| 1 | Schedule \"A\" Section - I |
| 2 | Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete allas specified and directed by Engr-In-Charge. |
| 3 | Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed by Engr-In-Charge. |
| 4 | Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed by Engr-In-Charge. |
| 5 | Taking out unserviceable/defective/damaged/blockage GI/MS pipe 15 mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed by Engr-In-Charge. (Note: Exacavation and earhwork shall be measured and paid for separately.) |
| 6 | All as per serialitem No. 4.00 here-in-before but of size 20mm bore-ditto-. |
| 7 | All as per serialitem No. 4.00 here-in-before but of size 25 mm bore-ditto-. |
| 8 | All as per serialitem No. 4.00 here-in-before but of size 40mm bore-ditto-. |
| 9 | All as per serialitem No. 4.00 here-in-before but of size 50mm bore-ditto-. |
| 10 | All as per serialitem No. 4.00 here-in-before but of size 80mm bore-ditto-. |
| 11 | All as per serialitem No. 4.00 here-in-before but of size 100mm bore-ditto-. |
| 12 | All as per serialitem No. 4.00 here-in-before but of size 150mm bore-ditto-. |
| 13 | S&F GI/MS tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings such as bends , elbows,tees, short length , socket, union, check nuts, nipples and weldings etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed by Engr-In-Charge. |
| 14 | All as per serialitem No. 12.00 here-in-before but of size 20mm bore-ditto-. |
| 15 | All as per serialitem No. 12.00 here-in-before but of size 25mm bore-ditto-. |
| 16 | All as per serialitem No. 12.00 here-in-before but of size 40mm bore-ditto-. |
| 17 | All as per serialitem No. 12.00here-in-before but of size 50mm bore-ditto-. |
| 18 | All as per serialitem No. 12.00here-in-before but of size 80mm bore-ditto-. |
| 19 | All as per serialitem No. 12.00here-in-before but of size 100mm bore-ditto-. |
| 20 | All as per serialitem No. 12.00here-in-before but of size 150mm bore-ditto-. |
| 21 | S&F in replacement of Bronze gate valve for 15mm bore pipe,with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed as in repair complete all as specified and directed by Engr-In-Charge. |
| 22 | All as per serialitem No. 20.00 here-in-before but of size 20mm bore-ditto-. |
| 23 | All as per serialitem No. 20.00 here-in-before but of size 25mm bore-ditto-. |
| 24 | All as per serialitem No. 20.00 here-in-before but of size 40mm bore-ditto-. |
| 25 | All as per serialitem No. 20.00 here-in-before but of size 50mm bore-ditto-. |
| 26 | Taking out old unsv and Supplying, fixing and testing of cast steel Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Paking greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-150 mm, both ends flanged in existing line,afterremoval of old unserviceablesluice valve without damagingtoexistingpipeline complete all as specified and directed by Engr-in-charge.Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item. |
| 27 | All as per serialitem No. 25.00 here-in-before but nominal size DN-100 mm-ditto-. |
| 28 | All as per serialitem No. 25.00 here-in-before but nominal size DN-80 mm-ditto-. |
| 29 | S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 100 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one . |
| 30 | S&F Cast iron Non Return valve W/O by pass arangement , Swing type, of Size 150 mm bore, confirming to IS 5312, flanged ends with nuts bolts, washers complete including taking down of old one . |
| 31 | Construction ofbrick masonary pit of size 60 x 60 x 60cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1. (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli. |
| 32 | Construction ofbrick masonary pit of size 90 x 90 x 90 cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli. |
| 33 | Construction ofbrick masonary pit of size 120 x 120 x 120 cm internal size with MS sheet 3 mm thick and angle iron frame of size 40x40x6mm duly paintedwith 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and shown in drawingNo. STD- 1258, sheet 1/1 (original date - 30.11.93 and revised date - 15.09.2000 ) Note : Drawing mentioned above has not been enclosed herewith, however the same can be seen in the office ofGE Kasauli. |
| 34 | Taking down old unsv LT panel board including disconnecting all electric connection and accessories, supply and installing, testing and commissioning of LT indoor panel totally enclosed floor mounted type cabinet size 1.2x0.5x1.0Mtr fabricated made out of 16 SWG MS sheet and angle iron frame 40x40x6mm work cubical. The panel should be vermine proof with IP 55 protection suitable 415 Volt AC 50 Hz 3 phase 4 wire system panel board should be painted with two coated paint over one coat of primer. The panel shall be front opening type consisting of copper bus bar of 100 Amps capacity for phase and neutral and consisting of the following including wiring with PVC insulated strantneded coper conductor cable of suitable size including copper lugs etc:-(a) Incoming:-(i) MCCB 200 Amps 4 pole 25 KA 415 Volt - 01 Nos.(b) Outgoing:-(i) Fully automatic star delta starter air break type suitable for 15 HP 3 phase Motor - 01 No.(ii) Fully automatic star delta starter air break type suitable for 10 HP 3 phase Motor - 01 No.(iii) DOL startor suitable for 10 HP, 3phase motor-01 Nos. (iv) Digital volt meter 3 phase 415 volt 144 sqmm with 04 way selector switch 0-500 V-01 No. (v) Digital Amp meter 0-100 Amp 3 phase 415 volt 144 sqmm alongwith 3 Nos CTs of required capacity with 4 way selctor switch -01 No. (vi) LED indicating lamp (R, Y, B) with control switches-01 Set. (vii) MCB TP 415 Volt 63 Amp-01 No. (viii) MCB TP 415 Volt 32 Amp-02 Nos. (ix) MCB SP 230 volt 32 amp -01 No. (x) Single phase preventor protection. (xi) Reverse phase protection. (xii) Over load relay protection. (xiii) High/low voltage relay protection. |
| 35 | Taking Down old UNSV Dozing system deposited to water supply store and Supply, installation testing and commissioning ofDosing System along with injector, Square and Max output (flow rate) 12 cm Ltr/Hr of the following specification with complete accessories like lead tubing ,connecting ferrules,check valves etc all as specified and as directed by Engr-in-Charge.Specification :-1. Preparation Tank model No VST-1005 of net cap 170 Ltrs of FRP dosing tank 650 mm x net height 375 mm + conical 300 mm gross height with stand 100 mm consisting of (a) Water Inlet line (b) Outlet with Y Strainer (c) Drain (d) Over flow (e) Conical bottom for sludge deposition (f) Pot hole with cover(g) Level gauge (h) Agitator 120 W, 900 RPM, 1 phase flange mounted motor with plastic shaft and impeller.2. Service tank Model No VST -1006 of net cap 100 lts of FRP dosing tank top dia 540 mm x bottom dia 480 mm x height 575 mm consisting of :- (a) Water inlet line (b) Outlets with Y Stainer (c) Drain (d) Over flow (e) Level Gauge (f) Agitator 120 W, 900 RPM, 1 phase flange mounted motor with plastic shaft and impeller, (g) Inspection Report (h) Provision of mounting pump on lid/wall. |
| 36 | Supply of calcium hypo chloride, 65%-70% chlorine content, high strength granular disinfectant for treatment of drinking water complete all as specified and qty as per requirement and as directed by Engr-in-Charge. |
| 37 | Amount of credit of Rs. 42160.00 for retrived old material as mentioned in Schedule \"A\" section-II of tender document in pdf form, will be deducted offline while acceptence of tender. |