Provn Of Chain Link Fencing ( Hybrid Fencing 93.052 Mtr Long ) With Steel Gate, Piller And Wing Wall At Gate No 02 Of Cetc Doraha And Special Provn Of Chain Link Fencing ( Hybrid Fencing 93.052 Mtr Long ) With Steel Gate, Pille, Doraha and CG Complex under GE Ludhiana-Punjab

Military Engineer Services-MES has published Provn Of Chain Link Fencing ( Hybrid Fencing 93.052 Mtr Long ) With Steel Gate, Piller And Wing Wall At Gate No 02 Of Cetc Doraha And Special Provn Of Chain Link Fencing ( Hybrid Fencing 93.052 Mtr Long ) With Steel Gate, Pille. Submission Date for this Tender is 19-10-2021. Building Repair Tenders in Doraha and CG Complex under GE Ludhiana Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

29203150
Corrigendum : Provn Of Chain Link Fencing ( Hybrid Fencing 93.052 Mtr Long ) With Steel Gate, Piller And Wing Wall At Gate No 02 Of Cetc Doraha And Special Provn Of Chain Link Fencing ( Hybrid Fencing 93.052 Mtr Long ) With Steel Gate, Pille
Open Tender
Indian
Punjab
Doraha and CG Complex under GE Ludhiana
19-10-2021

Tender Details

Provn Of Chain Link Fencing ( Hybrid Fencing 93.052 Mtr Long ) With Steel Gate, Piller And Wing Wall At Gate No 02 Of Cetc Doraha And Special Provn Of Chain Link Fencing ( Hybrid Fencing 93.052 Mtr Long ) With Steel Gate, Piller And Wing Wall At Gate No 02 Of Cetc Doraha And Special Repair To Bldg No P-46 At Cg Complex Under Ge Ludhiana

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Sep-2021 Clarification date Date 12-10-2021
2 29-Sep-2021 BOQ BOQ 12-10-2021
3 12-Oct-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-10-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 31797.0 /-
Tender Value
INR 15.89 Lakhs /-

BOQ Items

Name of Work:Provn of chain link fencing (Hybrid fencing 93.052 Mtr Long) with steel gate, piller and wing wallat Gate No 02 of CETC Dorahaand Special Repair to bldg No P-46 at CG Complex under GE Ludhiana
Sl. No. Item Description
1Sch "A" sec-I
2Excavation in trenches in soft/ loose soil n. exc. 1.5 metre wide for foundations, laying cables and similar works n. exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed.
3M&LPCC (1:4:8) Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified.
4Returning filling in including spreading, levelling, watering and well ramming in layers notexceeding 25cm thick complete all as specified.
5Removing excavated soil to a distance n exc 50 m and depositing where directed not exceeding 1.5 m above the starting point .
6M&L for RCC(1:1 1/2:3) nominal mix using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete.
7M&L for RCC(1:1 1/2:3) nominal mix using 20mm graded stone aggregate as in column peir postand struts.
8Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter.
9Formwork to sides of pillars, posts, struts, piers, columns, and stanchions.
10S&F forMild steel TMTbars 10m dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
11S&Ffor Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
12M&L for brickwork with subclass "B" bricks , straight or curved on plan exc 6 m mean radius .built in cement mortar 1:4.
13M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar (1:4).
14Preparing of new plastered surface of walls and applying two coats cement basepaints on walls.
15S&F for mild steel post and sturts in fencing incl cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets for securing wire mesh incl all necessary, drilling and bolting or revetting and similar work confirming to Fe-290 Gde E-165
16M&L for mild steel bolts screwed on end with hexagonal or square nuts and washers other end 10mm dia of neck and not exc 10cm long
17Fixing only chain link fencing including line wires, any mesh,size and type to to any type of standards rails straining bolts etc including provision of binding wire
18Supply only chain link MS galvanised fencing any size or type as directed by Engr-in-charge.
19S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixed to any type of standard rails, straining bolts, incl securing or tying at crossings with and provn of galvanised mild steel wire, stapler or pins.
20M&L for painting two coats of synthetic enamel paint over a coat of red oxide including preparation of new steel surfaces of any description over 10cm in width or grith not other wise described
21M&L for cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed plates, coping, roof kerbs or mud stops; rounded or chamferred on edges completeall as specified & directed by Engineer-in-Charge.
22S&F for Mild steel framed work as ingate of angle & other sections with gusset plates, wheel track etc complete hooks for steel hanging door fittings also fastening and fixing complete in GDE i.e. Fe 410-W (Gde E-250) quality A.
23M&L for two coats of synthetic enamel paint on one coat of Red oxide primer on newly steel surface over 10 cm in width or girth, complete all as specified & as directed.
24M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) with 12mm thick rendering in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified.
25Demolition of cement concrete (unreinforced) concrete in ground floors and pavingn-exc 15cm thickness ( below or above ground floors.)
26Dismantling floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises .
27M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile 0.11 Sqm but n.exc 0.18 Sqm, in neatcement slurry and pointed in white or coloured cementwith pigment to match over 15mm thick screed bed in cement mortar (1:6) all as specified and directed.
28-ditto- all as per item No 27 but in shirting/doddo laid over 10mm thick cement screed in cm 1:4 complete all as specified
29M&L for 50mm thick cement conc one 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection joint filled with bitumen sand mixer 50mm thick finished even and smooth without using extra cement.
30Hacking out old broken glass (any thickness) , size, quality or description ) frommetal frame including punching or drilling out old glazing pins and providing and fixing new ones.
31S&F for sheet glass ordinary quality and glazing with oil putty in square nexc 0.5 Sqm Each pane 3mm thick.
32-Ditto- all as per item no 31 but 4.8mm thick and area exc. 0.5 Sq.m in each pane.
33Taking down chowkhat or frame with shutter(without taking off shutter from frame) exc 1.5Sqm and nexc 4Sqm.
34-ditto -all as per above but n -exc 1.5 SqmEach.
35Taking down shutters of any description exceeding1Sqm but not exceeding 2 Sqm each.
36Framed work as in doors or gate,coolers standof angle or others section etc confirming to Fe 410-s .
37S&F for pressed steel frames,size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete ,as specified.
38M&L for providing cement concrete type C-0 1:3:6 (12.5 mm graded agg) as for pressed steel chowkhats.
39S&F for plain framed panelled shutter (two planel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of the rail and stile as per IS:1003(Part I), kiln sseasoned and chemically pressure treated 35mm thick.
40M&L, glazed and skeleton shutters open rebated and prepared to receive (glass) gauze (without sash bars) edges of framing plain chamfered or rounted fitted with cut and mitred beads for securing gauze (glass) etc size of members of shutters as specified 35mm thick 2nd classHW.
41S & F forsteel window 1.25 mm thick box type (primer coated) ERW hollow P section of size 60mmx25mm single rebated comprises gauged skelton shutter ERW sec 50mmx20mmand 1mm thick with two openable leaf consisting two Nos sash bars of T-section 20mmx3mm complete welded to frame with one verticle mulion of ERW box type T-section of size 60mmx25mm and 1.25mm thick incl cutting holes and making good dismantled portion PCC (1:2:4) type B-1 four Nos for each window) including following fittings welded to frame shutter: - (a) Hold fast, 150mm long of 12mmx3mm made to shape-04 Nos per window. (b) Handle of z section 20mmx25mm, 100mm long 01 Nos per leaf (c) MS tower bolt 150mm long-2 Nos per leaf (d) z section 20mmx25mm, 100mm long stopper - 01 No per leaf (f) MS pintal hinges of size 75mmx12mm- 2 Nos per leaf (g) Fabrication & fixing arrangement as per Drg No CEJZ/TD-06/07.Note: wire mesh and painting shall be measured & paid separately under appropriate item.
42All as per item No 41 here in before but window with glazed shutters .Note Glass and painted shall be measured and paid separately under appropriateitem.
43S&F for steel windows or steel ventilators fixed type with glazing bar complete
44S&F for mild steel framed work such as grills, framed guard bars, grating and likeconfirming to FE 410 or FE 310
45S&F for glavanised Mild steel wire cloth. 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvnaised wire staples.
46S&F for Aluminium anodised barrel tower bolts of extruded section and fixed 200mm long
47S&F for Aluminium handles cast type anodised 150mm long.
48S&F for mild steel 300mm helical door spring , ordinary rat tail rod patteren including roller and roller plate complete.
49M&L for aluminium alloy anodised sliding door with hasp staple(bolt type) and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolts of extrudedsection or cast aluminium alloy and fixed 250mm long.
50M& L for preparation of new surfaces of wood surface of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamelled paint over one coat of pink primer.
51-do- all as per item no 50 but two coats of synthetic enamelledpaint of new surface of steel.
52S&F for floor doors stoppers of aluminium alloy body and tenque anodisede with hard drawn steel spring fixed in floor 150mm long.
53Taking down curatain rods along with wooden pallmate laid on wall.
54S&F in repair curtain rod made out ofmild steel 25mm dia(outerdia )pipe having thickness 0.63mm , PVC coated and colour/pattern, over all dia 28 to 29 mm complete all as specified and directed, Make :- Aerolux/MEC.
55S&F for plastic finial of 28 to 29mm bore, decorated type, of any colour/pattern, best quality to suit the curtain rod and fixed at the end of curtain rodwith suitable adhesive complete all as specified and directed, Make:- Aerolux/MEC or VISTA
56S&F for mild steel prepainted bracket to hold the curtain rod and fixed to wall(Concrete/brick masonry) with the help of 2 Nos 50mm long steel screws and rawl plug included drilling with electric drill and making good the disturbed surfaces complete all as specified and directed.
57Demolition of cement concrete(unreinforced) of any description and in any position not otherwise specifically provided for.
58Dismantling brick tiles or terracing tiles sinlge layer on roofs.
59Demolition of mud in roofs any thickness including plastering and leeping(whether full thickness removed or only a part there of)
60M&L for wire brushing neat cement slurry with 3kg of cement per sq m at top and bottom of base coat and cleaning top surfaceall as specified
61M &L for PCC 1:2:4 type B-1 as roof padding concrete to bring the existing slab in slope of 1:40. complete all as specified.
62M&L for 15mm thick rendering on terrace, sides of parapet in cement mortar 1:4 with water proofing compound, finished even and fair.(Note water proofing compound will be measured and paid separately under other item.
63Supply only integral water proofing compound.
64M&L for priming surfaces and applying normal treatment (for moderate conditions) using bitumen primer @ .30 Kg/Sqm applied hot
65M&L for providing APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/Sqm ) land on after applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2Kg per Sqmby forced application complete all as specified.
66M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar(1:3) mixed with 5% of crude oil by weight of cement on mud phuska
67-dittio - all as per item No 66but except tiles.
68M&L flush pointing to brick laid flator brick tiles in paving cement mortar in 1:3.
69M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) in roof kerbs or mud stops, benching rounded or chamfered on edges complete.
70Demolition of brick built in cm including all quoins arches pillars etc.
71M&L Brick work with sub class "B" bricks straight or curved in plane exc 6cm mean radius built in cm 1:6.
72Taking down cement plasteron brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc.
73M&L 15mm thick plastering on fair faces of bricks or cone surfaces finished even and smooth w/o using extra cement in cm1:6.
74M&L 5mm thick plastering on fair faces ofr cone surfaces finished even and smooth w/o using extra cement in cm1:3 on ceiling .
75M&L 15mm thick plastering on fair faces of bricks or concrete surfaces finished even and smooth w/o using extra cement in cm1:4.
76M&L Preparing of new surface of plaster and applying three coats of white wash on ceiling.
77M&L for preparing of new plastered surface and applying two coats cement basepaints on walls.
78M&L two coats of Oil bound distemper over a coat of chalk whiting on wall surfaces inclduing prepration of newly plastere surfaces.
79M&L for complete removal of existing treatment and applying two coats of cement base paint of walls.
80M&L for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (plastered or unplastered surfaces) and applying two coats of white (lime) wash complete all as specified and as directed by Engineer-in-Charge.
81Demolition of reinforcement cement concrete as in Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work (reinforcement cut as reqd to facilitate demolition)
82M&L for reinforced Cement Concrete type B1 1:2:4 (nominal mix ) (using 20 mm gradedstone aggregate) in Chajjas etc.
83Use and waste rough finished flat Form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc.
84Dismantling Asbestos cement corrugated sheet in roof covering all as specified.
85S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
86M&L for 40mm thick PCC 1:2:4 (20mm Graded aggregate) as in flooringcomplete all as specified.
87M&L for chequered cement concrete tiles 20cmx 20cmx 25mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 20mm thick screed in cement mortar 1:6
88M & L for 2nd Class hard wood Plain fillets, square, rectangular or triangular in section, clean sawn, secured with mills or brads,
89S&Ffor 18/19mm block boards grade two, interior grade, commercial type and fixed to timber frame work with screws
90S&Ffor anodiesed aluminium frame for doors, windows, ventilators/partition with one or more rebates incl. joining cleat for fixing etc. complete all as specified.
91S&Ffor anodiesed aluminium door shutters, aluminium section weighing 0.55 Kg/m incl. necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each doors, hinges, anodiesed aluminium snap beading screw etc. complete all as specified.
92Dismantling boarding, any description, fixed any position with nails.
93M & L for particle board, 12mm medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber/Aluminium frame workcomplete all as specified.
94Dismantling posts or struts (wood, steel or R.C.C.) any section, including takingout embedded portion and making good disturbed ground.
95Dismantling fencing wire mesh, any type.
96M&L for cement concrete1:3:6 type C2as in foundations, filling and mass concrete .
97S&F for hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0
98S&F for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-0 or Fe 310-0all as specified and as directed by Engr-in-Charge.
99M&L for preparation of new surfaces of steelof any descripltion nexc 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of zink crome primerall as specified and as directed by Engr-in-Charge.
100Taking down carefully point wiring copper/ aluminium (light, fan, socket, power) completeincluding switches, ceiling roses, pendants, regulators , sockets etc and removing materialsto store and making good the disturbed surfacesof walls, floors etc Completeall asspecified & directed by Engineer in Charge.
101Taking down service /sub main wire ofany size fixed in any position , completeall as specified and directed by Engineer in charge.
102M & L for point wiring with PVC (FRLS) unsheathed, fire resistance,stranded copper conductor ofsize 1.5 sqmm (nominal cross sectional area ) single core cable in and including concealed (surface only on roof & colomns) wiring incl PVC conduit medium grade, ISI marked,20 mm or higher dia complete with all accessories/fittings and sunkan MS boxesof thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surfacesheet cover concealed in wall with screws & washers including unsheathed single core PVC (FRLS) insulated cable green in colour1.5 sqmm stranded copper conductoras earth wire and connecting to earth dolly,complete all as specified & directed for the following.
103One light /fan /bell /exhaust fan point controlled by one, one way 5/6 switch.
104One 5 pin 5/6 Amps socket outlet point on independentboard controlledby one, oneway switch single pole 5/6Amps.
105All as per item 104.2 but on the same board with other switches /socket.
106M & L for point wiring with PVC unsheathed, fire resistance, stranded copper conductor ofsize 2.5 sqmm (nominal cross sectional area ) single core cable in and includingrigid non metalic PVC conduit 20 mm dia or higher size "medium " grade ISI marked concealed (surface only on roof & colomns)complete with all accessories/fittings and MS box thickness not less than 1.2 mmcovered with 3 mm thick plastic laminated hard glassy surfacesheet cover concealed in wall with brassscrews & washers including unsheathed single core PVC insulated cable green in colour 2.5sqmm stranded copper conductoras earth wire and connecting to earth dolly, for one three /six pin 15/16 amps power socket controlled by one 15/16 ampsswitch complete all as specified & directed by Engineer in Charge.
107S&F for switch piano flush type white /ivory finish 5/6Amps, single pole one way complete all as specified & directed by Engineer In-charge .
108S&F for switch piano flush type white /ivory finish 15/16 Amps single pole one way-ditto-.
109S &Ffor socket out let2 pin 5/6 Amps & 3 pin 5/6 Amps flush type - ditto-.
110S&F for socket but 3 pin 5/6 Amps & 3 pin 15/16 Amps-ditto-
111S&F for ceiling rose surface Bakelite AC 220/240 volts 3 terminals complete all as specified & directed by Engineer-in-charge.
112Supply and fixing 20 Watt LED lighting fixture (4 Ft) with co extruded polycarbonate body,diffuser,polycarbonate end cover the LED with 120 degree view angle,energy efficient,including rod/tube and connection from ceiling rose to connector complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr in Charge.
113Supply and fix LED security light fittng1x25 watt powder coated pressure die cast aluminium campect for building security purpose with bracket made ofGI pipe medium grade 40mm dia 1.2 mtr long bend to shape as required and fixing with two nos MS clamp of size 40x6mm for fixing of building security light fitting complete all as specified and directed complete all as specified and directed by Engr in Charge.
114S&F forfan regulator , fulsh stapped type ,electronic ,450 watt completeall as specified and directed.
115M & L for submain wiring alongwith earth wire with the 2x6.0 sq. mm +1x4.0 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed as required. Note:- The three RM wire shall be measured in one unit.
116Supply and fixfor single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 to 32 Amps 240 V complete all as specified and directed by Engr in Charge.
117S& F for sheet metal enclosure for DB , 4 way , TPN, with 200 Amps bus bar , 415 Volts suitable for housingMCCBs, isolators and MCBs ,replastring to matchwith existing surface etc complete all as specified & directed by Engineer-In-charge.
118S & F for MCCB of current rating 63 Amps, 4 pole, 415 volts, 50hz, 16 KA rupturing capacityincluding taking down old unsv MCCBs complete all as specified and directed by Engr- in- Charge.
119S&F for MCB single pole and neutral240 Volts40 Ampscomplete all as specified & directed by Engineer-In-charge.
120S&F forMCB single pole 5 to 30 Amps. complete all as specified & directed by Engineer-In-charge.
121M & L for earthing complete with galvanised steel earth plate electrode60cm X 60 cm X 6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner complete all as specified and directed by Engr in Charge.
122Supply and fixing in replacement of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area of 16 sqmm 4 core size laid in trenches under floor/roads/hard standing along poles etc complete all as specified and directed by Engr in Charge (Excavation and earth work, sand cushioning ,brick protection & GI pipe shall be measured and paid for separately).
123M & L filling dry and clean sand in trenches for cable 8 cm deep below and 15 cm above for cable cushioning complete all as specified and directed by Engr in Charge. Note:- Punning down thickness 18 cm shall be measured.
124M & L for sub class "B" brick of size 230x115x75mm laid flat work length equal to width of brick on sand for protection of under ground cable complete all as specified and directed by Engr in Charge
125M & L for GI pipe 40 mm dia Light grade fixing to wall or laying in floors for protection of cable complete all as specified and directed.