| 1 | Dismantling/Demolition of existing shed building at site construction fromFoundation to Roof truss manuakl/Mechanical means including stacking at the serviceable material outside the complexas directed by Engineer in charge |
| 2 | Earthwork bulk excavation by mechanical means (hydraulic excavator) over areas and disposal of excavated earth lead as directed by Engineer in charge at site. |
| 3 | Lying of stone soling being properly handpicked consolidating, leveling and all leads of carriages up to site of work. |
| 4 | P/L in position the cement concrete of specified grade of mix in 1:4:8 mix with nominal size of stone aggregate 40 mm thick crushed excluding cost of centering and shuttering. (Mud Mat) |
| 5 | P/L in position the cement concrete of specified grade of mix in 1:1.5:3 mix with nominal size of stone aggregate 40 mm thick crushed excluding cost of centering and shuttering. (Raft) |
| 6 | Centering and shuttering with strutting, propping etc. and removal of form work of size 0.01m to 0.2 m Block 1 |
| 7 | P/L in position the cement concrete of specified grade of mix in 1:2:4 mix with nominal size of stone aggregate 40 mm thick crushed excluding cost of centering and shuttering. (Beam Blocks) |
| 8 | Filling with stone-dust to under floors incl: watering consolidating and all leads of carriages up to site. |
| 9 | Brick work with common burnt clay (non modular) bricks of class designation 7.5 including curing & 1:6 cement mortarwith all leads of carriages up to site of work |
| 10 | 12 MM cement plaster in 1:6 mix incl: all leads of carriage upto site of work and curing complete. |
| 11 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, , polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 12 | CERAMIC TILES for walls:Providing and laying Ceramic tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. Size of tile 500x500 mmMake: Kajaria, Somani |
| 13 | Structural steel work in built up sections,trusses and framed work, doors, including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer. |
| 14 | P/F Color Coated profile sheets High Rib 0.50 mm TCT having a crest height of 28-32 mm at 195 mm pitch and effective width of 975-1000 mm and length to suite requirement to purlins using self-drilling and self-tapping fasteners of reputed make with purlin sheet using self drilling and self tapping fasteners and fixing flashings, valleys and ridges of color coated galvalume plain sheet of reputed make complete as directed at site of work. |
| 15 | P/F in position wooden evesboarding of 300 x 40 MM size incl: cost of screws etc.complete job at site of work as directed. 2ND class kail wood |
| 16 | Motorised Sprinkler System for spraying Disinfectant in all chambers. Made of G.I Pipes C- Class (1/2” dia) should be fixed on top of the Garbage dumping Shed including fixing of Stainless Steel or brass nozzles. The whole system is to be fixed with 02 H P Monoblock Pump Set with following specifications:HP-3Head: 25-30mSize (mm)- 50x40RPM -2800 03 Phase440V ThePump Set is to be connected to the nearest electric point along with all accessories to make it fully functional. |
| 17 | Painting with synthetic enamel paint of approved shade, brand and manufacture on new surface with two or more coats over and under coat of suitable shade with ordinary brand of approved brand and manufacture. |
| 18 | Wiring forpower plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 19 | Providing and fitting of Electrical points (16 Amp sockets – 4 Nos / 6Amp sockets – 4 Nos / 12W LED Ceiling Panel Lights along with switches – 4 Nos / 35 W LED flood light over the DG set along with switch and other allied fixtures. The job shall include providing and laying/fitting of PVC conduits, clamps, Wire of suitable size, switch modules, MCB’s,junction boxes, isolators and all other allied fittingsof suitable capacity /grade. |
| 20 | P/F in position Aluminum work for doors,windows,ventilators etc.with extuded built up sections/appropriate Z-section/tubular section and other sections of app:make confirming to IS:733 and IS:1285 fixed with rowel plugs and screws incl:necessary screws,filling up of gaps and junctions at top bottom and sides with required neoperene felts etc,glazing and panels to be paid separately for fixed portion powder coated aluminum, complete job at site of work |
| 21 | Steel reinforcement for R.C.C work incl:straightening,cutting,bending,placing in position and binding all complete uptoploor v level complete. TMT bars of grade Fe-500D or more. |