| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-10-2021 | 1st Corrigendum | Other | 01-11-2021 |
| Sl. No. | Item Description |
| 1 | BUILDING WORKS ------------------------- Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 2 | Depth of excavation not exceeding 1,500 mm. |
| 3 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 4 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips(20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. |
| 5 | Using Pakur Variety Stone Materials. |
| 6 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any as per relevant IS codes. |
| 7 | Using Pakur Variety Stone Materials. |
| 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation and upto roof of ground floor/upto 4 m |
| 9 | Tor steel/Mild SteelUsing reinforcement steel of SAIL/ TATA/RINL |
| 10 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) |
| 11 | Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete worke. |
| 12 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr\"s hardness > 5.0, Staining resistance:Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). |
| 13 | Sizes-600 mm x600mm x10 mm with breaking strength >1500 N |
| 14 | In Ground Floor |
| 15 | In 1st Floor |
| 16 | In 2nd Floor |
| 17 | In 3rd Floor |
| 18 | In 4th Floor |
| 19 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tilesncluding roughening of concrete surface, ifecessary or by synthetic adhesive & grout materials etc. |
| 20 | In floorArea of each tile above 0.09 Sq.mColoured decorative |
| 21 | In Ground Floor |
| 22 | In 1st Floor |
| 23 | In 2nd Floor |
| 24 | In 3rd Floor |
| 25 | In 4th Floor |
| 26 | On WallArea of each tile above 0.09 Sq.mColoured decorative |
| 27 | In Ground Floor |
| 28 | In 1st Floor |
| 29 | In 2nd Floor |
| 30 | In 3rd Floor |
| 31 | In 4th Floor |
| 32 | Supplying, fitting & fixing granite slabs 15mm to 18 mm.thick in floor,lobby,stair,landing & Treads etc. over 20 mm[avg] thick base of cement mortar (1:2)laid with white cement slurry @ 4.40 kg per Square meter before placing of granite & jointed with white cement Slurry @2.0 kg per square meter with necessary pigments and complete as per direction of the Engineer-in-charge including cost of all materials, labours,curing and roughening of concrete surface complete. |
| 33 | Area of each granite Slab above 1.00 Square meter |
| 34 | In Ground Floor |
| 35 | In 1st Floor |
| 36 | In 2nd Floor |
| 37 | In 3rd Floor |
| 38 | In 4th Floor |
| 39 | Supplying, fitting & fixing granite slabs 15mm to 18 mm.thick with uniform texture & without decorative veins incolumns, wall, facia etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete.[Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] |
| 40 | Area of each granite Slab above 1.00 Square meter |
| 41 | In Ground Floor |
| 42 | In 1st Floor |
| 43 | In 2nd Floor |
| 44 | In 3rd Floor |
| 45 | In 4th Floor |
| 46 | Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor,lobby,stair , landing & treads etc. over 20 mm (av.)thck base of Cement mortar (1:2) laid with white cement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as per direction of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency] |
| 47 | With Chawk DungriArea of each tile exceeding 0.6 sq.m but not excedding 1 sq.m. |
| 48 | In Ground Floor |
| 49 | In 1st Floor |
| 50 | In 2nd Floor |
| 51 | In 3rd Floor |
| 52 | In 4th Floor |
| 53 | Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Marble Stone. |
| 54 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. |
| 55 | 35 mm thickIn 5th Floor |
| 56 | Brick work with 1st class bricks in cement mortar (1:6) |
| 57 | In superstructure |
| 58 | In 1st Floor |
| 59 | In 2nd Floor |
| 60 | In 3rd Floor |
| 61 | In 4th Floor |
| 62 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Fifth floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar20 mm thick plaster |
| 63 | In 1st Floor |
| 64 | In 2nd Floor |
| 65 | In 3rd Floor |
| 66 | In 4th Floor |
| 67 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) |
| 68 | Upto 4th floor |
| 69 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor) |
| 70 | One CoatWater based interior grade Acrylic Primer |
| 71 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface. |
| 72 | Two Coats |
| 73 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. |
| 74 | One Coat |
| 75 | In Ground Floor |
| 76 | In 1st Floor |
| 77 | In 2nd Floor |
| 78 | In 3rd Floor |
| 79 | In 4th Floor |
| 80 | In 5th Floor |
| 81 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. |
| 82 | Two CoatsPremium 100% Acrylic Emulsion |
| 83 | In Ground Floor |
| 84 | In 1st Floor |
| 85 | In 2nd Floor |
| 86 | In 3rd Floor |
| 87 | In 4th Floor |
| 88 | In 5th Floor |
| 89 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). |
| 90 | 15 Micron colour annodizing.2- track sliding window |
| 91 | Bottom frame |
| 92 | Top and side frame. |
| 93 | 3- track sliding window |
| 94 | Bottom frame |
| 95 | Top and side frame. |
| 96 | Fixed glazing. |
| 97 | Top, bottom and side member. |
| 98 | Shutter for all track sliding window. |
| 99 | Bottom & Top member. |
| 100 | Style side member. |
| 101 | Interlock member. |
| 102 | Louvered window. |
| 103 | Top, bottom and side member. |
| 104 | Louvered Section. |
| 105 | Cleat angle ( Non-annodized). |
| 106 | Fixed partitions |
| 107 | Top, bottom and side member. |
| 108 | Intermediate member. |
| 109 | Glazing clip. |
| 110 | Labour charge for fabrication and installation of composite door, window , partitions made from annodized extruded alloy aluminium sections for the following units:-Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Poly Shulphate sealant and in between shutter and window frame etc. |
| 111 | 2 track sliding window. |
| 112 | In Ground Floor |
| 113 | In 1st Floor |
| 114 | In 2nd Floor |
| 115 | In 3rd Floor |
| 116 | In 4th Floor |
| 117 | 3 /4 track sliding window. |
| 118 | In Ground Floor |
| 119 | In 1st Floor |
| 120 | In 2nd Floor |
| 121 | In 3rd Floor |
| 122 | In 4th Floor |
| 123 | Louvered window. |
| 124 | In Ground Floor |
| 125 | In 1st Floor |
| 126 | In 2nd Floor |
| 127 | In 3rd Floor |
| 128 | In 4th Floor |
| 129 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. |
| 130 | For sliding windows |
| 131 | T\" shaped EPDM gasket for frames. |
| 132 | U\" shaped EPDM gasket for frames |
| 133 | Supplying PVC rollers for sliding windows as per direction of Engineer in charge. |
| 134 | Supplying maruti lock (100mm) |
| 135 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835- 1987. |
| 136 | 5mm thick coloured / tinted / smoke glass |
| 137 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). |
| 138 | Sal : Siliguri. |
| 139 | In Ground Floor |
| 140 | In 1st Floor |
| 141 | In 2nd Floor |
| 142 | In 3rd Floor |
| 143 | In 4th Floor |
| 144 | In 5th Floor |
| 145 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)40mm X 6mm, 200mm Length |
| 146 | In Ground Floor |
| 147 | Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: |
| 148 | 35mm thick shutters (single leaf) |
| 149 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor |
| 150 | 40mm thick shutters with 19mm thick panel of size 30 to 45 cmSishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. |
| 151 | In 5th Floor |
| 152 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. |
| 153 | 66mm x 90mm |
| 154 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. |
| 155 | 32 mm thick |
| 156 | In Ground Floor |
| 157 | In 1st Floor |
| 158 | In 2nd Floor |
| 159 | In 3rd Floor |
| 160 | In 4th Floor |
| 161 | M.S. works in framed gratings of window etc.made of round or square bars and frame work or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate flat bar stiffener and fixed with necessary screws etc. complete, as directed. |
| 162 | In ground floor. |
| 163 | Locking arrangement for Jail type doors including supplying fitting and fixing in position complete as per approved design. |
| 164 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. |
| 165 | 100mm. X 75mm. X 3.50mm. |
| 166 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: |
| 167 | 225mm long x 12mm dia. bolt. |
| 168 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete. |
| 169 | With continuous plate base (Hexagonal / Round rod) |
| 170 | 100 mm grip x 12 mm dia rod |
| 171 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. |
| 172 | 300mm x 16mm dia bolt. |
| 173 | Supplying \"Godrej\" mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. |
| 174 | Door stopper (Anodised aluminium) |
| 175 | Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complite. |
| 176 | Heavy type (I.S.I. size 3) |
| 177 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 178 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 179 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : |
| 180 | On timber or plastered surface :With super gloss (hi-gloss) -Two coats (with any shade except white) |
| 181 | On steel or other metal surface :With super gloss (hi-gloss) -Two coats (with any shade except white) |
| 182 | Supplying, fitting & fixing circular corrugated Aluminium sheet (excluding the supporting frame work) of approved make & brand in alloy 3105 conforming to IS: 1254-1991 fitted and fixed with 55 mm & 25 mm Self tapping screw ,EPDM Washer 16 mm dia & 3 mm th washer etc complete with 150 mm. end lap and one corrugation minimum side lap. (Payment to be made on area of finished work) (Aluminium sheet to be supplied by contractor). |
| 183 | In Roof:-With 0.91 mm thick sheetIn 5th Floor |
| 184 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. |
| 185 | For structural members of specified sections weighing less than 22.5 Kg./m |
| 186 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). |
| 187 | In Roof:- |
| 188 | With 0.5 mm thick sheet |
| 189 | Supplying, fitting & fixing UPVC pipes AType and fittings conforming to IS:13592- 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc ifecessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. |
| 190 | UPVC Pipes: |
| 191 | 160 mm. Dia. |
| 192 | UPVC Fittings: |
| 193 | Plain Y |
| 194 | 160 mm. Dia. |
| 195 | Bend 87.5 degree |
| 196 | 160 mm. Dia. |
| 197 | Shoe |
| 198 | 160 mm. Dia. |
| 199 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height verticalalustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) |
| 200 | Supplying,fitting & fixing in position suspended false ceiling with frame work of aluminium hollow section of size 50mm X 25mm (2.0mm thickness) combined with aluminium corners of size 38mm X 25mm, suspended by aluminium hollow tube section of size 38mm X 25mm having size of 600mm X 600mm ceiling with aluminium composit panels (ACP) - Interior grade of thickness 3.0mm comprising of proctective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer\"s specification finished with aluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction of Engineer-in-charge. |
| 201 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] |
| 202 | With 1:4 cement mortar20 mm thick plaster |
| 203 | In Ground Floor |
| 204 | In 1st Floor |
| 205 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer\"s specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes. (Payment shall be made on the basis of finished surface area.).Membrane Property: Softening Point > 150 deg C, Cold Flexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N: 300 (longitudinal), 200 (transverse) |
| 206 | Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid in pattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material.(c) Supplying and Laying in the specified pattern of Interlocking Concrete Block Pavements (ICBP) with concrete blocks (with Concrete grade as specified as per Table 1 of IS 15658 : 2006) manufactured from BIS licensee manufacturer, with spacer nib (Small protruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per CI. No 3.26 of IS: 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per CI. No. 3.3 of IS: 15658) as per Table 2 of IS: 15658 with flexural strength/breacking load as per Annexure G of Is: 15658, on th prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with cushion of compacted bedding sand of 25-35 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP-63) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sandwill be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per CI. nO. 8.7 of IRC SP - 63 (2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap.60 mm thick. |
| 207 | Coloured Decorative |
| 208 | SANITARY & PLUMBING WORKS ----- Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats ofainting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) |
| 209 | For Exposed Work |
| 210 | 32 mm dia. medium quality |
| 211 | 40 mm dia. medium quality |
| 212 | 50 mm dia. medium quality |
| 213 | 80 mm dia. medium quality |
| 214 | Supplying, fitting and fixing CPVC (ChlorinatedPolyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. |
| 215 | For Exposed Work |
| 216 | 40 mm dia |
| 217 | 32 mm dia |
| 218 | 25 mm dia |
| 219 | For Concealed Work |
| 220 | 25 mm dia |
| 221 | 25 mm dia |
| 222 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). |
| 223 | 40 mm dia |
| 224 | 25 mm dia |
| 225 | Supplying, fitting and fixing shower ofpproved brand and make. |
| 226 | Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 227 | Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar). |
| 228 | Supplying, fitting and fixing bib cock or stop cock. |
| 229 | Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 230 | Chromium plated Concealed Stop Cock (Equivalent to Code No. 514(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 231 | Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 232 | Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of SSCO or similar brand) |
| 233 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc |
| 234 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer |
| 235 | 2000 litre capacity |
| 236 | Labour for hoisting plastic water storage tank.Above 1500 litre upto 5000 litre capacity.Upto 5th floor. |
| 237 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 238 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. |
| 239 | 550 mm X 400 mm size |
| 240 | Supplying, fitting and fixing pedestal of approved make for wash basin (white) |
| 241 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. |
| 242 | 900 mm long |
| 243 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. |
| 244 | 1050 mm long |
| 245 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 |
| 246 | Single Socketed 3 Meter Length |
| 247 | 110 mm |
| 248 | Bend 87.5º |
| 249 | 110 mm |
| 250 | Plain Tee |
| 251 | 110 mm |
| 252 | Door Tee |
| 253 | 110 mm |
| 254 | Door Bend (T.S.) |
| 255 | 110 mm |
| 256 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. |
| 257 | Above ground |
| 258 | 110 mm dia |
| 259 | Under ground |
| 260 | 110 mm dia |
| 261 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding \"P\" or \"S\" trap (excluding cost of concrete for fixing). |
| 262 | 580 mm X 440 mm |
| 263 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. |
| 264 | With \"S\" trap |
| 265 | With \"P\" trap |
| 266 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. |
| 267 | E.W.C.Plastic (hallow type) white |
| 268 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. |
| 269 | 635 mm X 395 mm X 420 mm |
| 270 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). |
| 271 | 450 mm X 350 mm |
| 272 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. |
| 273 | Polythene Flush Pipe |
| 274 | Supplying, fitting and fixing urinal flush pipe fittings of approved brand. |
| 275 | C.P. urinal flush pipe fittings range of three |
| 276 | Supplying, fitting and fixing porcelain partition wall of approved make of size 618 mm X 310 mm complete in all respect. |
| 277 | Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. |
| 278 | 600 mm X 450 mm |
| 279 | Supplying, fitting and fixing liquid soap container. |
| 280 | Cromium plated. |
| 281 | Supplying, fitting and fixing towel rail with two brackets. |
| 282 | C.P. over brass |
| 283 | 25 mm dia. and 750 mm long |
| 284 | Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets.Plain edge sink with overflow610 mm X 450 mm X 250 mm |
| 285 | Supplying, fitting and fixing pillar cock of approved make. |
| 286 | CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 287 | CP Pillar Cock with 200 mm extended Lever Handle (Equivalent to Code No. 5031 & Model - FLORENTINE of JAQUAR). |
| 288 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. |
| 289 | With Pakur variety stone materials & reinforcement steel of SAIL/TATA/RINL |
| 290 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. |
| 291 | For 50 usersWith Pakur variety stone materials & reinforcement steel of SAIL/TATA/RINL |
| 292 | For 100 usersWith Pakur variety stone materials & reinforcement steel of SAIL/TATA/RINL |
| 293 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.With Pakur variety stone materials & reinforcement steel of SAIL/TATA/RINL |
| 294 | UNDER GROUND WATER RESERVOIR _________________ Earth work in excavation of foundation trenches ordrains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or acking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out waters required complete. |
| 295 | Depth of excavation not exceeding 1,500 mm. |
| 296 | Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
| 297 | Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Paymento be made on the basis of measurement of finished quantity of work) |
| 298 | With earth obtained from excavation offoundation. |
| 299 | Supplying and laying Polythene Sheet (150gm / sq.m.) overdamp proof course or below flooring or roof terracing or in foundation or in foundation trenche. |
| 300 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips(20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. |
| 301 | Using Pakur Variety Stone Materials. |
| 302 | Controlled cement concrete with well graded stone chips (20mm nominal size) excluding shuttering & reinforcement with complete design of concrete as per IS 456 & relevant special publication ,submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of E.I.C.Consumption of cement will not be less than 300kg of cement with super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test & job mix formula.( Using Concrete Mixer) M25 Grade Using Pakur Variety Stone Materials. |
| 303 | In Ground floor- |
| 304 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) |
| 305 | 25 mm to 30 mm shuttering without staging in foundation |
| 306 | In Ground floor- |
| 307 | Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 308 | In Ground floor- |
| 309 | Reinforcement for reinforced concrete work in all sorts of structuresincluding distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation and upto roof of ground floor/ upto 4 m |
| 310 | Tor steel/Mild SteeI. Using reinforcement steel of SAIL/ TATA/RINL |
| 311 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] |
| 312 | With 1:4 cement mortar15 mm thick plaster |
| 313 | In Ground floor- |
| 314 | Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. |
| 315 | Artificial stone in floor, dado, staircase etc with cementconcrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface andpplication of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. |
| 316 | In ground floor. 3 mm. thick topping …….Using grey cement |
| 317 | 35 mm. thickIn Ground floor- |
| 318 | Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer\"s specification for waterproofing layer in water tank etc. (No Departmental Cement is required) |
| 319 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. |
| 320 | UPVC Pipes:110 mm. Dia. |
| 321 | UPVC Fittings: |
| 322 | Bend 87.5 degree110 mm. Dia. |
| 323 | Supplying, fitting and fixing in position C.I. manhole/ pit cover with rim. Round |
| 324 | 450 mm X 100 mm X 75 kg (approx.) |
| 325 | SURFACE DRAIN ________________Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 326 | Depth of excavation not exceeding 1,500 mm. |
| 327 | Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 328 | Do - by fine sand |
| 329 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 330 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. |
| 331 | Using Pakur Variety Stone Materials. |
| 332 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 333 | Using Pakur Variety Stone Materials. |
| 334 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) |
| 335 | 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 336 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation and upto roof of ground floor/upto 4 m |
| 337 | Tor steel/Mild SteelOther than SAIL/ TATA/RINL |
| 338 | Brick work with 1st class bricks in cement mortar (1:6)In superstructure, ground floor |
| 339 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar15 mm thick plaster |
| 340 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. |
| 341 | DEEP TUBEWELL SUBMERSIBLE PUMP Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately). |
| 342 | 150 mm dia. medium quality |
| 343 | 100 mm dia. medium quality |
| 344 | Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia.(upto 50 metre). |
| 345 | First 50 metre |
| 346 | Next 50 metre |
| 347 | Next 50 metre |
| 348 | Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge100 mm nominal dia6.00 mm wall thickness |
| 349 | Supplying M.S. male / female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge.150 mm |
| 350 | Supplying, fitting and fixing heavy type bell mouth reducing socket.100 mm X 200 mm |
| 351 | Supplying, fitting and fixing G.I. cap at top |
| 352 | Providing 200 mm centre guide.With Clamp |
| 353 | Providing and fixing bell plug as required upto 250 mm (internal) dia. ERWMS pipe including cost of materials and labour complete. |
| 354 | Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality. |
| 355 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with \"V\" notch including hire and labour charges for all tools and plants and scaffolding as required. |
| 356 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete. |
| 357 | Supply and delivery of 250 volt single phase 1.5 H.P single phase submersible pump motor set having capasity 2M/Hr,38 metre head & 40 mm dia outlet. |
| 358 | Supply & Fixing of 3 phase 415 volt, 50 Hz. DOL pump Motor Starter with Ammeter, Voltmeter & Indicating lamp having relay range 4.5 to 7.5 A. MUG6 DOL & coil voltage 360 volt. (200 - 400W) (Make LT - LK type) on flat iron frame on wall as to G.S. Cat No.- SS 97756. |
| 359 | ELECTRICAL SUB-STATION BUILDING ---------------------------Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) |
| 360 | Upto area 2.5 Sq.m |
| 361 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 362 | In ground floor including roof.Extra rate for careful dismantling andrecovering at least 150 no of useable bricks per cum. |
| 363 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 364 | In ground floor including roof.upto 150 mm. thick |
| 365 | Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m. |
| 366 | In ground floor including roof. |
| 367 | Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 368 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. |
| 369 | Depth of excavation not exceeding 1,500 mm. |
| 370 | Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 371 | Labour for laying single brick flat soling including ramming and dressing bed to proper level and filling joints with powdered earth. |
| 372 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips(20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. |
| 373 | Using Pakur Variety Stone Materials. |
| 374 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 375 | Using Pakur Variety Stone Materials. |
| 376 | In Ground Floor |
| 377 | In 1st Floor |
| 378 | In 2nd Floor |
| 379 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) |
| 380 | Above 30 mm & upto 37 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. |
| 381 | In Ground Floor |
| 382 | In 1st Floor |
| 383 | In 2nd Floor |
| 384 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation and upto roof of ground floor/upto 4 m |
| 385 | Tor steel/Mild SteelUsing reinforcement steel of SAIL/ TATA/RINL |
| 386 | In Ground Floor |
| 387 | In 1st Floor |
| 388 | In 2nd Floor |
| 389 | Brick work with 1st class bricks in cement mortar (1:6) |
| 390 | In substructure |
| 391 | In superstructure |
| 392 | In Ground Floor |
| 393 | In 1st Floor |
| 394 | In 2nd Floor |
| 395 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. |
| 396 | In superstructure |
| 397 | In Ground Floor |
| 398 | In 1st Floor |
| 399 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour.In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement |
| 400 | 35 mm. thick |
| 401 | In Ground Floor |
| 402 | In 1st Floor |
| 403 | Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete. |
| 404 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:6 cement mortar |
| 405 | 20 mm thick plaster |
| 406 | In Ground Floor |
| 407 | In 1st Floor |
| 408 | In Mumty Room |
| 409 | 15 mm thick plaster |
| 410 | In Ground Floor |
| 411 | In 1st Floor |
| 412 | In Mumty Room |
| 413 | With 1:4 cement mortar10 mm thick plaster |
| 414 | In Ground Floor |
| 415 | In 1st Floor |
| 416 | In Mumty Room |
| 417 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. |
| 418 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). |
| 419 | Sal : local |
| 420 | In Ground Floor |
| 421 | In 1st Floor |
| 422 | In Mumty Room |
| 423 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) |
| 424 | 40mm X 6mm, 125mm Length |
| 425 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made) |
| 426 | 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.Sishu, Gamar, Champ, Badam, Bhola, Mogra, Hallak. |
| 427 | In Ground Floor |
| 428 | In 1st Floor |
| 429 | In Mumty Room |
| 430 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. |
| 431 | 75mm. X 60mm. X 3.15mm. |
| 432 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:150mm long x 10mm dia. bolt. |
| 433 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. |
| 434 | Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] |
| 435 | In Ground Floor |
| 436 | In 1st Floor |
| 437 | Supplying best Indian sheet glass panes set in putty (as per I.S specification) and fitted and fixed with teak wood beads and nails complete. (In all floors for internal wall & upto 6 m height for external wall) |
| 438 | 4 mm thick |
| 439 | In Ground Floor |
| 440 | In 1st Floor |
| 441 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor) |
| 442 | One CoatSolvent based interior grade Acrylic Primer |
| 443 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : |
| 444 | Two Coats Standard Quality |
| 445 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. |
| 446 | One Coat |
| 447 | In Ground Floor |
| 448 | In 1st Floor |
| 449 | In Mumty Room |
| 450 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. |
| 451 | Ground Floor Two CoatsNormal Acrylic Emulsion |
| 452 | In Ground Floor |
| 453 | In 1st Floor |
| 454 | In Mumty Room |
| 455 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 456 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : |
| 457 | On timber or plastered surface :With super gloss (hi-gloss) -Two coats (with any shade except white) |
| 458 | Supplying, fitting & fixing UPVC pipes AType and fittings conforming to IS:13592- 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc ifecessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. |
| 459 | UPVC Pipes: |
| 460 | 110 mm. Dia. |
| 461 | UPVC Fittings: |
| 462 | Plain Tee |
| 463 | 110 mm. Dia. |
| 464 | Shoe |
| 465 | 110 mm. Dia. |
| 466 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected toone another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete.Payment to be made on the basis of calculated weight of structuralmemebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. |
| 467 | For roof truss works |
| 468 | Span up to 12 Mtr |
| 469 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 470 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary: |
| 471 | On steel or others metal surface with super gloss (hi-gloss). |
| 472 | Two coats (with any shade except white) |
| 473 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap(Payment to be made on area of finished work). |
| 474 | In Roof:-With 0.5 mm thick sheet |
| 475 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. |
| 476 | For structural members of specified sections weighing less than 22.5 Kg./m |
| 477 | COURT EJLASH ---------------------------Wood work in posts, post plates, rafters, battens, truss members, purlins etc. fitted and fixed complete (excluding the cost of bolts, paints, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals)Sal : Siliguri. |
| 478 | In 1st Floor |
| 479 | In 2nd Floor |
| 480 | In 3rd Floor |
| 481 | In 4th Floor |
| 482 | Wood work in upper rails of railing, hand rail of staircase, balcony etc. includig necessary bend, moulding fitted and fixed complete (for purpose of payment section will be measured in the square).1st class best Indian teak. |
| 483 | In 1st Floor |
| 484 | In 2nd Floor |
| 485 | In 3rd Floor |
| 486 | In 4th Floor |
| 487 | Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping]16mm |
| 488 | In 1st Floor |
| 489 | In 2nd Floor |
| 490 | In 3rd Floor |
| 491 | In 4th Floor |
| 492 | Partition of teak veneer [1 mm] as per design fitted and fixed complete (excluding the supporting frame work & necessary teak wood battens):4mm thick commercial quality |
| 493 | In 1st Floor |
| 494 | In 2nd Floor |
| 495 | In 3rd Floor |
| 496 | In 4th Floor |
| 497 | French polishing to wood work including preparing surface (ordinary gloss) |
| 498 | On new wood work |