| 1 | Walls and ceiling with antibacterial paint :- The Pre fabricated MOT panels (wall & ceiling) made out 50 mm Puff panel, both side 0.8 mm thick EGP sheet, Puff density 40 kg/M3 with proper support and locking. The inner surface walls will be fixed to the bricks wall with essential supports. There will be minimum possible cavity gap in between the solid and steel walls with filling of all joints & cavities with expory filler and sanded flush to provide a seamless finish including one primer an three coats of water base antibacterial paint & antifungal self sterile paint equivalent to aluminium dry film thickness of 300 microns and will variable to suit the architect\"s layout for the flush mounting of equivalentas direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 2 | Aluminium coving :- Installtion of pre powder coated aluminiumcoving structure, for removing of all sharp corner as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 3 | Storage Unit :- Storage unit size of (1665x800x350) mm made of 1.5 mm GPSP 120 GSM Zinc coated steel complete with glass doors & all accessories etcas direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 4 | Laminar Flow Air System with Perforated Grill :- Planair ceiling system with laminar airflow with aluminium powder coated perforated diffuser, Plenum unit holding structure & Top plenum are conforming to DIN 4799 standards for the air distribution system complete with minipleet HEPA Filters (Thermodynemake) efficiency 99.97 down to 0.3 mm (Plenum Size 2000mmx2000mm) as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 5 | Operation Theatre Control Panel :- Membrane type Operation Theatre Control Panel (6 service tiles) mounted flush in the theatre wall with Distribution Board complete with all accessories etc as direction of the Engineer in Charge including carriage of materials within all leads and lifts.1.Day time clock2. Elapsed Time clock3. Temperature & Humidity Display4. Lighting control5. Medical gas alarm 6. Hands free telephone 7. Hepa filter status |
| 6 | LED Type X-Ray Viewing Screen :- Providing, fixing, supply, installation, testing and commisioning of LED viewing screen size (948 x 640 x 110) mmas direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 7 | LED Type Clean Room Light :- Recess mounted seales IP54 protocol, non - hygroscopic Dimmable LED Peripheral light for clean room application as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 8 | Operating List Board :- Magnetic list board of size 948x648x50mm complete with all accessories.as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 9 | Single Movable Arm Pendant :- Single arm movable pendant with 1000 mm long arm having weight carrying capacity of more than 100 Kg, console 600 mm long, six electrical socket 5/15 ampere, monitor shelf and gas outlet (6 nos) as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 10 | Electrical Wiring (Inside OT) :- Laying conduits & electrical wiring with FRLS wire within operation theatre for control panel light, X-Ray view panels pendants OT Light wall sockets and terminate to distribution panel near to theatre, including with Electrical Modular switch boxes, Modular Switch sockets as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 11 | Pressure Relief Dampers :- The PRD will be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper will be strategically placed. Enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areas, each PRD having multi 304 graded stainless steel blades for maintaining the positive pressure inside the operation theatre complete with all accessories etc as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 12 | Air Handling Unit (A.H.U.): - Floor mounted Double skin air handling unit constructed out of 24 gauge GI precoated sheet as outer skin and Plain 24 gauge GI sheet as Inner skin with 40mm thick PUFF section in between and comprising of following sections:1. Prefilter section with 10 Micron filters2. Cooling/Heating section with Dual Circuit 6 Row DX. cooling coil3. Blower section with backward DIDW blower, drive set & pulleys4. Fine Filter section 5 Micron filters at discharge sideOther accessories like Mixing box with fresh air module and return air damper, Humidity Controller, Common base frame with Vibration isolators pads, Suitable inspection doors for Filters, coil & blower sections are provided.Capacity 3000CFM@125mm WG SP, 5.5 TR x 2 = 11TRMinimum 30 air changes. Note : Complete Package with 22 gauge Alluminium Ducting and all Accessories e. g. L&T/Schnider and Minilec make Electrical Components used in Distribution Paneland as directed by the Engineer in Charge including carriage of materials in all leads and lifts. |
| 13 | View Window (view window with two prel) :- View eindow with two paraller toughened glasses and powder coated aluminium extrusion frame (glass thickness not less than 5 mm) size 1000mmx1200mm as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 14 | Two Bay Scrub Station :- Supply, installation, testing and commissioning of two bay scrub station fabricated out of 1.2 mm nominal thickness SS 304 stainless steel, with solid mineral surface, having minimum physical dimension not less than 1600mm (width) x 1380mm (height) x 580mm (depth)as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 15 | Three Bay Scrub Station :- Supply, installation, testing and commissioning of three bay scrub station fabricated out of 1.2 mm nominal thickness SS 304 stainless steel, with solid mineral surface, having minimum physical dimension not less than 2100mm (width) x 1380mm (height) x 580mm (depth) as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 16 | HERMITICALLY SEALED SLIDING DOOR :- Door Size 1500 mm x 2100 mm with vision panels, 300mm x 300mm. The minimum width of the door should be 1500mm to allow smooth movement of patient in the operating room.To maintain sterility and the correct air pressure in the room, all doors should be sliding hermetically sealing type. Track system and door blade guide system. Door leaf strength of leaf core: 40mm (33mm tubular chipboard (core) + 3mmMDF (medium density fibreboard) on both side + 0.8mm HPL (High Pressure Laminate) on both side). Circumferential profile: Anodized aluminium profile, circumferential 56mm, V-shaped in the bottom area towards door lead on ground lobes. Surface: 0.8mm HPL-laminate on 3mm MDF board as carrier material; depending on the chosen material a free passage of 1.15m or more may require a seam in the laminate. Sealing: Rubber gaskets embedded in the door leaves press against the frame and the door, providing a hermetic sealing of the door. Rail system guide rail: Anodized aluminium profile with two countersunk slots at 42° for carrying wheel position in closed condition. Carrying Wheels: Ball bearing with duroplastic rolls. Covering: Rounded covering of extruded anodized aluminium. Ground Rail: Duroplastic lead lobes on bottom running rail. Operation Handle: Bilateral (inside/ outside) stainless steel lever arm handle with integrated return spring to neutral position. Frame HPL-system frame: HPL- coated embrasure board with circumferential aluminium corner protection profiles for arbitrary wall strengths. Closed frame steel: Closed steel frame with additional aluminium corner protection profiles (for sealing the operation side of the door). Closed frame stainless steel: Stainless Steel frame, steel grade 1.4301, polished 240 grains, with additional stainless steel corner profiles (for sealing the operation side of the doors). Window: Integrated 300mm x 300mm window, mounted flush with the adjacent area of the leaf and as directed by the Engineer in Charge including carriage of materials in all leads and lifts. Size W= 900mm, H= 2100mm |
| 17 | Size W= 1200mm, H= 2100mm |
| 18 | Size W= 1500mm, H= 2100mm |
| 19 | Size W= 1650mm, H= 2100mm |
| 20 | Antistatic Vinyl Flooring (OT, Scrub Room, Sterlization area and OT Corridor) :- Supply and installation of seamless conductive flooring system, 2.00 mm thick having ESD / EMI (conductive) protection charateristics with perfectly curved flush covings, all joints welded properly as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 21 | Self Levelling Compound (OT, Scrub Room, Sterlization area and OT Corridor) :- Supply and installation of Cement based self levelling with Primer in average thickness of 3 mm as per Endura / Indiana Specification (Make-Endura / Indiana or equivalent) as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 22 | LED OT Lights :- Luminescence shadow less lamp adopts light sources different positions for focus to elliminate shadows of differents parts of the medical workers.Operational requirements double doom light intensity at 1 mt. shall be 160000+160000 lux for each dome at 1 mt.No. of LED ; 80-120 LED in each dome, 60 LEDs in each dome colour temperature adjustable in four steps from 3500-4000-4500-5000K.They should have 3 colour LEDs for excellent tissue differentiation during surgery.Thereby reducing strain and fatigue on the surgeon\"s eyes when operating for long hours. LED technology minimum 40000 hrs lamp life and as directed by the Engineer in charge including carriage of materials in all leads and lifts. (Make-Staan or equivalent) |
| 23 | Steel work welded in built up sections including hollow section, trusses and framed work, including cutting hoisting fixing in position and applying a priming coat of red lead paint including carriage of materials within all leads and lifts :-In beams, joists, channels, angles, tees, flat with connecting plates, angles cleats, as in main and cross beams, hips, jack rafters, purlins connected to common rafter and the like as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 24 | Providing and fixing 0.60mm thick prepainted steel sheet Tata Durashine or equivelant in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5microns over 5microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia meter with prepainted limpet and rubber washers complete with all accesoriees as required as per the direction of Engineer-in-charge including carriage of materials upto all leads and lifts. |
| 25 | Providing and fixing M.S. BP Sheet 1.66mm to 2mm thick in eaves board/ facia/ soffits/ ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in charge (Base members of steel work shall be measured and paid separtely) as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 26 | Providing and fixing 15 cm. wide 45 cm. overall semicircular plain G.I. sheet gutter with iron brackets 40 x 3 mm size bolts and nuts and washers etc. including making necessary conections with rain water pipe complete as per design completeas direction of the Engineer in Charge including carriage of materials within all leads and lifts. :- 0.63 mm thick sheet. |
| 27 | Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint to give an even shade including cleaning the surface of dirt, dust and other foreign matter, sand papering and stopping Withenamel paint other than white paint as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 28 | Providing and fixing M.S. welded mesh 25mm X 25mm X 2mm thick as per approveddesigncomplete by welding with electrical plant complete including applyingpriming coat of red lead paint as per HP.PWD. Specification 1990 Volume-I and including carriage of materials upto all leads and liftsby mechanical means and manual labour and as direction of the Engineer in Charge including carriage of materials within all leads and lifts. |
| 29 | Conditions:-i)Rates should be quoted for all heights including all leads and lifts for internal and external works. Ii.)Paint, emulsion, distemper etc. should be of 1st class quality and it should also be got approved from Eigineer- in- charge before use. iii.)Sample of all the material to be used on work shall be got approved from the Engineer-in-charge in advance before actual use on workand any or all of the material which are available as per Indian standard in the market should confirmto bureauof indian standards. |