Renovation Work Of Old Ranchi Municipal Building, Ranchi Renovation Work Of Old Ranchi Municipal Building, Ranchi, Ranchi-Jharkhand

Urban Development Department-UDD has published Renovation Work Of Old Ranchi Municipal Building, Ranchi Renovation Work Of Old Ranchi Municipal Building, Ranchi. Submission Date for this Tender is 17-08-2021. Building Work Tenders in Ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

28725243
Renovation Work Of Old Ranchi Municipal Building, Ranchi Renovation Work Of Old Ranchi Municipal Building, Ranchi
Open Tender
Indian
Jharkhand
Ranchi
17-08-2021

Tender Details

Renovation Work Of Old Ranchi Municipal Building, Ranchi Renovation Work Of Old Ranchi Municipal Building, Ranchi

Key Value

Document Fees
INR 10000 /-
EMD
INR 237000.0 /-
Tender Value
INR 2.36 Crore /-

BOQ Items

Name of Work: Renovation Work of Old Ranchi Municipal Building, Ranchi
Sl. No. Item Description
1PART-01 Dismantling/ Repair works
2Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
3Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
4Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l.
5Taking down old door and window shutters including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.
6Taking down chowkhat in doors including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.
7Taking down chowkhat in windows including stacking serviceable materials within 15M. lead and disposal of unserviceable materials with all leads all complete as per direciton of E/l.
8Removal of old tarfelt and disposal of debris with all leads complete job as per direction of E/l.
9Making holes in walls for fixing in cement concrete (1:2:4) tees of bed stone etc., including the cost of fixing the materials and disposal of debris with all leads etc. all complete as per direction of E/l.
10Leak repair to terraced roof with cement and powder application, including cost of all labour and materials, dismantling old terrace where necessary, disposal of unserviceable materials, all complete, as per building specification and direction of E/l.
11Crack repair to terraced roof with cico or any other leak stop materials of approved quality after cutting it to "V" shape including cost of all labour and materials, dismantling old terrace where necessary, disposal of unserviceable materials, all complete, as per building specification and direction of E/l.
12Easying and adjusting door and window shutters with chowkhats in old work complete as per specification and direction of E/l.
13Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge.
14Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge.
15Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall
16Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. for thickness of tiles 10mm to 25mm
17Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
18PART-02 CIVIL WORKS
19Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/l.
20Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l.
21Providing 25 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
22Providing rough cast plaster in 2 layers, the bottom layer being 12mm thick in cement mortar (1:3) and top layer finished with gravel, pebbles or curshed stone as per specified cement mortar (1:3) with clean coarse sand of F.M. 1.5 including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l..
23Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc. all complete as per direction of E/l.
24Providing Designation 100AB/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
25Providing Designation 100A112 mm thick reinforced B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:4) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including the cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
26Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:2:4 (1 cement : 2 coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size)
27Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
28Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies, shelves, chajjas, linterls, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size)
29Providing plain M.S. reinforcement of 6 mm or 8 mm dia rods as per approved design and drawing excluding carriage of M.S. Rods (straight or in coils) to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (ii) 8 mm dia. Gr.-A
30Providing Tor steel reinforcement of 10mm. ,12mm & 16mm dia. bars as per approved design and drawing excluding carriage of M.S. bars to work site , cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction of E/l. (b)12mm (TMT,Coil Fe 500)
31PART-03 Flooring/Wall tiles
32Providing 50 mm thick cement concrete flooring (1:2:4) with 20 mm to 6mm size graded stone chips finished with floating coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/l
33Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement
34Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
35Providing and laying Vitrified paring/Industrial tiles in different sizes (thickness to be specified by manufacturer) with water absorpiton less than 0.08% and conforming to IS:4457:2007 , of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1cement :4coarse sand), jointing with grey cement @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. compete .size of tile 300X300X10mm sizes.
36Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
37Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
38Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x800 mm
39PART-04 DOORS/WINDOW
40Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm)
41Providing and fixing brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass screws and wooden plugs etc. wherever necessary complete. 25 mm diameter.
42Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete
43Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete : 150 mm
44Providing and fixing bright finished brass helical door spring (superior quality).
45Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 125x70x4 mm (ordinary type)
46Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete.
47Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
48Supplying, fitting and fixing 30mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
49Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
50Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/l. 100mm Butt Hinge.
51Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/l. 75mm Butt Hinge.
52Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/l. 300mm sliding door bolt.
53Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/l. 250mm sliding door bolt.
54Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/l. 150mm tower bolt.
55Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/l. 100mm tower bolt.
56Supplying, fitting and fixing oxidised iron fittings of approved quality and make to doors and windows all complete as per building specification and direction of E/l. 100mm door handle with plate.
57Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 75mm
58Supplying, fitting and fixing callapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l.
59Providing two coats of painting with ready mixed paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt, including scales smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specfication and direction of E/l.
60Providing two coats of painting with ready mixed paint over a coat of primer of approvedshadeandmakeovernew woodensurface including pareparing the surface after cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffolding and taxes all complete as per building specfication and direction of E/l
61Labour for scrapping old paint with paint remover and blow lamp as required on wooden or steel surface including cost of all labour and materials and scaffolding all complete as per building specification and direction of E/l.
62Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing rust , dirt, , scales , smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/l. ( Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specification)
63Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
64Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)
65Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
66For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
67Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
68Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
69Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
70Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of5 mm, made out of extrude 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame.The door frame to be fixed to the wall using M.S. screws of65/100 mm size complete as per manufacturers specification and direction of Engineer-in-Charge.
71Providing and fixing 30mm thick factory made PVC rigid foam panelled door shuttersmade from M.S. tube of 19 gauge thickness, size 19x1 9mm for styles and 15x1 5mm for top and bottom rails, covered with heat moulded PVC "C" channel of 5mm thick sheet and 30x50mm wide to form styles and 5mm thick and 75mm wide PVC sheets for top rail, lock rail and bottom rail on either side and 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, panelling of 5mm thick PVC sheet fitted in the M.S. frame welded/ sealed to the styles and rails with 5x30mm PVC sheet beading on either side and joined together with solvent cement adhesive etc., complete as per manufacturers specification and direction of Engineer-in-Charge fixed to frames with 4 Nos. M.S. powder coated butt hinges( For W.C. and bathroom shutters)
72Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness
73PART-05 Painting/White washing
74Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/l.
75Providing two coats of snowcem of approved shade and make over old surface including washing cleaning, and preparing the walls, scaffolding, curing and taxes all complete as per building specification and direction of E/l.
76Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/l.
77Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
78Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer"s specification. Two or more coats on new work
79Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
80Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
81PART-06 Terrace Treatment/Water proofing
82Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
83Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
84PART-07 Sanitary/Plumbing
85Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.
86Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15mm nominal outer dia Pipes
87Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20mm nominal outer dia Pipes
88Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25mm nominal outer dia Pipes
89Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm nominal outer dia Pipes
90Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 15mm nominal outer dia Pipes
91Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20mm nominal outer dia Pipes
92Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25mm nominal outer dia Pipes
93Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32mm nominal outer dia Pipes
94Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm nominal outer dia Pipes
95Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm nominal outer dia Pipes
96Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 62.5mm nominal outer dia Pipes
97Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 75mm nominal outer dia Pipes
98Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 100mm nominal outer dia Pipes
99Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
100Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: 15 mm nominal bore
101Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore
102Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
103Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
104Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
105Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore
106Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 20 mm nominal bore, 120 mm long, weighing not less than 198 gms
107Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 25 mm nominal bore, 152mm long, weighing not less than 440 gms
108Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
109Rain WaterPipe
110Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
111Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
112Single tee with door 75x75x75 mm
113Single tee with door 110x110x110 mm
114Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
115Providing and fixing 15 mm dia and 45 cm. long P. V .C connection pipe with heavy quality brass coupling at both ends etc. all complete as per specification and direction of E/l
116Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., "p" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (c) with 12.5 lit. low level P.V.C. cistern
117Supplying, fitting and fixing 40mm high vitreous white glazed earthen E.W.C. with ‘p’ trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I.handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming, all complete as per specification and direction of E/I. (ii) E.W.C. with "S" trap. (b)12.5 lit. low level P.V.C. cistern
118Supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I.brass waste, 15 mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
119Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
120Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern
121Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
122Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
123Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
124Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
125Providing and fixing stone slab with table rubbed, edges rounded and polished,m of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-incharge and finished smooth.
126PART-08 Flase ceiling
127Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board
128Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
129PART-09 STORAGE
130Providing ply wood partition upto 2.5M height with 4mm thick commercial ply wood of standard make fitted and fixed both sides over sal wood frame of 50x50mm posts at 122cm centres and 3 nos 50 x 50mm horizontal members inclduing cost of anchoring the partition to floors and walls properly and providing 2 coats of synthetic enamel paint over a coat of priming of approved shade and make and leaving space for doors if necessary all complete as per drawing specification and direciton of E/l. (4 mm thick ply)
131Particle Board 12 mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
132Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
133Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS: 12823 marked
134PART-10 G.S SHEET ROOFING
135Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/m²
136Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
137Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J, or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete: 1.60 mm thick with zinc coating not less than 350 gm/m²
138PART-11 (Deep boring, lettering, starter, Water purifier)
139Lettering with black Japan paint of approved brand and manufacture per letter per cm height 4.70
140Cost of Drilling 200mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools, driling rig, air compressure and equipments as well as fule, lubricants and cost of transportation of rig machine annd other vehical up to Site. (a) From 0.00 M to 50.00 M below G.L.
141Cost of Drilling 200mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools, driling rig, air compressure and equipments as well as fule, lubricants and cost of transportation of rig machine annd other vehical up to Site. (b) From 51.0 M to200.00 M
142Supplying of 200mm x 3.00m long UPVC casing pipe confirming to IS: 12818:2016 (CML No. 5543459) laters revision including carriage.
143Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
144Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
145Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 2 HP
146D.O.L starter with S.S Enclosure with 380/415 Volt coil as per IS 3914 - upto 5 HP
1473 core PVC insulated, PVC sheathed copper conductor flat submersible cable- Supplying, Flat flexible submersible cable with, copper conductor, PVC insulated and PVC sheathed. 3 core 4 sqmm
148Supplying all tools, equipments and labour and doing washing flushing and development of drilled tubewell to give clean and clear water all completed as per direction of E/I
149Supplying labour cement and calcium chloride or bentonite solution and equipments for grouting and casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification and direction of E/I.
150Misc.
151Chiller cum Purifier. Water storage capacity- 120 ltrs./hr., Water cooling capacity- 60 LPH 3 nos. Faucets
152MS storage rack - 7ft. X 4ft. - 4 layered
153Part-12(ELECTRICAL WORK)
154S/F PVC conduit- supplying & fixing of following sizes of PVC conduit with accessories in surface / recess including cutting the wall & making good the same in case of recessed conduit as required 20mm
155S/F PVC conduit- supplying & fixing of following sizes of PVC conduit with accessories in surface / recess including cutting the wall & making good the same in case of recessed conduit as required 25 mm
156S/F PVC conduit- supplying & fixing of following sizes of PVC conduit with accessories in surface / recess including cutting the wall & making good the same in case of recessed conduit as required 32 mm
157S/F PVC conduit- supplying & fixing of following sizes of PVC conduit with accessories in surface / recess including cutting the wall & making good the same in case of recessed conduit as required 40 mm
158Point wiring in PVC conduit , with modular type switch- wiring for light point fan point / exhaust fan point / call bell point with 1.5 sq mm FR PVC insulated CU conductor single core in surface / recessed PVC conduit modular switch with modular plate , phenolic laminted sheet with suitable size PVC/ MS box as required. Group C
159Twin control point wiring in PVC conduit , with modular type switch- wiring for twin control pointwith 1.5 sq mm FR PVC insulated CU conductor single core cable in surface / recessed PVC conduit two way modular switch with modular plate , phenolic laminted sheet with suitable size PVC/ MS box as required.
160Circuit sub-main wiring in PVC conduit - wiring for circuit / sub main wiring along with earth wire with following size of FR PVC insulated CU conductor single core cable in surface / recessed PVC conduit as required 2x1.5 sq mm+ 1x1.5 sq mm earth wire
161Circuit sub-main wiring in PVC conduit - wiring for circuit / sub main wiring along with earth wire with following size of FR PVC insulated CU conductor single core cable in surface / recessed PVC conduit as required 2x2.5 sq mm+ 1x2.5 sq mm earth wire
162Circuit sub-main wiring in PVC conduit - wiring for circuit / sub main wiring along with earth wire with following size of FR PVC insulated CU conductor single core cable in surface / recessed PVC conduit as required 2x4 sq mm+ 1x4 sq mm earth wire
163Circuit sub-main wiring in PVC conduit - wiring for circuit / sub main wiring along with earth wire with following size of FR PVC insulated CU conductor single core cable in surface / recessed PVC conduit as required 2x6 sq mm+ 1x6 sq mm earth wire
164Circuit sub-main wiring in PVC conduit - wiring for circuit / sub main wiring along with earth wire with following size of FR PVC insulated CU conductor single core cable in surface / recessed PVC conduit as required 2x10 sq mm+ 1x6 sq mm earth wire
165Circuit sub-main wiring in PVC conduit - wiring for circuit / sub main wiring along with earth wire with following size of FR PVC insulated CU conductor single core cable in surface / recessed PVC conduit as required 2x16 sq mm+ 1x6 sq mm earth wire
166Supply & fixing of following sizes or modules of GI boxes along with modular base & conver plate for modular switches in recess etc as required 1 or 2 module(78X78X45mm)
167Supply & fixing of following sizes or modules of GI boxes along with modular base & conver plate for modular switches in recess etc as required 4 or 5 module(78x140x50mm)
168Supply & fixing of following sizes or modules of GI boxes along with modular base & conver plate for modular switches in recess etc as required 6 module(78x205x50mm)
169Supply & fixing of following sizes or modules of GI boxes along with modular base & conver plate for modular switches in recess etc as required 8 or 9 module(78x230x60mm)
170S/F modular type switch socket- supply fixing of following modular switch socket on the existing mosular plate & switch box including coonections but excluding modular plate etc as required 5/6 amps 1 way switch
171S/F modular type switch socket- supply fixing of following modular switch socket on the existing mosular plate & switch box including coonections but excluding modular plate etc as required 5/6 amps 2 way switch
172S/F modular type switch socket- supply fixing of following modular switch socket on the existing mosular plate & switch box including coonections but excluding modular plate etc as required 15/16 amps 1 way switch
173S/F modular type switch socket- supply fixing of following modular switch socket on the existing mosular plate & switch box including coonections but excluding modular plate etc as required 5/6 amps 3 pin socket outlet
174S/F modular type switch socket- supply fixing of following modular switch socket on the existing mosular plate & switch box including coonections but excluding modular plate etc as required 15/16 amps 6pin socket outlet
175S/F modular type switch socket- supply fixing of following modular switch socket on the existing mosular plate & switch box including coonections but excluding modular plate etc as required Telephone socket outlet
176S/F modular type switch socket- supply fixing of following modular switch socket on the existing mosular plate & switch box including coonections but excluding modular plate etc as required TV antenna socket outlet
177S/F modular type Fan regulator- supply fixing of following stepped type electronic fan regulator on the existing mosular plate & switch box including connections but excluding modular plate etc as required
178S/F modular type blanking plate- supply fixing of following modular blanking plate on the existing modular plate & switch box including coonections but excluding modular plate etc as required
179S/F ceiling rose- supply & fixing 2 pin 5 amps ceiling rise on the existing junction bos or wooden block including coonection etc as required
180Supply of following PVC /XLPE insulated PVC sheathed heavy duty armoured electrical cable with AL conductor for working voltage upto & including 1100 volts(confirm to IS:1554 part 1) 16 sq mm 4 core
181Supply of following PVC /XLPE insulated PVC sheathed heavy duty armoured electrical cable with AL conductor for working voltage upto & including 1100 volts(confirm to IS:1554 part 1) 25 sq mm 3.5 core
182ITC of 40 KVA on line 3 phase UPS
183Laying & fixing of 1 no. PVC insulated & PVC sheathed XLPE power cabl of 1.1kv grade of following size on wall surface as required upto 35 sq mm (clamed with 1 mm thick saddle)
184supply , Installation , testing commissioning of 1200 mm(48") BLDC 5 star rating 32 w ceiling fan 3 blades confirming to IS 374:2019 including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm FR PVC insulated CU conductor single core cable etc as required
18512" 300 mm metal Exhaust fan
186SITC of 16" 400 mm wall fan
187SITC of following rating surface mounted LED tube light fitting suitable for 230V 50 HZ single phase supply etc complete as required 10/12 W LED tube light
188SITC of following rating surface mounted LED tube light fitting suitable for 230V 50 HZ single phase supply etc complete as required 20/22 W LED tube light
189SITC of following rating surface /recess mounted LED round & square downlight fitting suitable for 230V 50 HZ single phase supply etc complete as required confirm to IS:10322 part 5 section 2 or IEC62722 2"X2" LED panel light
190Supplying & Fixing following way horizointal type 3pole & neutral, Sheet metal MCB distribution board, 415V, on surface/recess, complete with tinned cu busbar, neutral busbar, reath bar, interconnections, powder painted including earthing ect as required (but without MCB/RCCB/isolator) 6way( 4+18) Double Door Horizointal type
191Supplying & Fixing following way horizointal type 3pole & neutral, Sheet metal MCB distribution board, 415V, on surface/recess, complete with tinned cu busbar, neutral busbar, reath bar, interconnections, powder painted including earthing ect as required (but without MCB/RCCB/isolator) 8way( 4+24) Double Door Horizointal type
192Supplying & Fixing 8way(8+24)way Vertical type 3pole & neutral, Sheet metal MCB distribution board, 415V, on surface/recess, complete with tinned cu busbar, neutral busbar, reath bar, interconnections, powder painted including earthing ect as required( but without MCB/RCCB/isolator)
193Supplying & Fixing 6 amp to 32Amp rating 240V, 10KA"C" curve MCB suitable for inductive loads of following poles in existing MCB DB complete with connections testing & commissioning ect as required. 6/32 Amps SP MCB
194Supplying & Fixing 6 amp to 32Amp rating 240V, 10KA"C" curve MCB suitable for inductive loads of following poles in existing MCB DB complete with connections testing & commissioning ect as required. 6/32 Amps DP MCB
195Supplying & Fixing following rating 4pole 415V, isolator in existingMCB DB complete with connections testing & commissioning ect as required. 40Amp
196Supplying & Fixing following rating 4pole 415V, isolator in existingMCB DB complete with connections testing & commissioning ect as required. 63Amp
197Supplying & Fixing following rating double pole ( single phase+ Neutral) 240V, RCCB having asensitive current of 30mA in existingMCB DB complete with connections testing & commissioning ect as required. 16/25 amp
198Supplying & Fixing following rating double pole ( single phase+ Neutral) 240V, RCCB having asensitive current of 30mA in existingMCB DB complete with connections testing & commissioning ect as required. 40 amp
199Supplying & Fixing following rating double pole ( single phase+ Neutral) 240V, RCCB having asensitive current of 30mA in existingMCB DB complete with connections testing & commissioning ect as required. 63 amp
200Supplying & fixing 20amp 240V, SPN industrial type socket outlet with 2 pole & earth, metal enclosed plug top along with 20amp "C" curve SP MCB in sheet metal encloser in recess/ surface with chained metal cover for the socket outlet complete with connections, testing and commissioning ect as required
201SITC of Gel Earthing with cupper earth plate 600X600X3mm thick including accessories and providing masenary enclosure with cover plate with locking arrangementand watering pipe ect ( with charcole or coke and salt ) as required
202SITC of earthing strip & wire
203Providing & Fixing of 25 X 5 mm CU stripon surface or in recessfor connection ect, as required
204Providing & Fixing of 25 X 5 mm GI stripon surface or in recessfor connection ect, as required
205Providing & Fixing of 6 SWG dia GI wire on surface or in recessfor loop earthing ect, as required
206Providing & Fixing of 50 X 5 mm CU stripon surfacefor connection ect, as required
207Supply of 40KVA on line 3phase UPS
208Supply of MS battery racksuitable for 40/50 KVA UPS
209Recess Mounting LED Light Square Downlight(18/20watt)
210ITC of 40 KVA on line 3 phase UPS
211PART-13 ( SPLIT AC SYSTEM)
212Supply of 1.5 TR 5 star inverter type split units IS:1391 part 1
213Supply of 2TR 5 star inverter type split units IS:1391 part 1
214Supply of following accessories required for installtion of split AC
215Copper tube of size 1/2"for split AC
216Copper tube of size 5/8"for split AC
217Drain pipe for AC
218Outdoor stand for 1.5 TR split AC
219Outdoor stand for 2.0 TR split AC
220PART -14( EPABX)
221Telephone wiring in existing conduit:- Supplying & drawing following pair 0.5 sq mm FR PVC insulated CU conductor unarmoured telephone cable in existing surface/ recessed steel /PVC conduit as required 2 pair
222Telephone wiring in existing conduit:- Supplying & drawing following pair 0.5 sq mm FR PVC insulated CU conductor unarmoured telephone cable in existing surface/ recessed steel /PVC conduit as required 50 pair
223Telephone wiring in existing conduit:- Supplying & drawing following pair 0.5 sq mm FR PVC insulated CU conductor unarmoured telephone cable in existing surface/ recessed steel /PVC conduit as required 20 pair
224SITC of Krone Box 20 pair
225SITC of Krone Box 50 pair
226SITC of EPBX machine with 50 no.s of truck lines , 4 no. lease line , 2 no.s of digital port
227SITC of RJ-11 socket with outlet with modular JB
228SITC of analog telephone
229SITC of intercom distribution phone for 50 no.s lines
230PART -15(CCTV SYSTEM)
231SITC of full HD Dome camera with IR facility for Night vision
232SITC of DVR 32 channel with 6 TB internal storage
233SITC of RJ-6 cable with BNC
234SITC of 32" LED monitor
235PART -16 (FIRE EXTINGUISHERS SYSTEM)
236Water C02 Type 9 Lt. capacity (IS : 940)
237C02 Gas Type 4.5 kg. capacity (IS : 2878)
238ABC Powder Type 6 kg capacity (IS : 13849)
239Supply and fixing of MS round bottom fire buckets of 9 ltrs capacity filled with sand including proper supporting / hanging arrangements in MS fabrication, painted by fire red colour over two coats of primer complete in all respects as per the direction
240PART -17 ( OUTER STAGING FOR REPAIR WORK)
241Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of durationof scaffolding.
242Bricks (5K + 25 P = 30 Kms)
243Stone chips (5 KM+20P=25 KM)
244Cement (3km)
245Coarse Sand(5 KM+20P=25 KM)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail