| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-09-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-09-2021 |
| 2 | 17-09-2021 | Technical bid corrigendum | Technical Bid | 21-09-2021 |
| Sl. No. | Item Description |
| 1 | BOQ UPLOADED ON 02 SEP 2021 |
| 2 | SCH \"A\" PART-I (CIVIL WORKS) |
| 3 | Surface dressing n exceeding 15CM in any type of soil complete all as specified and as directed. |
| 4 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depthand getting out in any type of soil all as specified and as directed. |
| 5 | Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5mand not exceeding 3.0M in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depthand getting out in any type of soil all as specified and as directed. |
| 6 | Sand filling in floors or pavings laid in layers not exceeding 15CM thick, spread, levelled and rammed including watering complete all as specified and as directed. |
| 7 | Cement concrete in type D2, 1:4:8(using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 8 | Formwork to sides of concrete foundations, footings, bases ofcolumns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work for rough finished surfaces complete all as specified and as directed. |
| 9 | RCC Design mix M-30 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 10 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of conctrete complete all as specified and as directed. |
| 11 | RCC Design mix M-30 as in Columns, pillars, piers,posts and struts complete all as specified and as directed. |
| 12 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of conctrete complete all as specified and as directed. |
| 13 | RCC Design mix M-30 as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 14 | Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work; not exceeding 200mm thick(Horizontal or sloping) for rough finished flat surfaces of conctrete complete all as specified and as directed. |
| 15 | RCC Design mix M-30 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 16 | Formwork to chullah hoods, chajjas, fins, facia, troughs and similar items including edges for rough finished flat surfaces of conctrete complete all as specified and as directed. |
| 17 | RCC Design mix M-30 as inchajja, facia and the like complete all as specified and as directed. |
| 18 | Mild steel TMT bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed. |
| 19 | Mild steel TMT bars 6mm to 8mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in main reinforcement complete all as specified and as directed. |
| 20 | Mild steel TMT bars but 5mm dia and over upto and including 10mm dia, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers & binders complete all as specified and as directed. |
| 21 | Brick work with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of designation 50 complete all as specifed and as directed. |
| 22 | Brick work with fly ash bricks, old size, straight or curved on plan exceeding 6m mean radius in half brick thick wall built in cement mortar 1:4 of designation 50 complete all as specifed and as directed. |
| 23 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed. |
| 24 | Removing excavated surplus soil to a distance exceeding 250m and not exceeding 500m, depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 25 | Rendering 10mm thick in CM(1:6) with a top coat of rendering 5mm thick in CM(1:4) mixed with water proofing compound on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cement complete allas specified and as directed. |
| 26 | Rendering 15mm thick in CM(1:6) on fair faces of brickwork or concrete surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 27 | Rendering 5mm thick in CM(1:3) on ceiling surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 28 | Preparing newly plastered surfaces of wall and applying three coats of white wash on plastered wall surfaces including in narrow widths, bands, cornices, pilasters etc., complete allas specified and as directed. |
| 29 | Preparing newly plastered surfaces of wall,,applying two coats of cement paint over a coat of primer to match with the existing adjoining surfaces including in narrow widths, bands, cornices, pilasters etc., complete all as specified and as directed |
| 30 | Preparing newly plastered surfaces of ceiling and applying three coats of white wash including in narrow widths, bands, cornices, pilasters etc., complete allas specified and as directed. |
| 31 | Spreading, levelling the excavated material in floors or pavings laid in layers not exceeding 15CM thick and rammed including watering complete all as specified and as directed. |
| 32 | Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete allas specified and as directed. |
| 33 | Hardcore broken stone boulders of guagenot exceeding 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed. |
| 34 | Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete allas specified and as directed. |
| 35 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for and and removal of unserviceable debris outside of MD land complete all as specified and as directed. |
| 36 | Plain cement concrete 75mm thick, 1:3:6, type C1, using 20mm graded stone aggregate as in plinth protection surface finished fair and even complete all as specified and as directed. |
| 37 | Forming Construction joint 30mm deep x 10mm wide filledwith sealing compound grade \"A\" complete all as specified and as directed. |
| 38 | Plain cement concrete 100mm thick, 1:4:8, type D2, using 40mm graded stone aggregate as in sub base surface finished fair and even complete all as specified and as directed. |
| 39 | Plain cement concrete 100mm thick, 1:2:4, type B1, using 20mm graded stone aggregate as in flooring and surface finished even and smooth complete all as specified and as directed. |
| 40 | Rendering 10mm thick in CM(1:3)using water proofing compound on fair faces of concrete surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 41 | Preparing the rendered surface thoroughly to remove all loose particles, dirt / dust particles and applying a uniform coat of blown grade bitumen VG-10 @ 1.20 kg/sqm conforming to IS 702 over a coat of bitumen primer @ 0.40 Litres / Sqm followed by APP membrane reinforced with polyster non woven fabric 3mm thick weighing not less than 3.6 kg / sqm laid on primed surface by forced application followed by a finishing coat of solar reflective aluminium paint @ 0.10 litres / sqm complete all as specified and as directed. |
| 42 | Supply only integral Water proofing compound all as specified and as directed. |
| 43 | Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete of Fe 410 -W (Gde-E- 250) quality-A, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 44 | Preparing new surfaces of steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 45 | Steel windows with side hung shutters including projecting typehinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or welded including one shop coat primer complete all as specified and as directed. |
| 46 | Steel windows with side hung shutters including projecting typehinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded including one shop coat prime complete all as specified and as directed. |
| 47 | Plain cement concrete, type C1, 1:3:6, using 20mm graded granite stone aggregate as in bed blocks andthe like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and as directed. |
| 48 | Preparing surfaces of wood and wood based materials, steel and iron work, new or old, as in ends of posts, backs of chowkats etc., area exceeding 0.10 sqmbut not exceeding 0.50 sqm each and treated with tar or coal tar black paint and sanding complete allas specified and as directed. |
| 49 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors and similar work conforming to Fe-290, Gde-E-165complete all as specified and as directed. |
| 50 | Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a) quality over cement screed 1:4, 20mm thick complete all as specified and as directed. |
| 51 | Powder coated aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc.complete all as specified and as directed. |
| 52 | Prelaminated particle board minimum 9mm thick, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination complete all as specified and as directed. |
| 53 | 40mm dia, cupboard knobs fixed with nut, screw and washer of brass polished complete all as specified and as directed. |
| 54 | Anodisedaluminiumslidingwindows,allasgiven here-in-aftercompleteallasspecifiedandasdirected. Frame:-Three track section shall be of weight not less than1.060 kg/m. Shutter:-Consists of 03 Nos Shutters i.e 02 Nos od Glazed shutters and 01 No of Gauzed shutter. Sections of shutter (stiles and rails) sections shall be of weight not less than 0.562 kg/m. Builders hardware:-Standard locking device for glazed shutters. |
| 55 | Note:- |
| 56 | (a) All aluminium sections including glazing clips, snap beading, joining cleats, rubber packing, screws etc.,as required are deemed to be included in the rate quoted. |
| 57 | (b) Glass or wire cloth as required shall be measured and paid separately. |
| 58 | (c) The fixtures given are for window unit of size exceeding 1.0 sqm but not exceeding 2.20 sqm. |
| 59 | Prelaminated particle board minimum 18mm thick, exterior grade, one side prelaminated with decorative choice lamination and other side balancing white fixed to timber/aluminium frame complete all as specified and as directed. |
| 60 | Continuous (piano) hinges, mild steel, bright finish or electrogalvanised 30mm width of flap complete all as specified and as directed. |
| 61 | Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed. |
| 62 | Precast cement concrete in 1:2:4, type B1 (using 20mm graded stone aggregate) set in cement mortar 1:4 as in kerb stone etc., complete all as specified and as directed. |
| 63 | Concrete flooring 100mm thick with RMCM-20 grade using (design Mix) vaccum dewatering method, laid in alternate bays including steel form work of MS channel sections of depth equal to thickness of concrete floor and trowelled with power trowel float finish to obtain level and joints filled with sealing compound complete all as specified and as directed. Note: Joint filling sealing compound shall be measured and paid seperately under respective item. |
| 64 | Wear proof topping 20mm thick (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complte all as specifed and as directed.Note: Metallic hardner as required shall be measured and paid seperately. |
| 65 | Supply only of metallic hardner to be incorporated in wear proof topping complete all as specified and as directed and as per manufacturer\"s instructions. |
| 66 | Forming 12 mm thick expansion joints filled with pre-formed bituminous filler 100mm depth and top 30mm shall be primed and sealed with sealing compound, Grade ‘B’ complete all as specified and as directed. |
| 67 | Demolition of brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed. |
| 68 | Granite (of any type) work, of thickness 18mm to 20mm, (polished) for wall lining (veneering to wall) over 15mm thickcement mortar 1:3 including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite stonecompleteall as specified and as directed. |
| 69 | Granite (of any type) work, of thickness 18mm to 20mm, (table rubbed and polished) in wash basin platforms, cooking platforms, steps, jambs, pillars, windows and the like set in cement mortar 1:4, 20mm thick, including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite stonecompleteall as specified and as directed. |
| 70 | Roughening surfaces of old concrete surface by picking, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry at the rate of 3.0kg of cement per square metre complete all as specified and as directed. |
| 71 | Excavating in post holes (or similar holes) each n exc 0.5cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and removing the surplus soil outside MD land complete all as specified and as directed. |
| 72 | Plain cement concrete in 1:2:4, type B1 (using 20mm graded stone aggregate) as in walls, retaining walls, basement walls, ballast walls, posts and the like; any thickness; above top offootings; including attached pilaster and buttressescomplete all as directed. |
| 73 | Joist, channel, angle, or tee sections, fixed independently, withoutconnecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)of Fe 410-W (Gde-E- 250) quality-A complete all as directed. |
| 74 | Rooftrusses (framed), trussed, purlins, crane gantries, rails andfastenings and heavy bracket framing (Beam, tee, angle, channelor flat sections) including distance pieces, cleats etc. Fe 410-W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 75 | Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded without any attachment of grade Fe-410-W (grade E-250) quality A complete all as specified and as directed. |
| 76 | S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long and not exc 10cm and dia of bolt 11 to 15mm complete all as specified and as directed. |
| 77 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 78 | Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 79 | Taking down chowkats or frames(wooden / steel) with shutters(without taking off shutters from the frames) exceeding 1.50 sqm butnot exceeding 4.00 sqmeach and removing from site under Sch of credit complete all as specified and as directed. |
| 80 | Taking down chowkats or frames (wooden / steel) with shutters(without taking off shutters from the frames) not exceeding 1.50 sqmeach and removing from site under Sch of creditcomplete all as specified and as directed. |
| 81 | Taking down shutters of any description exceeding 1 sqm and not exceeding 2 sqm,easing adjusting and refixing in same opening complete all as specified and as directed. |
| 82 | Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, as in IInd class hardwood complete all as specified and as directed. |
| 83 | Plain, framed, panelled shutters (any number of panels), of IInd class hardwood, 35mm thick with panelsof wood particle board with commercial face veneers complete all as specified and as directed. |
| 84 | Glazed and skeleton shutters, of IInd class hardwood, 35mm thickopen rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, divided into squares, with plain, chamfered or rounded. mitred and rebated sash bars for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and as directed. |
| 85 | Note:- |
| 86 | Glass or wire cloth as required shall be measured and paid separately. |
| 87 | Glazed and skeleton shutters, of IInd class hardwood, 30mm thickopen rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, divided into squares, with plain, chamfered or rounded. mitred and rebated sash bars for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b) complete all as specified and as directed. |
| 88 | Note:- |
| 89 | Glass or wire cloth as required shall be measured and paid separately. |
| 90 | Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, length of bolt 300mm complete all as specified and as directed. |
| 91 | Butt hinges, medium weight, cold rolled mild steel and fixed / welded to frame of size 100mm complete all as specified and as directed. |
| 92 | Butt hinges, medium weight, cold rolled mild steel and fixed / welded to frame of size 75mm complete all as specified and as directed. |
| 93 | Extruded aluminium alloy handles, fabricated type, anodised of size 150mm complete all as specified and as directed. |
| 94 | Extruded aluminium alloy handles, fabricated type, anodised of size 100mm complete all as specified and as directed. |
| 95 | Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 150mm complete all as specified and as directed. |
| 96 | Aluminium anodised barrel tower bolts, of extruded section and fixed, length of bolt 100mm complete all as specified and as directed. |
| 97 | Ordinary rat tail rod pattern springs, 300mm, mild steel, including roller and roller plate complete all as specified and as directed. |
| 98 | Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, overall length of cover plate 150mm including fixing on floor complete all as specified and as directed. |
| 99 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed. |
| 100 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staplesas in repairs complete all as specified and as directed. |
| 101 | Sheet glass, 3mm thick, ordinary quality and glazing with oil putty in squarenot exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 102 | Sheet glass, 4mm thick, ordinary quality and glazing with aluminium beading in squarenot exceeding 0.5 sqm in each pane including hacking out old broken glass complete all as specified and as directed. |
| 103 | Preparing new surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 104 | Preparing old painted surfaces of wood and wood based materials of any description, not otherwise described, over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 105 | Dismantling of wall and ceiling boards or insulator board/slabs/blankets any thickness including cover fillets all as specifed and as directed, |
| 106 | Aluminium snap grid framework (powder coating of minimum 50 microns) of grid size 605mm x 605mm of main and cross tee of size 40mm x 25mmx 1.5mm thick and wall angle size 25mm x 25mm x 1.5mm thick for false ceilingincluding fixing of supporting hangerscomplete all as specified and as directed.Note: The hangers for support of false ceiling shall be measured and paid separately. |
| 107 | Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 108 | PVC insulation panels 10mm thick with EPS stuck to 1mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium complete all as specified and as directed. |
| 109 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 110 | Non-skid ceramic coloured tiles, minimum 7mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match of superior finish, grade B-II (a)quality over cement screed 1:4, 20mm thick complete all as specified and as directed. |
| 111 | Glazed ceramic tiles of grade B-III coloured of size 350mm x 250mm/ 450mm x 350mm, minimum 7mm thickin vertical surfaces such as skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including a backing coat of cement mortar 1:3. 10mm thick complete all as specified and as directed. |
| 112 | SCH \"A\" PART-II (INTERNAL ELECTRIFICATION) |
| 113 | Taking down carefully unserviceable point wiring copper / aluminium (light, fan, socket or power) complete, including removal of batten / conduit / gutties / wooden board etc., including fittings and fixtures such as switches, ceiling roses, regulators, sockets, light fittings, etc., and separating the serviceable items for reuse, removal from site under Sch of credit and removal of unserviceable items out of site and making good the disturbed surfaces of walls, ceilings etc.,complete all as specified and as directed. |
| 114 | Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including non-metalic rigid PVC conduit, conduit fittings and conduit accessories not less than 25 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision ofone 1.5 sqmm PVC insulated single core multistranded copper conductor green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep,concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., including taking down the existing unserviceable point wiring complete all as specified and as directedfor one light point controlled by one switch. |
| 115 | Note:- |
| 116 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 117 | All as per BOQ SL No.106 here-in-before but for one exhaust fan/wall mounting fan point controlled by one switch. |
| 118 | Note:- |
| 119 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 120 | All as per BOQ SL No.106 here-in-before but for one ceiling fan point controlled by one switch and regulator |
| 121 | Note:- |
| 122 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 123 | All as per BOQ SL No.106 here-in-before but for One switch socket outlet point 3 pin 5 Amps on same board with other switches. |
| 124 | Note:- |
| 125 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 126 | All as per BOQ SL No.106 here-in-before but for One switch socket outlet point 3 pin 5 Amps on independent board. |
| 127 | Note:- |
| 128 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 129 | All as per BOQ SL No.106 here-in-before but for point wiring with two 4 sqmm single core copper conductor multistranded cable and one 4 sqmm PVC insulated single coremultistranded cable as earth continuity conductor green in colour for one 3 pin switch socket outlet, 15 Amps, on independent board complete all as specified and as directed. |
| 130 | Note:- |
| 131 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 132 | Ceiling rose, 3 terminal, PVC / polycarbonate, insulated body complete as specified and as directed. |
| 133 | Switch piano, flush type single pole, one way, 5 Ampscomplete all as specified and as directed. |
| 134 | Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps universal type complete all as specified and as directed. |
| 135 | Switch socket combination, flush type, 2 in 1, 3 pin, 5 Amps and 15 Amps universal typecomplete all as specified and as directed. |
| 136 | Stepped type electronic fan regulator, 300 W, flush type, fixed on existing laminated sheet complete as specified and as directed. |
| 137 | LED tube light fitting 20W, surface/wall mounted LED batten with polycarbonate housing & integrated electronic driver complete including connection from ceiling rose to light fitting with twin core cable 23/0.0076 sqmm complete including taking down the existing unserviceable fitting all as specified and as directed.Make: C & S Cat No NAKSHATRA/20W or equivalent of makes as listed here-in-after. |
| 138 | LED tube light fitting 2x16W, highly rebost industrial box type luminaire suitable for twin T8 LED tube and integrated electronic driver and connection from ceiling rose to light fitting with twin core cable 23/0.0076 sqmm complete including taking down the existing unserviceable fitting all as specified and as directed.Make: Crompton Greaves Cat No IGP162LT8-16 or equivalent of makes as listed here-in-after. |
| 139 | LED street light luminaire outdoor type 25 Watt new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP66 with high power LEDs as light source and electronic driver suitable for operation on AC, single phase 220 / 230 Volts, 50 Hz supply, and including provision of two single core 4 sqmm copper conductor PVC insulated 1100v cable not less than 8m long etc connecting from juction box to pole including taking down existing unserviceable fitting complete all as specified and as directed. |
| 140 | Note:- |
| 141 | (a) Make shall be Havells Cat No ENDURAPEARLSL25WLED757SASYTOPCMP or equivalent of makes as listed here-in-after. |
| 142 | (b) For all other mandatory requirements of LED fittings, please refer under Particular Specifications here-in-after. |
| 143 | Power / Sub-main wiring with PVC insulated unsheathed, 1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmmFRLSH conforming to IS-694, drawn through and includingsuitable dia rigid PVCconduit, conduit fittings and conduit accessories alongwith one run 6 sqmm PVC insulated single core multistrandedcopper conductorcable FRLSH (green) asearth continuity conductor concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc. and connecting tocommon earth dolly including taking down existing unserviceable sub main wiring complete all as specified and as directed. |
| 144 | Note:- |
| 145 | (a) Two runs of 6 sqmm cable and one run of 6 sqmm cable and one run of conduit will be measured as one length. |
| 146 | (b) Cutting chases on walls for concealing pipes and cost of terminal box is deemedto be included in the item rates quoted for sub-main wiring / circuit wiring. |
| 147 | Taking down MCB DB including inner components and provision of MCB DB SPN 8 way, doubledoor, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCBdouble pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth linkand connecting up complete all as specified and as directed. |
| 148 | MCB 6-40 Amps, SP, 240 Volts, 50 Hz, AC supply, \"B\" curve, with breakingcapacity of 10 kAcomplete all as specified and as directed. |
| 149 | MCB 40 Amps, SPN, 240 Volts, 50 Hz, AC supply, \"B\" curve, with breakingcapacity of 10 kAcomplete all as specified and as directed. |
| 150 | MCCB 125 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz, 16 kA breaking capacity, with fixed thermal and fixed magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version)complete allas specified and as directed. |
| 151 | Loadline MCB DB TPN 4 way, verticle, double door, powder coated, 415 Volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for fixing MCCB 125 Amps 4 pole as incomer and SP MCBs 40/63 Amps as outgoing with tinned copper bar, neutral link, earth link and connecting up complete allas specified and as directed. Make: Havells Cat No DHDLVDRWGOF004 or or equivalent makes listed here-in-afterNote: Incoming MCCB and outgoing MCBs shall be measured and paid seperately. |
| 152 | Taking down unserviceable ceiling fan and refixing in position duly rectified the defects, renewal of ball bearing, oiling/greasing/winding and testing for proper functioning including one coat of painting and writing MES No complete all as directed. |
| 153 | Taking down unserviceable aircirculator and refixing in position duly rectified the defects, renewal of ball bearing, oiling/greasing/winding and testing for proper functioning including one coat of painting and writing MES No complete all as directed. |
| 154 | Exhaustfan, heavy duty, 300mm sweep, 1400 RPM, with louvers, metal body conforming to IS-2312-1967, AC singlephase, 240 Volts, 50 Hzand connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copperconductorcablefromceilingroseor connectorto fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed. |
| 155 | Note:- |
| 156 | Make shall be of Usha Cat No 300mm S.PH TURBO HDEF or equivalent of makes as listed here-in-after. |
| 157 | Exhaustfan, heavy duty, 450mm sweep, 1400 RPM, with louvers, metal body conforming to IS-2312-1967, AC singlephase, 240 Volts, 50 Hzand connecting including provision of two way PVC connectors, 1 sqmm flexible three core multistranded copperconductorcablefromceilingroseor connectorto fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed. |
| 158 | Note:- |
| 159 | Make shall be of Usha Cat No 450mm S.PH TURBO HDE or equivalent of makes as listed here-in-after. |
| 160 | Taking out existing earthing materials and provision of Earthing complete with galvanised iron earth plate electrode 600mm X600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directlyin ground vertically to a depth not lessthan2.25 metres below ground level with top edge of the earth plateat a depth not less than1.5 metres belowgroundlevel, connectedto earth leadasdescribedhere-in-beforebymeansofbolts,nuts, washers and checknuts made out ofgalvanised iron or mild steel, earthingleadprotectedby asdescribedhere-in-beforeand connected to main switch board or main control board or electric poleall asshownonelectricalplate No.3of MES Sch Part-Iincluding necessaryearth work and excavation in any type ofsoil,plain cementconcrete1:3:6,typeC1 chamber,reinforcedcement concretecover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm diaTMT barsat140mmcentreto centrebothways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugsincluding testing complete all as specified and as directed. |
| 161 | Taking down copper/aluminium flame proof point wiring for light complete including fittings such as rotary switches etc., and making good the disturbed surfaces on wall/floor etc., complete all as specified and as directed. |
| 162 | Point wiring on stone / brick masonry wall complete with two 1.5 sqmm single core PVC insulated 1100 volts grade unsheathed cable confirming to IS-694, 1977 with multistranded copper conductor, drawn through and including steel conduit, conduit fittings and conduit accessories not less than 25 mm dia concealed in walls and fixed with suitable clamps on ceiling / roof trusses etc., and including provision ofone 1.5 sqmm PVC insulated single core multistranded copper conductor green in colour as earth continuity conductor and connected to common earth dolly, including pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet, 60mm deep,concealed in walls, duly painted with two coats of anti-corrosive over a coat of red oxide zinc chrome primer and covered with bakelite hylam sheet cover 3mm thick fixed with cadmium plated screws for housing the switches, socket outlets, fan regulators etc., including taking down the existing unserviceable point wiring complete all as specified and as directedfor one light point controlled by one Rotary switch. |
| 163 | Note:- |
| 164 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 165 | All as per BOQ SL No.132 here-in-before but for one exhaust fan point controlled by one Rotary switch. |
| 166 | Note:- |
| 167 | Cost of terminal box and cutting chases for concealing pipes is deemedto be included in the item rates quoted for point wiring. |
| 168 | Flame proof/weather proof LED tube light fitting 1 X 20 W, 4 feet long with 02 Nos cable entries and 01 entry plugged with proper flame proof plug, terminal block, wire guard including all accessories complete all as specified and as directed.Make: Crompton Cat No EXTN1LT8-16/20 or equivalent makes listed here-in-after. |
| 169 | Flame proof Exhaustfan, 380mm sweep, with louvers, metal body , AC singlephase, 240 Volts, 50 Hzand connecting including provision of suitablel size multistranded copperconductorcablefromceilingroseor connectorto fan including earthing and fixing arrangements like making hole in wall and finishing to shape to match adjoining surface and writing MES No.20mm height with synthetic enamel paint black complete all as specified and as directed. |
| 170 | Switch flame proof rotary type with terminal box in LM6, 16A, single pole 250V complete all as specified and as directed. |
| 171 | Fixing only switch flame proof rotary type with terminal box in LM6, 16A, single pole 250V complete all as specified and as directed.Note: Rotary switches obtained from from Noshall be reused. |
| 172 | Dry river sand laid to required width of trench at bottom and top forcable cushioning all as specified and as directed. |
| 173 | Note:- |
| 174 | Punned thickness only shall be measured. |
| 175 | Common burnt bricks sub class \"B\" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection complete all as specified and as directed. |
| 176 | Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches/ under floor / / under roads / crossings etc., ofbore of pipe 40mm for cable protection complete all as specified and as directed. |
| 177 | Provision of XLPE insulated, armoured,heavy duty electric cable with aluminium conductor, 16 sqmm, 4 core,1100 volts grade,in trenches / drawn through pipe / fixed on walls/ bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipmentscomplete all as specified and as directed. |
| 178 | MCCB 63 Amps, 3 pole, 415 V, 50 Hz with rupturing capacity 10KA adjustable thermal and fixed magnetic settings complete all as directed. |