Special Repairs To Bldg No P-01 ( 08 Qtrs ) Jcos Md Accn At Idsr At Dipatoli Pocket And Special Repairs To Sewage Lines And Septic Tank Of Bldg No T-3 / 1 , T-3 / 2 And T-3 / 3 Or Md Accn Of Inf Div Sig Regt At Dipatoli Mil Stn U, Dipatoli-Jharkhand

Military Engineer Services-MES has published Special Repairs To Bldg No P-01 ( 08 Qtrs ) Jcos Md Accn At Idsr At Dipatoli Pocket And Special Repairs To Sewage Lines And Septic Tank Of Bldg No T-3 / 1 , T-3 / 2 And T-3 / 3 Or Md Accn Of Inf Div Sig Regt At Dipatoli Mil Stn U. Submission Date for this Tender is 28-10-2021. Building Repair Tenders in Dipatoli Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

29515229
Special Repairs To Bldg No P-01 ( 08 Qtrs ) Jcos Md Accn At Idsr At Dipatoli Pocket And Special Repairs To Sewage Lines And Septic Tank Of Bldg No T-3 / 1 , T-3 / 2 And T-3 / 3 Or Md Accn Of Inf Div Sig Regt At Dipatoli Mil Stn U
Open Tender
Indian
Jharkhand
Dipatoli
28-10-2021

Tender Details

Special Repairs To Bldg No P-01 ( 08 Qtrs ) Jcos Md Accn At Idsr At Dipatoli Pocket And Special Repairs To Sewage Lines And Septic Tank Of Bldg No T-3 / 1 , T-3 / 2 And T-3 / 3 Or Md Accn Of Inf Div Sig Regt At Dipatoli Mil Stn Under Ge Dipatoli Special Repairs To Bldg No P-01 ( 08 Qtrs ) Jcos Md Accn At Idsr At Dipatoli Pocket And Special Repairs To Sewage Lines And Septic Tank Of Bldg No T-3 / 1 , T-3 / 2 And T-3 / 3 Or Md Accn Of Inf Div Sig Regt At Dipatoli Mil Stn Under Ge Dipatoli

Key Value

Document Fees
INR 500 /-
EMD
INR 67960.0 /-
Tender Value
INR 33.98 Lakhs /-

BOQ Items

Name of Work:- SPL REPAIRS TO BLDG NO P-01(8 QTRS) JCOs MD ACCN AT 23 IDSR AND SPL REPAIRS OF SEWAGE LINE AND SEPTIC TANK OF BLDG NO T-3/1, T-3/2 AND T-3/3 OR MD ACCN OF INF DIV SIG REGT AT DIPATOLI MIL STN.
Sl. No. Item Description
1Demolition of cement concrete in ground floors and paving n.exc 15cm thickness(below or above ground level) all as specified and directed.
2Demolition of RCC in floors (other than ground floors beams,chajjas,lending slab and similar suspended works all as specified and directed.
3M&L Chequered cement conc tiles 20cmx20cmx25mm thick set over 15mm thick screed bed in CM (1:6), set and joined and pointed in neat cement slurry with coloured cement and no pigment, complete all as specified and directed at site.
4M&L PCC 1:3:6 Type C2 (40mm graded aggt) 75mm thick without using extra cement as in plinth protection/footpath, complete all as specified and directed at site.
5Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed at site.
6Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed at site.
7Brushing neat cement slurry with 3.00 Kg of cement per sqm complete all as specified and as directed by Engr-in-Charge.
8M&L Machine cut cuddapa stone slab 20 -25mm thick over 15mm thick CM (1:6) cement screedbase laid and jointed with greyement slurrymixed with pigment to match the shade of slab including rubbing and polishing complete.
9Rounding to edges of stone slabs on edge such as in steps cooking platform and other similar situations, complete all as specified and directed at site.
10M&LNon- skid colour ceramic tiles,7 to 8mm thick square / rectangular area of each tile exc 0.11 sqm but n exc 0.18sqm in floor over and including 15mm thick screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and directed.
11M&LNon- skid colour ceramic tiles,7 to 8mm thick square / rectangular area of each tile exc 0.11 sqm but n exc 0.18sqm in skirting including 10mm thick screed bed in CM(1:4) complete all as specified and as directed by Engr-in-Charge.
12M & L joint free Non Skid ceramic colour ceramic tiles,7 to 8mm thick square/rectangular area of each tile 0.06sqm but not exceeding 0.11sqm ,in floors over and including 15mm thick screed bed in CM(1:6),set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfacecoloured cement to match the floor complete all as specified and as directed by Engr-in-Charge.
13M&Lfor coloured glazed ceramic tiles in vertical surface 350mmx250mmx7mm thick over and including10 mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces complete all as specified and directed.
14Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed by Engr-in-Charge.
15M&L rendering 15 mm thick in cement mortar 1:4on wall of brick work or concretesurface, finished fair and smooth all as specified and directed.
16M&L rendering 15 mm thick in cement mortar 1:6on wall of brick work or concretesurface, finished fair and smooth all as specified and directed.
17M&L rendering 5 mm thick in cement mortar 1:3on ceilingof brick or concretesurface, finished fair and even all as specified and directed.
18Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar complete all as specified and as directed by Engr-in-Charge.
19M &L Brickwork with sub-class "B" old size bricks, straright or corved on plan exc 6m mean radius built in Cement mortar 1:6complete all as specified and directed.
20Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sq. m each,complete all as specified and directed.
21Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 & n exc 4 sq. m each,complete all as specified and directed.
22Taking downshutters of any descriptionexc 1 but n exc 2 sq. m each,complete all as specified and directed.
23S&F pressed steel frames for doors of size 125x60 mmwith one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed.
24M&L Glazed and skeleton shutters 35 mm thickopen rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20 (a); for doors supplied and fitted to chowkats complete all as specified and directed.
25S&F Plain framed, panelled shutter (two panel) factory made 35 mm thickof 2nd class HW rail and stylewith lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), Kiln seasoned and chemically pressure treated,. complete all as specified and directed.
26S&F 2nd class hardwood,plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints,complete all as specified and directed.
27M&L Prelaminated particle board 18/19 mm thick interior grade , prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to timber frame work framed work as in cupboard.incl. leaping all around.
28S&F Hasp & staple ,75mm, Aluminium anodised incl bolt to hinge plate and fixed with screws for cupboard, complete all as specified and as directed by Engr-in-Charge.
29S&F Continious (piano) hinges, mild steel, bright finish or elecrogalvenised, 30 mm width of flaps(when open), complete all as specified and as directed by Engr-in-Charge.
30S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
31S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame as per specification & drawingcomplete all as specified and directed.
32S&F Powder coated aluminium frame for windows with one or more rebates including joining cleat for fixing etc. complete all as specified.
33S&F Powder coated aluminium windowand ventilator shutters, side hung type without sash bars, aluminium sections weeighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fitings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
34S&F Sheet glass,4.mm ordinary quality and glazing within square n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engr-in-Charge.
35S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average with of aperture 1.18mm and fixed withtinned tack, or galvanised wire staples
36S&F mild steel works as in small articles like hold fasts, conforming to Fe-290 or Fe E-165 all as specified & directed.
37S&F Aluminium anodised barrel tower bolt 150mm long, complete all as specified and as directed by Engr-in-Charge.
38S&F Aluminium alloy, anodised sliding door bolt of size 250mm with hasp and staple and fixing clips of sheet, complete all as specified and as directed by Engr-in-Charge.
39S&F Aluminium alloy,anodised handle cast type of size 125mm, complete all as specified and as directed by Engr-in-Charge.
40S&F SS Butt hinges medium weight 100mm size,cold rolled mild steel, complete all as specified and as directed by Engr-in-Charge.
41S&F Ordinary rat tail rod pattern, 300mm spring incl roller and roller plate complete, complete all as specified and as directed by Engr-in-Charge.
42S&F Floor door stoper 150mm of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed by Engr-in-Charge.
43S&F in repair harrison rails,mild steel, chromium plated with fixing brackets, stops, rollers etc, complete all as specified and as directed by Engr-in-Charge.
44Taking down GI tubing and connection including removing to store of 15mm dia complete aall as secified and directed
45Taking down GI tubing and connection including removing to store of 20mm dia complete aall as secified and directed
46Supplied and fixed GI tubing 15 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified and directed
47Refixing15mm boretubes, any grade, to walls and ceilings or laying in floors, complete all as specified and as directed by Engr-in-Charge.
48Supplied and fixed GI tubing 20 mm bore medium grade with all fittings fixed to walls and ceilings or laid in floors all as specified and directed
49Refixing20mm boretubes, any grade, to walls and ceilings or laying in floors, complete all as specified and as directed by Engr-in-Charge.
50Straight fair cutting n.exc 10cm width or girth on exposed surface of brick work including rubbed finish and waste, complete all as specified and directed at site.
51S&F in repair Bib taps ,15 mm bore,chromium plated with crutch or butterflyhandle, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed at site.
52S&F in repair Gun-metal, globe or gate valves 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed at site.
53S&F in repair15mm dia stop valvefancy type chromium plated concealed type, screwed down high pressur, with crutch or butterfly handle, screwed both hands for iron pipe or for unions, complete all as specified and directed at site.
54S&F looking mirror 600x450 mm, bevelled edge of selected quality glass mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed at site.
55S&F Chromium plated tubular towel rail, 20mm dia, D type 60 cm long between flanges, complete all as specified and directed at site.
56Supplied and fixed in repair 125 mm size brass chormium plated shower rose including fixing to steel pipe or union complete all as specified and directed at site.
57Supply and fixing in repair PVC low level flushing cistern of 10 Ltr capacityincluding flushing pipe bend,PVC connection etc. complete all as specified and directed.
58Supply and fixing in repairvitreous china squatting pan "Orrisa pattern" size 580x440mmwhitewith integral foot rests any pattern including provn of lime concrete bedding and making connection with & including PVC P Trap, etccomplete all as specified and directed.
59Taking down eaves gutters and rain water pipes (any ize or patterns)including all heads,shoes,bends,swan-necks etc, complete all as specified and directed at site.
60S&F PVC(SWR) floor trap 75mm dia plain with grating incl jointing with solvent cement, complete all as specified and directed at site.
61S&F PVC(SWR)pipe 110 mm dia single socketed in any length with rubber ring joints, fixed to wall with and including stack and clamp, complete all as specified and directed at site.
62M&L PVC (SWR) bend of radius 110mm dia, complete all as specified and directed at site.
63M&L PVC(SWR) Tee of radius 110mm dia, complete all as specified and directed at site.
64M&L PVC(SWR) pipes 75mm dia single socketed, in any length with rubber ring joints,laid in trenches or fixed to wall with and including stack and clamp, complete all as specified and directed at site.
65M&L PVC (SWR) bend of radius 75mm dia complete all as specified and directed at site.
66M&L PVC (SWR) Tee of radius 75mm dia , complete all as specified and directed at site.
67Demolition of cement concrete in ground floors and paving exc 15cm thickness(below or above ground level) all as specified and directed.
68M&L Cement concrete 1:5:10 type E-2 (using 40 mm graded aggregate as in filling around shunken areas complete all as specified and directed.
69M&L for 40 mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate with WPC as in sunken portion and making adequate slope toward spout pipe complete all as specified and as directed. NOTE: - Water Proofing Compound shall be measured and paid separately
70M&L for rendering 15 mm thick on concrete orbrick surface in CM (1:3) mixed with WPC as per manufacturer instructions and finishes surfaces even and smooth with out using extra cement. Note - WPC will be measured and paid separtely
71M&L for applying two coats evenly a tack coat of hot air blown bitumen of grade 85/25 @ 1.50 Kg per sqm per coat (one coat overplaster and one coat on polythene film) including cleaning of surface over polythene film complete all as specified and directed at site.
72M&L for polythene film black 200 micron thick laid in floor, vertical surface etc complete all as specified and directed.
73M&L Cement concret(1:3:6) TypeC-2 using 40mm graded stone aggregate as in surface channel and drain, complete all as specified and directed at site.
74M&L Extra for forming fair finished drain or channel 30cm inner girth in cement concrete,using extra cement,including forms,mitred/stopped ends etc.
75M&L precast cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in man hole cover slabs, shelves, and similar work set in CM (1:4).complete all as specified and directed.
76M&L Mild steel(TMT) bar,10 mm dia and over in Reinforcement cut to length bent to shape required including cranking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete.
77M&L TMT bars 6 to 8mm dia, cut to length bent to shape required including cranking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete.
78Roof treatment for non approachable roof including complete removal of existing roof treatment :- (i) Rendering 10mm thick in cement mortor (1:3) mixed with liquid water proofing compound finished the surface fair and even.(ii) Applying evenly a coat of bitumen primer @ 0.30 Kg/Sqm. (iii)Applying APP modified polymeric membrane over the bitumen coat surface ,weight not less than 3.20-3.50 Kg/Sqm and over lap 100mm and sealed by torch application as per manufacture insteructions.(iv) Applying a coat of aluminium paint @ 200 gm/sqm in two coats over polymeric membrene.
79Roof treatment for approachable roof including complete removal of existing roof treatment :- (i) Rendering 10mm thick in cement mortor (1:3) mixed with liquid water proofing compound finished the surface fair and even.(ii) Applying evenly a coat of bitumen primer @ 0.30 Kg/Sqm. (iii)Applying APP modified polymeric membrane over the bitumen coat surface ,weight not less than 3.2-3.5 Kg/Sqm and over lap 100mm and sealed by torch application as per manufacture insteructions.(iv) Acoatofhotblownbitumen@1.2Kg/Sqmshallbeappliedoverpolymeric membrane and blinded with clean dry sand at the rate of 0.5 Kg per Sqm.
80M&L 22mmthick machinepressed &polished‘cementconcretetileswithgreycementwithoutpigmentofsize 250 mm x 250 mm laid in neat cement slurry over and including 15 mm thick bed screed in CM 1:4 mixed with chemical compound PIDIPROOF LW of DR FIXIT of PIDILITEINDUSTRIESLTD 200 milli - litremixed with 50 Kg of cement or STP No 1 (LIQUID) of STP LTD in proportion 200 milli litre per 50 Kg cement,aspermanufacturesinstructionsandtilesproperlylaidwith3mmwidejoints filledwithFEVIMATETGofDRFIXITofPIDILITEINDUSTRIESLTDor TILEGLUEofSTPLTDaspermanufacturesinstructions complete all as specified and directed by Engr- in - charge.
81Supply only liquid water proofing compound.
82Excavation in trenches n exc 1.5 m widen exc 1.5 m deep in soft/ loose soil for foundation etcor for shaft, wells, manholes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out. complete all as specified and directed.
83Demolition and breaking up 200 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar
84S&F 200mm dia Salt-glazed stone ware drain pipes laid in trenches and jointed as specified
85M&L Cement concrete bed to drain pipes including packing under ,hounching against the side of pipes after they are laid and tested in PCC(1:3:6) type C-2 for200mm dia pipe
86M&L for preparingthe new plastered surfacesof walland applying Twocoat of cement based paint after one coat of white primerall as specified .
87M&L for preparingthe old surfaces by complete removel of existingtreatmentand applying twocoats of cement bsed paint on walls complete all as specified .
88M&L for preparing new plastered surfaces and applying two coats of distember oil emulsion white or tinted after one coat of white primer complete all as specified and directed.
89M&L for preparing of old surfaces by complete removel of existing treatmentand applying two coats of distember oil emulsion on wall complete all as specified and directed.
90M&Lforpreparation of new surfaces and applying Three coat of white wash on wall including cornices etc complete all as specified and directed by Engr-in-Charge.
91M&Lforpreparation of new surfaces and applying three coat of white wash on ceiling including cornices etc complete all as specified and directed by Engr-in-Charge.
92M&Lforpreparation of old surfaces and applying one coat of white wash on wall including cornices etc complete all as specified and directed by Engr-in-Charge.
93M&Lforpreparation of new surfaces and applying Three coat of white wash on ceiling including cornices etc complete all as specified and directed by Engr-in-Charge.
94M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified.
95M&L for applying two coats of synthetic enameled painton old paintedwoodensurfaces of any description not otherwise described over 10cm width or girth including preparation of surface all as specified and directed.
96M&L forrepair and rendering 10mm thickin cm 1 :3on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete includingcleaning of viisible reinforcementandtreating with cement slurry also necessary repair to cracked concreteif any with cement concrete1:2:4 Type B-0 using 12.5mm gradedaggregateincluding necessary scafolding work for double/single storey bldgs all as directed .
97Excavation over areas n exc 1.5 m deep in soft/ loose soil and getting out complete all as specified and directed.
98Excavation over areasexc 1.5 m and n exc 3.00 mdeep in soft/ loose soil and getting out complete all as specified and directed.
99Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point, complete all as specified and directed.
100Returning filling in including spreading leveling watering and well ramming in layers n.exc.25 cm complete all as specified and directed.
101M&L Cement concret(1:4:8) Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete, complete all as specified and directed.
102Use and waist form work to soffits of suspended slabs such as roof slabs, floor slabs n.exc.200mm thick complete all as specified and directed.
103Demolition ofcement concrete(reinforced) in roofs,floors(otherthan ground floors), beams, staircases, landing, chajjas and similar suspended wor etc complete all as specified and as directed by Engr-in-Charge.
104M&L reinforced cement concrete 1:2:4 type B 1 (using 20 mm graded aggregate) as in slabs supported on walls, beams and columnsin floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
105M & L Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in in Cement mortar 1:6complete all as specified and directed.
106M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
107M&L for setting coatof 3mm thick,trowelled to even and smooth finish by cement plastar 1:2 complete all as specified and directed.
108M&L loose filling with aggreagate of broken bricks , gauge n.exc 80mm to 150 mm in soakage pit/ sokage wells complete all as specified and directed.
109Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and directed.
110S&F reinforced concrete 200mm pipes, class NP2laid and jointed complete with collars complete all as specified and directed.
111S&F reinforced concrete 150mm pipes, class NP2laid and jointed complete with collars complete all as specified and directed.
112M&L Cement concrete bed to drain pipes including packing under ,hounching against the side of pipes after they are laid and tested in PCC (1:4:8) type D-2 for200mm dia pipe
113M&L Cement concrete bed to drain pipes including packing under ,hounching against the side of pipes after they are laid and tested in PCC (1:4:8) type D-2 for150mm dia pipe
114Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. etc complete all as specified and directed.
115Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good thedisturbed surfaces of walls,floors roofs etc complete all as specified and directed.
116Taking down old/unserviceableDB SPN any capacity by disconnection of electric connectionincludingMCBs,Isolators,etc and making good to disturbed surface complete all as specified and directed.
117Taking down old/unserviceableMCB SPN/DP any capacity by disconnection of electric connectionincludingMCBs,Isolators,etc and making good to disturbed surface complete all as specified and directed.
118Taking down Old/ Unserviceabl MCBDBs TPN / Main Switchesby disconnection of electric connection including old unsvMCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specifiedand directed.
119M&L point wiringfor One light/Fan point controlled by onefive amps one way single pole switch complete with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn throughPVC concealed conduit 20/25 mm dia on wall/ceiling ,including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes ,cromium plate screwas suitablesize for mounting ofswitch & scoketincluding 1.5 sqmm size pvc insulated unsheathed copperconductor to common earth and connecting to earth dolly complete all as specified and directed. Note: Therate quoted is deemed to be included for Penolic sheet (Hylem) and steel terminal box , cutting of hylem sheet for fixing ofswitch and scoket including cutting chases in wallmaking good to disturbed surface and matching with existing surfaces.
120All as per Ser item No 119 here-in-before but one 3 Pin Socket out let 5 Amps on the same board, complete all as specified and directed.
121All as per Ser item No119 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board, complete all as specified and directed.
122All as per Ser item No 119 here-in-before but one bell/buzzer point controlled by onepush button on the independent board, complete all as specified and directed.
123All as per Ser item No 5 here-in-before butpoint wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly.
124S&FSwitch Piano type2 way switch 5 amp230 vcomplete all as specified and directed at Site. Make : Polycab/Havells/Anchor
125Supply and fixSwitch Piano type, single pole, one way 5 Amp complete all as specified & directed.Make :- Havells /HPL/Anchor
126S&F Switch pianotype , singlepole , one way15 Amps complete all as specified and directed. Make :- Polycab/Havells/Anchor
127S&FSocket out let2-in-1 2/3 pin 5 Ampscomplete all as specified and directed .Make :- Polycab/Havells/Anchor
128S&F Socket outlet 2-in-1, 3 pin ,5 and 15 amps , flush type complete all as specified & directed.Make :- Polycab/Havells/Anchor
129S&F in replacement electric Bell, ding dong type AC 230 Volt single pole complete all as specified & directed at site.Make :- Polycab/Havells/Anchor
130S&Fin replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole complete all as specified & directed.Make :-Polycab/Havells/Anchor
131S&FCeiling rose,3 terminal PVC/polycarbonatecomplete all as specified and directed.Make : Polycab/Havells/Anchor
132S&Felectronic regulator step type230 Volts single phase120 wattcomplete all as specified and directed at site.Make:- Polycab/Havells/Anchor
133M&L for lamp holder , PVC /Polycarbonate type with back plate suitabl for batten fittings complete all as specified and directed at site.Make : Polycab/Havells/Anchor
134M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor , PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm diaas per site requirement along walls/ceilingetc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surfaceconduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor)be measured as one length)
135All as per ser item No-134 here-in-beforebut 2X2.5 Sqmm and 1X 2.5 Sqmm for Earth wire, complete all as specified and directed.
136All as per ser item No-134 here-in-beforebut 2X4 Sqmm and 1X 4.0 Sqmm for Earth wire complete all as specified and directed.
137All as per ser item No-134 here-in-beforebut 2X 6 Sqmm and 1X 6.0 Sqmm for Earth wire complete all as specified and directed.
138Supply and fix MCBDB SPN 8 way double doorwith metal door suitabl forhousing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directedcompleteall as specified and directed at site. Make -Legrand /Havells/HPL/Schneider
139Supply and fix MCBDB TPN 4 way with metal door suitable forProvision ofincommer MCCB-100Aand out going MCBsgrouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. Make -Havells Part No.DHDLVDRWGOFO04 /Schenider /Legrand.
140Supply and fix in replacement MCCB 3Pole 415 volts 100 Amps 50 Hz Adjustable type, with breaking capacity 10 KA complete all as specified and directed at site. Make : legrand/Havells/L&T.
141S&F in replacement ofMCB SP 6 to 32 Amps "C" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. Make Havells /Schenider /Legrand.
142S&F in replacement of MCB DP 40Amps "C" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles.Make -Havells /Schenider/Legrand .
143S&F in replacement of MCB DP63 Amps "C" Series 10 KAfixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. Make -Havells/ Schenider /Legrand .
144S&F in replacement of LEDtube light fitting 18/20watt 230 Volt decorative ultra slim linear LED Lighting withaluminium housing & integrated electronic driver , including all internally pre-wired and inncluding connecting upwith twin core twisted flexible copper conductor cable with suitable sizecomplete all as specified and directed at site. Make : - Cat/part No. LUMILINEPLUSBS18WLED865SPCSS of Havells or equivalent in Philips/LUKAR/C&S
145S&F in replacement of building LED security light fitting 35 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device.luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site.Make : Havells CatNo:-ENDURACITYLITEPLATPLUSSL35WLED 757SASYBOPCor equivalent in Philips/C&S
146M&L forrepair rewinding/greshing of ceiling fan of any size sweep single phase.Celing fan of any size opening from any hight or any locations, fan opening from hook,clamp,& refixing the same after rewinding,and greshingwithrequird necessary rewinding,/welding/granding/bushing job etc or required store such as nuts,bolts,,washer and suitable length mild steel/ down rod duly making holes etc complete as perspecified and directed by Engr -in -Charge.
147S&F in replacement Metal body ventilating airfan single phase250 mm sweepcomplete with louver shutter. Quoted rate has been inclusive of all labour charges for making of hole in existing building forfixing of exhaust fan, as per suitablesizefan base after cutting of brick/stone wall /suitable size as required, complete all as specified and directed. Make : Havells model ventil Air - DB or equivalent as per list of makes.
148Supply, Laying on replacement ,connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with alu conductorcable all as directed.
149Supply and Spread dry river sand for cable cushioning in trenches all as specified and directed.Note : Punned down thickness shall be considered for measurement .
150Supply and lay burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection all as specified and as directed at site.
151M &L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr in Charge.Note :- i) Earthing test must be carried out in presence of Engr-in-Charge. ii) The earthing resultnot more than 2 Ohms or disered earth resistance value. iii) Meggerrequired for testingwill bebe provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of bill.
152S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998
Disclaimer :