Bids Are Invited For Street Light Pole - Fabricating, Supplying And Erection Of 9Mtrs Long Hot Dip Galvanized Octagonal Pole With Bsen 10025 Grade S 355 Jo Steel Plate For Shaft, Is 2062 For Base Plate With Door Opening Arrangements, Including Suitable-Karnataka

Urban Development Department-UDD has published Bids Are Invited For Street Light Pole - Fabricating, Supplying And Erection Of 9Mtrs Long Hot Dip Galvanized Octagonal Pole With Bsen 10025 Grade S 355 Jo Steel Plate For Shaft, Is 2062 For Base Plate With Door Opening Arrangements, Including Suitable. Submission Date for this Tender is 04-10-2021. Retaining Hardware Tenders in Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

29336103
Bids Are Invited For Street Light Pole - Fabricating, Supplying And Erection Of 9Mtrs Long Hot Dip Galvanized Octagonal Pole With Bsen 10025 Grade S 355 Jo Steel Plate For Shaft, Is 2062 For Base Plate With Door Opening Arrangements, Including Suitable
Open Tender
Indian
Karnataka
04-10-2021

Tender Details

Bids Are Invited For Street Light Pole - Fabricating, Supplying And Erection Of 9Mtrs Long Hot Dip Galvanized Octagonal Pole With Bsen 10025 Grade S 355 Jo Steel Plate For Shaft, Is 2062 For Base Plate With Door Opening Arrangements, Including Suitable Boards, Bakelite Sheet And Mcbs As Per Is Specifications Suitable To Withstand The Wind Speed Of 47 M / Sec For …….Mtrs Pole In Single Section And Single Joint Welded As Per Is 9595 / Is10178aws Having Dimensions Bottom …..Mm, Top….Mm With 3Mm Thick, Suitable Base Plate And 4Nos Of ..... Long J Bolts Along With Template And The Pole Shall Be Hot Dip Galvanized In Single Dipping With Not Less Than 65Micron As Per Astm-A123 And 153 Etc., ( Excluding Foundation ) As Per Drawing Appended.9 Meters - Top 70Mm And Bottom 155Mm Dia Dsr Pwd 2019-20 Pg No. 13 Itno. 4.2.7 , Led Street Light - Supply Of Led Streetlight Luminaire With Pressure Die Cast Aluminium Housing Body For Optimal Thermal Dissipation. Lamp Compartment Comprising Of Anti Glare Clear Diffuser With Injection Moulded Polycarbonate Material, Delivering Superior Light Output. Rated Life Burning Hrs 50000 Hr @Lumen Maintenance Of 70%, Maximum Light Intensity Shouldbe Between 60 Degrees To 70 Degrees. Cct > 5500K, Ip66 Optical And Electrical Compartment & Impact Resistance Of Complete Luminaire > Ik08. Power Factor >0.9 With Mains, Surge Protection- Min 5Kv Along With Over Voltage / Overload, Short Circuit / Miss-Wiring Protection. Compatible For Pole Mouting With Outer Dia Of 40Mm To 50Mm. Universal Voltage Driver To Operate Wide Voltage Range From 100V To 270V 50 / 60Hz Application. Compliance To Is 10322 / Iec60598, Lm 79 & Lm 80 Adherence With Rohs. Ul Approved Mcpcb. Top Access Street Light With Single Screw To Ensure Ease Of Maintenance At The Sight Site Location With Minimizedminimal Tools. Led Light Fixture With ........W System Power Consumption. Led Efficiency>130Lm / W, Nominal Cri >75. Luminaire Manufacturer Should Have In-House Facility Accredited By Nabl / Cpri & Any Government Certified Agency & Design & Development Facility Certified By Iso9001:2008 . Housing With Supplier Word Mark / Name Shall Be Engraved / Embossing On The Die Cast Housing / Body Part. Warranty Of 2 Years Against Any Manufacturing Defect Working Under Standard Electrical Conditions As Mentioned Above Should Be Given By Led Manufacturer & Cree / Nichia / Lumileds / Osram Make Led Source. Led Streetlight 150 Watts Dsr Pwd 2019-20 Pg No. 67 Itno. 12.8.6 , Supplying, And Fixing Of Hot Dip Galvanized M.S.Bracket - Supplying, And Fixing Of Hot Dip Galvanized M.S.Bracketsuitable For Out Door Luminaries And Mounted On Octagonal Pole Using Necessary Bolts, Nuts Etc., Complete. Single Arm Bracket With 1500Mm Standard 40 / 50Mm Dia Dsr Pwd 2019-20 Pg No. 16 Itno. 4.7.2 , Fixing Halogen / Metal Halide / Svl / Il / Led Floodlight Fitting Over Existing Pole / - Fixing Halogen / Metal Halide / Svl / Il / Led Floodlight Fitting Over Existing Pole / Wall Ceiling Including Clamps, Bolts, Nuts And Wiring Using Suitable Capacity Wires. Dsr Pwd 2019-20 Pg No. 79 Itno. 14.5 , Supply And Installation / Fixing / Provision Of Pole Boxwith Hrc Fuse / - Supply And Installation / Fixing / Provision Of Pole Boxwith Hrc Fuse / Mcb Provision And Suitable Connector / Terminal For 3 Ph / 1 Ph Connections With Loop-In & Loop-Out Terminals For 10 Sqmm / 25 Sqmm 3.5 C Al / Ar / Cu / Ar Cable And Branch Out 2.5 Sqmm 2 Core Al / Cu Pvcinsulated Cable, Enclosed In A Thermoplastic, Polystyreneenclosure, Which Should Be Shock Proof, Safe, Ip65 ( Weatherproof ) , Rust Proof, Dust Proof, Water Proof Having Internallyembedded Gasket With Provision For Cable Entry Throughip65 Thermoplastic, Polyamide Glands And / Or Grommets. 200Mmx200mmx98mmdsr Pwd 2019-20 Pg No. 31 Itno. 5.43.1 , Fabricating Supplying And Mounting Ms Box - Fabricating Supplying And Mounting Ms Box Made Out … Swg Suitable For Floor / Wall Mounting, Fully Weather Proof With Provision For Better Heat Dissipation, Provided With Hinged Front Cover, Equipped With Tamper Proof Locking Arrangements, With Suitable Size Clamps With Necessary Cable Entry Pipe With Gland And Box Should Be Finished With 7Tanks Treatment With Powder Coated Paint And Finally Finished With Approved Colour Etc., Complete. 14Swg Dsr Pwd 2019-20 Pg No. 30 Itno. 5.42.1 , Supplying And Fixing Angle Iron Frame Work Fabricated Out Of M.S. - Supplying And Fixing Angle Iron Frame Work Fabricated Out Of M.S. Angle Iron.. And M.S. Flat … With Bolts, Washers Etc., And Painted With 2 Coats Of Red Oxide And Then Two Coats Of Approved Paint. 50X50x6mmdsr Pwd 2019-20 Pg No. 30 Itno. 5.41.2 , Supplying, Fixing And Wiring 0 To 100Amps Direct Reading Ac Analog Type Ammeter - Supplying, Fixing And Wiring 0 To 100Amps Direct Reading Ac Analog Type Ammeter Dsr Pwd 2019-20 Pg No. 29 Itno. 5.25 , Supplying, Fixing And Wiring 0 To 30Amps Direct Reading Ac Analog Type Ammete - Supplying, Fixing And Wiring 0 To 30Amps Direct Reading Ac Analog Type Ammeter Dsr Pwd 2019-20 Pg No. 29 Itno. 5.24 , Supplying And Fixing Of Led Type Panel Board Indicatinglamp - Supplying And Fixing Of Led Type Panel Board Indicatinglamp With Required Colour Suitable For 230 / 440V A.C. 50 Hz 12 / 24V D.C. Dsr Pwd 2019-20 Pg No. 29 Itno. 5.38 , Supplying And Running Of Gi / Copper Strips For Groundingconnections - Supplying And Running Of Gi / Copper Strips For Groundingconnections, Using Necessary Fixing Materials As Required. 50X6mm Gi Strip Dsr Pwd 2019-20 Pg No. 40 Itno. 6.4.5 , Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards - Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898. 6-32Amps Spdsr Pwd 2019-20 Pg No. 27 Itno. 5.17.1 , Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Board - Supplying And Fixing Miniature Circuit Breakers On Existing Mcb Distribution Boards Using Necessary Fixing Materials And C Type Curve, Indicator On / Off, Energy Cross-3 With Short Circuit Breaking Capacity Of 10K And Complete Wiring As Required Confirming To Iec 60898. 50-63Amps Tpn Dsr Pwd 2019-20 Pg No. 27 Itno. 5.17.9 , Supplying Of 1.1 Kv Lt Ug Cable Xlpe Or Heat Resistant - Supplying Of 1.1 Kv Lt Ug Cable Xlpe Or Heat Resistantpvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975.4 Core 16 Sqmmdsr Pwd 2019-20 Pg No. 40 Itno. 6.4.4 , Supplying Of 1.1 Kv Lt Ug Cable - Supplying Of 1.1 Kv Lt Ug Cable Xlpe Or Heat Resistant Pvc Insulated, Pvc Extruded Inner Sheath Armoured Ug Lt Cable As Per Is-1554 ( Part-1 ) Or Is-7098 Part-1, Armouring Strip Thickness In Average +5% And Resistivity 14 Ohms / Kms ( Max ) As Per Is-3975.3.5 Core 25 Sqmmdsr Pwd 2019-20 Pg No. 40 Itno. 6.4.5 , Digging Of Trench - Digging Of Trench Of 0.6M Deep X 0.50 Mtr Wide Refilling The Trench To The Required Ground Level And Consolidating Etc., Complete. ( As Per Civil Sr Ksrb I-2, P-7 ) .In Soil ( Hard ) Dsr Pwd 2019-20 Pg No. 40 Itno. 6.4.5 , Labour Charges For Laying Of 1.1 Kv - Labour Charges For Laying Of 1.1 Kv Class Ug Cable In Existing Trench Gi Pipe / Stoneware Pipe / On Wall / On Pole As Required. 25 Sqmm To 75 Sqmmdsr Pwd 2019-20 Pg No. 41 Itno. 6.5.2 , Supplying And Fixing Of Class A ( Medium Duty ) Gi Pipe Of Wall - Supplying And Fixing Of Class A ( Medium Duty ) Gi Pipe Of Wallthickness Not Less Than 3.25Mm On Pole / Wall / Drain Crossing With Necessary Clamping Arrangements For Ug Cable Of 1.1 Kv.65Mm Dsr Pwd 2019-20 Pg No. 42 Itno. 6.9.3 , Wiring For Lighting / Power Circuit - Wiring For Lighting / Power Circuit Using One Of Frls Pvc Insulated 1100V Grade, Multistrand Copper Wire With Low Conductor Resistance Single Core In Open Or Concealed System Of Wiring With Specified Is-694:Confirming To Latest Amendments.2.5 Sqmmdsr Pwd 2019-20 Pg No. 41 Itno. 6.5.2 , Supplying Of Multi Function Digital Meter With Three Line Back - Supplying Of Multi Function Digital Meter With Three Line Backlight Lcd Type Display For Voltage, Current, Frequency, Power, Power Factor, Kva, Kwh, Kvar Suitable For 3Phase, 4 Wire Lt Network With Ip 54 Degree Of Protection Andcompletely Wired As Required With Communication Port Andclass 0.5S Accuracy. Dsr Pwd 2019-20 Pg No. 29 Itno. 5.33 , Supply And Fixing Of 4Pole Power Contactor - Supply And Fixing Of 4Pole Power Contactor With No / Nccontacts On Existing Wood / Panel Board Using Necessarybolts, Nuts, Washers And Wiring Etc., Complete With Ac-3Rating And As Per Is-13947. 60 To 70Amps Dsr Pwd 2019-20 Pg No. 26 Itno. 5.13.3 , Supplying And Fixing Microprocessor Based Astronomical - Supplying And Fixing Microprocessor Based Astronomicaltimer Switch With Using Necessary Bolts, Nuts And Washers.Dsr Pwd 2019-20 Pg No. 32 Itno. 5.48 , Supplying And Fixing Moulded Case Circuit Breaker ( Mccb ) - Supplying And Fixing Moulded Case Circuit Breaker ( Mccb ) Over The Existing Wood / Panel Board Using Necessary Screws, Bolts, Nuts, Necessary Phase Separators, Handle And Wiringcomplete. Protection Of Overload And Short Circuit Withthermal Magnetic / Micro Processor Release And Earth Faultas Per Is-13947. ( Icu = Ics ) 100Amps 25Ka. Dsr Pwd 2019-20 Pg No. 26 Itno. 5.14.7 , Arth Work Excavation For Foundation Of Building Culverts - Ksrb 2.2.1 Earth Work Excavation For Foundation Of Building Culverts Water Supply Sanitaery Lines And Electrical Conduits Either In Pits Or In Trenches 1.5M And Above In Width. In Ordinary Soil Not Exceeding 1.5M In Depth Including Dressing The Bottom And Sides Of Pits And Trenches, Stacking The Excavated Soil Clear From Edges Of Excavation With Lead Up To 50M After Braeking Of Clods Complete As Per Specificatin, Specification ( Pwd Civil Dsr It No. 2.3 Pg. No. 5 ) , Providing And Laying In Position Plain Cement Concerte Of Mix - Ksrb 4.1.3 Providing And Laying In Position Plain Cement Concerte Of Mix 1.4:8 Using 40Mm And Down Size Graded Granite Metal, Machinemixed Machine Mixed Concerte Laid In Layers Not Exceeding 15Cms Thick Wall Compacted In Foundation And Plaint Including Cost Of All Materails Labour. Hom Of Machinery Curing Complete As Per Specifications Kbs 4.1, 4.2 With All Leads And Liftsloading Unloading And Charges Etc. Complete And As Directed By The Engineersin Charge Of Work Dsr Itno 4.3 Pg No. 12 , Providing Tmt Steel Reinforcement For Rcc - Ksrb 4.9.2 Providing Tmt Steel Reinforcement For Rcc Work Including Straightening Culting Bending Hooking Placing In Position Tapping And Or Weilding Wherever Required Tying With Binding Wire And Anchoring To The Adjoining Members Wherever Necessary Completeas Oer Design ( Laps Hooksand Wastageshall Not Be Measuring And Paid Cost Of Materials. Labour Hom Of Machinery Complete As Per Specificationno Kbs 4.6.3 Tmt Bar Fe 500 ( Dsr It No. 4.46.2 Pg No. 17 ) , Providing And Laying In Position Reinforced Cement Concerte - Ksrb 4.2.2: Providing And Laying In Position Reinforced Cement Concerte Of Design Mix M20 With Opc Cement @320Kgs With 20Mm And Down Size Graded Granite Metal Coarse Aggregarte @0.69Cum And Fineaggregates 0.46Cum Withsuoerplaster @31Ls Confirming To Is9103-199 Reafimed -2008, Machine Mixed Concerte Laid In Layers Not Execeeding 1.5Cmsthick Vibrated For All Works In Ground Floor Level For Roof Slabs Staircase Lintels Retaining Wall Return Any Thickness Including Attached Plasters Columns Plers Abutments Pillars Posts Struts Bultresses String Or Lacing Courses Parapets Cills Filters Etc. Including Cost Of All Materials, Labour Hom Of Machinery Curing Complete As Per Specification No Kbs4.1, 4.6 As Directed By The Engineer In Charge Of Work ( Dsr It No. 4.13 Pg No. 14 ) , Roviding And Removing Centring Shultering Proping - Ksrb 4-6.12: Providing And Removing Centring Shultering Proping Etc, And Removal Of Formwork For Foundation, Footing Bases Of Column For Mass Concerte Including Cost Of All Materials, Labour Complete As Per Specification ( Dsr It No. 4.28 Pg No. 15 ) , Supplying Fixing And Wiring Earth Electrode For Grounding Of Lifts - Supplying Fixing And Wiring Earth Electrode For Grounding Of Lifts, Transformers, Dg Sets Etc. Using 40Mm Dia 2.9Mm Thick 2.5 Mtr Long Gi Pipe With Gi Funnel With Mesh And Suitable Size Reducer Fixed On The Top Of The Earth Electrode. The Funnel Should Be Enclosed In A Cc Chamber Of 400X400x400mm With A Cast Iron Cover. The Earth Electrode Shall Have Staggered Holes Of 12Mm Dia And The Electrodeshould Be Covered 150Mm All-Round With Alternate Layers Of Salt And Charcoal From The Bottom Of The Cc Chamber. The Connection From The Electrode Is To Be Established Throughgi Strip Using Gi Bolts And Nuts.Dsr Pwd 2019-20 Pg No. 44 Itno. 6.19.1 Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
INR 10000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Sl. No. Item TitleItem Description
1street light poleFabricating, supplying and erection of 9Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.9 meters - Top 70mm and bottom 155mm dia DSR PWD 2019-20 PG No. 13 ITNO. 4.2.7
2LED STREET LIGHTSupply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>130lm/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. LED Streetlight 150 Watts DSR PWD 2019-20 PG No. 67 ITNO. 12.8.6
3Supplying, and fixing of Hot dip Galvanized M.S.BracketSupplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1500mm Standard 40/50MM dia DSR PWD 2019-20 PG No. 16 ITNO. 4.7.2
4Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole /Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. DSR PWD 2019-20 PG No. 79 ITNO. 14.5
5Supply and Installation / Fixing / Provision of Pole box with HRC Fuse /Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph / 1 Ph connections with Loop-In & Loop- Out terminals for 10 Sqmm / 25 Sqmm 3.5 C Al/Ar / Cu/ Ar Cable and branch out 2.5 Sqmm 2 core Al/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/or grommets. 200mmx200mmx98mmDSR PWD 2019-20 PG No. 31 ITNO. 5.43.1
6Fabricating supplying and mounting MS boxFabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG DSR PWD 2019-20 PG No. 30 ITNO. 5.42.1
7Supplying and fixing angle iron frame work fabricated out of M.S.Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mmDSR PWD 2019-20 PG No. 30 ITNO. 5.41.2
8Supplying, fixing and wiring 0 to 100amps Direct Reading AC analog type AmmeterSupplying, fixing and wiring 0 to 100amps Direct Reading AC analog type Ammeter DSR PWD 2019-20 PG No. 29 ITNO. 5.25
9Supplying, fixing and wiring 0 to 30amps Direct Reading AC analog type AmmeteSupplying, fixing and wiring 0 to 30amps Direct Reading AC analog type Ammeter DSR PWD 2019-20 PG No. 29 ITNO. 5.24
10Supplying and fixing of LED type panel board indicating lampSupplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. DSR PWD 2019-20 PG No. 29 ITNO. 5.38
11Supplying and running of GI/Copper strips for grounding connectionsSupplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 50x6mm GI strip DSR PWD 2019-20 PG No. 40 ITNO. 6.4.5
12Supplying and fixing miniature circuit breakers on existing MCB distribution boardsSupplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and "C" Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SPDSR PWD 2019-20 PG No. 27 ITNO. 5.17.1
13Supplying and fixing miniature circuit breakers on existing MCB distribution boardSupplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and "C" Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN DSR PWD 2019-20 PG No. 27 ITNO. 5.17.9
14Supplying of 1.1 KV LT UG cable XLPE or Heat resistantSupplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975.4 core 16 sqmmDSR PWD 2019-20 PG No. 40 ITNO. 6.4.4
15Supplying of 1.1 KV LT UG cableSupplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975.3.5 core 25 sqmmDSR PWD 2019-20 PG No. 40 ITNO. 6.4.5
16Digging of trenchDigging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7).In soil (hard)DSR PWD 2019-20 PG No. 40 ITNO. 6.4.5
17Labour charges for laying of 1.1 KVLabour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. 25 sqmm to 75 sqmmDSR PWD 2019-20 PG No. 41 ITNO. 6.5.2
18Supplying and fixing of class A (medium duty) GI pipe of wallSupplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.65mm DSR PWD 2019-20 PG No. 42 ITNO. 6.9.3
19Wiring for lighting/power circuITWiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmmDSR PWD 2019-20 PG No. 41 ITNO. 6.5.2
20Supplying of multi function digital meter with three line backSupplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. DSR PWD 2019-20 PG No. 29 ITNO. 5.33
21Supply and fixing of 4pole power contactorSupply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 60 to 70Amps DSR PWD 2019-20 PG No. 26 ITNO. 5.13.3
22Supplying and fixing Microprocessor Based AstronomicalSupplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.DSR PWD 2019-20 PG No. 32 ITNO. 5.48
23Supplying and fixing Moulded Case Circuit Breaker (MCCB)Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100Amps 25kA. DSR PWD 2019-20 PG No. 26 ITNO. 5.14.7
24arth work excavation for foundation of building culvertsKSRB 2.2.1 Earth work excavation for foundation of building culverts water supply sanitaery lines and electrical conduits either in pits or in trenches 1.5M and above in width. In ordinary soil not exceeding 1.5M in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead up to 50M after braeking of clods complete as per specificatin, Specification (PWD CIVIL DSR it no. 2.3 pg. No. 5)
25Providing and laying in position plain cement concerte of mixKSRB 4.1.3 Providing and laying in position plain cement concerte of mix 1.4:8 using 40mm and down size graded granite metal, machinemixed machine mixed concerte laid in layers not exceeding 15cms thick wall compacted in foundation and plaint including cost of all materails labour. HOM of machinery curing complete as per specifications KBS 4.1, 4.2 with all leads and liftsloading unloading and charges etc. complete and as directed by the engineersin charge of work DSR itno 4.3 pg no. 12
26Providing TMT steel reinforcement for RCCKSRB 4.9.2 Providing TMT steel reinforcement for RCC work including straightening culting bending hooking placing in position tapping and or weilding wherever required tying with binding wire and anchoring to the adjoining members wherever necessary completeas oer design(Laps hooksand wastageshall not be measuring and paid cost of materials. Labour HOM of machinery complete as per specificationNo KBS 4.6.3 TMT bar FE 500 (DSR it no. 4.46.2 pg no. 17)
27Providing and laying in position reinforced cement concertEKSRB 4.2.2: Providing and laying in position reinforced cement concerte of design mix M20 with OPC cement @320kgs with 20mm and down size graded granite metal coarse aggregarte @0.69cum and fineaggregates 0.46cum withsuoerplaster @31ls confirming to IS9103-199 Reafimed -2008, machine mixed concerte laid in layers not execeeding 1.5cmsthick vibrated for all works in ground floor level for roof slabs staircase lintels retaining wall return any thickness including attached plasters columns plers abutments pillars posts struts bultresses string or lacing courses parapets cills filters etc. including cost of all materials, labour HOM of machinery curing complete as per specification No KBS4.1, 4.6 as directed by the engineer in charge of work (DSR it no. 4.13 pg no. 14)
28roviding and removing centring shultering propingKSRB 4-6.12: Providing and removing centring shultering proping etc, and removal of formwork for foundation, footing bases of column for mass concerte including cost of all materials, labour complete as per specification (DSR it no. 4.28 pg no. 15)
29Supplying fixing and wiring earth electrode for grounding of liftsSupplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established throughGI strip using GI bolts and nuts.DSR PWD 2019-20 PG No. 44 ITNO. 6.19.1