Spl Repairs To Flooring Plastering Roofing In Bldg No E36 E37 E38 Of 3 Dogra And Provision Of 1 No Toilet Near Bldg 7 Ib Line At Arty Centre Under Ge Golconda Spl Repairs To Flooring Plastering Roofing In Bldg No E36 E37 E38 Of 3 Dogra And Provision Of 1 , GE GOLCONDA-Telangana

Military Engineer Services-MES has published Spl Repairs To Flooring Plastering Roofing In Bldg No E36 E37 E38 Of 3 Dogra And Provision Of 1 No Toilet Near Bldg 7 Ib Line At Arty Centre Under Ge Golconda Spl Repairs To Flooring Plastering Roofing In Bldg No E36 E37 E38 Of 3 Dogra And Provision Of 1 . Submission Date for this Tender is 30-09-2021. Shed Construction Tenders in GE GOLCONDA Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

29064193
Corrigendum : Spl Repairs To Flooring Plastering Roofing In Bldg No E36 E37 E38 Of 3 Dogra And Provision Of 1 No Toilet Near Bldg 7 Ib Line At Arty Centre Under Ge Golconda Spl Repairs To Flooring Plastering Roofing In Bldg No E36 E37 E38 Of 3 Dogra And Provision Of 1
Open Tender
Indian
Telangana
GE GOLCONDA
30-09-2021

Tender Details

Spl Repairs To Flooring Plastering Roofing In Bldg No E36 E37 E38 Of 3 Dogra And Provision Of 1 No Toilet Near Bldg 7 Ib Line At Arty Centre Under Ge Golconda Spl Repairs To Flooring Plastering Roofing In Bldg No E36 E37 E38 Of 3 Dogra And Provision Of 1 No Toilet Near Bldg 7 Ib Line At Arty Centre Under Ge Golconda

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Sep-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-09-2021

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
INR 16 Lakhs /-

BOQ Items

Name of Work: SPL REPAIRS TOFLOORING, PLASTERING, ROOFING IN BLDG NO. E-36, E-37 & E-38 OF 3 DOGRA AND PROVN OF 01 TOILET NEAR BLDG 7 IB LINE AT ARTY CENTRE UNDER GE GOLCONDA.
Sl. No. Item Description
1Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation n.exc 10 sqm on plan and getting out in hard/dense soil.
2M&L for plain cement concrete 1:4:8 type D2 using 40mm graded aggregate as in foundation.
3M&Lfor Walling of random rubble, Secunderabad pattern, regular course, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
4Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils.
5Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting pointin soils.
6M&L for 25 mm thick Damp Proof Course in cement concrete 1:2:4, Type B-0 mixed with water proofing compound to horizontal or vertyical surfaces including necessary formwork complete. Note: (i) Water proofing compound shall be measured and paid separately. (ii) Water proofing compound not to be mixed for levelling course.
7M & L for brick work with sub-class `B" bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all specified and directed.
8M&L for Brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all specified and directed.
9M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete.
10Ditto as item No 9 above but 6 to 8mm dia bars
11M&L for RCC 1:2:4 type B1 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like.
12M&L for RCC 1:2:4 type B1 using 20mm graded aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span.
13Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces complete all as specified and directed.
14Use and waste of formwork to soffits and sides of floor or roof beams, lintels for rough finished surfaces complete all as specified and directed.
15Spreading and levelling in layers n exc. 25 cm thick and well ramming including watering as required in floors complete all as specified and directed (soil obtained from item No 1).
16M&L for Hard core of guage n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete.
17M&L 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in plinth protection, finished even and smooth with out using extra cement.
18M&L for 75 mm thick plain cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base of floor laid in alternate bays including necessary form work complete.
19M&L for non skidceramic colour tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 Sqm but not exc 0.11 sqmin floors laid over and including 15mm thick screed in CM 1:6 set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles.
20M&L for glazed ceramic coloured tiles in vertical surfaces 300x200x7mm thick over and including 10mm thick back coat in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match.
21M&L for15mm thick rendering in CM 1:4 on brick or concrete surfaces finished even and smooth (without using extra cement).
22M&L Rendering 10mm thick on brick work or concrete surface in cement mortar 1 : 6 and finished even and smooth without using extra cement.
23M&L for 5 mm thick rendering in CM 1:3 on ceiling surfaces finished even and smooth without using extra cement.
24M&L for 3 coats of white wash on newly plasteredceiling surfaces including preperation of surface.
25M&L for two coats of cement based paint on newly plastered surfaces of walls including preperation of surface.
26M & L for three coat of white wash on new surface of wall including preparation of surfaces.
27S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening etc. complete all as specified and directed.
28S&F solid PVC Panel Door shutter 30mm thick style consisting of Frame made out of M.S Tube for top & Bottom rails, MS Frame shall be covered with heat moulded, Plain colour PVC’C’ channel having aPVC Sheets strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for Top rail, lock rail bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour 5mm thick PVC sheet fitted in the MS Frame, welded/ sealed to stiles and rail with suitable PVC sheet beading and jointed together with solvent cement all as per manufacture instruction all as specified.
29S&F 100 MM Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type B-21.
30S & F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed.
31S & F 150 mm long extruded aluminium alloy handles, fabricated type., anodised
32S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete.
33S&F steelventilator with top hung shutter including hinges, steel peg stay complete.
34S&F 3mm thick sheet figured glass, pin head type and glazing with wooden beads or oil putty in square not exc. 0.50 Sqm in each pane complete.
35M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all specified and directed.
36S & F vitreous china wash down water closetpan of padestel pattern whitewith P or S trap including, seat cover etc completeall as specified and directed .
37Supply and fix PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and32mm PVC flush pipe.
38Supply and fix wash hand basinVitreous china white flat back size 550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets.
39S & F 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed.
40Supply and fix 900mm long PVC waste pipe of bore 32 mm to WHB all as specified.
41Suppy and fix 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.
42S&F of PTMT towel rail 600mm long fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190 gms)
43S&F 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot" or ‘Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
44S&F 15mm bore Stop valves (angle cock), cast copper alloy, fancy type, chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed.
45Supply and fixed 15 mm bore Bib taps, brass chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule.
46Supply and fix PVC connection 15mm size with PTMT nuts of length 600mm.
47S&F Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I 2009 of capacity 500 liter.
48S & F brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed, 15mm bore complete.
49S&F steel Tubes, ‘Medium grade’ galvanised, with all fittings, fixed to walls / ceilings or laid in floors, for 15 mm bore.
50S&F steel Tubes, ‘Medium grade’ galvanised, with all fittings, fixed to walls / ceilings or laid in floors for 20 mm bore.
51S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore.
52S&F of Ball valves high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed for 20mm bore pipe.
53S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls,110mm bore.
54S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110mm bore.
55S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore.
56S&F PVC (SWR) bends any radius 110mmbore.
57S&F PVC (SWR) bends any radius with access doors 110mm bore.
58S&F PVC (SWR) bends any radius 75mm bore.
59S&F PVC (SWR) bends any radius with access doors 75mm bore.
60S&F PVC (SWR) junction single, (Single T) equal or unequal with access door 75 mm bore.
61S&F PVC (SWR) vent cowl 110mm bore.
62S&F PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement.
63M&L salt glazed stone ware gully traps square or rounded mouthed type, 150 x 150 mm fixed in cement concrete complete.
64M& L salt glazed stone ware pipes (Grade "A") 100mm internal dia laid in trenches and jointing socket end with packed spun yarn and cement mortar1:1.
65M&L for Cement Concrete 1:3:6 type C-2 as concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, for 100 mm dia SWG pipe.
66M& L salt glazed stone ware pipes (Grade "A") 150mm internal dia laid in trenches and jointing socket end with packed spun yarn and cement mortar1:1.
67M&L for Cement Concrete 1:3:6 type C-2 as concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested, for 150 mm dia SWG pipe.
68Cutting in to existing manholes for connecting new drains making good to pipe 100mm internal dia and rendering cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching.
69M&L PCC 1:2:4, type B1 (using 20 mm graded stone aggregated) as in benching to manholes.
70M&L PCC 1:2:4, type B1 (using 20 mm graded stone aggregated) as in copping incl necessary form work all as specified.
71M&L PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in pre-cast cover slabs for manholes incl necessary form work set in CM 1:4 all as specified. (Reinforcement will be measured & paid separately)
72Dismantling of AC sheets corrugated or semicorrugated in roof coverings.
73M & L for 6mm thick asbestos cement corrugated or semi-corrugatedsheets in roofs, walls etc. fixed with L- type or J-type or cranked hooks bolts complete all specified and directed.
74M & L for asbestos cement two pieces adjustable plain wing ridge 6mm thick fixed with J hook and bolts etc complete all specified and directed.
75Dismantling wrought iron or mild steel work of any description not otherwise provided for.
76S & F for MS framed structure roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all specified and directed.
77Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc.
78Taking down cement plaster on wall of any desdriptions incl racking out joints for key, scrubbing with water etc. complete all specified and directed.
79M&L for two coats of oil bound distemper over a coat of primer on newly plastered surfaces including 3mm thick wall care putty on wall including preperation complete all specified and directed.
80M&L for complete removal of existing treatment and applying 3mm thick wall care putty on wall rubbing it with sand paper to achieve smooth surface and applying two oil bound distemper over a coat of primer complete all specified and directed.
81M&L for complete removal of existing treatment and applying two coats of cement base paint on walls surfaces complete all specified and directed.
82M&L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all specified and directed.
83M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all specified and directed.
84Demolition of cement concrete (Unreinforced) in ground floors and pavings n exc 15cm thickness (Below or above Ground level) complete all as directed.
85Dismantling Stone slabs and tiles of any description or thickness in floors, plinth Protection, aprons etc Laid, bed-ded and pointed in any mortar, complete all as specified and as directed.
86M&L 15 - 20 mm thick Polished shahabad stone slab (hand cut) in flooring laid over screed bed20 mm thick in CM 1:6, jointed and pointed in CM 1:3 including Grinding & Polishing the shahabad stone floor with seven cut machine polishing all as specified and all as directedby Engineer-in -Charge.
87M&L 15 - 20 mmthick Polished shahabad stone slab in skirting including 10mm thick backing coat in CM 1:4, jointed and pointed in CM 1:3 including Grinding & Polishing the shahabad stone skirting with seven cut machine polishing all as specified and all as directedby Engineer-in -Charge
88S & F in repairs stainlesssteel wire cloth, 0.36 mm nominaldia of wire and average width of aperture 1.4 mm and fixed with wooden beeds complete all specified and directed.
89M&L point wiring for one light point/ fan point controlled by one switch with 1.5 Sqmm multi stand copper conductor cablePVC( FRLS) insulated unscheathed copper conductor single core multi stand and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC rigidconduit not less than 20mm dia size ”with all fittings for concealed type on stone / brick masonary wall roof etc in new sunk box of 1.6mm thick & 3 mm thick plastic laminated sheet for housing switches , socket, regulator etc. including running chases, pinning in complete all as specified and directed at site.
90All as per item no: 89 but One 3 pin 5/6 Amps switch socket outlet on independent board Complete all specified and directed at site.
91All as per ser item No: 89 here in before but for one 3 pin socket outlet 15 Amp independent board using cable of size 2.50 sqmm.
92M&L switch piano flush type single pole one way 5 Amps
93S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminais all as specified and directed at site.
94S&FSwitch socket outlet combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed at site.
95S&FSwitch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed at site .
96M&L lamp holder insulated body with back plate suitable for battern fittings complete all specified and directed at site.
97Supply and fixing LED BULB9W AC 240V Complete all specified and directed at site.
98S&F LEDtube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including LED Tube rod connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as specified and directed at site.
99S&F Energy efficiency LED Building Security liight fitting of 25 watt with IP 66 degree of protection including nuts, bolts, fixtures complete.
100S&F Exhaust fan of sweep 250 mm, 1200 RPM 230 volts, 50 Hz complete.
101S & FMCB single pole 240 Volts,6 to 32 amps complete all specified and directed at site.
102Supply and fixing geyser for New generation energy saving & enviromental friendly long life versitile pressure die cast capacity 25ltrs Make :Havells Cat No : GHWAMJSIV025/ Equivalent