Public Works Department-PWD has published Construction Of New Bus Terminal At Roopnagar ( Punjab ) . Submission Date for this Tender is 30-10-2021. Building Work Tenders in ROPAR Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Oct-2021 | corrigendum date | Date | 30-10-2021 |
Sl. No. | Item Description |
1 | Civil Works |
2 | Construction of Bus Stand Building in RCC Frame Structure (Basement + 2 Storey ) |
3 | Excavation in Soil (any type) using Hydraulic Excavator CK 90with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
4 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
5 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying inplinthin 15 cm layers including ramming, watering and consolidating including all leads. |
6 | Earth filling under floor with surplus ordinary soil or soil containing gravel or kankar upto40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres. |
7 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer"s specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth- 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
8 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type |
9 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using Rough Kota Stone |
10 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
11 | Reinforced cement concrete M-30 mechanically batch mixed using batch type concrete mixer as per IS:1791 and without vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
12 | Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. (Rate to be paid for Super structure since the work is more than 1.50 mtr depth) |
13 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
14 | Reinforced cement concrete M-20mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
15 | Lintels |
16 | Total Qty for All Floor |
17 | Extra rate for First Floor |
18 | Extra rate for Second Floor |
19 | Shelves |
20 | Total Qty for All Floor |
21 | Extra rate for First Floor |
22 | Slab |
23 | column 6+2 |
24 | Reinforced cement concrete M-30mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
25 | Slab |
26 | Total Qty for All Floor |
27 | Beams |
28 | Total Qty for All Floor |
29 | Facia/Parapet |
30 | Total Qty for All Floor |
31 | Extra rate for First Floor |
32 | Extra rate for Second Floor |
33 | Lift Walls |
34 | Total Qty for All Floor |
35 | Reinforced cement concrete M-40mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
36 | Columns |
37 | Total Qty for All Floor |
38 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note:where concrete mixer is already included in the rate the same shall be deducted ) |
39 | Qty. same as RCC in Circular Columns of all Floors |
40 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
41 | Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey |
42 | Qty. same as RCCAll Items |
43 | Qty. same as RCCAll Items |
44 | Qty. same as RCCAll Items |
45 | Qty. same as RCCAll Items |
46 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
47 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
48 | Total Qty for All Floor |
49 | Extra rate for height 4 to 5mtr at Ground Floor |
50 | Extra rate for First Floor |
51 | Extra rate for height 4 to 5mtr at First Floor |
52 | Extra rate for Second Floor |
53 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
54 | Total Qty for All Floor |
55 | Extra rate for height 4 to 5mtr at First Floor |
56 | Extra rate for First Floor |
57 | Extra rate for Second Floor |
58 | Centring and shuttering for columns (Square or rectangular or poly gonal in plain) |
59 | Total Qty for All Floor |
60 | Extra rate for height 4 to 5mtr for Ground Floor |
61 | Extra rate for height 5 to 6mtr for Ground Floor |
62 | Extra rate for First Floor |
63 | Extra rate for Second Floor |
64 | Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc |
65 | Total Qty for All Floor |
66 | Extra rate for height 4 to 5mtr at Ground Floor |
67 | Extra rate for height 5 to 6mtr at Ground Floor |
68 | Extra rate for First Floor |
69 | Extra rate for height 4 to 5mtr at First Floor |
70 | Extra rate for height 4 to 5mtr at Second Floor |
71 | Centring and shuttering for carbels, parapet, fascias and other similar items including edges. |
72 | Total Qty for All Floor |
73 | Extra rate for First Floor |
74 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
75 | Total qty for all floor |
76 | Extra rate for First Floor |
77 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
78 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
79 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
80 | Total of all Floors (A+B+C+D) :- |
81 | Extra rate for height 4 to 6 mtr at Ground Floor |
82 | Extra rate for First Floor |
83 | Extra rate for height 4 to 6 mtr at First Floor |
84 | Extra rate for Second Floor |
85 | Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machineprecast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005. |
86 | Total all Floors |
87 | Extra rate for height 4 to 6 mtr at Ground Floor |
88 | Extra rate for First Floor |
89 | Extra rate for Second Floor |
90 | Extra rate for height 4 to 6 mtr at Second Floor |
91 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. |
92 | Total all Floors |
93 | Extra rate for height 4 to 6 mtr at Ground Floor |
94 | Extra rate for First Floor |
95 | Extra rate for height 4 to 6 mtr at First Floor |
96 | Extra rate for Second Floor |
97 | 115 mm thick brick wall laid in cement mortar 1 :4 without reinforcement in super structure. |
98 | Total qty for all floor |
99 | Extra rate for First Floor |
100 | 12.5mm thick cement plaster 1:5. |
101 | Extra height for 4 to 6 mtr at Ground Floor |
102 | Extra rate for First Floor |
103 | Extra height for 4 to 6 mtr at First Floor |
104 | Extra rate for Second Floor |
105 | 20 mm thick cement plaster 1:5 in two coats work. |
106 | Extra height for 4 to 6 mtr at Ground Floor |
107 | Extra rate for First Floor |
108 | Extra height for 4 to 6 mtr at Ground Floor |
109 | Extra rate for Second Floor |
110 | 12.5 mm thick cement plaster 1:4. |
111 | Extra height for 4 to 6 mtr at Ground Floor |
112 | Extra rate for First Floor |
113 | Extra height for 4 to 6 mtr at Ground Floor |
114 | Extra rate for Second Floor |
115 | 20 mm thick cement plaster 1:4. |
116 | Extra height for 4 to 6 mtr at Ground Floor |
117 | Extra rate for First Floor |
118 | Extra height for 4 to 6 mtr at Ground Floor |
119 | Extra rate for Second Floor |
120 | Extra rate for Smooth Surface of Ceiling |
121 | Extra rate for Smooth Surface of Fascia |
122 | Extra rate for Smooth Surface of Walls |
123 | Bearing Plaster of 10 mm thick cement mortar 1:3 cement sand finished with a floating coat of neat cement and thick coat of Lime wash / P.O.P. on top of walls when dry for bearing of R.C.C. slabs & beams. |
124 | Plastering on underside of ceiling 10 mm thick cement plaster 1:3 |
125 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp U-PVC pipes (working pressure 4kgf. / sqcm) pipe 110 mm dia. |
126 | Providing and fixing 110 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
127 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
128 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
129 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
130 | Providing and fixing in position gratings 150mm x 150mm for gully trap. PVC grating |
131 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
132 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
133 | Total All Floor |
134 | Extra rate for First Floor |
135 | Extra rate for Second Floor |
136 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
137 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
138 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
139 | Total Qty for All Floor |
140 | Extra rate for First Floor |
141 | Extra rate for Second Floor |
142 | Providing and laying on smooth roof surface with CFC free, closed cell free Rigid Polyurethane foam slab over deck insulation conforming to IS -12436 (density of foam being 36±2 kg/m3) having thermal conductivity not more than 0.024 W/m.K, over a coat of cold adhesive like CPRX compound, laying 400 G polythene sheet over PUF slab and providing a wearing course of 40 mm thick cement screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of engineer-in-charge 70 mm thick Polyurethane foam (PUF) rigid insulation board |
143 | Conglomerate floor 40mm thick cement concrete topping 1:2:4(Using mechanical mixer for mixing of material). |
144 | Tile Terracinglaid dry over a bed of 6mm thick cement sand mortar 1:6 grouted with cements sand mortar 1:4 and top surface to be left clean after wire brushing |
145 | 20 mm thick cement plaster in damp proof course 1:3 with two coats of bitumen 1.65 Kg. per Sqm. hot laid and sanded. Vertical |
146 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
147 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. |
148 | Total Qty for All Floor |
149 | Extra for First Floor |
150 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
151 | Total Qty for All Floor |
152 | Extra for First Floor |
153 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 18mm to 20mm Slabs sizes above 0.50 sqm |
154 | Total Qty for All Floor |
155 | Extra for First Floor |
156 | Extra for Second Floor |
157 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm |
158 | Total Qty for All Floor |
159 | Extra for First Floor |
160 | Providing and Laying Out DoorPrecast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurrycontainingpigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
161 | Extra labour for projected nosing of stair case of any shape and design |
162 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
163 | Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects. |
164 | 20mm thick grey polished skirting or dado consisting of bottom layer of 16mm thick cement sand plaster 1:3 and finished 3mm thick topping of neat cement rubbed and polished including rounding of junction with floors. |
165 | Basement |
166 | Supply & Fixing ofdoor frames (Chowkhats) consisting framefabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277(base steel as per IS:513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones(as per approved colour) , 3 Nos100mm but hinges 2mm thick, 6 Nos1.2mm thick CRCA electroplated stiffner, 6 NosM.S hold fast with split and tail welded to stiffner plate 200mm long,Receiver for aldrop,M.S tie rod 50mm x 25mm to be fixed at bottomfinished with powder coated total thickness of coating0.60mm of approved shade, fixed in position, including the cost of cement concrete for1:2:4 for fixing lugs complete in all respects as per drawing,design, specification & entire stasfication of Enginner-in-Charge. |
167 | Doors frame of size 80mm x 50mm with 37 mm wide single rebate for 35mm door shutter . |
168 | Supply & Fixing ofWindow frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanishedsheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating0.58mm of approved shade, fixed in position by means of PVC & metal hold fastner with PVC cap complete in all respects as per drawing,design, specification & entire stasfication of Enginner-in-Charge. |
169 | Windows Outer frame of size 72mm x55mm and central mullion 72 mm x 50mm with Double rebate. |
170 | Supply & Fixing of Window shutter consisting framefabricated from sheet roll formed out of 0.58mm thick galvanishedsheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating0.58mm of approved shade, fixed in position fixed in position by means of screws , complete in all respects as per drawing,design, specification & entire stasfication of Enginner-in-Charge. |
171 | Glazed Windows shutter Section 47mm x20mm (Without Glass) |
172 | Wire Mesh Windows shutter Section 40mm x 20mm with S.S wire mesh 32 guage flymesh with 144 holes per square inch |
173 | Providing & fixing fixed beeding 12mm x 12mm for fixed glass with ECO fixed gasket (EPDM) |
174 | Providing and fixing glazing indoor, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of Gasket /beading shall be paid as per respective item) |
175 | Float glass panes of 5.5 mm thickness |
176 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : |
177 | For fixed portion & Chaukhat |
178 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
179 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) |
180 | Providing & fixing ACP Sheets of various thickness High Class ISI markedcomplete in all respect as per the directions of Engineer-in-charge. 6mm thick ACP Sheet |
181 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work. |
182 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
183 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm |
184 | Providing & fixing 6" stainless steel handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
185 | Providing & fixing 8" stainless steel tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
186 | Providing and fixing bright finished brass 100 mm mortise latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
187 | Providing & fixing 75mm with Plate 125mm X 32 mm anodized aluminum Mat Finish handles ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
188 | Providing & fixing 100 X 10 mmanodized aluminum Mat Finish tower bolts ISI marked on door & window frames complete in all respect as per the directions of Engineer-in-charge. |
189 | Providing Polyester Powder coating 50 micron any coloured specified to alumnum fittings various sizes including carriage of material from market to workshop & workshop to site of work.. |
190 | Tower Bolt 100mm to 300 mm Long |
191 | Handles all Sizes |
192 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. 1 (size of door up to 700mm) |
193 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
194 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete I.S.I Designation No. III (size of door 851mm to 1000mm) |
195 | Providing & fixing of knobset made of stainless steel body, having provision of latch and bolt, 3 nos key set, inside push lock model ETL-101A, Finish SS/PB/AB make-ENOX or any equivalent (Lock should be releasable from out side in case of emergency) as per requirement for unisex toilet for PwD complete as per specifications,Harmonised guidelines for PwD and as desired by engineer-in-charge. |
196 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System heldwithSpiderFittingsofSS-316GradeSteelofapprovedmanufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider.& bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non star bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. |
197 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System heldwithSpiderFittingsofSS-316GradeSteelofapprovedmanufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider.& bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non star bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. |
198 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge |
199 | Providing and supplying aluminum extruded tubular and other aluminum sections as per the architectural drawings and approved shopdraw ings , the aluminum quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminum frame work. Nothing extra shall be paid on this account). The weight of aluminum extruded section shall be taken for purpose of payment. |
200 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: |
201 | (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including |
202 | (b) Fabricating and supplying serrated M.S. hot dip galvanised / aluminum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality andfixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. |
203 | (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. |
204 | (d) Providing and fixing in position flashings of solid aluminum sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. |
205 | (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminum grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architecturaldrawings, as per item description, as specified, as per theaproved shop drawings and as directed by the engineering-Charge. |
206 | Note:- 1. The cost of providing extruded aluminum frames, shadow boxes, extruded aluminum section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separatelyunder relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. |
207 | Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science &echnologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025. |
208 | 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr 2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml 4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330- 10 testing method for a range upto 50 mm 5. Seismic Movement Test (upto 30 mm) as perAMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site. 6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml |
209 | Providing and fixing 8.0mm thick toughened Plate glass(weight not less than 20 kg/ sqm) complete in all respect. |
210 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. |
211 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns(minimum), including factory painted after bending.)in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
212 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
213 | Iron grated doors, including pintle hinges and arrangements. |
214 | Providing Polyester Powder coating 60to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work. |
215 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- |
216 | 35mm thick |
217 | Providing & Fixing decorative high pressure laminated sheet 1mm (2 Star) thick with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
218 | Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together , at the end, by and locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exect size of opening where rolling shutter is to be fixed) |
219 | Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications. |
220 | Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one sidefixed and one side fixed with slotted holesto allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
221 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
222 | Total Qty for All Floor |
223 | Extra rate for First Floor |
224 | Extra rate for Second Floor |
225 | Extra rate for Third Floor |
226 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
227 | Extra rate for using steel produced by primary producer complete in all respect as per the directions of Engineer-in-charge. |
228 | Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machineprecast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005. |
229 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
230 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
231 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
232 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
233 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
234 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
235 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
236 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
237 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
238 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
239 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
240 | Construction ofPlinth protection complete as per drawing. |
241 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
242 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type |
243 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
244 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
245 | Conglomerate floor 40mm thick cement concrete topping 1:2:4(Using mechanical mixer for mixing of material). |
246 | 12.5 mm thick cement plaster 1:5complete in all respect as per specifcation, drawing andto theentire satisfication of Engineer-In-Charge. |
247 | Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications. |
248 | Granular Sub-Base (Table 400-1) Construction of granular sub-base by providing material as per grading-III ( Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications |
249 | Cement concrete 1:3:6 with stone ballast or shingle 40 mm guage. using concrete mixing volumetric type |
250 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufacturedby block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. |
251 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
252 | Construction of RCC Bus Stoppercomplete as per drawing |
253 | Precast Cement Concrete Kerb Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
254 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
255 | Steel work fixed independently without connecting plates including cutting hoisting and fixing in position Tees angles & channels |
256 | PUBLIC HEALTH SERVICES |
257 | Sub Work-1 Internal Water Supply, Sewerage, Sanitation |
258 | Sub Head-1 Internal Sewerage System |
259 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type A |
260 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
261 | 75mm o/d single socket SWR UPVC pipe lines laid complete |
262 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
263 | For 110mm i/d pipes |
264 | Elbow 90 Degree (All side socketed) |
265 | Vent Cowls |
266 | Coupler |
267 | Single Tee With Door |
268 | For 75mm i/d pipes |
269 | Elbow 90 degree (all side socket) |
270 | Vent Cowls |
271 | Coupler |
272 | Single Tee With Door |
273 | Floor Trap 110mm x 75mm |
274 | Providing & Fixing in position M.S or heavy flat iron clamps made out ofM.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. |
275 | M.S. Holder bats clamps for 100mm i/d |
276 | M.S. Holder bats clamps for 75mm i/d |
277 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc.as per standard design minimumdepth of water should be 150 mm with a minimum seal 50mm. |
278 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
279 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
280 | 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
281 | Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. |
282 | uPVC Pipe 6 Kgf/cm2 50mm i/d |
283 | Sub Head-2 Internal Water Supply System |
284 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
285 | CPVC SDR 11 Pipe & fitting 16mm o/d |
286 | SDR 11 CPVC pipes & fittings 20mm o/d |
287 | CPVC SDR 11 Pipe & fitting 25mm o/d |
288 | CPVC SDR 11 Pipe & fitting 32mm o/d |
289 | CPVC SDR 11 Pipe & fitting 40mm o/d |
290 | CPVC SDR 11 Pipe & fitting 50mm o/d |
291 | Providing and laying, jointing, fixing, testing ISI MarkedG.I. Pipe (as per IS 1239) B- Class,premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete. |
292 | 80mm i/d Vertical in Ducts |
293 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm |
294 | qty same as GI P 15mm i/d to 25 mm |
295 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
296 | Through wall 11.43 cm thick |
297 | Through wall 22.86 cm thick |
298 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879in G.I. Pipe lines complete in all respect. |
299 | 15mm i/d G.I. Union |
300 | 20mm i/d G.I. Union |
301 | 25mm i/d G.I. Union |
302 | 32mm i/d G.I. Union |
303 | 40mm i/d G.I. Union |
304 | 50mm i/d G.I. Union |
305 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
306 | 20mm i/d Brass Ball valves |
307 | 25mm i/d Brass Ball valves |
308 | 32mm i/d Brass Ball valves |
309 | 40mm i/d Brass Ball valves |
310 | 50mm i/d Brass Ball valves |
311 | Painting G.I. Pipes and Specials with synthetic enamelPaint in all shades as per I.S.I. specification on existing or new work, two coats paints including cleaning rubbing surface, etc. |
312 | 15mm & 20mm i/d G.I. Pipe |
313 | 25mm & 32mm i/d G.I. Pipe |
314 | 40mm & 50mm i/d G.I. Pipe |
315 | Sub Head - 3 Sanitary Installation |
316 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
317 | Providing and fixing jet spray with 2"-6" long PVC pipe.With PTMT nut |
318 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
319 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
320 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
321 | Size 49 cm dia (above counter round) |
322 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
323 | Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm |
324 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut |
325 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
326 | Providing and fixingin position C.P. brass soap dishof approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
327 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
328 | C.P. brass Bib cock long nose/ long body without flange |
329 | C.P Brass bib cock foam flow without flange |
330 | Providing & Fixing in postion CP Brass Spout Operated Pillar Tap with base flange (for foot operated valve) of approved make (to the approval of Engineer-in-charge)complete in all respect (instead of Pillar tap in Lavatory Suites). |
331 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
332 | C.P.brass 15mm Angle valve without flange |
333 | C.P.brass 15mm Concealed stop cock with flange |
334 | C.P.brass 15mm Concealed stop cock male |
335 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
336 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long |
337 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backingfixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on topcomplete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) |
338 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. Aluminium khunti with 3 pegs |
339 | Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. |
340 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks |
341 | Providing and fixing in position automatic brass Ball Cock in tanks. Brass Ball Cock with rod andPlastic Ball |
342 | Brass Ball Cock with rod andPlastic Ball 32mm i/d |
343 | Brass Ball Cock with rod andPlastic Ball 25mm i/d |
344 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
345 | G.I. tank nipple 25mmi/d |
346 | G.I. tank nipple 40mmi/d |
347 | Construction of RCC BB Plateform on Roof for HDPE water storage tanks complete as per drawing & specifications & as desired by Engineer-in-Charge |
348 | For 2000 ltr Water Tank |
349 | For 1000 ltr Water Tank |
350 | Providing and fixingin position SS Grab Bar Grade 304of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. |
351 | 35mm dia900mm (36”) long |
352 | 35mm dia 1200mm (48”) long |
353 | Foldable U Type 762mm long |
354 | Sub Head-4 Flooring and Wall Tile |
355 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
356 | Ground Floor |
357 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
358 | Total All Floor |
359 | Extra rate for First Floor |
360 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . |
361 | Total All Floor |
362 | Extra rate for First Floor |
363 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
364 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
365 | Total All Floor |
366 | Extra Rate for First Floor |
367 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
368 | Total All Floor |
369 | Extra Rate for First Floor |
370 | Sub Head -5 Water Coller & Air Conditioning |
371 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
372 | Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer |
373 | Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer |
374 | Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet boxof suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:- Automatic Voltage Stablizer 2 KVA |
375 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
376 | Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Make:- Carrier, Hitachi, Voltas, Blue Star, Daikin or equilantwith 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of 3 mtr concealing Copper pipes within building and installing charges complete in all respects |
377 | Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Star Make:- Toshiba, Mitsubishi Electric, Daikin, O" General, Hitachi with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of 3mtr Copper pipes within building and installing charges complete in all respects |
378 | Providing laying hard soft copper concealing of copper pipes of various dia as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. |
379 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. uPVC Pipe 6 Kgf/cm2 40mm i/d |
380 | Internal Electrical Services |
381 | Providing Internal Electrical Installations: |
382 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Make: SWITCH ACCESSORIES Legrand (Myrius), NorthWest (Nova), Havells (Crabtree). |
383 | Wiring fan point with sheet metal fan box |
384 | Wiring light point |
385 | Wiring call-bell point |
386 | Wiring 3 pin 6 Amp. wall socket point |
387 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point |
388 | Wiring 3 pin 16/20 amp. power plug control point |
389 | Wiring light point with double control switches. |
390 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPEWIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- Make: ACCESSORIES Legrand (Myrius), NorthWest (Nova), Havells (Crabtree). |
391 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universalsocket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
392 | RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- Make: ACCESSORIES Legrand (Myrius), NorthWest (Nova), Havells (Crabtree). |
393 | Wiring Telephone socket point RJ11 (one module) |
394 | Wiring Networking socket point RJ45 (one module) |
395 | COPPER WIRES & CONDUIT PIPE: |
396 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-MAKE: POLYCAB, RR KABEL, HAVELLS. |
397 | Overall size 1sq.mm (Un-sheathed) |
398 | Overall size 1.5sq.mm (Un-sheathed) |
399 | Overall size 2.5sq.mm (Un-sheathed) |
400 | Overall size 4sq.mm (Un-sheathed) |
401 | Overall size 10sq.mm (Un-sheathed) |
402 | Overall size 16sq.mm (Un-sheathed) |
403 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- Make: DIPLAST, CANON, AKG. |
404 | Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
405 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
406 | Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed |
407 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
408 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
409 | PVC flexible pipe 40mm dia. |
410 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- |
411 | PVC compression Socket gland 40mm dia. |
412 | HEAVY GUAGE WELDED CONDUIT PIPES: Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Make: DIPLAST, CANON, AKG. |
413 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
414 | COPPER EARTHING :- (Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
415 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
416 | Additional Length 20mm x 3mm thick Copper Tape . |
417 | Additional Length 20mm x 3mm thick Copper Tape . |
418 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- Make: ABB, Schneider (Neo Break), L&T (Exora), Havells. |
419 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
420 | MCB Double Pole 40amp. (10kA, Curve-C) |
421 | MCB Triple Pole 40amp. (10kA, Curve-C) |
422 | MCB Four Pole 40 amp. (10kA, Curve-C) |
423 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB"s: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO"s/ RCCB"s in the distribution board (For SP&N distribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- Make: ABB, Schneider, L&T, Havells. |
424 | SP&N Double Door Distribution Board 8 way each |
425 | TP&N Vertical Double Door Distribution Board4 way each. |
426 | TP&N Horizontal Double Door Distribution Board 8 way each. |
427 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
428 | Cable End Box for SPN 8 way |
429 | Cable End Box for TPN Vertical 4/8/12Way |
430 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB"s: (USED AS A OUTGOING PANEL FOR EMERGENCY & NORMAL LOAD DB"S ON DIFFERENT FLOOR): Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB"s as incomer and outgoings SP/TPminiature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- Make: ABB, Schneider, Siemens, L&T, Havells. |
431 | TP&NDouble Door Vertical DB"s 4 way each (With provision of FP MCCB upto 125amp) |
432 | TP&NDouble Door Vertical DB"s 8 way each (With provision of FP MCCBupto 125amp.) |
433 | MCCB"s (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc. Make: ABB, Schneider, L&T, Havells. |
434 | MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
435 | MCCB Four Pole 125amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
436 | INDOOR LT PANELS: |
437 | LT PANELS & MCCB"s (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication: Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
438 | Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of MCCB"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB"s) as per following:- Make: ABB, L&T, Havells. |
439 | MAIN LT PANEL: |
440 | LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB"s40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm) (DETAIL SEE IN PANEL INVENTORY) |
441 | SUB LT PANEL (EMERGENCY): |
442 | LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 8Nos. outgoing MCCB"s40amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm)(DETAIL SEE IN PANEL INVENTORY) |
443 | MCCB"s (MOULDED CASE CIRCUIT BREAKER): Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevantPWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc Make: ABB, Schneider, L&T. |
444 | MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
445 | MCCB Four Pole 125amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
446 | MCCB Four Pole 250amp., 415volts, =36kA Microprocessor Based Adjustable Thermal and Magnetic Setting |
447 | ON LOAD CHANGEOVER SWITCH (Without Sheet Enclosure): Supply and erection ofOn Load Change over Switch with advance neutral UNIT (Panel mounting Cubical type) in the existing Cubical Panel Confirms to IS 13947 (Part-3) complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- Make: Havells, Crystal, C&G. |
448 | On Load Change Over Switch Four Pole 125amp., 415volts |
449 | INDOOR LT CABLES, CABLE TRAY & DWC PIPE: |
450 | XLPEINSULATED UN-ARMOURED CABLES (LOOSE):- Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Make: Polycab, Havells, KEI. |
451 | Overall size 50sq.mm (3½ Core) Un-armoured (Loose) |
452 | Overall size 150sq.mm (3½ Core) Un-armoured (Loose) |
453 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
454 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
455 | Double walled corrugated (DWC) HDPE pipe160/136mm (outer/ inner dia.) |
456 | LED"S FIXTURES & FANS: |
457 | Supply and erection of Highbay LED luminaire 80watt with Pressure die cast aluminium housing, IP66 (With Beam Angle 60/90° as per requirement at site ) with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt complete in all respects as approved and desired by the Engineer in-charge at site. The certification and Specifications of the LED Fitting"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton LCNP-80-CD60HPM, HAVELL"S SAUCERGENXPROHBP80WLED757P90/60DBOLTG, Wipro LH21-UNO |
458 | Supply and erection of Slim Recessed mounted, Round downlighter 40 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt complete in all respects as approved and desired by the Engineer in-charge at site . The certification and Specifications of the LED Fitting"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton CDR-216-40-57-SL-NWH, Wipro LD56-501-060-40-XX, Havell"s Phillips |
459 | Supply and erection of LED Batten 20watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Jaquar LGLZ01X020XC, Philips BN02IC LED20S PSU CW GRS2, Havell"s ENDURALINEARNEOBS20WLED865SPCWH,Crompton LDL-20-CDL, Wipro LL20-281-XXX-65 ALI, Panasonic PBTM08208, Bajaj BCLAB 20W WH LED P |
460 | Supply and erection of LED batten 40watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Wipro LL24-541-XXX-57XX, Bajaj Cat No. BCLAB SP 44L LED CW PC SD, Jaquar Cat No. LGLZ01X040XC, Philips Cat No. BN100C LED40S-6500 PSU L120 GR, Crompton CCS-100-65-DP-NWH, Havell"s STOUTPLUS1200BS40WLED857SPCWH |
461 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Philips RC380B LED36S-6500 G4 L60 W60 PSU OD WH OC, Jaquar LULTU1SO36XC, Crompton LCTLRNE-36-FO-CDL (2X2), Wipro CRCO10R038HP57GL1, Bajaj BZRSQL 36W GZi WH |
462 | Supply and erection of Surface mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.The certification and Specifications of the LED Fitting"s should beas approved by O/o Advisor (Techlical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Make: Crompton POLARIS NEO-III LCTLSNE-36-FO-CDL (2X2), Wipro CRCO10S036HP57G2, Havells |
463 | Supply and erection of Ceiling Fan 1200mm (48") with double ball bearing including flexible wire & petty material etc. for connections and testing complete in all respects as approved and desired by the Engineer in-charge at site. Makes: Crompton High SpeedOpel White, Havell"s Velocity HS |
464 | Supply and erection of Wall mounted Air Circulation Fan 750MM Sweep including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. Make: Crompton ACVORTEX30WM, Havell"s Turbo Force |
465 | Supply and erection of Heavy duty Exhaust Fans 300mm, 900RPM with aluminium louver shutter, double ball bearinglonger life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. Make: Crompton EXHD300-6-1, Havells Turbo Force SP. |
466 | Add extra cost of Cutlural Cess @ 1% on Total cost as items mentioned above |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy