Construction Of 3Rd Kot Moka Boundary Wall Between Various Barracks In Distt. Jail Faridabad Construction Of 3Rd Kot Moka Boundary Wall Between Various Barracks In Distt. Jail Faridabad, Faridabad-Haryana

Haryana Police Housing Corporation Limited has published Construction Of 3Rd Kot Moka Boundary Wall Between Various Barracks In Distt. Jail Faridabad Construction Of 3Rd Kot Moka Boundary Wall Between Various Barracks In Distt. Jail Faridabad. Submission Date for this Tender is 04-10-2021. Building Work Tenders in Faridabad Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

29269343
Construction Of 3Rd Kot Moka Boundary Wall Between Various Barracks In Distt. Jail Faridabad Construction Of 3Rd Kot Moka Boundary Wall Between Various Barracks In Distt. Jail Faridabad
Open Tender
Indian
Haryana
Faridabad
04-10-2021

Tender Details

Construction Of 3Rd Kot Moka Boundary Wall Between Various Barracks In Distt. Jail Faridabad Construction Of 3Rd Kot Moka Boundary Wall Between Various Barracks In Distt. Jail Faridabad

Key Value

Document Fees
INR 5000 /-
EMD
INR 49000.0 /-
Tender Value
INR 49.08 Lakhs /-

BOQ Items

Name of Work: Construction of 3rd Kot Moka Boundary wall between various barracks in Distt. Jail Faridabad
Sl. No. Item Description
1HSR Civil
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. HSR/2021/4.14
34.14.1All kinds of soil.
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level:HSR/2021/ 6.1
56.1.6 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-III) : 8 graded cum stone aggregate 40 mm nominal size)
6Providing and laying damp-proof course with cement concrete 1: 1.5:3 (1 cement : 1.5 coarse sand (zone-Ill): 3 graded stone aggregate 20mm nominal size)HSR/2021/6.9
76.9.2 40 mm thick
812 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded: HSR/2021/ 6.11
96.11.2Horizontal
10Reinforced cement concrete work in beams, suspended floors,roofs having slope up to 15° landings, balconies, shelves,chajjas, lintels, bands, plain window sills,ases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size).HSR/2021/6.16
11Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: HSR/2021/7.21
127.21.1 Cement mortar 1:4 (1 cement: 4 coarse sand)
13Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : HSR/2021/7.22
147.22.1 Cement mortar 1:4 (1 cement: 4 coarse sand)
15Extra for making tapered surface of brick masonry .HSR/ 2021 /7.59
16Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proporation of 1:4 (1 cement : 4 graded coarse sand with polymer minimum 2% by st. of cement used ) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation in completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30N/Sqmm2). HSR 26.32.1 12 mm average thickness
1712 mm thick polymer plaster HSR 31.7
18Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. HSR/2021/11.60
19Applying one coat of water thinnable cement primer of approved brand andmanufacture on wall surface : HSR/2021/11.67
2011.67.1Water thinnable cement primer
21Finishing walls with Acrylic Smooth exterior paint of required shade :HSR/2021/11.95
2211.95.1 New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
23Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. HSR/2021/13.29
2413.29.2In gratings, frames, guard bar, ladder, railings,brackets, gates and similar works
25Total Civil HSR
26E.I Work
27COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) as per HSR 23.3
2823.3.6) Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.
2923.3.6.1)1 run of Size 1.50 Sqmm(1/1.40mm)
3023.3.6.3)1 run of Size 4 Sqmm(1/2.24mm)
31Supply and Fixing 3 mm thick Bakelite sheet cover on existing MS/PVC junction box/tee etc including fixing with brass screws and washers. as per HSR 23.8.12
32MCCB ,DISTRIBUTION BOARDS, MCB"s, RCCB"s, CHANGE OVER etc. as per HSR 23.22
3323.22.5) Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:-
3423.22.5.1) 6 amp. to 32 amp Single Pole
3523.22.5.4) 40 amp to 63 amp. Double pole
36EARTHING AND LIGHTENING ARRESTOR as per HSR 24.1
3724.1.1) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required.
3824.1.2) Extra for using salt and char coal/coke for pipe earth electrode as required.
3924.1.7) Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.
40Laying of underground cable in pipe /existing open/closed trench etc asper HSR 24.2.4
4124.2.4.2) 16 Sq mm to 35 sqmm 2 to 4 Core
42Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work .asper HSR 24.2.8
4324.2.8.4) 16 sqmm
44S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.asper HSR 24.5.2
4524.5.2.3) DWC/HDPE pipe 63/50 mm outer dialinner dia
46TOTAL E.I. (HSR)
47E.I. (N.S.) PART
48S/E PVC pipe ISI Marked heavy guage i/c bend inspection box etc., i/c laying of pipe in slab or wall complete with all patty material required to complete the job in all respect .
49iii) 32mm dia recessed
50S/E of hot press moulded SMC junction box (Sintex, Hansel, Somshiva) with hinged cover on existing pole/wall complete with clamps, nuts & bolts, DIN channel for erection of SPMCB/TPNMCB and copper terminal block for 3 phase 4 wire system including labour, petty material and making necessary connections etc but excluding cost of MCB.
51(i) Size 250 mm x 200 mm x 100 mm (inside) & 295 mm x 255 mm x 120 mm (outside)
52S/E of 50/53/60 watt LED Flood Light pressure die casthousingwith IP-65 Protection and efficient LED output for better distribution to be mount on existing building/ terrace complete in all respect.suitable for operation on 230 volts A.C supply(Havell"s -Model-LHEPBFUEIN6W050 or equivalent model of Bajaj/Crompton Greaves/WIPRO/GE/ Philips/HPL)
53S/E PVC insulated 3 core, 1.50 sqmm copper conductor cable(unarmoured), 1100V, grade in existing pipe/pole, complete with all labour and petty material required i/c making necesary connections.
54S/E of 180/200 watt LED Flood Light luminairewith IP-66 Protection and made in pressure die cast and heat shrink aluminium extrusion with high power LEDs as light sourceto be mount on existing building/ terrace complete in all respect.suitable for operation on 230 volts A.C supply
55Supply of U/G Cableincluding making necessary connection with respect to entire satisfactionof Engineer-In-Charge
56i) 16 Sqmm 2 Core ( Unarmoured)
57Total EI NS