8250 Repairs To Galvalume Sheet, Ac Sheet / Manglore Tile, Eves Board False Ceiling And Certain Misc Items In The Area Of Age B / R-Ii Under Ge ( Central ) Pune 8250 Repairs To Galvalume Sheet, Ac Sheet / Manglore Tile, Eves Board False Ceiling And , GE (Central) Pune-Maharashtra

Military Engineer Services-MES has published 8250 Repairs To Galvalume Sheet, Ac Sheet / Manglore Tile, Eves Board False Ceiling And Certain Misc Items In The Area Of Age B / R-Ii Under Ge ( Central ) Pune 8250 Repairs To Galvalume Sheet, Ac Sheet / Manglore Tile, Eves Board False Ceiling And . Submission Date for this Tender is 19-10-2021. Shed Construction Tenders in GE (Central) Pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

29291027
Corrigendum : 8250 Repairs To Galvalume Sheet, Ac Sheet / Manglore Tile, Eves Board False Ceiling And Certain Misc Items In The Area Of Age B / R-Ii Under Ge ( Central ) Pune 8250 Repairs To Galvalume Sheet, Ac Sheet / Manglore Tile, Eves Board False Ceiling And
Open Tender
Indian
Maharashtra
GE (Central) Pune
19-10-2021

Tender Details

8250 Repairs To Galvalume Sheet, Ac Sheet / Manglore Tile, Eves Board False Ceiling And Certain Misc Items In The Area Of Age B / R-Ii Under Ge ( Central ) Pune 8250 Repairs To Galvalume Sheet, Ac Sheet / Manglore Tile, Eves Board False Ceiling And Certain Misc Items In The Area Of Age B / R-Ii Under Ge ( Central ) Pune

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Oct-2021 Corrigendum No 01 BOQ 12-10-2021
2 12-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
INR 20 Lakhs /-

BOQ Items

Name of Work: Repair toto galvalume sheet AC Sheet /Manglore tile, eves board false ceilling and certain misc items in the area of AGE B/R-II under GE (C) Pune
Sl. No. Item Description
1Demolition of cementconcrete in ground floor and paving not exc. 15 mm thick (below or above ground level) and removing rubbish off the premises complete all as specified and directed.
2Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facingsdressed sttone work and precast PCC Block and removing rubbish off the premises complete all as specified and directed.
3Taking down cementplaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and removing rubbish off the premises complete all as specified and directed
4Dismantling asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings complete including removing u/s materials off the premises all as specified and directed
5Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete including removing u/s materials off the premises all as specified and directed
6Dismantaling Single layer Mangalore pattern or similar tiles in roofing complete including removing u/s materials off the premises all as specified and directed.
7All as per item No 6 here-in-before but embeded in cement mortar.
8Dismantling Battens for tiles, shingles etc, of any size of spaced exc 15 cm including tilting fillets complete including removing u/s materials off the premises all as specified and directed
9Dismantling wrought iron or mild steel work of any description not otherwise provided for complete including removing u/s materials off the premises all as specified and directed
10Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets.complete including removing u/s materials off the premises all as specified and directed
11Dismantling timber scantlings 40 sq. cm and over in section,framed work in any position including removing u/s materials off the premises complete all as specified and directed.
12Taking down chowkats or frames of wooden / steel exc 1.5 sqm but nexc 4.00 sqm (without taking off shutters from the frames) & removing fromsite including making good to disturbed jambs complete all as specified and directed.
13All as per item No 12 here-in-before but not exc 1.5 Sqm each.
14Demolition and breaking up drain pipes (Salt glazed ware, AC, Reinforced concrete or PVC) setin cement mortar complete including removing u/s materials off the premises complete all as specified and directed.
15Taking up or down carefully steel tubing and connections including cleaning for refixing or removal from site completed all as specified.
16(a) 15mm bore
17(b)20mm bore
18M&L for plain cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate in mass concretecomplete all as specified and directed
19M&L for PCC solid block masonary exceeding 10 Cms in width with solid blocks of PCC (1:5:8) grade D5 and setting in CM(1:6).complete all as specified and directed
20Cutting holes in stone / brick walls built in cement mortar for inserting hold fastsmeasured from face of jambsinto wall exc. one brick but n. exc.two bricks &making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and directed
21Cutting chases, pinning in making good to facings where required and pointingin CM 1:4 for consealed water tubing on wall exc 10 cm but n exc 20 cm width etc complete all as specified and directed
22S&F 2 nd class Hard wood weather boarding clean sawn, thickness 20mm to 25 mm and rebated on thick edge to give 20mm laps complete all as specified and directed
23M & L 2nd Class hardwood Clean sawn battens at30 cm centres sectional area exc 15 & nexc 25 Sqmcomplete all as specified and directed
24Fixing only Clean sawn Batten at 30 cm center of any sectional area complete all as specified and directed
25M&LRoof trusses (framed), trussed purlins, rails, fastenings and heavy bracket framing including distance pieces, cleats etc Fe-410-W (Gde E-250) Quality A complete all as specified and directed
26M& L Stairs(framed) including stringers, treades, landing, balusters, hand rails including cleats, brackets, etc. complete all as specified and directed
27S&F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /clading to wall fixed withself taping screws complete all as specified and directed
28S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /clading to wall/eaves board fixed withself taping screws complete all as specified and directed
29S& F6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc Fixed with L-type or J-type or cranked hook bolts complete all as specified and directed
30S& F 6 mm thick Asbestos cement one piece plain angular ridge fixed with L-type or J-type or cranked hook boltscomplete all as specified and directed
31M& L Mild steel sheet 1 mm thick & 150 mm dia for eaves gutters, galvanised class 3, half round with rounded edges complete all as specified and directed
32M& L fibre glass reinforced translucent corrugated sheeting 2 mm thickwith two corrugations side lap in roof/ wall etcfixed with L-type or J-type or cranked hook bolts complete all as specified and directed
33S&F 5 mm thick plain poly carbonate sheet of any size, self coating of any colour and fixed with self tapping screws complete all as specified and directed.
34M & L Roof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed
35Fixing onlyRoof tiles, Mangalore pattern, interlocking at side joints, laid dry complete all as specified and directed
36M & L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6complete all as specified and directed
37Fixing only Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6complete all as specified and directed
38M&L for 8 mm thick one side laminated gypsum ceiling board for false ceiling on and including aluminium powder coated grid work 60 cm x 60 cm with using 36.5 mm x 23.5 mm x1.5 mm thick main tee, 23.5 x 23.5 mm x 1.28 cross tee and 25 x 25x 1.5 mm angles fixed to perimeter of wall for false ceiling including necessary supporting hanger with 4.0 mm dia GI wire and "J" bolts washer nuts for securing frame work to ceiling suspended @ 120 cm C/C both ways, size of grid shall be 605 x 605 mm, complete all as directed and specified
39M & L Seamless calcium silicate 12mm thk ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finishincluding necessary supporting hanger with 4.0 mm dia GI wire and "J" bolts washer nuts for securing frame work toGl frame work for (605 mm x 605 mm) seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl thin layer of putty with gypsum binder, sanding the sufrace till smooth surface is obtained and applyingtwo coats of oil bound distemper over acoat of prime rcomplete all as specified.
40S&F aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat etc complete all as specified and directed
41S&F powder coated aluminium door shutters (single / double leaf) not less that or partitions comprising of aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed.
42S&F powder coated window and ventilator shutters in three track sliding (whichever the case may be ordered to sliding horizontally or vertically) with two or more shutters with sliding arrangement rubber beading and glazing clips using aluminium sections weighing not less than 0.55 Kg/M etc complete all as specified and directed
43S&F powder coated venitlator with louvers with partially guaged shutter using 5 mm thick x 10 cm wide frostedglass strips with rubber beading and glazing clips etc using aluminium sections weighing not less than 0.55 Kg/M complete all as specified and as directed
44S&F in repair aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed
45Supply and fix stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with aluminium wire staples complete all as specified.
46M&L for 10mm thick cement plaster in CM 1:6 on brick surface finished even and smooth without using extra cement. complete all as specified and directed
47M & L Dubbing out average 15mm thick on irregular face of walls in CM 1:6 complete all as specified and directed
48M&L for 15mm thick cement plaster in cm 1:4 on concrete surfaces and finished with sponge finish complete all as specified and directed
49M&L for Preparing newly plastered surfaces and applying two coats of oil bound distemper on walls complete all as specified and directed
50M&L forpreparaing newplastered surfaces of wall and applying two coats ofcementbase paintcomplete all as specified and directed
51M&L for two coats of syntheticenamel paint on new wooden surface over one coat of pink primer including preparation of new wooden surfaces complete all as specified and directed
52M&L for preparation of new surface of steel of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
53M & L preparing surfaces of wood or wood based material new or old of any description or girth andtreating end of post, back of chowkats etc with tar or coal tar black paint.complete all as specified and directed
54M&L for preparation of old plastered surfacesof wall and applying two coatsof cement base paintcomplete all as specified and directed.
55M&L for preparing Old plastered surfaces and applying two coats of oil bound distemper on walls complete all as specified and directed.
56Supply and fixing 4 mm thickfrosted glass selected quality for glazing and fixed to aluminium window / ventilator shutters / steel windows etc all as specified and directed
57S&F GI tubing "medium grade" galvanized with all fittings and fixed complete to walls and ceiling or laid in floors etc complete all as specified and directed.
58(a) 15mm bore
59(b) 20mm bore
60Refixing old steel tubing and connections in new or old postion (wall/floor/ceilings etc) of following size complete.
61(a) 15mm bore
62(b)20mm bore
63S&F110 mm bore PVC SWR pipessingle socketed inany length withrubber ring joints fixed to walls, floors etc complete all as specified and directed
64All as per item No 57 here-in-before but 75 mm bore.
65S&F75 mm bore PVC SWR pipes single socketed in any length with rubber ring jointslaid in trenches or in floors including clamp etc complete all as specified and directed
66S&F PVC (SWR) bendswith oval access door of 110 mm borecomplete all as specified and directed
67All as per item No 60 here-in-before but 75 mm bore.
68S&F PVC SWR Branch piece single(Single Y) equal or unequal 110mm bore with door access.complete all as specified and directed
69All as per item No 62 here-in-before but 75 mm bore.
70S&F PVC 110 mm bore SWR junction (single "T") equal or unequal with door access. complete all as specified and directed
71All as per item No 64 here-in-before but 75 mm bore.
72S&F 110 mm bore PVC SWRvent cowl complete all as specified and directed.
73All as per item No 66 here-in-before but 75 mm bore.
74S&F gun metal globe or gate valves with iron wheel head, screwed boh ends foriron pipe and fixed 20mm bore ISI marked complete all as specified and directed
75S&F 500 lit capacity Rotational moulded polyethylene water storage tanks double layered ISI marked (cylindrical vertical with closed top) hoisted and fixed in position with and including 20 mm bore ball brass valve with polythene float and flynut all as specified and directed including dismantling old u/s tank complete.
76All as per item No 69 here-in-before but 1000 litre capacity.