| Sl. No. | Item Description |
| 1 | BOQ UPLOADED ON 15 SEP 2021 |
| 2 | SCH \"A\" PART-I (CIVIL WORKS) |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for and taken on credit complete all as specified and as directed. |
| 4 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings/cladding including ridges, hips, valleys and flashings and taken on credit complete all as specified and as directed. |
| 5 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards / slabs / blankets, any thickness, including cover fillets and and taken on credit complete all as specified and as directed. |
| 6 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 150mm thickness (below or above ground level) and and removal of unserviceable debris to outside of MD land complete all as specified and as directed. |
| 7 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as requiredto facilitate demolition) andremoval of unserviceable debris to a distance not exceeding 100m complete all as specified and as directed. |
| 8 | Demolition of brickwork or stone boulder masonry, built in cement mortar, including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles and removal of unserviceable debris to a distance not exceeding 100m complete all as specified and as directed. |
| 9 | Demolition of stone slabs /tiles of any description or thickness in floors or vertical surfaces, as in ceramic tileslaid, bedded and pointed in any mortar including bedding screed and backing in vertical surfaces and removal of unserviceable debris to outside of MD land complete all as specified and as directed. |
| 10 | Taking up or down steel tubing and connections, including cleaning for refixing or removal from site under Sch of credit of bore of pipe 15mm complete all as specified and as directed. |
| 11 | Taking up or down steel tubing and connections, including cleaning for refixing or removal from site under Sch of credit of bore of pipe 20mm complete all as specified and as directed. |
| 12 | Taking down chowkats or frames(wooden / steel) with shutters(without taking off shutters from the frames) exceeding 1.50 sqm butnot exceeding 4.00 sqmeach and removing from site under Sch of credit complete all as specified and as directed. |
| 13 | Taking down chowkats or frames (wooden / steel) with shutters(without taking off shutters from the frames) not exceeding 1.50 sqmeach and removing from site under Sch of creditcomplete all as specified and as directed. |
| 14 | Taking down cement plaster any description on brick or stone walls, concrete surfaces, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc. andremoval of unserviceable debris to outside of MD land complete all as specified and as directed. |
| 15 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks, etc including cleaning for refixing or removal to store (measured overall as fixed along centre line over fittings and accessories) complete all as specified and as directed. |
| 16 | Plain cement concrete, type B1, 1:2:4, using 20mm gradedstone aggregate as in copings, bed blocks andthe like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and as directed. |
| 17 | Pre-castreinforced cement concrete, 1:2:4, type B1, using 20mm graded stone aggregate as in shelves withplainfairfaces, includingchamfers, weatherings, throating etc., and settingin cementmortar(1:6)complete withjointsto match complete allas specified and as directed. |
| 18 | Notes:- |
| 19 | (a)The rate is inclusive of finishing the exposed surfaces as per clause 4.11.16 of MES Schedule Part-I. |
| 20 | (b)Reinforcementshallbe measuredandpaidseparately as applicable. |
| 21 | Supply only Liquid Water proofing compound all as specified and as directed. |
| 22 | Brickwork with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of designation 50 complete all as specified and as directed. |
| 23 | Brickwork with fly ash bricks, old size, of designation 50, straight or curved on plan to any radius in half thick brick walls built in cement mortar 1:4 complete all as specified and as directed. |
| 24 | Forming jambs, etc. to openings inCM 1:4,including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and as directed. |
| 25 | Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, as in IInd class hardwood complete all as specified and as directed. |
| 26 | Factory made glazed and skeleton shutters, of IInd class hardwood, 35mm thickopen rebated and prepared to receive glass, gauze, etc., (without sash bars) edges of framing plain, with plain, chamfered or rounded. mitred and rebated sash bars for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed. |
| 27 | Note:- |
| 28 | Panel inserts, glass or wire cloth as required shall be measured and paid separately. |
| 29 | Plain particle board12mm thick with commercial veneers on both sidesas inserts in partly panelled door shutters complete all as specified and as directed. |
| 30 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, fixed in opening as per relevant drawing in SSR Part-IIcomplete all as specified and as directed. |
| 31 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heatmoulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixed in frames as per relevant drawing in SSR Part-IIcomplete all as specified and as directed. |
| 32 | Factory made plain, framed, panelled shutters (any number of panels), of IInd class hardwood, 35mm thick with panelsof wood particle board with commercial face veneers complete all as specified and as directed. |
| 33 | Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, overall length of cover plate 150mm, including fixing on floor complete all as specified and as directed. |
| 34 | Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 35 | Anodised aluminium snap grid framework of grid size 605mm x 605mm of main and cross tee of size 40mm x 25mmx 1.5mm thick and wall angle size 25mm x 25mm x 1.5mm thick for false ceilingincluding fixing of supporting hangerscomplete all as specified and as directed. |
| 36 | Note:- |
| 37 | The hangers for support of false ceiling shall be measured and paid separately. |
| 38 | Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 39 | Semi-Perforated particle board 12mm thick of size 600mm x 600mm in ceiling fixed with screw as per manufacturers and surface prepared andapplying two coats of synthetic enamel paint over a coat of pink primer including hidden side complete all as specified and as directed. |
| 40 | Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 200mm complete all as specified and as directed. |
| 41 | Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 125mm complete all as specified and as directed. |
| 42 | Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, length of bolt 300mm complete all as specified and as directed. |
| 43 | Butt hinges, extruded aluminium alloy, with galvanised mild steel hinge pin, anodised, type C-21 of size 100mm complete all as specified and as directed. |
| 44 | Aluminium handles, cast type, anodised of size 150mm complete all as specified and as directed. |
| 45 | Aluminium handles, cast type, anodised of size 125mm complete all as specified and as directed. |
| 46 | Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 47 | Mild steel TMT bars 6mm to 8mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed. |
| 48 | Mild steel as window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165complete all as specified and as directed. |
| 49 | Mild steel as in small articles such as hold fast and like conforming to Fe-290 Grade-E-165 complete allas specified and as directed. |
| 50 | Rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces., cleatsetc., ofFe-410-W (Gde E-250 quality A)complete all as specified and as directed. |
| 51 | Anodised aluminium frame for doors, windows, ventilators with one or more rebates including ioining cleat for fixing etc. complete all as specified and as directed. |
| 52 | Anodised aluminium sections as in styles and rails and handle of aluminium door / window shutters, except fixing complete all as specified and as directed. |
| 53 | Note:- |
| 54 | (a) Rubber packing, screws etc. as required shall be measured fixing of shutters. |
| 55 | (b) Glass or wire cloth as required shall be measured and paid separately. |
| 56 | Fixing only aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary ioining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, and provision of anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21, 100mm long (2 Nos.), suitable handle (1 No.) , aluminum tower bolt 125mm (02 Nos) etc., complete all as specified and as directed. |
| 57 | Note:- |
| 58 | (a) All aluminium sections including snap beading, joining cleats, glazing cilps etc. shall be measured under aluminium shutters separately as supply only. |
| 59 | (b) Glass or wire cloth as required shall be measured and paid separately. |
| 60 | (c) The fixtures given are for shutter of approximatesize 0.50m x 1.50m. |
| 61 | Plain cement concrete, 1:5:10, type E2, using 40mm graded stone aggregate, 75mm thick as in sub-base complete all as specified and as directed. |
| 62 | Plain cement concrete as in sub base averaging 25mm thick including making good depressions / undulations,1:2:4, type B0, using 12.50mm graded stone aggregateand finished to receive screed bed complete all as specified and as directed. |
| 63 | Chequered cement concrete tiles with grey cement and pigment of size 200mm x 200mm x 25mm thick set, jointed and pointed in neat cement slurry at the rate of 4.20 kg / sqmin floors laid over cement screed in CM 1:4, 20mm thickcomplete all as specified and as directed. |
| 64 | Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeeding 0.38 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed. |
| 65 | Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeeding 0.38 sqm,, of superior finish, grade B-II (a) quality in vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick to match the floor tiles complete all as specified and as directed. |
| 66 | Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick applied with cement slurry at the rate of 3 kg / sqm complete all as specified and as directed. |
| 67 | Glazed ceramic tiles coloured of size 300mm x 200mm, minimum 7mm thickin vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed. |
| 68 | Rendering 10mm thick in CM(1:6) on other than fair faces of brickwork finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 69 | Rendering 15mm thick in CM(1:4) on fair faces of brickwork or concrete surfaces mixed with liquid water proofing compound finished fair and even complete all as specified and as directed. |
| 70 | Note:- |
| 71 | Supply only liquid water proofing compound shall be measured and paid separately. |
| 72 | Preparing newly plastered surfaces of wall,,applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed |
| 73 | Complete removal of existing treatment from wall surfaces,applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed |
| 74 | Preparing newly plastered surfaces of wall,applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint over wall care putty 3mm thick,complete all as specified and as directed |
| 75 | Complete removal of existing treatment from wall surfaces, applying two coats of distemper oil emulsion white or tinted including in narrow widths, bands, cornices, pilasters etc., over a coat of alkali resistant priming paint over wall care putty 3mm thick,complete all as specified and as directed |
| 76 | Sheet glass, 4mm thick, ordinary quality and glazing with oil putty / snap beading in squarenot exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 77 | Figured glass, pin head type,4mm thick, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 78 | Preparing new surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 79 | Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 80 | Preparing old painted surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 81 | Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in ends of posts, backs of chowkats etc., area exceeding 0.10 sqmbut not exceeding 0.50 sqm each and treated with tar or coal tar black paint and sanding complete allas specified and as directed. |
| 82 | Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in small articles such as stop, covers, gully gratings, hold fasts etc., , area not exceeding 0.10 sqm eachand treated with tar or coal tar black paint and sanding complete allas specified and as directed. |
| 83 | Unplasticised PVC pipes of pressure rating 10 kgf/sqcm laid in trenches of bore of pipe 15mm complete all as specified and as directed. |
| 84 | Unplasticised PVC pipes of pressure rating 10 kgf/sqcm laid in trenches of bore of pipe 20mm complete all as specified and as directed. |
| 85 | Unplasticised PVC pipes of pressure rating 10 kgf/sqcm fixed to walls, ceilings or in floors etc of bore of pipe 15mm complete all as specified and as directed. |
| 86 | Unplasticised PVC pipes of pressure rating 10 kgf/sqcm fixed to walls, ceilings or in floors etc of bore of pipe 20mm complete all as specified and as directed. |
| 87 | Dismantling existing water tanks, exceeding 500 litres and not exceeding 1000 litres, lowering and taken on charge on creditand provision of rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) , three layered hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres complete all as specified and as directed. |
| 88 | Gun metal, globeor gate valves, with iron wheel head screwed both ends for iron pipe and fixed of bore of pipe 20mm as in repairs complete all as specified and as directed. |
| 89 | Ball brass valves, high pressure, with polythene float and flynut complete, screwed both ends for iron pipe or brass ferrule and fixed, of bore of pipe 20mm as in repairs complete all as specified and as directed. |
| 90 | Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed for bore of pipe 15mm (Minimum weight 15mm-90gms) as in repairs complete all as specified and as directed. |
| 91 | Stop valve of PTMT any colour high pressure screwed for iron pipe and fixedfor bore of pipe 15mm (Minimum weight 15mm-90gms)as in repairs complete all as specified and as directed. |
| 92 | Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixedfor bore of pipe 15mm (Minimum weight 15mm-90gms) as in repairs complete all as specified and as directed. |
| 93 | Towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (minimum weight 170 gms) as in repairs complete all as specified and as directed. |
| 94 | Vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) and including fixing of the following components viz. pedestal pan with \"P\" or \"S\" trap, seat and cover for pedestal pan, flushing cistern, brackets, chain and pull or lever handle, flushing pipe including jointing to socket of flushing rim and connecting pipe to union of flushing cistern, inlet and overflow pipe, anti-syphonage pipe or stopper fixed as in repairs complete all as specified and as directed. |
| 95 | Note:- |
| 96 | Flushing cistern, flush pipe, seat cover, P trap, WC connector,as required shall be measured and paid for under supply only separately. |
| 97 | Supply only of plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 98 | Supply only PVC valveless, syphonic action type flushing cistern 10 litres capacity low level, white with inlet, ball valve, float and handle / push button, including brackets complete all as specified and as directed. |
| 99 | Supply only flush pipe of polyethylene of high density, 32mm dia for low level / high levelflushing cistern complete all as specified and as directed. |
| 100 | PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed. |
| 101 | Vitreous china wash basin, white, flat back, size 550mm x 400mm excluding taps, waste fitting, but including brackets and including fixing of the following components viz. pillar taps, waste fittings and union, plugs and chains and connecting upto supply pipes, wastes or traps, screws, plugs, cement mortar and other subsidary materials required for fixing including cutting for and pinning in ends of brackets but exclusive of fixing of supply and waste pipe as in repairs complete all as specified and as directed. |
| 102 | Note:- |
| 103 | (a) Pillar taps and waste fittings as required shall be measured and paid for under supply only separately. |
| 104 | (b) Supply and waste pipes as required shall be measured and paid for separately. |
| 105 | Supply only Pillar taps of PTMT any colour high pressure screwed for iron pipe and fixed of bore of pipe 15mm (Minimum weight 15mm-110gms) complete all as specified and as directed. |
| 106 | Supply only Waste coupling of PTMT (half or full threaded)fixed of bore of pipe 32mm (Minimum weight 32mm-45gms) complete all as specified and as directed. |
| 107 | LDPE pipes, 32mm bore of pipe, of pressure rating 6 kgf/sqcm with polyethylene thread union and check nuts, fixed to walls as in waste pipein wash basin as in repairs complete all as specified and as directed. |
| 108 | Swivel shower of PTMT any colour for fixing with 15mm pipe including fixing to pipe or union as in repairs (Minimum weight 40gms) complete all as specified and as directed. |
| 109 | Bevelled edged looking mirror of select quality glass, size 600mm x 450mm, 6mm thick, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed to walls as in repairs complete all as specified and as directed. |
| 110 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 110mmcomplete all as specified and as directed. |
| 111 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of bore 75mm complete all as specified and as directed. |
| 112 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of bore 110mm complete all as specified and as directed. |
| 113 | PVC (SWR) floor trap, plain with grating of diameter of outlet 75mm including jointing with solvent cement complete all as specified and as directed. |
| 114 | PVC (SWR) bend any radius of bore 110mm complete all as specified and as directed. |
| 115 | PVC (SWR) bend any radius of bore 75mm complete all as specified and as directed. |
| 116 | Repair of crack in walls by cutting \"V\" groove of width ranging from 6mm to 25mm along the crack line manually or by machine cleaning the around and inside the groove to ensure the groove is free of loose particles and dust by using wire brish and water jet, fixing nozzle and repairing using Fosroc Rendroc CS chemical with a proportion of 1 part water and 2.5 to 3.0 parts of Rendroc CS chemical by volume or w/p ratio 0.36 by weight complete all as specified and as directed. |
| 117 | SCH \"A\" PART-II (INTERNAL ELECTRIFICATION) |
| 118 | Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, etc., and separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed. |
| 119 | Taking down carefully unserviceable sub main wiring aluminium conductor cables any number of runs of any cross section complete, including removal of batten / conduitand separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed. |
| 120 | Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathedFRLSH cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 20 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision ofone 1.5 sqmm PVC insulated single core multistranded copper conductor FRLSH green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep,concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., complete all as specified and as directed for one light point controlled by one switch. |
| 121 | Note:- |
| 122 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 123 | All as per BOQ No.99 here-in-before but for one ceiling fan point controlled by one switch and regulator |
| 124 | Note:- |
| 125 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 126 | All as per BOQ No.99 here-in-before but for one exhaust fan point controlled by one switch. |
| 127 | Note:- |
| 128 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 129 | All as per BOQ No.99 here-in-before but for One switch socket outlet point 3 pin 5 Amps on independent board. |
| 130 | Note:- |
| 131 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 132 | All as per BOQ No.99 here-in-before but for One switch socket outlet point 3 pin 5 Amps on same board with other switches. |
| 133 | Note:- |
| 134 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 135 | All as per BOQ No.99 here-in-before but for point wiring with two 4.0 sqmm single core copper conductor multistrandedFRLSH cable and one 4.0 sqmm PVC insulated single coremultistranded cable as earth continuity conductor FRLSH green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed. |
| 136 | Note:- |
| 137 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 138 | Switch piano, flush type single pole, one way, 5 Amps complete all as specified and as directed. |
| 139 | Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps universal type complete all as specified and as directed. |
| 140 | Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal type complete all as specified and as directed. |
| 141 | Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed. |
| 142 | Stepped type electronic fan regulator, 300 W, flush type, including fixing on existing laminated sheet complete as specified and as directed. |
| 143 | LED batten fitting 20/22 W, 230V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed. |
| 144 | Note:- |
| 145 | (a) Makeshall be Havells Cat No. LUMILINEPLUSBS20/22WLED865SPCSS or equivalent of makes as listed here-in-after. |
| 146 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 147 | LED batten fitting 10 W, 230V, extruded aluminium housing provided for easy heat dissipation wall mounted complete pre wired and including tube and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting with the following parameters,complete all as specified and as directed. |
| 148 | Note:- |
| 149 | (a) Makeshall be Havells Cat No. LUMILINEPLUSBS10WLED865SPCSS or equivalent of makes as listed here-in-after. |
| 150 | (b) For all other mandatory requirements of LED fittings, please refer Particular Specifications given here-in-after. |
| 151 | Surface mounted, LED bulk head fitting, 10W with PDC aluminium housing and milky diffuser, 230V, pre wired including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire complete all as specified and as directed. |
| 152 | Note:- |
| 153 | (a) Make shall be C & S Cat No.SIRIUS / 10Wor equivalent of makes as listed here-in-after. |
| 154 | (b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after. |
| 155 | LED building security light fitting 20W made up of powder coated pressure die cast aluminium SMD LED Street light without lens with heat resistant toughened glass., IP66 protection and impact resistance of IK07, complete pre-wired and connecting up with suitable twin core flexble copper wireincluding provision of necessary GI tubing medium grade 25mm bore of pipe 1.5m bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed. |
| 156 | Note:- |
| 157 | (a) Makeshall be as C & S Cat No. INDUS-i/20W under or equivalent of makes as listed here-in-after. |
| 158 | (b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after. |
| 159 | Exhaustfan, heavy duty, 300mm sweep, 1370 RPM, with louvers, metal body conforming to IS-2312-1967, AC singlephase, 240 Volts, 50 Hzand connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copperconductorcablefromceilingroseor connectorto fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed. |
| 160 | Note:- |
| 161 | Make shall be of Usha Cat No. AEROCLEAN PLUS 300MM or equivalent of makes as listed here-in-after. |
| 162 | Taking down ceiling fan any sweep, dismantling and opening up, replacing bearings, bushes, condensors of same existing type and capacity, greasing, assembling back, painting of fans complete,with synthetic enamel paint by spraying including filling cavities with filler, coat after cleaning all dust, dirt, grease, rewinding motor etc., testing and writing MES No.20mm height with synthetic enamel paint black and hanging back in position with all accessories and connecting including 1.5 sqmm flexible three core multistranded copperconductorcablefromceilingroseor connectorto fan including earthingcomplete all as specified and as directed. |
| 163 | MCB 6-32 Amps, SP, 240 Volts, 50 Hz, AC supply, \"B\" curve, with breakingcapacity of 10 kA complete all as specified and as directed. |
| 164 | MCB 40 Amps, SPN, 240 Volts, 50 Hz, AC supply, \"C\" curve with breakingcapacity of 10 kA complete all as specified and as directed. |
| 165 | Sheet metal enclosures with socket plug top and MCBs, single pole and neutral with two pin and earth plug and socket complete one single pole MCB 20 Amps, 10 kA, \"B\" Curve,240 V complete all as specified and as directed. |
| 166 | MCB DB SPN 8 way, doubledoor, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCBdouble pole as incomer and DP / SP MCBs as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. |
| 167 | Note:- |
| 168 | The incomer and outgoing MCBs as required shall be measured and paid separately. |
| 169 | Load line MCB DB TPN 4 way, vertical, doubledoor, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for MCCB FP, 100 Amps as incomer and MCB SP 40 / 63 Amps as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. |
| 170 | Note:- |
| 171 | The incomer and outgoing MCCBs/MCBs as required shall be measured and paid separately. |
| 172 | MCCB Four Pole, 100 Amps, 415 V, 16 kA, with fixed magnetic and fixed thermal setting complete all as specified and as directed. |
| 173 | Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmmFRLSH conforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistrandedcopper conductorcable FRLSH (green) asearth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting tocommon earth dolly complete all as specified and as directed. |
| 174 | Note:- |
| 175 | (a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length. |
| 176 | (b) Cutting chases on walls for concealing pipes and cost of terminal box is deemedto be included in the item rates quoted for sub-main wiring / circuit wiring. |
| 177 | Earth continuity conductor or main earthing lead of 4mm dia GI wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required as in repairs complete allas specified and as directed. |
| 178 | Earthing complete with galvanised iron earth plate electrode 600mm X600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directlyin ground vertically to a depth not lessthan2.25 metres below ground level with top edge of the earth plateat a depth not less than1.5 metres belowgroundlevel, connectedto earth leadasdescribedhere-in-beforebymeansofbolts,nuts, washers and checknuts made out ofgalvanised iron or mild steel, earthingleadprotectedby asdescribedhere-in-beforeand connected to main switch board or main control board or electric poleall asshownonelectricalplate No.3of MES Sch Part-Iincluding necessaryearth work and excavation in any type ofsoil,plain cementconcrete1:3:6,typeC1 chamber,reinforcedcement concretecover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm diaTMT barsat140mmcentreto centrebothways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugsincluding testing complete all as specified and as directed. |