Public Health Engineering Department-PHED has published Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Shopian Fixing Of Rate Contract For Repairs / Replacement To Electrical Equipment Installed At Different Wsss Of Phe Mec. Submission Date for this Tender is 26-08-2021. Bolts Tenders in Shopian Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Providing, fitting and testing of Copper thimbles at site |
2 | 1. 10 Sq. mm |
3 | 2. 16 Sq. mm |
4 | 3. 25 Sq. mm |
5 | 4. 50 Sq. mm |
6 | Providing, fitting and testing of Aluminum thimbles at site |
7 | 1. 10 Sq. mm |
8 | 2. 16 Sq. mm |
9 | 3. 25 Sq. mm |
10 | 4. 50 Sq. mm |
11 | 5. 90 Sq. mm |
12 | 6. 120 Sq. mm |
13 | 7. 150 Sq. mm |
14 | Providing, fitting of below mentioned item for repairs to 25KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
15 | Copper wire of specific gauge for fabrication of primary / secondary coil |
16 | Bush rod with porcelain insulator and packing |
17 | Rewinding/Re-taping /re-insulation of coils |
18 | T-Oil |
19 | Copper strip |
20 | Filtration / dehydration of T-oil |
21 | Cost of scrap copper dismattled windings |
22 | Cost of damaged lamination |
23 | Providing, fitting of below mentioned item for repairs to 35KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
24 | Copper wire of specific gauge for fabrication of primary / secondary coil |
25 | Bush rod with porcelain insulator and packing |
26 | Rewinding/Re-taping /re-insulation of coils |
27 | T-Oil |
28 | Copper strip |
29 | Filtration / dehydration of T-oil |
30 | Cost of scrap copper dismattled windings |
31 | Cost of damaged lamination |
32 | Providing, fitting of below mentioned item for repairs to 50KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
33 | Copper wire of specific gauge for fabrication of primary / secondary coil |
34 | Bush rod with porcelain insulator and packing |
35 | Rewinding/Re-taping /re-insulation of coils |
36 | T-Oil |
37 | Copper strip |
38 | Filtration / dehydration of T-oil |
39 | Cost of scrap copper dismattled windings |
40 | Cost of damaged lamination |
41 | Providing, fitting of below mentioned item for repairs to 75KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
42 | Copper wire of specific gauge for fabrication of primary / secondary coil |
43 | Bush rod with porcelain insulator and packing |
44 | Rewinding/Re-taping /re-insulation of coils |
45 | T-Oil |
46 | Copper strip |
47 | Filtration / dehydration of T-oil |
48 | Cost of scrap copper dismattled windings |
49 | Cost of damaged lamination |
50 | Providing, fitting of below mentioned item for repairs to 100KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
51 | Copper wire of specific gauge for fabrication of primary / secondary coil |
52 | Bush rod with porcelain insulator and packing |
53 | Rewinding/Re-taping /re-insulation of coils |
54 | T-Oil |
55 | Copper strip |
56 | Filtration / dehydration of T-oil |
57 | Cost of scrap copper dismattled windings |
58 | Cost of damaged lamination |
59 | Providing, fitting of below mentioned item for repairs to 125KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
60 | Copper wire of specific gauge for fabrication of primary / secondary coil |
61 | Bush rod with porcelain insulator and packing |
62 | Rewinding/Re-taping /re-insulation of coils |
63 | T-Oil |
64 | Copper strip |
65 | Filtration / dehydration of T-oil |
66 | Cost of scrap copper dismattled windings |
67 | Cost of damaged lamination |
68 | Providing, fitting of below mentioned item for repairs to 150KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
69 | Copper wire of specific gauge for fabrication of primary / secondary coil |
70 | Bush rod with porcelain insulator and packing |
71 | Rewinding/Re-taping /re-insulation of coils |
72 | T-Oil |
73 | Copper strip |
74 | Filtration / dehydration of T-oil |
75 | Cost of scrap copper dismattled windings |
76 | Cost of damaged lamination |
77 | Providing, fitting of below mentioned item for repairs to Voltage regulator (plate type switch) including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
78 | 1. 150mmx150mm |
79 | 2. 225mm x 225mm |
80 | 3. 200mm x 200mm |
81 | 4. 250mm x 250mm |
82 | 4. 300mm x 300mm |
83 | Providing, fitting of below mentioned item for repairs to Voltage regulator (drum type switch) including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
84 | 1. 32A |
85 | 2. 63A |
86 | 3. 100A |
87 | 4. 200A |
88 | Providing, fitting and testing of Voltmeters at site |
89 | 0-200V |
90 | 0-500V |
91 | Providing, fitting and testing ofThree phase digital type LED voltmeters class 1at site - Make L&T/Rishab |
92 | 0-500V |
93 | Providing, fitting and testing of Ammeters at site |
94 | 1. 0-50A with CT ratio of 5/50 |
95 | 2. 0-100A with CT ratio of 5/100 |
96 | 3. 0-150A with CT ratio of 5/150 |
97 | 4. 0-200A with CT ratio of 5/200 |
98 | Providing, fitting and testing of 96 sq mm Three phase digital LED Ammeters class1at site - Make L&T/Rishab |
99 | Providing, fitting and testing of Three phase Analogus type 0-50HZ frequency meter at site - Make L&T/Rishab/AE |
100 | Providing, fitting and testing of post type drop out set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
101 | Suitable for 25KVA SS |
102 | Suitable for 63KVA SS |
103 | Suitable for 100KVA SS |
104 | Suitable for 250KVA SS |
105 | Providing, fitting and testing of link set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
106 | Suitable for 25KVA SS |
107 | Suitable for 63KVA SS |
108 | Suitable for 100KVA SS |
109 | Suitable for 250KVA SS |
110 | Providing, fitting and testing of 11KVA Disc set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
111 | Providing, fitting and testing of 11KVA pin insulators including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
112 | Providing, fitting and testing of submersible copper cables of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
113 | 1. 10 sq mm |
114 | 2. 16 sq mm |
115 | 3. 25 sq mm |
116 | Providing, fitting and testing of copper cables of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
117 | 1. 19/0.0064 |
118 | 2. 37/0.083 |
119 | 19/0.044 |
120 | 7/16.00 |
121 | Providing, fitting and testing of 3.5 core XLPE aluminum conductor of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
122 | 1. 35 Sq. mm |
123 | 2. 50 Sq. mm |
124 | 3. 70 Sq. mm |
125 | 3. 95 Sq. mm |
126 | 4. 120 Sq. mm |
127 | 5. 185 Sq. mm |
128 | Providing, fitting and testing of 11KVAXLPE aerial Bunched cable(HT)of below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
129 | 1. 35 Sq. mm |
130 | 2. 50 Sq. mm |
131 | Providing, fitting and testing of 11KVAcable termination/Jointing kit set below mentioned specifications including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
132 | 1. 35 Sq. mm |
133 | 2. 50 Sq. mm |
134 | Providing, fitting and testing of 11KV post type lightening arrestor including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
135 | Providing, fitting and testing of G.O.D set including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
136 | Providing, fitting and testing of Cross arms including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
137 | 1. Channels 75x40 |
138 | Channels 100 x 50 |
139 | 2. Angle iron support |
140 | 3. F-top |
141 | 4. U Clamps |
142 | 5. Guy-wire with turn buckle |
143 | 6. Guy-Insulator |
144 | Providing, fitting and testing of ACSR Conductor including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
145 | 1. 0.03 |
146 | 2. 0.05 |
147 | Providing, fitting and testing of MCCBs (04 Pole) including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
148 | 63 Amps |
149 | 100 Amps |
150 | 125 Amps |
151 | 160 Amps |
152 | 200 Amps |
153 | 250 Amps |
154 | 320 Amps |
155 | 400 Amps |
156 | Providing, fitting and testing of MCCBs (03 Pole) including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
157 | 63amps |
158 | 100amps |
159 | 125amps |
160 | 160amps |
161 | 200Amps |
162 | 250amps |
163 | Providing, fitting and testing of Change over switch including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. |
164 | 63 A |
165 | 100 A |
166 | 200 A |
167 | 300 A |
168 | 400 A |
169 | Providing, fitting and testing of on load Change over switch Front operated on load 4 pole including extraction of damaged ones, transportation, loading, unloading, fitting and successful testing on no and full load at site. Make - L& T |
170 | 100 Amp |
171 | 200Amp |
172 | Providing, fitting and testing of Combined volt-ammeter for MU-G starters |
173 | 30A |
174 | 60A |
175 | 75A |
176 | 100A |
177 | 125A |
178 | Providing, fitting and testing of 415V Indicating lamps |
179 | Red |
180 | Yellow |
181 | Green |
182 | Providing, fitting and testing of 415V Single phase preventor |
183 | Providing, fitting and testing of ML contactors for starters |
184 | ML 1.5 |
185 | ML 2 |
186 | ML 3 |
187 | ML 4 |
188 | ML 6 |
189 | ML 10 |
190 | ML 12 |
191 | Providing, fitting and testing of Power contactors for FASD starters |
192 | LCIF 400 |
193 | LCIF 650 |
194 | LCIF 350 |
195 | CK 95 BE-300 |
196 | MNX 185 |
197 | MNX 325 |
198 | AC3-25A |
199 | AC3-32A |
200 | AC3-40A |
201 | AC3-50A |
202 | MC X 70 |
203 | AC3- 60A |
204 | AC3- 63A |
205 | AC3- 80A |
206 | AC3- 100A |
207 | AC3- 115A |
208 | AC3- 125A |
209 | AC3- 150A |
210 | AC3- 185A |
211 | AC3- 200A |
212 | AC3- 250A |
213 | AC3- 265A |
214 | AC3- 330A |
215 | AC3- 350A |
216 | Providing, fitting and testing of ML relays |
217 | ML1 range 4-6.5 |
218 | ML1 range 6-10 |
219 | ML1 range 10-16 |
220 | ML2/ML3 9-14 |
221 | ML2/ML3 13-21 |
222 | ML2/ML3 20-32 |
223 | Providing, fitting and testing of FASD Panel accessories |
224 | Electronic timer 0- 30Sec |
225 | Electronic timer 0- 60Sec |
226 | Single Phase Preventer(Three phase type ) |
227 | Overload relay 4A-6A |
228 | Overload relay 5A-8A |
229 | Overload relay 6A-9A |
230 | Overload relay 7A-10A |
231 | Overload relay 9A-13A |
232 | Overload relay 12A-16A |
233 | Overload relay 14A-22A |
234 | Overload relay 17A-25A |
235 | Overload relay 23A-32A |
236 | Overload relay 30A-40A |
237 | Overload relay 37A-50A |
238 | Overload relay 48A-65A |
239 | Overload relay 55A-70A |
240 | Overload relay 63A-80A |
241 | Overload relay 80A-93A |
242 | Overload relay 85A- 105A |
243 | Overload relay 80A- 115A |
244 | Overload relay 125A- 200A |
245 | Overload relay 160A- 250A |
246 | Overload relay 200A- 315A |
247 | Replacement of damaged 1 Sq mm copper power wiring |
248 | Providing, fitting and testing of ATS star Delta starter |
249 | Pneumatic timer (on delay/off delay) |
250 | Electromagnetic power contactor assembly (10A-250A) |
251 | Providing, fitting and testing of Contact points for star/delta starters |
252 | 20HP |
253 | 30HP |
254 | 40HP |
255 | 50HP |
256 | Providing, fitting and testing of Terminal block |
257 | 30A-5 way |
258 | 60A-3way |
259 | 60A-6 way |
260 | 100A-3 way |
261 | 120A-3 way |
262 | Providing, fitting and testing of Power contactor for MU-G starters |
263 | MU-G10 |
264 | MU-G15 |
265 | MU-G20 |
266 | MU-G30 |
267 | MU-G40 |
268 | MU-G50 |
269 | MU-G75 |
270 | Providing, fitting and testing of Overload relay/under voltage relay/single phase preventer/Timer for MU-G starters |
271 | MU-G10 |
272 | MU-G15 |
273 | MU-G20 |
274 | MU-G30 |
275 | MU-G40 |
276 | MU-G50 |
277 | MU-G75 |
278 | Providing, fitting and testing of single phase preventer/Timer for MU-G starters |
279 | MU-G10 |
280 | MU-G15 |
281 | MU-G20 |
282 | MU-G30 |
283 | MU-G40 |
284 | MU-G50 |
285 | MU-G75 |
286 | Providing and fitting of Multi-Function Meter Square Dial type |
287 | Providing, fitting of below mentioned item for repairs to 30KVA Voltage Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
288 | Copper wire of specific gauge for fabrication of primary / secondary coil |
289 | Bush rod with porcelain insulator and packing |
290 | rewinding/Re-taping /re-insulation of coils |
291 | T-Oil |
292 | Copper strip |
293 | Filtration / dehydration of T-oil |
294 | Cost of scrap copper dismattled windings |
295 | Cost of damaged lamination |
296 | Nuts and bolts of different size |
297 | Providing/Fitting of voltmeter/Ammeter Selector Switch |
298 | Start/ stop Flush type button with contact block for MU-G starters |
299 | Providing, fitting of below mentioned item for repairs to 10KVA to 50KVA Servo Stabilizer including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site. |
300 | Replacement of digital micro controlled processor based control card |
301 | Replacement of AC syncronous servo motor |
302 | Replacement of copper wound motorized auto transformer |
303 | Replacement of buck and boost series transformer |
304 | Repairs to LED lights at site by way of replacing strips |
305 | 25Watt |
306 | 45Watt |
307 | 48Watt |
308 | 50Watt |
309 | 60Watt |
310 | 90Watt |
311 | 100Watt |
312 | 120Watt |
313 | Erection of MS tubular 9m/11m tilted pole by way of excavation of new trench and concrete bottoming including fitting/fixing of Departmental ACSR conductor on the insulators |
314 | Repairs to horizontal Motor with rating from 5HP to 50HP Dismantling of the horizontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. |
315 | Copper wire used in rewinding the motor. |
316 | Rewinding,Skilled labor, insulated paper and sleeves used during rewinding and testing of motor at site. |
317 | Cost on account of associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc |
318 | Cost of scrap copper dismanttled windings |
319 | Repairs to horizontal Motor with rating above 50HP to 100HP) Dismantling of the horiontal motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. |
320 | Copper wire used in rewinding the motor. |
321 | Rewinding,Skilled labor, insulated paper and sleeves used during rewinding and testing of motor at site. |
322 | Cost on account of associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc |
323 | Cost of scrap copper dismanttled windings |
324 | Repairs to submersible Motor with rating from 5HP to 50HP Dismantling of the submersible motor at site, shifting to the workshop, repairing, shifting back to site, re-fitting and successfull testing on full load. Job includes repairing / fabrication and providing / replacement of following items. |
325 | Copper wire used in rewinding the motor. |
326 | Rewinding,Skilled labor, insulated paper and sleeves used during rewinding and testing of motor at site. |
327 | Cost on account of associated/consumable items like crimpled paper, sleeves, PVC paper, bamboo sticks, thread, varnish etc |
328 | Cost of scrap copper dismanttled windings |
329 | Removal of damaged submersible pumping unit from river water for necessary checkups/ repairs / removal of all obstructions and re-installation / lowering of pumping unit into the river water. The job includes hiring of boat/ boatman for two days/ two visits for extraction and its lowering. |
330 | Replacing of damages illumination single core multistranded copper wiring |
331 | 1 Sq mm |
332 | 1.5 Sq mm |
333 | 2 Sq mm |
334 | 2.5 Sq mm |
335 | 4 Sq mm |
336 | Replacing of damages illumination single core multistranded copper wiring |
337 | Replacement of damaged electrification and electrification of pump house including cost of channels/conduits, fitting charges, transportation and testing on load at site |
338 | Lighting points in 1.0mm2 copper wire including 5W LED lamp |
339 | Heating points in 2.5 mm2 copper wire including 16Amp SS combined |
340 | Providing of 5W/7W LED lamp |
341 | Replacement of damaged LED street light 48W (Havells make) |
342 | Providing, fitting Racer plate to submersible motor from 05HP to 50HP including extraction of damaged items, transportation, loading, unloading, shifting back and then fitting and successful testing on no and full load at site |
343 | Providing/fitting of Steel coupling for submersible motors from 05HP to 50 HP including cotter |
344 | Providing/fitting of connection platefor Horizontal motors from 05HP to 50 HP |
345 | Repairs to the rotor/body of submersible motor |
346 | Repairs to the rotor/body, fan, shield of Horizontal motor |
347 | Providing/fitting of M S coupling for Horizontal motors from 05HP to 50 HP including cotter and boring |
348 | Providing/fitting of Gun metalbush (finished) to the submersible motor from 05HP to 50HP as per sample |
349 | Repairs to self / Dynamo of DG set |
350 | Providing/fitting of AVR to DG set as per sample (25 KVA to 62.5KVA) |
351 | Repair and rewinding of DG set cooling fan |
352 | Minor overhauling of DG set including repair to radiator |
353 | Providing/fitting of Battery connection leads with copper connectors |
354 | Note: The Scrap Value mentioned above shall be deducted from the total valve of BOQ to arrive at value without scrap. The value thus attained shall be again deducted by total scrap value to get the effective amount on BOQ for ascertainingoverall L1. Unless specified, the old material shall be returned to divisional/sub divisional store |