| 1 | PART \"A\" Civil Work |
| 2 | Dismantling brick tiles covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. |
| 3 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :25 mm thick |
| 4 | Brick masonry in foundation and plinth with bricks of class designation 75 in :Cement mortar 1 : 6(1 cement : 6 coarse sand) Add extrafor brick work in super structure upto third storey. |
| 5 | Grading for roof water proofing treatment with : Cementconcrete1:2 :4(1cement:2coarsesand:4gradedstoneaggregate20mmnominalsize) with water proof compound as per manufacture\"s specification. |
| 6 | Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. |
| 7 | Repairtocementplasterincementmortar 1 : 6 (1 cement : 6 fine sand) including removal of old plaster in regular shape and white or colour washing. |
| 8 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia |
| 9 | Painting exterior surface of wall with 100% acrylic exterior paint of approved brand and manufacture togive an even shade including preparation of base with sand papering, primer, putty etc complete in all respect. New work |
| 10 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect |
| 11 | Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc. complete. |
| 12 | Painting with enamel paint of approved brand and manufacture to give an even shade :One or more coats on old work. |
| 13 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 14 | Polished Blue Kota Stone flooring skirting, laid over 20mm thick base of C.M. 1:4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :For area of each slab from 901 to 2000 Sq.Cm :25mm thick slab. |
| 15 | PART \"B\" Boundary Wall |
| 16 | Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr. Including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposals of surplus excavated soil as directed with a lead in a 50 Mtr. All kind of soil. |
| 17 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 18 | Random Rubble stone masonry for foundation and plinth in Cement Sand mortar above 30CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 19 | Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with1% solution of water-proof compound including two coats of hot blown bitumen (2Kg. per Sqm) complete as per specification with glass strip 3mm thick at a distance of 1m. interval :50mm thick. |
| 20 | Brick masonry in foundation and plinth with bricks of class designation 75 in :Cement mortar 1 : 6(1 cement : 6 coarse sand) Add extrafor brick work in super structure upto third storey. |
| 21 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish:20mm thick. |
| 22 | Providing & fixing precast cement concrete coping 1 : 2 : 4 mix 50mm thick complete as per specification. |
| 23 | Providing and fixing steel gate, grating and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawingincludingcuttingweldingand fabrication with priming coat of red oxide |
| 24 | Colour washing of all shades to give an even shade including all scaffolding :New work (two or more coats) with a base coat of whiting. |
| 25 | PART \"C\"Electric Work |
| 26 | Wiring of light point/fan point / exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1kV gradeand 1.5 sq.mm FR PVC insulated unsheathed flexible earth copper conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles,18 swg M.S.box, 6 A switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. as per reccommended make Gr-2Short point (up to 3 mtr.) |
| 27 | Wiring of light point/fan point / exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1kV gradeand 1.5 sq.mm FR PVC insulated unsheathed flexible earth copper conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles,18 swg M.S.box, 6 A switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. as per reccommended make Gr-2Medium point (up to 6 mtr.) |
| 28 | Wiring of light point/fan point / exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1kV gradeand 1.5 sq.mm FR PVC insulated unsheathed flexible earth copper conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles,18 swg M.S.box, 6 A switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. as per reccommended make Gr-2Long point(up to 10 mtr..) |
| 29 | Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) ofapproved makein surface / recessed ISI marked Medium duty PVC conduit & it\"s accessories, 18 SWG M.S.box, 6 Aswitch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. as per reccommended make Gr-2On board |
| 30 | Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) ofapproved makein surface / recessed ISI marked Medium duty PVC conduit & it\"s accessories, 18 SWG M.S.box, 6 Aswitch, 6 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. as per reccommended make Gr-2Long point(up to 10 mtr..) |
| 31 | Supplying and fixing of power plug point accessories on 18 SWG metal box of size 175 x 100 x 60 mm. on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. Switch and socket outlet, making connection , as per reccommended make. |
| 32 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. as per reccommended make2 x 2.5 sq. mm. + 1x1.5sqmm |
| 33 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. as per reccommended make2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 34 | P&F Recessed/ Surface mounting heavy duty horizontal type sheet steel Distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar, conforming to IS13032 & IS8623 including making internal DBterminations with copper lugs , testing etc. as required. as per reccommended make Gr-2 Double door(single phase) 12 Way |
| 35 | P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. as per reccommended make Gr-2Single pole MCB 6 A to 32 A rating |
| 36 | P&F 240/415 V MCB of breaking capacity not less than 10 KA (B/C/D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections with lugs, testing etc. as required. as per reccommended make Gr-2Double pole MCB 40 A to 63 A rating |
| 37 | S & F following sizes (dia.) of ISI marked mediun duty PVC conduit along with accessories in surface/recessed using saddles,clamps,fasteners as required including cutting the wall and making good the same as required as per recommendeed makes enclose G220mm |
| 38 | S & F following sizes (dia.) of ISI marked mediun duty PVC conduit along with accessories in surface/recessed using saddles,clamps,fasteners as required including cutting the wall and making good the same as required as per recommendeed makes enclose G225mm |
| 39 | P &F PVC sheet of size 75 mm dia. Including screws, cup washer as required. |
| 40 | P & F ISI markedding dong/musical chime bell including making connection testing etc. as required. |
| 41 | P & F ISI markedflush type 120/280 watt rotary step 2 module(socket Type) fan regulator including making connection testing etc. as required. as per reccommended make. |
| 42 | Making of hole in wall of required size for housing exhaust fan and making good the same, with cement plaster as required of following size: Up to 457 mm size |
| 43 | P & F 1.6 mm thick M.S. Recessed fan box, hexagonal/ round of size 100 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . |
| 44 | P&F gravity louver shutter of superior quality made out of aluminium sheet with enamel paint including cost of nuts , bolts etc as reqd |
| 45 | P & F strip type fluorscent tube fitting fabricated from (CRCA sheet and finished with powder coating/ stove enamelled paint) / (extruded non corrosive UV resist EP channel) complete with accessories (Low Loss Copper Choke, Starter, Starter Seat) Electronic Chocke with terminal block duly prewired with copper conductor including making connection, testing etc. as required. (Without tube). Gr-11 x 28 Watts with EB |
| 46 | P & F IP-54 protected Bulkhead luminaire suitable for 100 Watt GLS lamp made out from Die cast alluminium alloy body, suitably gasketed frosted glass cover including making connection testing etc. as required. As per recommended make Gr-2 |
| 47 | P & F double ball bearing capacitor start ceilingfan of approved make complete without regulator and other accessories as required. Gr-1 1200 mm sweep |
| 48 | P & F Fluorscent tube rod in existing fixtures as required. T5 lamp 28 watt. |
| 49 | P & F IP-43 protected street light luminaire on existing bracket suitable for FTL,made out from CRCA sheet steel finished with stove enamelled paint,having deep drawn aluminium alloy canopy reflector cum control gear tray, clear ribbed acrylic diffuser held with synthetic gasket, with all necessaryaccessories copper wound ballast, capacitor, starter, holder prewired with pvc insulated copper conductor including making connection testing etc. as required.(without tube) as per reccommended make Gr-11 X 36 Watt |
| 50 | P & F of loose wire boxes with made out with sheet steel box as per dimension of DB |
| 51 | S & F of Street light bracket made out from following size of \" B \"class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required.40 mm OD |
| 52 | P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 10.0 Sq.mm x 2 Core |
| 53 | Mainteneance free Gel Earthing with copper Earth ectrode of size50 mm x 2 m by embodying 2.5 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and c.c finished chamber coverd with hinged type with locking arraangment C.I cover ,C.I frame of size 300mm x 300mm complete with filling of ash gel compound (dharken or equivelent approved make), testing of earth resistance as required.with Strip in Pipe Technology with 80 - 100 micron GI Coating GI pipe 2000 mm long ,50 /25 mm long, 50/25mm, Terminal 12mm GI strip. |
| 54 | S & Laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required.6 SWG GI Wire |
| 55 | P & F two pin energy efficient compact flourscent lamp in existing holder/fixture as req. 13/18Watt |