| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 2 | Excavating holes more than 0.10 cum & upto 0.5 cum including gettingout the excavated soil, then returning the soil as required in layers notexceeding 20cm in depth, including consolidating each deposited layerby ramming, watering etc, disposing of surplus excavated soil, asdirected within a lead of 50 m and lift upto 1.5 m.All kinds of soil |
| 3 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area2.5 sq.meters and under, including cutting the patch in proper shape,raking out joints and preparing and plastering the surface of the wallscomplete, including disposal of rubbish to the dumping ground, allcomplete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand) |
| 4 | Dismantling cement asbestos or other hard board ceiling or partitionwalls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 5 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet |
| 6 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm |
| 7 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 8 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plainG.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts andwashers etc., including making necessary connections with rainwater pipes complete.0.63 mm thick with zinc coating not less than 275 gm/m² |
| 9 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 10 | Providing and fixing plain Multipurpose Cement board ( High Pressure steam cured ) as per IS : 14862, with suitable screws for fibre cement board in ceiling etc. complete (frame work to be paid separately) : 6 mm thick cement board |
| 11 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : Old work (one or more coats) |
| 12 | Finishing walls with Acrylic Smooth exterior paint of required shade: Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 13 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two or more coats) including a coat of approvedsteel primer but excluding a coat of mordant solution |
| 14 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 15 | Providing and fixing uplasticised PVC connection pipe with brassunions :45 cm length 15 mm nominal bore |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters.30 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 17 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominalsize) over 75mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, includingnecessary excavation, levelling & dressing & finishing the top smooth. |
| 18 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 19 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :18.49.1 15 mm nominal bore |
| 20 | Providing and fixing P.V.C. low level flushing cistern with manuallycontrolled device (handle lever) conforming to IS : 7231, with all fittingsand fixtures complete. 10 litre capacity - White |
| 21 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of oldWC seat and “S” or “P” trap at site complete with all operationsincluding all necessary materials, labour and disposal of dismantledmaterial i/c malba, all complete as per the direction of Engineer-incharge.Orissa pattern W.C Pan of size 580x440 mm |
| 22 | Providing and fixing C.P. brass hand spray (Health faucet) with 1 mtr long flexible tube in chrome finish of approved quality make Jaquor or equivalent. |
| 23 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, blackfinished reinforced with glass fibre matt consisting of a coat of bitumenprimer for bitumen membrane @ 0.40 litre/sqm by the samemembrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre andviscocity 70 - 160 cps. Over the primer coat the layer of membraneshall be laid using butane torch and sealing all joints etc., andpreparing the surface complete. The vital physical and chemicalparameters of the membrane shall be as under : Joint strength inlongitudinal and transverse direction at 23°C as 350/300 N/5 cm.Tear strength in longitudinal and transverse direction as 60/80N.Softening point of membrane not less than 150°C. Cold flexibilityshall be upto -2°C when tested in accordance with ASTM, D - 5147.The laying of membrane shall be got done through the authorisedapplicator of the manufacturer of membrane :3 mm thick |
| 24 | Structural steel work riveted, bolted or welded in built up sections, trussesand framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete. |
| 25 | 12 mm cement plaster finished with a floating coat of neat cement of mix ::1:4 (1 cement: 4 fine sand) |
| 26 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), Jointing with greycement slurry @ 3.3 kg/sqm includingpointing the joints with white cement and matching pigment etc.,complete. |
| 27 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stoneaggregate 40 mm nominal size) |
| 28 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 29 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 30 | Add Cost Index @ 30.51 % over DSR 2018 |