Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-10-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-10-2021 |
| Sl. No. | Item Description |
| 1 | B/R SERVICES/WORKS |
| 2 | Demolition Cement Concrete (Un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and Removing debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed. |
| 3 | Demolition Cement Concrete (Reinforced) of any description and in any Position not otherwise specifically provided, complete all as specified and as directed. |
| 4 | Demolition Pre-cast Concrete Block Walling, built in Cement Mortar of any description, complete all as specified and as directed. |
| 5 | Dismantling Timber Scantling 40 Sq Cm and Over in Section in Unframed Work, complete all as specified and as directed. |
| 6 | Dismantling Timber Fillets, Rails, Posts, Rafters, Purlins, etc. Under 40 Sq Cm in Section in Unframed Work, complete all as specified and as directed. |
| 7 | Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame) not exc. 1.50 Square Metre Each, complete all as specified and as directed. |
| 8 | Taking down Chowkat or Frame of any description (without Taking Off Shutter from the Frame), exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed. |
| 9 | Taking down/ out Unserviceable/Worn out Wire Cloth/ Netting of any description, fixed with Beads, etc., complete all as specified and as directed. |
| 10 | Hacking out Old Broken Glass (any thickness, size, quality or description) from Wooden or Metal Frame or Stone, Concrete or Brick surrounds including hacking out old Putty or removing Beads, etc., punching or drilling out old Glazing Pins/Spring Clips, complete all as specified and as directed. |
| 11 | Dismantling Wrought Iron or Mild Steel Work of any description not otherwise provided for, complete all as specified and as directed. |
| 12 | Dismantling Plain or Corrugated Steel Sheeting of any gauge and thickness, Segregating the Serviceable Plain or Corrugated Steel Sheeting and Stacking properly at Sites and Keep in Safe Custody for re-use, complete all as specified and as directed. |
| 13 | Dismantling Ceiling Frame (Snap Grid) with Hangers of any descriptions, complete all as specified and as directed. |
| 14 | Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards/ Slabs/ Blankets of any descriptions including Cover Fillets, complete all as specified and as directed. |
| 15 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and Removing debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed. |
| 16 | Demolition Stone Slabs and Tiles of any description or thickness in Floors, Aprons, etc. and Removing Debris, etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed. |
| 17 | Taking down Cement Plaster including Raking out Joints, Hacking for Key, scrubbing down with Water and Removing Debris, etc. etc. to a distance not exc. 100.00 Metre, complete all as specified and as directed. |
| 18 | M&L Hardcore broken Stone or Boulders, gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15 Cm thick, watered and well rammed to a True surface, complete all as specified and as directed. |
| 19 | M&L Cement Concrete 1:3:6 (20mm graded stone aggregate) in Lintels upto 1.50 Metre Clear Span, Cills, Steps; Seismic and other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets and Railings upto 60 CM in Height, Copings, Kneelers, Apex Stones, Bed Plates, Holdfats, Filling Back of Steel Door Frames, Kerbs, Water Troughs and the like including weathering, slightly rounded or chamfered angles and throating, etc. including necessary Formwork, complete all as specified and as directed.NOTE : Cost of Formwork will deem to include in the Quoted Unit Rate. |
| 20 | M&L Cement Concrete 1:4:8 (40mm graded aggregate) in Foundations, Filling and Mass Concrete including necessary Formwork, complete all as specified and as directed.NOTE : Cost of Formwork will deem to include in the Quoted Unit Rate. |
| 21 | M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Roof Beams, Lintel Bands, Cantilevers, Bressumers, Lintels over 1.50 Metre Span, etc., complete all as specified and as directed.NOTE : Reinforcement & Formwork will be Measured and Paid for separately under appropriate Items. |
| 22 | M&L Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Slabs supported on Walls, Beams and Columns in Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs and in Shelves and the like, complete all as specified and as directed.NOTE : Reinforcement & Formwork will be Measured and Paid for separately under appropriate Items. |
| 23 | M&L Formwork to Sides and Soffits of Floor or Roof Beams, Girders, Beam Haunchings, Bress-summers, Lintels, Cantilevers, Shelves including Supports, Overhangs, etc. also splays between Floors and Beams, etc., Flat, Rough Finished surfaces of Concrete, complete all as specified and as directed. |
| 24 | M&L Formwork to Soffits of Suspended Slabs such as Roof Slabs, Floor Slabs, Landings and Similar Works; not exc. 200mm thick (Horizontal or Sloping), etc., Flat, Rough Finished surfaces of Concrete, complete all as specified and as directed. |
| 25 | M&L Pre-cast Cement Concrete Block Masonry with Solid Blocks of Size 300x200x200mm or 300x200x100mm, having Compressive Strength of not less than 100 Kg/ Sq Cm (as per IS-2185) in Cement Concrete 1:3:6 (20mm graded stone aggregate), exc. 10 Cm in Width and Setting in Cement Mortar 1:6, complete all as specified and as directed. |
| 26 | M&L Cutting Holes in Brick/ Pre-cast Concrete Block Walling, not exc. Half Brick thick, built in Cement Mortar for inserting of Holdfasts, Lugs, etc. and Making Good to Dismantled portion with Cement Concrete 1:2:4 (20mm graded stone aggregate) or Cement Mortar 1:3 (as required) and Adjoining Surfaces in Cement Mortar 1:4, complete all as specified and as directed. |
| 27 | M&L Second Class Hardwood (well seasoned) Boarding 50mm thick in Frame Work to Ceiling, etc., fixed in any Position with Nails, complete all as specified and as directed. |
| 28 | M&L Second Class Hardwood (well seasoned) Plain Fillets, Cleansawn, Square, Rectangular or Triangular in Section, exc. 13.00 Sq Cm but not exc. 25.00 Sq Cm (50x50mm as STUDS), fixed with Nails, complete all as specified and as directed. |
| 29 | M&L Second Class Hardwood (well seasoned) Plain Fillets, Cleansawn, Square, Rectangular or Triangular in Section, exc. 6.00 Sq Cm but not exc. 13.00 Sq Cm (25x25mm as FORKING PIECE), fixed with Nails, complete all as specified and as directed. |
| 30 | M&L Second Class Hardwood (well seasoned) Plain Fillets, Wrought, Square, Rectangular or Triangular in Section, exc. 3.00 Sq Cm but not exc. 6.00 Sq Cm (40x12mm as COVER FILLETS), fixed with Nails, complete all as specified and as directed. |
| 31 | M&L Second Class Hardwood (well seasoned) Plain, Solid, Straight, Chowkats and Frame, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue pinned at Joints, complete all as specified and as directed. |
| 32 | M&L Second Class Hardwood (well seasoned) Panelled Shutter 35mm thick (any number Panels) Plain, Framed with Lock Rails, having Panels of 12mm thick BWP, Commercial Ply or 12mm thick Veneered Particle Board Medium density, Wood Particle Board with Commercial Face Veneers and fitted to Chowkat, complete all as specified and as directed. |
| 33 | M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 30mm thick, Open rebated and prepared to receive Glass, Gauze, etc. (without Sash Bars), Edges of Framing plain, chamfered or rounded. fitted with cut and mitred Beads for securing glass, etc.; sizes of Members of Shutters as specified inSSR Part I, Section 8, Clause 8.24(a) and fitted to Chowkat, complete all as specified and as directed. |
| 34 | M&L Second Class Hardwood (well seasoned) Small Fittings such as Brackets of any type, Latch and Hinge Blocks, Shaped Door and Window Stops and the like, including all necessary Labours; Articles not exc. 200 Cu Cm Each, complete all as specified and as directed.NOTE : Butt Hinge (if required/ordered) will be Measured and Paid under appropriate Item as \"Supply only\". |
| 35 | S&F Steel Windows with Side Hung Shutters including Projecting type Hinges with Steel Handle and Steel Peg Stay, complete with Glazing Bars, dovetailed or welded, complete all as specified and as directed. |
| 36 | S&F Steel Windows with Side Hung Shutters including Projecting type Hinges with Steel Handle and Steel Peg Stay, complete without Glazing Bars, dovetailed or welded, complete all as specified and as directed. |
| 37 | S&F Aluminium anodised Barrel Tower Bolt of size 150mm long, Extruded Section, complete all as specified and as directed. |
| 38 | S&F Aluminium alloy, anodised, Sliding Door Bolt 300mm long with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy, complete all as specified and as directed. |
| 39 | Supply only Stainless Steel Butt Hinge 50mm in size, complete all as specified and as directed. |
| 40 | S&F Stainless Steel Butt Hinge 100mm in size, complete all as specified and as directed. |
| 41 | S&F Aluminium Handle 150mm, Cast type, anodised, complete all as specified and as directed. |
| 42 | S&F Floor Door Stopper having Overall length of Cover Plate 140mm of Aluminium Alloy Body and Tongue, anodised, with Hard Drawn Steel Spring, fixed in Floor, complete all as specified and as directed. |
| 43 | S&F Mild Steel 375mm, Ordinary Rat Tail Rod pattern Springs including Roller and Roller Plate and Fixed-in-repairs, complete all as specified and as directed. |
| 44 | S&F Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples, complete all as specified and as directed. |
| 45 | S&F Sheet Glass3.0mm thick, Plain, Ordinary quality and Glazing with Oil Putty in Square not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed. |
| 46 | M&L TMT Bars 10mm dia and Over, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 47 | M&L TMT Bars 8mm dia in Stirrups, Spacers and Binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 48 | M&L Mild Steel Framed Work such as Grills, Gratings, etc, with Ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars, Barred Iron Doors, Ladders, Framed Balusters, Walkways, Railings, Frame Work of Water Tanks and Similar Works, conforming to Fe-290, Gde E-165, complete all as specified and as directed. |
| 49 | M&L Mild Steel Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes including Bolts, Hooks (Stay) for large Gates; Hook and Pintle Hinges: large Hasps and Staples; Hand Made Sliding Bolts; Clamps; Holdfasts (Flat Iron 25x3.0mm thick); Wall Ties and similar Small Articles conforming to Fe-290 Gde-E-165, complete all as specified and as as directed. |
| 50 | M&L Rolled Mild Steel in Joist, Channel, Angle, or Tee Sections in Vertical Post, conforming to Fe-410-W (Gde E-250) Quality \"B\", fixed independently, without Connecting Plates, etc. (cut to ordinary lengths i.e. within 20mm of the Length indicated), complete all as specified and as directed. |
| 51 | M&L Rolled Mild Steel Sections in Main and Cross Beams, Hip & Jack Rafters, Purlins where connected to Common Rafters, Running Rails and Guides for Sliding Doors, conforming to Fe-410-W (Gde E-250), Quality \"A\", fixed with Angle Cleats or Other Connecting Plates, complete all as specified and as directed. |
| 52 | M&L Running Welding in Repairs in Steel Works, thickness of metal to be welded not exc. 6.0mm, complete all as specified and as directed. |
| 53 | S&F Corrugated Mild Steel Sheeting 0.63mm thick, Galvanised @120 Gram Per Sqm, with Two Corrugation Side Lap, fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed. |
| 54 | M&L Re-fixing Corrugated Mild Steel Sheeting of any thickness (except Sheets, Serviceable Sheet obtained from BOQ Item No. 1.11 here-in-before) with Two Corrugation Side Lap, fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed. |
| 55 | S&F Plain Mild Steel Sheeting 0.80mm thick, Galvanised @ 120 Gram Per Sqm, in Ridges, Hips, Valley Gutters, etc., fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed. |
| 56 | M&L Re-fixing Plain Mild Steel Sheeting of any thickness (except Sheets, Serviceable Sheet obtained from BOQ Item No. 1.11 here-in-before) in Ridges, Hips, Valley Gutters, etc., fixing with and including L-type or J-type Cranked Hook Bolts with Washer, etc., complete all as specified and as directed. |
| 57 | S&F Pre-painted (Green Colour) Galvalume Aluminum Zinc Coating GI based Corrugated Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed. |
| 58 | M&L Refixing Pre-painted Galvalume Corrugated Steel Sheet (Serviceable Pre-painted Galvalume Corrugated Steel Sheet obtained from BOQ Item No. 1.11 here-in-before) in Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed. |
| 59 | S&F Pre-painted (Green Colour) Galvalume Aluminum Zinc Coating GI based Plain Steel Sheet 0.50mm thick Coloured, having Tensile Strength of 550 Mpa in Ridges/Roof Covering, Cladding to Walls, fixed with Aluminum Self Tapping Screws and Aluminum Washers of suitable Size, complete all as specified and as directed. |
| 60 | M&L Exposed Suspended False Ceiling System having Snap Grid/ Frame Work of size 605x605mm, all as per Specification and Drawing of MES Schedule (except Hangers), complete all as specified and as directed. |
| 61 | S&F Hangers 4.0mm dia GI (upto 1200mm length) for adjusting Level, fixed to Roof Slabs by means of Ceilling Cleats made out of GI Flat 40x3.0mm in size, 60mm long and Expansion Hold Fasteners 12.5mm dia, 40mm long, complete all as specified and as directed. |
| 62 | S&F HSPC Non-Asbestos Fibre Cement Building Boards 4.0mm thick of Size 600x600mm or Size as ordered, fixing with Mild Steel Screws to Timber Frame Work in Ceiling, Flat or Sloping as in Walls, etc., complete all as specified and as directed. |
| 63 | S&F Plywood Board 6.0mm thick, Grade BWP, Type BB, fixing with Mild Steel Screws to Timber Frame Work in Ceiling, Flat or Sloping as in Walls, etc., complete all as specified and as directed. |
| 64 | S&F Plywood Board 6.0mm thick, Grade BWP, Type BB, fixing with Mild Steel Screws to Timber Frame Work in Wall Panelling, etc., complete all as specified and as directed. |
| 65 | M&L Roughening Surfaces of Old Concrete Floor by Picking, Sweeping Clean and Washing down with Water to remove Dust, etc. and Brushing Neat Cement Slurry with 3.0 Kg of Cement Per Squre Metre, complete all as specified and as directed. |
| 66 | M&L Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Square/ Rect-angular), Area of Each Tile exc. 0.18 Sqm but not exc. 0.38 Sqm (1st quality as approved) in Floors, Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to include in the Quoted Unit Rate. |
| 67 | M&L Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Square/ Rect-angular), Area of Each Tile exc. 0.18 Sqm but not exc. 0.38 Sqm (1st quality as approved) in Vertical Surfaces i.e. Dado, Skirting, etc., Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to include in the Quoted Unit Rate. |
| 68 | M&L Glazed Ceramic Coloured Tiles 350x250x7.0mm/ 450x350x7.0mm thick (1st quality as approved) in Vertical Surfaces i.e. Dado, Skirting, etc., Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to include in the Quoted Unit Rate. |
| 69 | M&L Machine Cut Granite (of any type) Work 20mm thick (Table Rubbed and Polished) in Steps, Jambs, Pillars, Window Cills, Cooking Platforms and like in Cement Mortar 1:4 including Pointing in White Cement 1:2, using Marble Dust with Admixture of Pigment to match with Shade of Granite, fixing over and including Cement Screed Bed 15mm thick in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to include in the Quoted Unit Rate. |
| 70 | M&L Machine Cut Kota Stone Slab 18-22mm thick in Flooring, etc., laid over 20mm thick Screed base in Cement Mortar 1:6, laid and joined with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including necessary Cutting, Rubbing and Polishing, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to include in the Quoted Unit Rate. |
| 71 | M&L Machine Cut Kota Stone Slab 18-22mm thick in Riser of Steps, Skirting, Dado and Pillars, laid over 15mm thick Screed base in Cement Mortar 1:4, laid and joined with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including necessary Cutting, Rubbing and Polishing, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to include in the Quoted Unit Rate. |
| 72 | M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) 75mm thick in Plinth Protection, etc., Laid in Alternate Panels, finished Concrete Surfaces Even and Smoooth without using Extra Cement, complete all as specified and as directed. |
| 73 | M&L Rendering (Internal) 10mm thick in Cement Mortar 1:6 on Brick/ PCC Blocks or Concrete Works, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 74 | M&L Rendering (External) 15mm thick on Brick/PCC Blocks or Concrete Works consisting in 2 layers, Backing/Under layer of 10mm thick in Cement Mortar 1:4 and Float/ Top layer 5.0mm thick in Cement Mortar 1:4 including mixing WPC to Float/Top layer, finished Fair and Even, complete all as specified and as directed. NOTE : Water Proofing Compound (WPC) will be Measured and Paid separately under appropriate Item. |
| 75 | Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed. |
| 76 | M&L Preparing New Plastered Surfaces of Walls and applying Three Coats of White Wash, complete all as specified and as directed. |
| 77 | M&L Complete Removal of Existing Surface Treatment of Ceiling of any description and applying Three Coats of White Wash, complete all as specified and as directed. |
| 78 | M&L Preparing Newly Plastered Surfaces of Walls and applying Two Coats of Distemper Oil Emulsion (as approved) over a Coat of Chalk Whiting (Priming Coat), complete all as specified and as directed. |
| 79 | M&L Preparing New Plastered Surfaces of Walls and Applying Two Coats of Cement Based Paint (as approved Tint) over a Coat of Alkali Resistant Priming Paint, complete all as specified and as directed. |
| 80 | M&L Complete Removal of Existing Surface Treatment of Walls and Applying Two Coats of Cement Based Paint (as approved Tint) over a Coat of Alkali Resistant Priming Paint, complete all as specified and as directed. |
| 81 | M&L Preparing New Wooden Surfaces of any description, over 10 Cm in Width or Girth and applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Pink Primer, complete all as specified and as directed. |
| 82 | M&L Preparing Old Painted Wooden Surfaces of any description, over 10 Cm in Width or Girth and Applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint), complete all as specified and as directed. |
| 83 | M&L Preparing New Steel and Iron Surfaces of any descriptions, over exc. 10 Cm in Width or Girth and Applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed. |
| 84 | M&L Preparing Old Treated Steel and Iron Surfaces of any descriptions, over exc 10 Cm in Width or Girth and Applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint), complete all as specified and as directed. |
| 85 | M&L Preparing Old Painted Brick, Stone, Concrete or Plaster Surfaces of Walls and Applying Two Coats of Synthetic Enamel Paint (1st quality/ grade Paint of approved Tint) including Cleaning the Floor/ Joinery Surfaces, Glass Panes, etc., complete all as specified and as directed. |
| 86 | M&L Preparing New or Previously Treated Surface of Wood and Wood based Materials of any description and girth and treated with Two Coats of Creosote Oil, complete all as specified and as directed. |
| 87 | M&L Preparing previously Untreated Surfaces of Wood and Wood Based Materials, of any description and girth not otherwise described and treating with Tar or Coal Tar Black Paint to Backs of Chowkats, etc. Area tarred exc. 0.10 Sqm but not exc. 0.50 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed. |
| 88 | M&L Preparing previously Untreated Surfaces of any description and girth not otherwise described and treating with Tar or Coal Tar Black Paint to Holdfast or similar Small Items, Area tarred not exc. 0.10 Sqm Each including Sanding with Clean Sharp Sand after tarred, complete all as specified and as directed. |
| 89 | S&F Galvanised Steel Tubing 15mm bore (dia), Medium grade, conforming to IS-1239 with all Connections/ Fittings, fixed to Walls, Ceiling or laid in Floors including Taking up or down GI Tubing with Connections/ Fittings, complete all as specified and as directed. |
| 90 | S&F Bib Tap 15mm bore (dia), Cast Copper alloy, Chromium plated, Fancy type with Long Shank and Capstan Heads, screwed down, high pressure, with Crutch or Butter-fly handle, screwed both Ends for Iron Pipe or for Unions and Fixed-in-repairs, complete all as specified and as directed. |
| 91 | S&F Sink without Drainage Board made of Stainless Steel l.0mm thick Kitchen or Laboratory Overall Size 915x460mm having Bowl Size 410x330x160mm with Waste Fitting 40mm dia, Brass Chromium plated, PTMT Waste Pipe 40mm Dia, Strainer, Washers and Wastes Plugs, etc. including Bedding in Cement Mortar to Dwarf Wall or including fixing Cantilever Brackets and connecting Union to Pipe and Fixed-in-repairs, complete all as specified and as directed. |
| 92 | M&L Cast Iron Floor Trap having 75mm dia Outlet with Grating, conforming to IS-3989 including jointing to Waste Pipe and fixing in Cement Concrete 1:2:4 (20mm graded stone aggregates) and Fixed-in-repairs, complete all as specified and as directed. |
| 93 | S&F PVC (SWR) 75mm bore (dia) Pipe, Single Socketed, in any Length with Rubber Ring Joints, laid in Trenches or in Floors including Taking up or down PVC (SWR) Pipe of any descriptions, complete all as specified and as directed. |
| 94 | S&F PVC (SWR) 110mm bore (dia) Pipe, Single Socketed, in any Length with Rubber Ring Joints, laid in Trenches or in Floors including Taking up or down PVC (SWR) Pipe of any descriptions, complete all as specified and as directed. |
| 95 | E/M SERVICES/WORKS |
| 96 | M&L Taking down carefully Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any position including Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets (but excluding Light Fittings of any description), etc, Making Good Disturbed Surfaces of Walls/ Ceillings, etc. in Cement Mortar 1:3 including providing Surface Treatment (Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed. |
| 97 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ FAN/ BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed. |
| 98 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire for ONE 6 AMP 3 PIN SOCKET OUTLET POINT on SAME BOARD, complete all as specified and as directed. |
| 99 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 20/25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 6 AMP, 3/5 PIN SOCKET POINT on INDEPENDENT BOARD, complete all as specified and as directed. |
| 100 | M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Casing Capping (ISI Marked) of suitable size (approx 25/32/40mm width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. complete with PVC Board of suitable size for accommodating Switches, Sockets, Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE 6/16 AMP, 3/5 PIN SOCKET OUTLET POINT on INDEPENDENT BOARD, complete all as specified and all as directed. |
| 101 | S&F Rigid Non-metallic PVC Conduit of size 20mm (External Dia) exclusive of Boxes (Junction/ Terminal) but inclusive of all Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends and Fixing Accessories such as Couplers, Lock Nuts, Saddles, Pipe Hooks, etc. including Taking down/ out unserviceable PVC Conduit Pipe, complete all as specified and as directed. |
| 102 | S&F Rigid Non-metallic PVC Conduit of size 40mm (External Dia) exclusive of Boxes (Junction/ Terminal) but inclusive of all Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends and Fixing Accessories such as Couplers, Lock Nuts, Saddles, Pipe Hooks, etc. including Taking down/ out unserviceable PVC Conduit Pipe, complete all as specified and as directed. |
| 103 | S&F PVC Rectangular Board/Block of size 350x300x50mm Deep, Closed Recessed with 3.0mm thick Plastic Laminated Sheet Cover for mounting Swiches, Sockets, Fan Regulators, etc., complete all as specified and as directed. |
| 104 | S&F Switch Piano 6 Amp, Single Pole, 1-way, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. |
| 105 | S&F Socket Outlet 6 Amp, 5 Pin, Flush type, 230 Volt AC and connecting up, complete all as specified and as directed. |
| 106 | S&F Switch Socket Combination 6/16 Amp, 2-in-1 (3 Pin & 3 Pin), Multi-purpose type, 230 Volt AC and connecting up, complete all as specified and as directed. |
| 107 | S&F Ceiling Rose Surface type, Bakelite 65x50mm, 3 Terminals suitable for 230 Volt AC, 6 Amp and connecting up, complete all as specified and as directed. |
| 108 | S&F Ceiling Fan Regulator 230 Volt AC, Rotary Stepped Electronic type 120/280 Volt and connecting up, complete all as specified and as directed. |
| 109 | S&F Angle Holder PVC/ Polycarbonate type with Back Plate suitable for Batten Fitting and connecting up, complete all as specified and as directed. |
| 110 | S&F LED Bulk Head Light Fitting 10 Watt, Enviroment Friendly, Ultra Modern, Energy Saving, Surface Mounted comprising of High Brightness LEDs and Connecting up with and including suitable size Twisted Flexible Copper Conductor Cable, complete all as specified and as directed.MAKE : BAJAJ/ CG/ C&S HAVELLS/ PHILIPS (as approved by GE). |
| 111 | S&F LED Tube Light Fitting 1x20 Watt, T-08 with 20 Watt LED Tube Rod and Driver having Aluminium Extrution Housing, complete with all Accessories, Pre-wired and connecting up with suitable size Twin Core Twisted Flexible Copper Conductor Cable of size 40/0.0076 and 2 No. PVC Box including Taking down/out Unserviceable Light Fitting, complete all as specified and as directed.MAKE : HAVELLS, Cat No. LHEXBXPNIN1W020 or equivalent Model in Make : BAJAJ/ CG/ C&S/ PHILIPS (as approved by GE) |
| 112 | M&L Taking down Ceiling Fan/ Exhaust Fan of any Make/Model/Sweep from any Height after disconnecting Electric Connection and Keep in Safe Custody for Re-hanging/ Re-fixing, complete all as specified and as directed. |
| 113 | M&L Transporting Ceiling Fan 1200mm Sweep from the Site of Work at ALONG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (not less than 350 Gram) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 114 | M&L Transporting Exhaust Fan 450mm Sweep from the Site of Work at ALONG to nearest Workshop, Removing burnt Winding of any type, Cleaning Slot, Rewinding Fan Motor with Super Enamalled Copper insulated Wire of suitable Gauge and Weight (not less than 350 Gram) providing necessary Insulation Materials, Varnishing, Heating, Reassembling & Testing for Smooth Functioning after Rewinding, Removing the Fan to Site of Work after Rewinding, complete all as specified and as directed. |
| 115 | M&L Preparing old Painted Surfaces of Ceiling Fan of any Sweep including Cleaning, Washing, Rubbing and Filling Cavities with Filler, applying One Coat of Synthetic Enamelled Paint (as approved) with Spray Painting Machine and Writing MES No. with Black Paint, complete all as specified and as directed. |
| 116 | M&L Mild Steel Bands, Straps, Supports or Stays for Rainwater, Ventilating Pipes including Bolts, Hooks (Stay) for large Gates; Fan Hook and Pintle Hinges: large Hasps and Staples; Hand Made Sliding Bolts; Clamps; Holdfasts; Wall Ties and similar small Articles conforming to Fe-290 Gde-E-165, complete all as specified and as as directed. |
| 117 | M&L Re-hanging/Re-fixing only Ceiling Fan (obtained from BOQ Item No. 2.17 here-in-before after Repaired and Painting) and connecting with and including suitable size Copper Conductor Cable from Ceiling Rose to Connector of the Fan, complete all as specified and as directed. |
| 118 | S&F Exhaust Fan 450mm Sweep with Louver Shutter, Single Phase, 230/240 Volt with Fixing Arrangement using Fastener, Providing Electric Connection from Ceiling Rose to Exhaust Fan with and including Copper Conductor Cable of suitable Size and Length, 3 Core, complete all as specified and as directed. |
| 119 | S&F MCB Single Pole 6 Amp to 32 Amp, \"C\" Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out Unserviceable MCB of any description, complete all as specified and as directed. |
| 120 | S&F MCB Single Pole & Neutral 40 Amp, \"C\" Series, 50 Hz, 10 kA, 240 Volt and connecting up including Taking down/out Unserviceable MCB of any description, complete all as specified and as directed. |
| 121 | S&F RCBOs 32 Amp, 32 mA, Double Pole for Earth Leakage, Overload and Short Circuit Protection and connecting up including Taking down/out Unserviceable RCBOs of any description, complete all as specified and as directed. |
| 122 | S&F MCB Distribution Board Sheet Metal Enclosure, SPN, 8-way, 240 Volt AC, Double Doors, with Steel Phosphotised Powder painted, having 200 Amp rated Neutral Bars & Earth Bar and connecting up including Taking down/out unserviceable MCB DB of any description, complete all as specified and as directed.MAKE : HAVELLS, Cat No. DHDPSHOSRW08 or equivalent Model in Make : LEGRAND/ L&T/ SCHNEIDER (as approved by GE) |
| 123 | Supply & Laying or Passing through Pipe 1100 Volt grade heavy duty, Cross-sectional Area 10 Sqmm, 2 Core, Flat or Circular Cable with PVC insulated Aluminium Conductor served with an Inner Sheathing of PVC Tape armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed in Service Connection suspended by insulating Hangers not more than 1.0 Metre apart including 4.0mm Suspension Wire including Taking down/ out Unserviceable Service Connection of any description, complete all as specified and as directed. |
| 124 | Excavating in Trenches, not exc. 1.50 Metre Wide and not exc. 1.50 Metre in Depth for laying of Water Pipe Line, Cable Line, etc., Forming surfaces to required Foundation/ Gradient and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 125 | Removal Excavated Materials (Soil) to a distance not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point, complete all as specified and as directed. |
| 126 | Supply & Laying LT Under Ground Cable 1100 Volt grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded Aluminium Conductor all as per IS:7098 (Part-I)-1998, Cross-sectional Area 10 Sqmm, 2 Core, laid in Trenches, Ducts or through Pipes or fixing to Poles, etc. including Taking down/ out Unserviceable Cable of any description, complete all as specified and as directed.NOTE : Necessary Earth Works, Sand Cushioning, Cable Protection Cover & Pipe, etc. will be Measured and Paid separately under relevent Items. |
| 127 | Supply & Laying HDPE Double Wall Corrugated (DWC) High Density Polythene Pipes of Outer Dia 40mm & Inner Dia 32mm, having corrugation on the Outer Wall and Plain surface on the Inner Wall, conforming to IS:14930 (Part I & II), cut to length as per Site Requirements for protection of UG Cable/ in PCC including cutting Floors, etc. and Making Good the Same with Original Specification to match the existing adjoining Surfaces, etc., complete all as specified and as directed. NOTE : Quoted Unit Rate is inclussive of All accessories for fixing of DWC Pipe with Walls, Roofs, Cable Tray, etc. |
| 128 | M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connectedto Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/ out Unserviceable Earthing of any description, complete all as specified and as directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail