Erection Of Repair To Govt. ( Co-Ed ) , Sr. Sec. School, Laxmi Bai Nagar, New Delhi During 2019-20. ( Sh:- Repair Of Staff Toilet In Principal Room, Repair Of Plaster Work, Broken Tiles Repair, Door Window Repair In Principal Room, Roof Repair At, safdarjung enclave-Delhi

Public Works Department-PWD has published Erection Of Repair To Govt. ( Co-Ed ) , Sr. Sec. School, Laxmi Bai Nagar, New Delhi During 2019-20. ( Sh:- Repair Of Staff Toilet In Principal Room, Repair Of Plaster Work, Broken Tiles Repair, Door Window Repair In Principal Room, Roof Repair At. Submission Date for this Tender is 08-09-2021. Building Work Tenders in safdarjung enclave Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

29041740
Erection Of Repair To Govt. ( Co-Ed ) , Sr. Sec. School, Laxmi Bai Nagar, New Delhi During 2019-20. ( Sh:- Repair Of Staff Toilet In Principal Room, Repair Of Plaster Work, Broken Tiles Repair, Door Window Repair In Principal Room, Roof Repair At
Open Tender
Indian
Delhi
safdarjung enclave
08-09-2021

Tender Details

Erection Of Repair To Govt. ( Co-Ed ) , Sr. Sec. School, Laxmi Bai Nagar, New Delhi During 2019-20. ( Sh:- Repair Of Staff Toilet In Principal Room, Repair Of Plaster Work, Broken Tiles Repair, Door Window Repair In Principal Room, Roof Repair At Many Places In Fround Floor, Single Story Building And Top Floor, Replacement Of Rcc Tank By Pvc Tank With Platform, Roof / Plaster Work In Pump Housed And Chowkidar Room, Repair Work In Staff Toilet Wcl Blockage And Wooden Door Replacement ) . ( Sw - Balance Work ) .

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 3.64 Lakhs /-

BOQ Items

Name of Work: - EOR to Govt. (Co-ed), Sr. Sec. School, Laxmi Bai Nagar, New Delhi during 2019-20.(Sh:- Repair of staff toilet in principal room, repair of plaster work, broken tiles repair, door window repair in principal room, roof repair at many places in fround floor, single story building and top floor, replacement of RCC tank by PVC tank with platform, roof/plaster work in pump housed and chowkidar room, repair work in staff toilet WCL blockage and wooden door replacement). (SW - Balance work).
Sl. No. Item Description
1Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
2Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
3Providing sand stone slab for roofing and laying them in cement mortar 1 : 4 (1 cement : 4 coarse sand) over wooden karries or R.C.C. battens or structural steel sections (Karries or battens or structural steel sections to be paid separately), including pointing the ceiling joints with cement mortar 1:3 (1 cement : 3 fine sand ) complete : Red sand stone slab 40 to 50 mm thick
412 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
518 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).
6Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. Two or more coats on new work
7Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
8Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
9Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
10Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
11Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
12Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. INTERNAL WORK - EXPOSED ON WALL 25 mm nominal outer dia Pipes
13Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Circular tank
14Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
15Add CPWD Cost Index@15.69%(On DSR Items)
16Deduct PWD Cost Index@9.5%(On DSR Items)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail