as specified and directed.
37Supply and fixAmmeter digital type accuracy Class 1.0, 0.5, 1A / 5A,Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters.complete all as specified and directed.
38Supply and fix AVF meter(amper,Volt and Frequency meter ) digital type accuracy Class 1.0, ,Flush mounting 96 x 96 mm, Inbuilt selector switch for 3 phase meters.complete all as specified and directed.
39Supply and fixSelector switch for voltmeter/ ammeter .complete all as specified and directed.
40Supply and fixSPhase indicator lamp neon type complete with holder assy RYB complete all as specified and directed.
41Supply and fixCT coils of range .200/5 Amp complete all as specified and directed.
42Servicing and repair to APFC Panel 75 to 125kvar Capacity Complete wiring with Suitablecopper wire ISI marked withindicating Lamp, Ampere Meter, voltmeter and required items for working Conditioncomplete all as specified and directed. Note :- Spares should measures and Paid Separetely
43Capacitor cylinderical type 5 to 25KVAR capacity complete all as specified and directed.
44Capacitor 20 to 25KVAR capacity.complete all as specified and directed.
45M&L in replacement for on load changeover switch of capacity 200 amps 4 pole including removing old changeover switch any type and necessary fixing on wall/in LT panel complete all as specified and directed. complete all as specified and directed.
46Servicing / repair including preventive check and operatioal checkof 2 ton EOT crane fordismantling of hoisting gear box, drain of old oil, cleaning of gear box, fill up fresh oil in gear box. Long travel, cross travel gear box oil check up and fillingoil. Checking of hoisting, long travel, cross travel, break unit, shifting of berak unit, oiling of break unit pins. Greasing in long travel cross travel wheel bearing, Checking of panel board and connections, Overhauling of PPB, Greasing on Wire rope Drum , checking of push button connections checking of power festooning cable checking of long travelo rail alignment, checking of cross travel rail alignment Bottom block assembly(hook assembly) cleaning, checking and oiling Greasing of wire rope, rope drum, pedestal bearings including load test using dead weight,duly sign by user and sumbit to AGE E/M office timely complete all as specified and directed.
47Note :- (i) Contractor will provided necessory oil, grease, cloth waste and Minor Spares Required will Be Deemed to be included in Quoted rate. (ii) Load Test will be carried out after Completion of the Entire work and a Certificate duly Signed by the user will be Submitted by the Contractor. (iii) The Contractor will give one Year Gurantee from the Date of Completion of Work in writing. (iv) Spares should be measured and paid separetely. (v) Operational check carried out by competent person of authorised firm only.
48Supply and fixing the following spares in replacement/ fixing at site for EOT/ HOT crane complete all as specified and directed.
49Long travel limit switch
50Crosstravel limit switch
51Brake unit for hoising
52Single phase Preventor
53brake Set
54Gear oil
55Push Button
56Servicing / repair including preventive check and operatioal checkof1.5 to 2 ton HOT crane for oiling and Greasing of long travelo rail alignment, checking of cross travel rail alignment Bottom block assembly(hook assembly) cleaning, checking and oiling Greasing of wire rope, rope drum, pedestal bearings complete all as specified and directed. NOTE :- including load test using dead weight,duly sign by user and sumbit to AGE E/M office timely complete all as specified and directed.
57Note:- (i) Contractor will provided necessory oil, grease, cloth waste and Minor Spares Required will Be Deemed to be included in Quoted rate. (ii) The Contractor will give one Year Gurantee from the Date of Completion of Work in writing. (iii) Spares should be measured and paid separetely.
58Material and labour only for watering (by means of water tanker) the existing earthing pit at makarpura airforce station and measuring of earthing in ohms and writing the result at near place by applying black paint at base writing the result in yellow with date of measurement and next due date near each panel and transformer/any other place by disconnecting the earthing strip from terminal/junction and reconnection after measurement of result and mainting the resister duly signed by user,contractor complete all as specified and directed. NOTE :- (i) contractor shall quote the rates by including the charges of making arrangement of watering the earthing pits at any site and location inside Airforce makarpura area. (ii) Also, contractor shall bring his own measuring instruments whatever is required to carry out the job. (iii) cleaning or replacing the exisiting sticker and writing the new as on date data on exisiting test result board on site shall be inclusive of the quoted rates. (iv) Contractor shall take before permission for watering earth pitto user intimation for detailment ofreprasentive. Obtainuser signature is responsibility of contractor.
59M& L for making proper connection of loose/hanging lighting arrester aluminium /Copper / G I strip strip on existing position with porcelain saddles ,brass screw including drilling and fixing with entire satisfaction to engineer in charge . Note . Rate included in any height of Bldg (Roof /Wall etc) after completion signature obtained by the User is the responcibility of Contractor. Note :Contractornot completed the work before completion a recovery of 2 times of quoted rate shall levied.
60S&F in repairs Air termination single pointed, Aluminium rod 12mm dia and 300mm long complete all as specified and directed.
61S&F in repairs Test point terminal block made of MS powder coated MS Sheet of 1.6mm thick sheet of size 230X230X 75mm drilled and screwed including terminals for two strips entry and exit with overlapping for testing earth result complete all as specified and directed.
62Labour only for servicing of DG set including replacement of fuel filters,oil filters,air filter element,changing oil,cleaning fuel lines,checking leakage and repairing it,replacement of exhaust main fold gasket etc all as specified and directedas per manufacturer/authorised service centre for the following:- Note. .Rate quoted shall be included i) Checking of Battery specific gravity every month and the acid level once in Three month and top with distilled water if required. (Applicable for lead acid Battery only). Output voltage check and condition check to be carried out in SMF type battery ii) Checking charging alternator output voltage with respect to specifications iii)To check the condition of Diodes/ rotating rectifier etc. iv)Checking of all electrical connections for their proper tightness including charging alternators and battery clamps. v)Engine Panel / PCC, Alternator will be covered in AMC. vi)Replacement of all filters, refilling of engine oils, checking of all nuts and bolts tightness, correction of engine alternator alignment in case defect and replacement of rubber insert/block if broken to be carried out vii)Service engineer shall carry out "B" checks on the engine, as per the check list and would correct / recommend / suggest improvement in operation and performance.
6312.5/15 KVA
6420 KVA
6525 KVA
6630 KVA
6750 KVA
6882.5KVA
69125 KVA
70320 /380 KVA
71Attending any fault ( Start /Stop) or other defects on emergency basis of technecian for the entire period of contract on DG set of any Capacity and AMF Panel or other control panel all as directed Service engineers to visit the site once in a month totaling to Ten visits per year. The schedule of visits can be mutually decided,if in normal condition by Engineer in Charge.
72Supply and fixing the following spares in replacement/ fixing at site for DG sets/ AMF panels complete all as specified and directed.
73Air Filter Primary for Generator 25 KVA - 62.5 KVA
74Lube Oil filter for Generator 25 KVA - 62.5 KVA
75Fuel Filter filter for Generator 25 KVA - 62.5 KVA
76Air Filter Primary 75 KVA - 82.5 KVA
77Air Filter Safety Inner75 KVA - 82.5 KVA
78Fuel Water Separator 75 KVA - 82.5 KVA
79Oil Filter 75 KVA - 82.5 KVA
80Fuel Filter 75 KVA - 82.5 KVA
81Air Filter Primary 100 KVA – 125 KVA
82Air Filter Safety Inner100 KVA – 125 KVA
83Fuel Water Separator 100 KVA – 125 KVA
84Oil Filter 100 KVA – 125 KVA
85Fuel Filter 100 KVA – 125 KVA
86Air Filter Primary225 - 320 KVA
87Air Filter Safety Inner225 - 320 KVA
88Fuel Water Separator 225 - 320 KVA
89Oil Filter225 - 320 KVA
90Fuel Filter 225 - 320 KVA
91Super By Pass Filter320 KVA
92½ Ltr Lube Oil Filter320 KVA
93Fuel pipe wire braded 1,1/4"" to 3/8"" PVC best quality as per existing make( FEED PUMP TO FUEL FILTER )
94Oil pressure gauge complete.
95Oil pressure Switch complete.
96Water temperature gauge
97Ignition switch
98Indicating lamp
99Battery terminal heavy duty of brass.
100Distilled water.
101coolant for radiator. Sealed bottle
102Engine oil premium blue 20W 40
103Fan belt. Make Fenner/Dunlock
104Self starter 12 volts
105Self starter 24 volts
106Gasket Set
107Turbo charger assembly up to 50 KVA Dg set
108Fuel Injector pumpup to 30 KVA
109AVR 82.5 KVA
110AVR up to 50KVA
111Battery lead 1.5 meter long 16 sq mm copper conductor
112Solenoid Valve
113Engine Couplingfor DG set 30 KVA to 82.5 KVA
114Battary 12 Volt 100 AH
115Battary 12 Volt 150 AH
116Battary 12 Volt 180 AH
117Taking down and re fixing including Calibration and cleaning of the PT pump with replacement of shaft fuel pump drive, hub coupling, gasket set and governor barrel & plunger etc.of 50 to 125 KVA
118Taking down and re fixing including Calibration of the injector assembly with replacement of kit injector’s adjustment up to 50 KVA
119Servicing ofAMF panel with neecessary testing including replacement ofunserviceable partsall as specified and directed by engineer in charge all as per manufacturer/authorised service centre for the following:- Note.Rate quoted shall be included attending any fault ( Start /Stop) or other defects on emergency basis of technecian for the entire period of contract .No extra cost will be paid to the contractor for the same.
120Supply and fixing the following spares in replacement/ fixing at site for AMF panels complete all as specified and directed.
121Supply failure timer
122Restoration timer
123Auxillary contactor 3 phases suitable for AMF panel .
124NO / NC Contact - 240V A.C.,3 A..
125Under Voltage Relay
126Time delay Relay
127Contractor 4 pole 250 Amps for 125 KVA DG set
128Contactor 3 pole MNX 80
129Battary Charger AMF Panel12/24 volt .
130Controller for 82.5 KVA to 200 KVA
131Controllerup to 63 KVA
132AVR 3 phases for 82.5 KVA to 125 KVA
133Contactor Relay for 82.5 KVA to 200 KVA
134Contactor Relay for 10KVA to 50KVA
135Repair of canopy with locks - Keys
136HRC Fuse holders & Fuse bases range 63-160 amp suitable for Cylindrical / DIN fuse-links
137HRC Fuse holders & Fuse bases range 80-250 amp suitable for Cylindrical / DIN fuse-links
138HRC Fuse holders & Fuse bases range 200-800amp suitable for Cylindrical / DIN fuse-links
139DIN type fuse links up to 160 amps
140DIN type fuse links 200 to 400amps
141Acrylic sheet suitable for DG set Canopy matching with existing size and thickness
142M&L cleaning and descaling of radiator assembly by using suitable chemical (MAC solution) and by blower fan and by injecting water in high pressure in water tubings so as to remove all dirts etc in the fins complete all as specified and directed for DG set of following capacity:-
143320 KVA
144125 KVA
14582.5 KVA
146Up to 50 KVA
147M & L for Preparation of existing surface of D.G. Set at various locations capacity 12.5 KVA to 50KVA by scraping out the old existing peeled off paint layer, filling the cavities with suitable filler, making the surface smooth and applying two coats of synthetic enameled paint by spray machine including writing necessary details of D.G. Set i.e. SM No. & MES No. in the pattern and style with using synthetic enameled white paint complete all as specified and directed.
148M & L forPreparation of existing surface of D.G. Set at various locations capacity 82.5 KVA to 320KVA by scraping out the old existing peeled off paint layer, filling the cavities with suitable filler, making the surface smooth and applying two coats of synthetic enameled paint by spray machine including writing necessary details of D.G. Set i.e. SM No. & MES No. in the pattern and style with using synthetic enameled white paint complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail