| 1 | APPENDIX |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)( D S R5.1.2 . ) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofshaving slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinthlevel up to floor five level, excluding the cost of centering, shuttering,finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). ( D S R 5.3. ) |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform.( D S R5.9.3) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers. ( DSR5.9.5. ) |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts. ( D S R5.9.6. ) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for :Weather shade, Chajjas, corbels etc., including edges ( D S R 5.9.19) |
| 12 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 14 | Filling earth cut and conveyed from available sources in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. (modified the item 2.25 with 16.3.9) |
| 15 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 16 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20 cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete.(OBSERVEDDATABUILDING50.6. 1.4.) |
| 17 | Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20 cm or nearest available size confirming to IS 2185 part I of 1979 forSuper Structure Up to Floor 2level with thickness 20 cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete( ObservedDataBuildings50.6.1.5.) |
| 18 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 19 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster( D S R 13.9.1. ) |
| 20 | Add for Plasterdripcourse /groove in plastered surface or moulding toR.C.C. projections. ( D S R 5.30 ) |
| 21 | Pointing on stone work with cement mortar 1:3 ( 1cement:3fine sand) :( DSR13.33.1 ) |
| 22 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in all colours, shades, except White, Ivory, Rey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4(1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete. |
| 23 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 24 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).( D S R13.46.1. ) |
| 25 | Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coats on new work.(D S R 13.42.1.) |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.( D S R13.61.1 . ) |
| 27 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer , but excluding the cost of other fittings, complete all as per approved design (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size).( D S R10.11.1.) |
| 28 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes.( D S R 10.30.1.) |
| 29 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece.( D S R10.5.2 ) |
| 30 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(D S R9.48.1) |
| 31 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.( D S R10.2.) |
| 32 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes ( D S R10.16.1) |
| 33 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 34 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm). |
| 35 | Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). ( D S R 2016 21.5 ) |
| 36 | Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) ( APPROVEDOBSERVED DATABUILDINGS50.12.5.1 ) |
| 37 | Providing and fixing white vitreous china water closet squatting pan (Indian type) Orissa pattern W.C. pan of size 580x440 mm(D S R 17.13.2.) |
| 38 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. (D S R17.7.2. ) |
| 39 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White( D S R17.18.1) |
| 40 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore( D S R18.17.1 ) |
| 41 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore ( D S R18.17. 1 A ) |
| 42 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore( D S R18.18.1.) |
| 43 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (D S R18.48) |
| 44 | Providing and fixing PTMT bib cock of approved quality and colour 15 mm nominal bore, 90 mm long, weighing not less than 93 gms( D S R18.54.4. ) |
| 45 | Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid150 mm nominal size square 100 mmdiameter of the inner hinged round grating(D S R 18.58.2.1.) |
| 46 | Providing and fixing PVC pipes, fittings including fixing the pipe with claps at 1.00 metre spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20 mm dia 12Kgf/cm2 - Internal work - Exposed on wall( Observed DataBuildings50.18.7.2.1.) |
| 47 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2(ObservedDataBuildings50.18.8.2.2.) |
| 48 | Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. topslab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar1:3 (1 cement : 3 coarse sand), finished smooth with a floating coatof neat cement on walls and bed concrete etc. complete as perstandard design: Inside dimensions 455x610 mm and 45 cm deep for singlepipe line :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5( D S R19.30.1.1.) |
| 49 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall( ObservedDataBuildings50.18.7.3.2.) |
| 50 | Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2( Observed Data Buildings50.18.9.3.2.) |
| 51 | Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2(ObservedDataBuildings50.18.9.9.2. ) |
| 52 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall ( ObservedData Buildings50.18.9.17.2.) |
| 53 | Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall ( ObservedDataBuildings50.18.9.19.2.) |
| 54 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow (Observed DataBuildings 50.18.9.20.3.) |
| 55 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow(Observed Data Buildings50.18.9.20.1. ) |
| 56 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow(ObservedDataBuildings50.18.9.22.1. ) |
| 57 | Providing and fixingPVC moulded fittings /accessoriesforRigidPVC pipes ,including jointingwithPVC solvent cement-110 mmdiaDoorElbow (ObservedDataBuildings50.18.9.22.3.) |
| 58 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee(ObservedDataBuildings50.18.9.22.6.) |
| 59 | Providing andfixingPVCmoulded fittings/accessoriesfor Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl( ObservedDataBuildings 50.18.9.22.8) |
| 60 | Supplying and Fixing110 mmPVC Floor Trap (MR) |
| 61 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 0.1 mm), with wall thickness 2.0mm (0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer\"s specification and direction of Engineer-in-charge Extruded section profile size 48x40 mm |
| 62 | Providing and fixing to Door Frame 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mmwith inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). ( D S R9. 118. 1) |
| 63 | DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site (OBSERVED DATA IRRIGATION60.7.1) |
| 64 | Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately) 15 to below 25 flush capacity ( APPROVEDODLSGD 51.19.ST 2 ) |
| 65 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.GROUPB ( D S RELECTRICAL1.10.2) |
| 66 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). ( D S RELECTRICAL1.31) |
| 67 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.(D S R ELECTRICAL1.32 ) |
| 68 | Supplying and fixing PVC batten/ angle holder including connection etc. as required. ( D S RELECTRICAL1.58) |
| 69 | SUPPLY AND FIXING 1200 MM BATTEN LED LIGHT 20 WATTS WITH ALL NECESSARY FITTINGS (od15443/2021_2022) |
| 70 | Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.(ODELECTRICALS90.4.2) |
| 71 | Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)(D S RELECTRICAL1.47) |
| 72 | 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), 300mm down rod , 2 number canopies, shackele kit, Copper winding, 3 number blades and all remaining accessories including safety pin, nut bolts, washers suitable for 230V/240V single phase AC supply etc. complete as required(ODELECTRICAL90.4.5.4) |
| 73 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (D S RELECTRICAL1.25) |
| 74 | Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. ( ODELECTRICAL90.4.8 ) |
| 75 | SUPPLY AND FIXING 250 MM EXHAUST FAN WITH NECESSARY FITTINGS( od15434/2021_2022) |
| 76 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 MM( D S RELECTRICAL1.21.1) |
| 77 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25MM( D S RELECTRICAL1.21.2) |
| 78 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm (D S RELECTRICAL1.17.3) |
| 79 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm(D S RELECTRICAL1.17.12) |
| 80 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm( D S RELECTRICAL1.17.21) |
| 81 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)( D S RELECTRICAL1.27.1) |
| 82 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)( D S RELECTRICAL1.27.2) |
| 83 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(D S RELECTRICAL1.27.5) |
| 84 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch(D S RELECTRICAL1.24.1) |
| 85 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch( D S RELECTRICAL1.24.3) |
| 86 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet(D S RELECTRICAL1.24.4) |
| 87 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet(D S RELECTRICAL1.24.5 ) |
| 88 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(D S RELECTRICAL1.26) |
| 89 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door(D S RELECTRICAL2.3.3.) |
| 90 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SinglePole( D S RELECTRICAL2.10.1) |
| 91 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required (D S RELECTRICAL2.11) |
| 92 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps(D S RELECTRICAL2.12.1) |
| 93 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps(D S RELECTRICAL2.14.2.) |
| 94 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.(D S RELECTRICAL5.1. ) |
| 95 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)( D S RELECTRICAL5.9.) |
| 96 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.(D S RELECTRICAL5.17) |
| 97 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.(D S RELECTRICAL6.12) |
| 98 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required.( D S RELECTRICAL2.16) |
| 99 | SUPPLY AND FIXING WEATHER PROOF ENCLOSURE FOR FIXING METER BOARD AND ACCESSORIES IN SURFACE OR IN RECESS INCLUDING CUTTING AND MAKING GOOD THE WALL . (od15456/2021_2022) |
| 100 | SUPPLY AND FIXING 32 A ,415 V TWO WAY NEUTRAL LINKIN THE METER BOARDANDGIVINGCONNECTIONS( od15440/2021_2022) |
| 101 | SUPPLY ANDFIXING32 A Fuse holder for BStype Offset tag Fuses IN THEMETER BOARD ANDGIVINGCONNECTIONS ( od15441/2021_2022 ) |
| 102 | SUPPLY AND FIXING 25 A BOLTED OFFSETTAGTYPEFUSELINKINTHE METERBOARD(od15442/2021_2022) |