Haryana Police Housing Corporation Limited has published Construction Of Male Barracks And Convict In Distt. Jail, Panipat Construction Of Male Barracks And Convict In Distt. Jail, Panipat. Submission Date for this Tender is 19-08-2021. Barrack Tenders in Panipat Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

28759168
Construction Of Male Barracks And Convict In Distt. Jail, Panipat Construction Of Male Barracks And Convict In Distt. Jail, Panipat
Open Tender
Indian
Haryana
Panipat
19-08-2021

Tender Details

Construction Of Male Barracks And Convict In Distt. Jail, Panipat Construction Of Male Barracks And Convict In Distt. Jail, Panipat

Key Value

Document Fees
INR 20000 /-
EMD
INR 1420000.0 /-
Tender Value
INR 7.10 Crore /-

BOQ Items

Name of Work: Construction of Male Barracks and convict in Distt. Jail Panipat
Sl. No. Item Description
1CIVIL (HSR PART)
2Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead up to 50 m and lift up to 1.5 m (HSR2021/4.8) 4.8.1) All kinds of soil
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. (HSR2021/ 4.32)
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: (HSR 2021/6.1) 6.1.1) 1 : 1 ½: 3 ( 1 Cement: 1 ½ coarse sand (zone-Ill) : 3 cum graded stone aggregate 20 mm nominal size)
56.1.6) 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size)
6Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 2021/ 6.14) 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
7Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : (HSR 2021/ 6.15) 6.15.1) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3graded stone aggregate 20 mm nominal size)
8Reinforced cement concrete work in beams, suspended floors,roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size) (HSR 2021/6.16)
9Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1 ½ coarse sand(zone-111) : 3 graded stone aggregate 20mm nominal size). (HSR 2021/ 6.21)
10Centering and shuttering including strutting, propping etc. and removal of form for (HSR 2021/ 6.30) 6.30.1) Foundations, footings, bases of columns, etc. for mass concrete
116.30.3) Suspended floors, roofs, landings, balconies
126.30.5) Lintels, beams, plinth beams, girders, bressumersand cantilevers
13Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement (HSR 2021/6.33) 6.33.6) Thermo-Mechanically Treated bars of grade Fe-500D or more.
14Providing and laying damp-proof course with cement concrete 1: 1.5:3 (1 cement : 1.5 coarse sand (zone-Ill): 3 graded stone aggregate 20mm nominal size) (HSR 2021/6.9) 6.9.2) 40 mm thick
15Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 confonning to IS: 2222 in superstructure in foundation and plinth in cement mortar 1 :6 (1 cement : 6 coarse sand)With non-modular bricks (HSR 2021 / 7.23.1) (Derived Rate)
16Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 confonning to IS: 2222 in superstructure above plinth level up to floor four level in cement mortar 1 :6 (1 cement : 6 coarse sand)With non-modular bricks (HSR 2021 / 7.23.1)
17Half brick masonry with common burnt clay non-modular bricks of class designation 10.00 in superstr-ucture above plinth level up to floor IV level. (HSR 2021/ 7.28) 7.28.2) Cement mortar 1 :4 ( 1 cement :4 coarse sand)
18Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete (HSR2021/ 8.29)
19Painting top of roofs with bitumen of approved quality @ 17kg per 1O sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete (HSR 9.10) 9.10.1) With residual type petroleum bitumen of grade VG -1 O
2010 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1: 3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: (HSR 2021/ 9.11) 9.11.1) With common burnt clay non-modular brick tile of class sqm designation 12.50
21Providing gola 75x75 mm in cement concrete 1: 2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : (HSR2021/ 9.17) 9.17.1) In 75x75 mm deep chase
22Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete (HSR 2021/ 9.18)
23Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (HSR 2021/9.57) 9.57.2) 110 mm diameter
24Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion.(HSR 2021/ 9.58) 9.58.5) Bend 87.5° 9.58.5.2) 110 mm bend
25Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : (HSR2021/ 9.62) 9.62.1) 100 mm diameter
26Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 2021/10.1)
27Providing and laying of conglomerate floor 40mm thick cement concrete topping 1 :2:4 (HSR 2021/10.8)
28Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand) : (HSR 2021/10.37) 10.37.1) 25 mm thick
29Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (HSR2021/ 10.38)
30Providing and laying Baroda Green marble stone 17mm and above thickflooring included matching the grains of marble slab in any pattern as specified laid over 12mm thick cement sand mortar 1 :3 and jointed with white slurry mixed with pigment to match the shade of marble including rubbing and polishing. The rates are for all heights / storey. The sample shall be got approved from Engineer In Charge. (HSR 2021/10.48)
31Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size not less than 300 x 450mm as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3 coarse sand) and jointing with grey cement slurry@ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.. (HSR 2021/10.62)
32Providing and fixing P .V.C . strips, 40mm wide in floors. (HSR2021/ 10.87) 10.87.1) 4 mm thick
33Cement Concrete 1 :8:16 Flooring (HSR 2021/ 10.100) 10.100.2) Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth.
346 mm cement plaster 1 :3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. (HSR 2021/11.2)
351 O mm thick cement plaster (HSR 2021/ 11.4) 11.4.2) 1 :3 (1 cement: 3 fine sand)
3612 mm cement plaster of mix (HSR 2021/ 11.5) 11.5.3) 1 :4 (1 cement: 4 fine sand)
3711.5.4) 1 :6 (1 cement: 6 fine sand)
3815 mm cement plaster on the rough side of single or half brick wall of mix (HSR2021/ 11.6) 11.6.2) 1 :6 (1 cement: 6 fine sand)
39Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 2021/11.58)
40Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: (HSR 2021/ 11.64) 11.64.1) New work (two or more coats) over and including water thinnable priming coat with cement primer
41Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: (HSR 2021/11.67) 11.67.1) Water thinnable cement primer
42Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade (HSR2021/ 11.71) 11.71.1) Two or more coats on new work
43Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete (HSR 2021/11.76)
44Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 2021/ 11.77)
45Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 2021 / 11.78)
46Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (HSR2021/ 12.37) 12.37.1) 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws
4712.37.2) 30 mm thick including ISi marked Stainless Steel butt hinges with necessary screws
48Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. (HSR 2021/12.52)
49Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (HSR 2021/12.98) 12.98.2) 250x16 mm
50Providing and fixing aluminium tower bolts, ISi marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed torequired colour or shade, with necessary screws etc. complete (HSR 2021 / 12.99)12.99.4) 150x10 mm
51Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (HSR2021 / 12.102) 12.102.1) 125 mm
52Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (HSR2021/13.1.) 13.1.1) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size).
53Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge (HSR2021/ 13.2)
54Supply & fixing Windows frames (Chowkhats) including mullions consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (Base steel as per IS 513) with zinc of 120 gm/sqm & Powder coated with pure Polyester powder up to 50 microns (as per approved colour), 3 Nos. 100mm butt - hinges 2mm thick, 6 Nos. 1.2mm thick CRCA electroplated stiffner, 6 Nos. M.S hold fast with split and tail welded to stiffner plate 200mm long, receiver for aldrop, weld less corner assembly with brackets & screws, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.6mm of approved shade, fixed in position including the cost of cement concrete for 1 :2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire satisfaction of Engineer-in-charge. (HSR 2021/13.21) 13.21.1) Door Frame of size 80mm x 50mm with 37mm wide single rebate metre for 35mm door shutter
55Dressing bed and preparation of sub grade for lining by mechanical/ mannual means (HSR 14.1)
56TOTAL CIVIL (HSR PART)
57PH (HSR PART)
58Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (HSR 2021/4.14) 4.14.1) All kinds of soil.
59Drilling and tapping cast iron pipe lines of all diameters and screwing in ferrule and connections - (HSR 2021/20.24) 20.24.1) Ferrule size 10 mm
60Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. (HSR 2021/20.26) 20.26.2) 22.86 cm thick wall
61Providing and screwing in brass/Gun Metal ferrules drilling and tapping A.C. /PVC pipe lines of all diameters and connections including cost of M.S. Clamp (Heavy) with welded socket/Saddle piece including carriage, loading, unloading etc. complete in all respects to the satisfaction of Engineer-in- Charge. (Excavation will be paid separately). (HSR 2021/20.55) 20.55.4) 10mm i/d ferrule on 80mm i/d pipes
62Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benching 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside with heavy duty SFRC cover & frame as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 2021/ 21.84) 21.84.2) Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern SFRC with heavy duty
63Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1 :3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in allespects to the satisfaction to the Engineer-in-charge. (HSR 2021 / 21.93) 21.93.2) Type:- Extra Heavy Duty Set (EHD-20) 560MM Clear Opening
64Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required (HSR 2021/ 22.10) 22.10.2) Kitchen sink without drain board 22.10.2.1) 610x510 mm bowl depth 200 mm
65Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (HSR 2021/22.14) 22.14.1) Semi rigid pipe 22.14.1.1) 32 mm dia
66Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required (HSR 2021/22.26) 22.26.1) Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
67Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. (HSR 2021/ 22.35)
68Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1 :3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1 :4 (1 cement : 4 coarse sand) : (HSR 2021/22.81) 22.81.2) 75 mm dia
69Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (HSR 2021/ 22.85) 22.85.2) 20 mm nominal outer dia Pipes
7022.85.3) 25 mm nominal outer dia Pipes
7122.85.4) 32 mm nominal outer dia Pipes
7222.85.5) 40 mm nominal outer dia Pipes
73Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (HSR 2021/22.87) 22.87.2) 20 mm nominal outer dia Pipes
7422.87.3) 25 mm nominal outer dia Pipes
7522.87.4) 32 mm nominal outer dia Pipes
7622.87.5) 40 mm nominal outer dia Pipes
77Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall (HSR 2021/ 22.88) 22.88.2) 20 mm dia nominal bore
7822.88.3) 25 mm dia nominal bore
7922.88.4) 32 mm dia nominal bore
8022.88.5) 50 mm dia nominal bore
81Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work (HSR 2021/ 22.91) 22.91.2) 20 mm dia nominal bore
8222.91.3) 25 mm dia nominal bore
8322.91.4) 32 mm dia nominal bore
8422.91.5) 50 mm dia nominal bore
85Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) (HSR 2021/ 22.94) 22.94.2) 20 mm nominal bore
8622.94.3) 25 mm nominal bore
8722.94.4) 32 mm nominal bore
8822.94.5) 40 mm nominal bore
89Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): (HSR 2021/22.98) 22.98.2) 20 mm nominal bore
9022.98.3) 25 mm nominal bore
9122.98.4) 32 mm nominal bore
92Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (HSR2021/ 22.103) 22.103.2) 20 mm nominal bore
93Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (HSR 2021/ 22.104) 22.104.1) 15 mm nominal bore
94Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (HSR 2021/ 22.105) 22.105.1) 15 mm nominal bore
95Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (HSR 2021/22.107) 22.107.1) 15 mm nominal bore
96Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR2021/ 22.109)
97Providing and fixing PTMT, push cock of approved quality and colour. (HSR 2021/22.114) 22.114.1) 15 mm nominal bore, 96 mm long, weighing not less than 75 gms
98Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1: 1 (1 cement : 1 fine sand) including testing of joints etc. complete: (HSR 2021/ 22.163) 22.163.2) 150 mm diameter
99Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: (HSR 2021/ 22.166) 22.166.1) 100x100 mm size P type 22.166.1.1) With common burnt clay non-modular bricks of class designation 7 .5
100Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 2021/ 22.181)
101Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. (HSR 2021/ 22.221) 22.221.2) Size 550 mm x 400 mm x 815 mm
102TOTAL PH (HSR PART)
103CIVIL (NS PART)
104Earth Filling with the earth brought from outside the campus irrespective of any lead, including laying in 15cm layers, watering, compacting and consolidating complete in all respect & to the full satisfaction of engineer in charge (NS)
105Finishing of the laid cement concrete with vacuum dewatering system, surface vibrator and fine trowel complete in all respect (Trimix) (NS)
106Providing 50mm x 4mm size groove as expansion joint in concrete pavement by mechanical cutter, complete in all respect (NS)
107P/ Fixing 4mm thick ACP sheet for exchaust fan with screws &rawl plug complete in all respect (NS)
108Extra labour for making bhalla 16/20 mm. square bar. Fixed on boundary wall grill complete in all respect.
109Extra labour for laying of design on top of boundary wall pillers complete in all respect.
110Extra for making hole 20x20mm diagonally in shape by machanical means placing the same and welding fromk top to bottom
111TOTAL CIVIL (NS PART)
112PH (NS PART)
113Providing & fixingSWR PVC pipe classic type ‘B’ and specials ISI marked and rubber ring with solvent complete in all respect (NS)
114a) 90mm dia pipe
115Special for 90 mm dia pipe i) Vent Cowel with Jali
116ii) Pipe Clip/ Clamp
117iii) Coupler/ Socket
118iv) Bend with Door
119v) Single T
120vi) Single T with Door
121vii) Single Y with Door
122viii) Nanhi Trap with Jali (110x110mm)
123b)110mm dia pipe
124Special for 110 mm dia pipe i) Vent Cowel with Jali
125ii) Pipe Clip/ Clamp
126iii) Coupler/ Socket
127iv) Bend with Door
128v) Single T
129vi) Single T with Door
130vii) Single Y with Door
131viii) P-Trap (DS) 110x110mm
132Providing and fixing C.P. jali with frame complete in all respect
133Providing and fixing CP Brass flange complete
134P/F EWC wall hung / floor mounted WC sheet of stainless steel as per ISO 9001:2008 certified including flush cock, seat cover, jet spray complete in all respect
135Supply and fixing S.S. urinal complete in all respect
136P/F in position double bowl stainless steel sink having size 1420x570x250mm complete in all respect
137Providing & fixing stainless steel WC pan of approved make having size 585x480mm flushing made from ISI 304 (1818) grade having glossy finished with 100mm outlet complete in all respect
138TOTAL PH (NS PART)
139BOUNDARY WALL (HSR PART)
140Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead up to 50 m and lift up to 1.5 m (HSR2021/4.8) 4.8.1) All kinds of soil
141Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: (HSR 2021/6.1) 6.1.1) 1 : 1 ½: 3 ( 1 Cement: 1 ½ coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size)
1426.1.6) 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size)
1436.1.8) 1:5:10 (1 cement : 5 fine sand : 10 graded stone cum aggregate 40 mm nominal size)
144Providing and laying damp-proof course with cement concrete 1: 1.5:3 (1 cement : 1.5 coarse sand (zone-Ill): 3 graded stone aggregate 20mm nominal size) (HSR 2021/6.9) 6.9.2) 40 mm thick
145Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 2021/ 6.14) 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
146Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 confonning to IS: 2222 in superstructure in foundation and plinth in cement mortar 1 :6 (1 cement : 6 coarse sand)With non-modular bricks (HSR 2021 / 7.23.1) (Derived Rate)
147Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 confonning to IS: 2222 in superstructure above plinth level up to floor four level in cement mortar 1 :6 (1 cement : 6 coarse sand)With non-modular bricks (HSR 2021 / 7.23.1)
148Extra for making tapered surface of brick masonry. (HSR 2021/ 7.59)
14912 mm cement plaster of mix (HSR 2021/ 11.5) 11.5.3) 1 :4 (1 cement: 4 fine sand)
150Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 2021/11.58)
151Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: (HSR 2021/11.67) 11.67.1) Water thinnable cement primer
152Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade (HSR2021/ 11.71) 11.71.1) Two or more coats on new work
153Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge (HSR2021/ 13.2)
154Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR 16.53)
155TOTAL BOUNDARY WALL PART
156E.I. HSR PART Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.(HSR 23.3.6.1) 1 run of Size 1.50 Sqmm(1/1.40mm)
157COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT as per HSR 23.4. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. (HSR 23.4.1.) iii) Group C
158Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required as per HSR 23.4.4. iii) Group C
159Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling, including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required as per HSR 23.4.5. iii) Group C
160Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. as per HSR 23.7.6. ii) PVC pipe of 25 mm dia.
161iv) PVC pipe of 40 mm dia.
162Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cmlong M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. As per HSR 23.8.4.
163Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. As per HSR 23.8.11 vii) step type Fan Regulator 2 modules 300 watt
164ix) TV Socket outlet modular type
165x) Blanking plate
166Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. as per HSR 23.22.4. vii)TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)
167xi)Vertical TPN DB Double Door 8 way ( 8 incoming 3phase*8 outgoing 23.22.4.12 HSR
168Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. as per HSR 23.22.1. (ix) 4 pole MCCB 6 amp to 100 amp , 25 KA
169Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- i) 6 amp. to 32 amp Single Pole 23.22.5 HSR
170vi)40 amp to 63 amp. MCB"s TRIPLE POLE
171vii)40 amp to 63 amp. MCB"s FOUR POLE
172Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- as per HSR 23.23.1. (i)Size 15 mm dia
173EARTHING AND LIGHTENING ARRESTOR as per HSR 24.1. iii) Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
174v) Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode.
175vi)Supplying and laying 25mm x 3mm G.I. strip at 0.5 metre below ground as strip earth electrode including soldering etc. as required.
176Supply and erection of GI bracket made of 32 mm dia medium class GI pipe, having 15 deg angle from horizontal, suitable for fixing on top of Street Light pole( HSR 24.4.2) iv)150 cm long, with 30 cm high suitable size pole cap
177Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge as per HSR 20.71. ii) 48" (1200mm)
178Total E.I HSR Part
179E.I NS
180S/E of 45 watt LED street light made up of pressure die cast aluminium housing, IP66 with 2/4 Hrs backup i/c cost of material & labour required to complete the job in all respect & making necessary connections.
181S/E of energy efficientLED 6000K 1" x 1" luminaire complete with diffuser, energy efficient electronic driver and other material require to complete the job i/c fixing the same on the ceiling ith required material & making necessary connections etc. i) LED 15/18 W square fitting surface mounting
182Supply and erection of metal exhaust fan, double ball bearing suitable for single phase A.C. 230 Volts, 50 HZ capacitor ,900 RPM (Heavy duty) complete with mounting ring, blade, fixing and making necessary connections etc.as per approved brands) i) Size 300 mm sweep"
183Supply and erection of aluminium anodized louver shutter for exhaust fan (Thickness of frame 1.00 mm & blade thickness 0.80 mm) including all labour and other petty material required to complete the job. (Canon, National make) i) Size 300 mm sweep
184S/E of 250 mm sweep AC Ex fan PVC body with louver shutter suitable for single phase CA 230 volt 50 hz supply 900 RPM and capacitor run complete in all respect . As per brand list
185Supply & erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . (i) 50 Sq. mm 4 Core Cable .(Armoured)
186(ii)16 Sq. mm 4 Core Cable (Armoured)
187Supply and erection of PVCpipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. (i) PVCpipe 80 mm dia.
188Supply and erection of co-axial TV cable (RG-6) with electrolytic grade solid bare copper conductor, gas injected physical foamed polythylene insulation, screened with laminated aluminium tape & aluminium alloy wire braided, jelly flooded & UV grade PVC jacketed in existing pipe, complete in all respect including making necessary connections and labour etc.
189Supply, Installation, testing & commissioning of Full HD 43” Full HD Monitorincluding cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having minimum technical specifications and above as under:- Resolution : 1920*1080 (FHD) with minimum 350 nits, RS 232 control port, Backlight : LED, Response time: 5ms, Input : VGA,HDMI, Audio , Output: Speaker * 1, Consumption : 58W, Industrial Level DID LCD Panel, Suitable for extensive 7*24 Hours Continuous Works, Built in Speaker , Certificate : CE,CB,FCC SAMSUNG/IBM/LG/PANASONIC/SONY
190S/E of water cooler of stainless steel body with 150 ltr storage & cooling capacity (make -USHA) ) with all petty material. MAKE AS PER BRAND LIST
191S/E of water cooler of 50 LtrRO Water purification systemwith all petty material MAKE AS PER BRAND LIST
192Total E.I. (NS items)
193Smart Integrated Solution (Access control, Video Surveillance, Network Broad casting, Announcement, RFID/ Biometric etc.) HSR PART Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc. at both ends (Up to length of one metre):- as per HSR 23.23.1. (i)Size 15 mm dia
194Total HSR Part (Smart Integrated Solution (Access control, Video Surveillance, Network Broad casting, Announcement, RFID/ Biometric etc.)
195NS Item Supply, installation, splicing, testing & commissioning of 12 core armoured single mode optical fibre cable with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work including cost of testing through OTDR Machine.(DILING/FINOLEX/DIGILINK/SIEMON/BELKIN)
196Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
197S/E of PVC insulated multi core copper conductor cable (unarmoured) 1100 volts grade (round) in existing pole/ pipe, complete in all respect including making necessary connections. i) Size 2.50 Sqmm x 3 core
198Supply, Installation, testing & commissioning of Rack IP66 6U wall mount rack 400mm deep with front door glass consisting of power distribution 5 amp., mounting hardware, cable manager steel loop-horizontal, fan without tray & pole mounting kit etc. with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
199S/E of Plain HDPE pipe for optical fibre cable as per IS 4984-1995 laid 1 mtr. below ground level including diging and refilling of earth including cost of suitable size socket / cuppler for HDPE pipe, complete in all respect upto the entire satisfaction of Engineer-incharge of the work. (i)HDPE pipe 50 mm outer dia. (ISI)
200Digging of trench for HDPE pipe and fibre optic cable, 4 mtr below ground level with trenchless Horizontal directional drilling machine pipe pulling (HDD) machine complete in all respect.
201Supply, installation, testing and commissioning of 8-Port PoE Switch Layer 2 - Rack Mountable PoE Gigabit Ethernet standalone chassis, provides 8 RJ-45 10/100/1000 BaseT, 2 SFP/RJ-45 10/100/1000 BaseT or 100/1000 BaseX combo with AC power supply, option for stacking module, communication of the cameras to the NVR with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
202Supply, installation, testing and commissioning of1GB 24 Port PoE Layer 2 Switch With 4 Nos of SFP Slots with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
203Supply, installation, testing and commissioning of HDMI EXTENDERHDMI extender supports 1080P HD, HD Audio, 3D; 20~60KHz wide Frequency, IR remote control(IR Signal input to connect with IR receiver extension cable. HDMI Single cable transmission:It extends HDMI 1080P AV signal to at least 60M by cat6 or higher level cables with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
204Supply, installation, testing and commissioningof HDMI CABLE 1MTR Category 2 Certified - High-Speed 10.2 gbps / 340 MHz (Supports up to 240hz Refresh Rates and 48-Bit Deep Color) Supports all new HDMI advanced features such as 3D, audio return channel, ethernet, dolby trueHD and DTS-HD master audioTM,Fully compatible with all blu ray players, Supports resolution 720p, 1080i, 1080p and beyond,Fully shielded heavy duty premium grade cable with soft PVC jacket.,Full metal jacket connector provides strength, durability and prevents with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of theWork.
205Supply, Installation, testing & commissioning of Cat 6 Armoured Cable with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
206Supply, installation, testing and commissioning of 12 core LIU (light interface unit) with Box for OFC connectivity with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
207Supply, installation, testing and commissioning ofSingle mode SC Pigtailwith all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
208Supply, installation, testing and commissioning ofSingle core LC Fibre Patch Cordwith all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
209Supply, installation, testing and commissioning of1-port mini-GBIC LX Single-mode Fiber Transceiver (up to 10km, support 3.3V power)with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
210Supply, installation, testing and commissioning of HDMI SPLITTER 1 TO 4SPLITTING IMAGES: 1x4 HDMI Splitter distributes 1 HDMI input into 4 corresponding synchronized outputs with an advanced chip that can analyze and process up to 225 MHz LOSSLESS STREAMS: Our HDMI Splitter allows for zero transmission loss even for long distances of 50 feet; outside metal casing both protects the internal components and dissipates heat for better performance. COMPATIBILITY: GadgetsAccessories HDMI splitter supports 480P, 576P, 720P, 1080i, 1080P, 4K and 3D up to 3840x2160 resolution; Audio Formats supported: LPCM7.1, DTS, DOLBY-AC3, DSD/DTS-HD, Dolby-trueHD with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
211Supply, Installation, testing & commissioning of RJ45 Connector including cost of petty material required to complete the work up to the entire satisfaction of Engineer In Charge.
212Supply, Installation, testing & commissioning of IR BULLET Network Camera including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge having minimum technical specifications
213Supply & erection of dust & water proof outdoor box of Size 4" X 4" for CCTV Camera with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
214Supply, installation, testing and commissioning of POE based IP PHONE 2 line keys with dual-color LED and 1 SIP account, 3 XML programmable context sensitive soft keys, 5 (navigation, menu) keys. 13 dedicated func- tion keys for PAGE/INTERCOM, PHONEBOOK, MESSAGE, HOME, HOLD, RECORD, MUTE, HEADSET, TRANSFER, CONFERENCE, SEND and REDIAL, SPEAKERPHONE, VOLUME with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
215Supply, installation, testing and commissioning TV Broadcasting System with Network video Reciever TCP/IP Support with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
216Supply, installation, testing and commissioning PA Horn Louds peaker made with ABS, water and dust protected to IP65, Sound pressure level at 15W/1W- 115/103 db (SPL), Effective frequency range 500 Hzs to 5 KHz,Fitted with 0.6m (2’) 2-core sheathed speaker cable, secured through a water-tight, tug-proof cable gland. They meet European Union regulations and comply with low voltage directive standard EN 60065. Degree of protection with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. (AHUJA/BOSCH/ITC/EV/ MEGA)
217Supply, installation, testing and commissioning of 60 WATTS WITH BUILT-IN DIGITAL PLAYER MEDIUM WATTAGE PA MIXER AMPLIFIER 3 Mic & 1 Aux Input. Built-in MP3 player with USB reader and remote control, frequency range 50-15000 Hz, signal to noise ratio 60db, Line Output for connecting to a Booster Amplifier. Cut type tone control with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work.
218Supply, installation, testing and commissioning of Outdoor Wifi AP Complies with IEEE 802.11b/g, wireless speed up to 54Mbps Outdoor weatherproof and 4000V lightning/15KV ESD protection design 12dBi dual-polarized antenna to build long distance WiFi connection up to 2km High power to boost your signal coverage and link speed Up to 60 meters (200 feet) of flexible deployment with included power over Ethernet injector with all labour and material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of the work. (RUCKUS/CISCO/TPLINK/DLINK)
219Supply & erection of PVC Battan of Size 25 x 16 mm Thick, complete in all respect including cost of PVC guttis, steel screws and labour etc.Non DNIT NS
220Supply and erection of PVC Channel 50 x 50mm thick complete in all respect including cost of PVC guttis, steel screws and labour etc.Non DNIT NS
221S/E of hot press moulded SMC junction box (Sintex, Hansel, Somshiva) with hinged cover on existing pole/wall complete with clamps, nuts & bolts, DIN channel for erection of SPMCB/TPNMCB and copper terminal block for 3 phase 4 wire system including labour, petty material and making necessary connections etc but excluding cost of MCB. (i) Size 185 mm x 165 mm x 60 mm (inside) & 225 mm x 205 mm x 65 mm (outside) Non DNIT NS
222S/E of PVC insulated multi core copper conductor cable (unarmoured) 1100 volts grade (round) in existing pole/ pipe, complete in all respect including making necessary connections. Non DNIT NS Size 1.5 Sqmm x 2 core
223Supply, installation testing and commisioning of outdoor High frequency 13.25 Mifare RFID and figerprint Biometric (STQC Certified) duty enforcement and control system of following specifications:- Operating system - Android, Display Size- 7
224Total NS Items (Smart Integrated Solution (Access control, Video Surveillance, Network Broad casting, Announcement, RFID/ Biometric etc.)