Military Engineer Services-MES has published Special Repairs To Roof Sheets Of Bldg No.Et-09, Et-11 And Other Special Repair Works Under Ge Saugor Special Repairs To Roof Sheets Of Bldg No.Et-09, Et-11 And Other Special Repair Works Under Ge Saugor. Submission Date for this Tender is 13-11-2021. Shed Construction Tenders in Saugor Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 08-Oct-2021 | DATES AMDT | Date | 18-10-2021 |
2 | 11-Oct-2021 | amddts date | Date | 25-10-2021 |
3 | 25-Oct-2021 | amddts dates | Date | 30-10-2021 |
4 | 30-Oct-2021 | amds date | Date | 03-11-2021 |
5 | 02-Nov-2021 | Dates corrigendum | Date | 06-11-2021 |
6 | 02-Nov-2021 | amendments | Other | 06-11-2021 |
7 | 06-Nov-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-11-2021 |
Sl. No. | Item Description |
1 | Dismantling unframed timber scantlings 40 sqcm & over in section, in any position complete all as specified and directed |
2 | S&F 0.50 mm thick galvalume sheet profile pattern precoated coloured having tensile strength 550 Mpa as in roof covering, fixed with self driving screws including dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. Make:-Durashine manufactured by Tata BlueScope Steel/JSW Colouron+ or equivalent make as approved by GE |
3 | S&F 0.50 mm thick galvalumesheetprecoated coloured profile ridge ,fixed with self driving screws including dismantlingAC sheet ridge/hip for corrugated or semi corrugated sheets from roof and taking down carefulycomplete all as specified and directed. Make:-Durashine manufactured by Tata BlueScope Steel/JSW Colouron+ or equivalent make as approved by GE |
4 | S&F structural steel work as in tubular trusses including special shaped washercomplete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed. |
5 | S&F structural steel work as inroof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc complete all as specified and directed. |
6 | S&F mild steel for wind ties for roof including securing bolts, postsincluding all necessary drilling, bolting or riveting, etc & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed |
7 | S&F MS plates (plain or chequered) channels square cut to or notched forming holes with riveted bolted or welded attachment conforming to Fe-410W complete all as specified and directed. |
8 | S&F mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 22.5cm & not exc 30cm long, dia of shank 16 to 20 mm complete all as specified and directed. |
9 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed. |
10 | M&L for brickwork with subclass "B"bricks, straright or curved on plan exc 6m mean radius built in cement mortar 1:6 including demolition of brick work with all quoins arches , pillars etc built in cement mortar complete all as specified and directed. |
11 | M&L for plain cement concrete 1:2:4, type B-1 ( using 20 mm graded stone aggregates) as in coping, apex stone, bed plate, kerbs including weathering , slightly rounded or chamferred angles and throating and including necessary form workcomplete all as specified and directed |
12 | M&L for plain cement concrete 1:4:8, type D2 (using 40mm graded stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed |
13 | M&L for rendering 15 mm thick on brick wall/concrete surfacesin CM (1:6) surface finished even & smooth without using extra cement complete all as specified and directed. |
14 | M&L for applying three coats of white wash on new wall surfaces including preparation of surfaces complete all as specified and directed. |
15 | Supply, installation, testing and commissioning of outdoor type 126 KVAR rated Automatic power factor correction (APFC)capacitor bank suitable for 415V, 3phase 50Hz with 10 steps of 12 stage APFC relay for MPP-H capacitors of (1x1,2x1,3x1,5x1,10x1,15x1,20x2,25x2)KVAR and housed in highly functional enclosure of size not less than 1100x1000x300mm made from 3.15mm thick CRCA sheet dust & vermin proof of IP-64 protection, with anticorrosive coating and finally powder coated Panel with front opening shutters with suitable angle iron stand complete copper busbar 160Amps and panel wiring with FRLS cable comprising of the following:- |
16 | (a) 12 stage APFC relay 3-CT NAAC 3P-12,- 01 No (b) CT-200/5 - 01 No (c) MCCB TP DN2 160Amps. DN2 160M - 01 No (d) Spreader link set 160Amps - 01 No (e) MCB TP 63 Amps - 04 Nos (f) MCB TP 32 Amps - 06 Nos (g) MCB SP 6 Amps - 04 Nos (h) MCB SP 2 Amps - 10 Nos (j) Contactor MNX25 - 04 Nos (k) Contactor MOC 10KVAR - 01 No, 15KVAR - 01 No, 20 KVAR - 02 No and 25KVAR - 02 Nos (l) Capacitor Heavy duty 25 KVAR - 02 No, 20 KVAR - 02 Nos, 15 KVAR - 01 No, 10 KVAR - 01 No, 5 KVAR - 01 No, 3 KVAR - 01 No, 2 KVAR - 01 No and 1 KVAR - 01 No (m) Schezler switch - 08 Nos (n) LED Indicator lamp - 08 Nos (o) Panel cooling fan 8.5 inch - 01 No |
17 | Supply, installation, testing and commissioning of outdoor type 101 KVAR rated Automatic power factor correction (APFC)capacitor bank suitable for 415V, 3 phase 50Hz with 08 steps of 8 stage APFC relay for MPP-H capacitors of (1x1,2x1,3x1,5x1,10x1,15x1,20x2,25x1)KVAR and housed in highly functional enclosure of size not less than 1000x800x300mm made from 3.15mm thickCRCA sheet dust & vermin proof of IP-64 protection, with anticorrosive coating and finally powder coated Panel with front opening shutters with suitable angle iron stand complete copper busbar 160Amps and panel wiring with FRLS cable comprising of the following:- |
18 | (a) 8 stage APFC relay 3-CT NAAC 3P-8- 01 No (b) CT-200/5 - 01 No (c) MCCB TP DN2 160Amps. DN2 160M - 01 No (d) Spreader link set 160Amps - 01 No (e) MCB TP 63 Amps - 03 Nos (f) MCB TP 32 Amps - 06 Nos (g) MCB SP 6 Amps - 04 Nos (h) MCB SP 2 Amps - 08 Nos (j) Contactor MNX25 - 04 Nos (k) Contactor 10KVAR - 01 Nos, 15KVAR - 01 No and 25KVAR - 03 Nos (l) Capacitor Heavy duty 25 KVAR - 01 No, 20 KVAR - 02 Nos, 15 KVAR - 01 No, 10 KVAR - 01 No, 5 KVAR - 01 No, 3 KVAR - 01 No, 2 KVAR - 01 No and 1 KVAR - 01 No (m) Schezler switch - 08 Nos (n) LED Indicator lamp - 08 Nos (o) Panel cooling fan 8.5 inch - 01 No |
19 | Supply, installation, testing and commissioning of LT panel outdoor type floor mounted made out of 3.15 mm thick CRCA sheet dust & vermin proof of IP-64 protection, duly powder coated and pre wired as per standard engineering practice the panel manufacture should have got any of his earlier panel tested at CPRI for short circuit current of 50 KA for one second and similar design and tecnology shall be adopted for fabrication of panel totally enclosed with front opening shutters and proper locking arrengement, 60cm long legs made out of 40X40X6mm MS angle grouting in PCC 1:2:4 including necessary earth work comprising of the following:- (a) MCCB with fixed thermal and fixed magnatic type of capacity 315 Amps, 4pole, 415 Volts, 36 KA-01 No (incoming) (b) - do -butMCCB of 160 Amps, 4pole, 415 Volts, 25 KA - 01 No (outgoing) (c)- do - but MCCB of 100 Amps, 4pole, 415 Volts, 16 KA - 02 No (outgoing) (d) MCB TPN 63 Amps 4 pole 415 volts 10KA - 02 (outgoing) (e) Digital voltage, Current, frequency, powe factor, power & energy meters-01 No (f) Blank space to accommadate the MCCB upto rating 200 Amps-1 No (g) Aluminium bus bar four strip of rating 800 Amps -01 Set (h) Digital indicator Lamp (RYB) -01 Set |
20 | All as per Srl item No,3 above but comprising of the following:- (a) MCCB with fixed thermal and fixed magnatic type of capacity 400 Amps, 4pole, 415 Volts, 35 KA-01 No (incoming) (b)- do - but MCCB 200 Amps, 4pole, 415 Volts, 36 KA-01 No (outgoing) (c)- do - but MCCB 160 Amps, 4pole, 415 Volts, 16 KA-02 No (outgoing) (d)- do - but MCCB 63 Amps, 4pole, 415 Volts, 16 KA-01 No (outgoing) (e) Digital voltage, Current, frequency, powe factor, power & energy meters-01 No (f)Blank space to accommadate the MCCB upto rating 200 Amps-1 No (g) Aluminium bus bar four strip of rating 800 Amps -01 Set (h) Indicator Lamp (RYB) -01 Set |
21 | M&L for earthing complete with galvanised steel earthplate electrode 600X600X6 mm thick, burried directly in ground,earth pit not less than 2.25 metre deep below ground level with top edge of earth plate not less than 1.5 metre below ground level, steel earth plate connected with 25 x 4 mm GI strip by means of bolts, nuts, check nuts and washer of galvanised iron or steel as shown in electrical plate No. 5 connected to earth test point all as described in MES schedule part II including excavation earth work concreate pit with 50 mm thick RCC cover in RCC 1:2:4 type B-I duly reinforced with MS bars 6 mm dia @ 150 C/C both ways and pit chamber in PCC 1:2:4 type B-I with 2 Nos suitable lifting handles of 12 mm MS bar and GI protection pipe of suitable size,and watering pipe 20 mm dia with water funnel test point and extra length up to 7.5 meter connected to Panelboardcompleteall as specified |
22 | Supply and laying, testing and commissioning of LT cable XLPE insulated screened and PVC bedded galvanised steel strip or conductor 1.1KV grade cross sectional area 300 sq mm 3.5 core laid in trenches/duct/floor or on pole or through pipe all as specified and directed. |
23 | All as per Srl item No.20 above but 240 Sqmm 3.5 core |
24 | All as per Srl item No.20 above but 150 Sqmm 3.5 core |
25 | Excavation in trenches in hard/ dence soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation, etc., and getting outcomplete all as specified and directed |
26 | Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed |
27 | Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtrs above the starting point complete all as specified and directed |
28 | M&L for sand cushioning with a layer of sand 80mm thickbefore laying of cable and 150mm thick after laying of cable in trenches complete all as specified and directed. Note:-Punned thickness shall be measured and paid |
29 | Supplying and laying bricks, sub class"B" laid dry in trenches over the cable adjoining each other widthwise for cable protection complete all as specified anddirected |
30 | Supplying, laying and fixing in position galvanized iron pipe 80mm bore light grade fixed to pole with mild steel clamps of required size or laid through wall/under floor/under road/in trenches complete all as specified and directed. |
31 | All as per Srl item No. 28 above but 100mm bore -ditto- |