Attending Breakdowns Of Various 132 / 33 Kv Substation Under Etd-Iv, Varanasi. of interrupter in 33 KV CB pole by conducting following works:-(i) Opening of existing jumpers of damaged CB pole interrupter.(ii) Dismantling of damaged CB pole interrupte, Bhadohi-Uttar Pradesh

Uttar Pradesh Power Transmission Corporation Limited-UPPTCL has published Attending Breakdowns Of Various 132 / 33 Kv Substation Under Etd-Iv, Varanasi. of interrupter in 33 KV CB pole by conducting following works:-(i) Opening of existing jumpers of damaged CB pole interrupter.(ii) Dismantling of damaged CB pole interrupte. Submission Date for this Tender is 13-10-2021. Lightning Arrester Tenders in Bhadohi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29175149
Corrigendum : Attending Breakdowns Of Various 132 / 33 Kv Substation Under Etd-Iv, Varanasi. of interrupter in 33 KV CB pole by conducting following works:-(i) Opening of existing jumpers of damaged CB pole interrupter.(ii) Dismantling of damaged CB pole interrupte
Open Tender
Indian
Uttar Pradesh
Bhadohi
13-10-2021

Tender Details

Attending Breakdowns Of Various 132 / 33 Kv Substation Under Etd-Iv, Varanasi. of interrupter in 33 KV CB pole by conducting following works:-(i) Opening of existing jumpers of damaged CB pole interrupter.(ii) Dismantling of damaged CB pole interrupter by opening of upper terminal plate of CB pole.(iii) Replacement of defective pole interrupter by new one, fixing of interconnecting rod and fixing of upper terminal plate and then checking the CB mechanism for proper operation.(iv) Shifting of all scrap/damaged part to store. 3 Replacement of defective/damaged 33 KV VCB pole by conducting following works:-(i) Opening of jumpers of defective/damaged pole by dismantling after detaching it from operating shaft of the CB.(ii) Shifting of the defective/damaged pole from switchyard to store and shifting of the new/good condition pole, from store to the site.(iii) Erection of the good condition dismantled/new pole and get it connected with CB operating shaft and then get jumpers connected to the pole.(iv) Shfiting of all scrap/damaged part to store. 4 Replacement of following equipment in case of damage as per instruction manual and technical specification including dismantling and shifting of damage equipement upto store, shifting of new equipement from store to working place, erction of equipment and other associated work involve for completing the work including all cost of men material and T&P. 5 145 KV instrument transformer (CTs, PTs,) 6 145 KV post insulator 7 120 KV lightning arrestor 8 36 KV 3 phase VCB 9 36 KV 1-phase CT/PT 10 30 KV 1-phase LA 11 33/22/18KV post insulator 12 Replacement of damaged control/power cable original position including taking out damaged cable form cable trench and shifting to store.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Sep-2021 Corrigendum-1 Date 29-09-2021
2 29-Sep-2021 Corrigendum-2 Date 07-10-2021
3 01-Oct-2021 Corrigendum-3 Technical Bid 07-10-2021
4 07-Oct-2021 Corrigendum-4 Date 11-10-2021
5 11-Oct-2021 Corrigendum-5 Date 13-10-2021

Key Value

Document Fees
INR 236 /-
EMD
INR 2000.0 /-
Tender Value
INR 2 Lakhs /-

BOQ Items

Name of Work:Attending breakdowns of 132/33 KV substation under ETD-IV, Varanasi
Sl. No. Item Description
1Attending breakdowns of 132/33 KV substation under ETD-IV, Varanasi
2Changing of interrupter in 33 KV CB pole by conducting following works:- (i) Opening of existing jumpers of damaged CB pole interrupter. (ii) Dismantling of damaged CB pole interrupter by opening of upper terminal plate of CB pole. (iii) Replacement of defective pole interrupter by new one, fixing of interconnecting rod and fixing of upper terminal plate and then checking the CB mechanism for proper operation. (iv) Shifting of all scrap/damaged part to store.
3Replacement of defective/damaged 33 KV VCB pole by conducting following works:- (i) Opening of jumpers of defective/damaged pole by dismantling after detaching it from operating shaft of the CB. (ii) Shifting of the defective/damaged pole from switchyard to store and shifting of the new/good condition pole, from store to the site. (iii) Erection of the good condition dismantled/new pole and get it connected with CB operating shaft and then get jumpers connected to the pole. (iv) Shfiting of all scrap/damaged part to store.
4Replacement of following equipment in case of damage as per instruction manual and technical specification including dismantling and shifting of damage equipement upto store, shifting of new equipement from store to working place, erction of equipment and other associated work involve for completing the work including all cost of men material and T&P.
5145 KV instrument transformer (CTs, PTs,)
6145 KV post insulator
7120 KV lightning arrestor
836 KV 3 phase VCB
936 KV 1-phase CT/PT
1030 KV 1-phase LA
1133/22/18KV post insulator
12Replacement of damaged control/power cable original position including taking out damaged cable form cable trench and shifting to store.