| 1 | BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation, pressure rating for chilled / hot water circulation as specified.250 mm dia with cast iron body, nitrille,Hand wheel & working pressure-20 kg with all complete set. |
| 2 | BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation, pressure rating for chilled / hot water circulation as specified.200 mm dia with cast iron body, nitrille,Hand wheel & working pressure-20 kg with all complete set. |
| 3 | BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation, pressure rating for chilled / hot water circulation as specified. 150 mm dia with cast iron body, nitrille,Hand wheel & working pressure-20 kg with all complete set. |
| 4 | BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation, pressure rating for chilled / hot water circulation as specified.125 mm dia with cast iron body, nitrille,Hand wheel & working pressure-20 kg with all complete set. |
| 5 | BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation, pressure rating for chilled / hot water circulation as specified. 100 mm dia with cast iron body, nitrille,Hand wheel & working pressure-20 kg with all complete set. |
| 6 | BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation, pressure rating for chilled / hot water circulation as specified.80mm dia with cast iron body, nitrille,Hand wheel & working pressure-20 kg with all complete set. |
| 7 | Supply, Installation ,testing & commissioning of Hot air exhaust system (IPD building) in case of fire with complete as per tender specification.Supply,installation ,testing & commissioning of Axial fan(2000 cfm) Class-H as per specification..(phase 3,hp -2,pole -2 ) |
| 8 | Supply, Installation ,testing & commissioning of Hot air exhaust system (IPD building) in case of fire with complete as per tender specification.Supply,installation ,testing & commissioning of Axial fan(2000 cfm) Class-F as per specification/ Approved make/ .(phase 3,hp -2,pole -2 ) |
| 9 | Supply,installation ,testing & commissioning of starter pannel including control cable for axial fan as per specification./ as per Approved make |
| 10 | Supply & laying of Copper flexible Power Cable Starter to Fan motor (3 corex2.5 Sqmm) as per approved make ,FRLX cable |
| 11 | Supply, installation, balancing and commissioning offabricated at siteGSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 0.63 MM (24 gauge) Galvanized Sheet Steel Ducting/ as site requirement /(450*450mm) |
| 12 | supply , installation,testingand commissioning of GI volume controlduct Dampercomplete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. GI volume control duct damper/ as per site requirement( size 450*450mm) |
| 13 | Supply & fixing of Canvas Connection ( Fire Proof)/ as per site requirement |
| 14 | Supply & fixing of Canvas Connection ( Fire Redardant) /As per site requirement |
| 15 | Supply& laying ofFresh Air Louver as per specification./as per site requirement /(450*450mm) |