| 1 | Surface dressing n exc15 cm deep in soft/loose soil complete all as specified and as directed. |
| 2 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 3 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.hard/dense soil |
| 4 | Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed. |
| 5 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 6 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 7 | M&L for hardcore with broken stone or boulder of gauge not exc 63 mm, deposited , spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surfaces complete all as specified and as directed. |
| 8 | M&L for PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete etc. complete all as specified and as directed. |
| 9 | M & L for PCC 1:3:6, type C2(using 40 mm gradedstone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed. |
| 10 | M&L for 100 mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 11 | M & L for PCC 1:3:6,type C2(using 40 mm graded stone aggregate) as in surface channel or drain including necessary form work complete all as specified and as directed. |
| 12 | M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smoothwithout using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic jointfilling at every 3m length and at corners complete all as specified and as directed. |
| 13 | M&L for 40mm thick PCC 1:2:4,type B1 (using 20mm graded stone aggregate) as in floor, finished the surface even and smooth with using extra cement complete all as specified and as directed. |
| 14 | M & L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in benching and coping, cills, hold fasts, fixing of post, water trough etc. includingnecessary formwork (straight or curved) complete all as specified and as directed. |
| 15 | M & L for forming contraction (dummy) joints 65mm deep x10mm wide, filled with sealing compound Grade \"A\" complete all as specified and as directed. |
| 16 | M&L for RCC1:1.5:3, type A-1 (using 20mm graded stone aggregates) as in foundations, footings, foundation beams, plinth beams, bases for columns, etc. complete all as specified and as directed. |
| 17 | M&L for RCC type1:1.5:3, type A-1 (using 20mm graded stone aggregate) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelvesetc. complete all as specified and as directed. |
| 18 | M&L for RCC type1:1.5:3, type A-1 (using 20mm graded stone aggregate) as in Chajjas complete all as specified and as directed. |
| 19 | Use and waste formwork to sides of concrete foundations, footing, bases of columns, plinth beams for rough finished surfaces of concrete complete all as specified and as directed. |
| 20 | Use and waste formwork to soffits of suspended slab such as roof slabs floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) in rough finished flat surfaces of concrete complete all as specified and as directed. |
| 21 | Use and waste formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressumers, lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams etc. in rough finished flat surfaces of concrete complete all as specified and as directed. |
| 22 | M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cutting, bending cranking, hooking end and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed |
| 23 | M & L for mild steelTMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed. |
| 24 | M&L for mild steel TMT bars 8 mm dia and over upto and including 10mm diacut to length, bent to shape required including cutting, cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and as directed. |
| 25 | M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 26 | M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 27 | M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound (@ 3% by weight of cement or as per manufacture\"s instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note :Water proofing compoundwill be measured and paid separately as \"Supply only\". |
| 28 | M&L for rendering 5 mm thick in cement mortar (1:3) as in ceiling surface finished even and smooth without using extra cement complete all as specified and directed |
| 29 | Supply only integral water proofing compound of approved make complete all as specified and as directed. |
| 30 | M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat ofprimer complete all as specified and as directed. |
| 31 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed. |
| 32 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and as directed. |
| 33 | M&L for Pre-Cast Plain Cement Concrete(1:3:6) type C1 using 20mm graded stone aggregate as in bond stone set in Cement Mortar 1:6complete all as specified and as directed. |
| 34 | M&L For extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling,using 20mm thick Granite or Trap stone complete all as specified and as directed. |
| 35 | M&L for raised pointing to random or ploygonal rubble, uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and as directed. |
| 36 | S&F for (SWR) pipes,75mm bore single socket in any length with rubber ring joint, weep hole etc complete all as specified and as directed. |
| 37 | M&L for hand packing any thickness of broken stone or boulder at back of wall pitching, laid dry, hand packed tightly complete all as specified and as directed. |
| 38 | M & L for 2nd class hard wood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinnedat joints complete all as specified and as directed. |
| 39 | S&F 30mm thick2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed. |
| 40 | M&L formild steel flat iron in bands, straps, supports or stays for pintle hinge, hand made sliding bolts, hold fast etc conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 41 | M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 42 | S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed. |
| 43 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 44 | S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. |
| 45 | S & F 250 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded sectionor cast aluminum alloy complete all as specified and as directed. |
| 46 | S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor complete all as specified and directed. |
| 47 | S&Fsteel ventilators with top hung shutter including hinges, steel peg stay complete including making good disturbed portion in PCC (1:2:4) type B-1 complete all as specified andas directed. |
| 48 | M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces,hold fast etc, complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to Fe 410-W(Gde-E- 250)quality-Acompleteall as specified and as directed. |
| 49 | S&F rolled mild steel plates (plain or chequered) channels. square cut or notched (ordinary & counter sunk) forming holes, with riveted, bolted or welded attachment grade Fe-410-W(Gde-E-250) quality-Acomplete all as specified and as directed. |
| 50 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and as directed. |
| 51 | S & F 4mm thick figured glass, pin head type and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed. |
| 52 | M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base, laid and jointed with grey cement slurry and pointed in white cementmixed with pigment to match the shade of the slab, including rubbing and polishing over and including 20 mm thick screed in cement mortar 1:6 complete all as specified and as directed. |
| 53 | M & L Point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS -694marked, with multi stranded copper conductors and earthcontinuity wire with 1.5 Sqmm cable (including connecting to earth dolly)laid/fixed in stove enamelled steel conduit concealed type on walls/ceiling including sunk type pressed steel terminal box for One light/fan/exhaust fan point controlled by one number one wayswitch including taking down old point wiring complete all as directed. |
| 54 | M&L for switch flame proof rotary type with terminal box in LM6 ,16A single pole 250V complete all as specified and as directed . |
| 55 | S&F flame proof LED tube light fitting 1x 20W including lamp, CMRI certified,IP65 protectionwith all accessories including connectingwith three core flexible copper conductor cable complete all as specified and as directed. Make : Phillips/ Crompton or Bajaj. |
| 56 | S&F Environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagonal bulk head black-lit LED10 W -IP-66 luminaire comprising of high brightness LEDs complete all as specified and as directed.Make:- HavellsModel HEXAFT10WLED857SSYMBOPC or equivalentModel of make : Philips /Crompton /GE. |
| 57 | S & Fsheet metal enclosurewhen MCBto be used 2 way, Single pole & neutralwithout bus barcomplete all as specified and asdirected. |
| 58 | S&F MCBs, SPN 6 to 32 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T |
| 59 | M & L for Lighting conductor of Air terminal , single pointed ,copper rod 12mmdia and 300 mm long completed all as specified and as directed. |
| 60 | M & L for test point teminal block made of gun metal or phosphorus bronze size 75x75x25 mm ,drilled and screwed including 3 nos 8 mm 25 mm long hexgonal Head screw completed all as specified and as directed. |
| 61 | M & L for Copper strip 20 x 3.15mm to be fix on top of\"V\" type porcelain insulator or DMC insulator of suitable sizeand fixing screws etc. for roof conductors and down conductors above ground completeall as specified and as directed. |
| 62 | M&L for earthing complete withcopper earth plate electrode 60cm x 60cm x 3.15 mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with the top edge not less than 1.5 mtr below ground level connected to copperstrip 20 X 3mm as earth lead by means of bolts, nuts, check nuts and washers of steel and other end connected to earthing test point including funnel, watering pipe of 40 mm bore, light grade GI pipe, wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre-cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 10 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in soft/loose soil, disposal of soil not exc. 50 meter complete and testing on completion all as shown in electrical plate No-3 of MES schedule, part-I complete all as specified and as directed.NOTES 1). The unit rate includecopper strip from top of earth plate upto 7.5 meter above ground level. |