Repair Maintenance Of D.G. Sets And Sub Station, Fire Fighting And Fire Alarm System Installed At Acharya Shree Bhikshu Govt. Hospital, Moti Nagar, New Delhi ( Sh Replacement Of D.G. Set Exhaust System, Fire Fighting Panel And Various Other Works ) , Acharya Shree Bhikshu Govt. Hospital, Moti Nagar-Delhi

Public Works Department-PWD has published Repair Maintenance Of D.G. Sets And Sub Station, Fire Fighting And Fire Alarm System Installed At Acharya Shree Bhikshu Govt. Hospital, Moti Nagar, New Delhi ( Sh Replacement Of D.G. Set Exhaust System, Fire Fighting Panel And Various Other Works ) . Submission Date for this Tender is 07-08-2021. Fire Alarm Systems Tenders in Acharya Shree Bhikshu Govt. Hospital, Moti Nagar Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

28689528
Repair Maintenance Of D.G. Sets And Sub Station, Fire Fighting And Fire Alarm System Installed At Acharya Shree Bhikshu Govt. Hospital, Moti Nagar, New Delhi ( Sh Replacement Of D.G. Set Exhaust System, Fire Fighting Panel And Various Other Works )
Open Tender
Indian
Delhi
Acharya Shree Bhikshu Govt. Hospital, Moti Nagar
07-08-2021

Tender Details

Repair Maintenance Of D.G. Sets And Sub Station, Fire Fighting And Fire Alarm System Installed At Acharya Shree Bhikshu Govt. Hospital, Moti Nagar, New Delhi ( Sh Replacement Of D.G. Set Exhaust System, Fire Fighting Panel And Various Other Works )

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 16.07 Lakhs /-

BOQ Items

Name of Work: RMO of D.G. Sets & Sub Station, Fire Fighting & Fire Alarm System installed at Acharya Shree Bhikshu Govt. Hospital, Moti Nagar, New Delhi (SH: Replacement of D.G. Set Exhaust System, Fire Fighting Panel and Various Other Works)
Sl. No. Item Description
1Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapor barrier) and finally applying 0.63mm aluminum sheet cladding complete with type3 , grade 1 roofing felt strip (as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. Note: The Pipes of sizes 150mm & below shall be M.S. "C" class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia. and above.
2150mm dia. (50mm thick insulation)
3Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
4Hot finished welded type tubes
5Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
6a)In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
7Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
8Dismantling of MS shade structure from existing location including cutting the wiremesh walls, main pillers in appropriate manner, dismantling of polycarbonate sheet etc. complete with reinstallation of same to a new location etc. as required.
9Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurization pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
10Incomings 630A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich& CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps Outgoings (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 200 Amp, 50kA TPN MCCB, ICS=100% ICU, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets Jockey Pump 100 Amp, 50kA TPN MCCB, ICS=100% ICU, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets
11Diesel Engine Control Control for diesel engine comprising – Automatic/ Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification
12Providing, fixing, testing & commissioning of 15mm diaquartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
13Pendent Sprinkler
14Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
15800 A, 50 KA,TPMCCB
16Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
17Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
18Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
19Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium Conductor armoured power cable of 1.1 KV grade conf. to IS 7098 (Part-I)/ IS 1554 (Part-I) and ISI Marked only of following size on surface as required.
203.5 x 25 Sqmm
212 x 16 Sqmm
22Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Copper Conductor armoured power cable of 1.1 KV grade conf. to IS 7098 (Part-I)/ IS 1554 (Part-I) and ISI Marked only of following size on surface as required.
233 x 6 Sqmm
24Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
25Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
263 X 6 sq. mm (19mm)
272 X 16 sq. mm (22mm)
283½ X 25 sq. mm (28mm)
293½ X 70 sq. mm (38mm)
303½ X 120 sq. mm (45mm)
31Supplying, fixing, testing and commissioning of ultra slim aluminium 22 watt LED lighting fixture with high lumen output, energy efficient, ready to use pack etc complete with connection as required.
32Dismantling and reinstallation of street light feeder piller to a new location complete with connection of all cables etc. as required.
33Supplying, Installation, Testing and Commissioning of factory built floor mounted double skin type horizontal/ vertical air washer/ wet scrubber unit made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.6mm outside layer and 0.6mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with ducted air intake section with suitable flange for duct connection, GI intake louver at inlet of spray section, double bank spray section with spray nozzle, CPVC header, ball valve for water flow control, 18 Gauge SS-304 sump with supply, overflow, quick fill, drain connection. Spray tank will be provided with float valve on makeup like and SS strainer on water suction line for pump. Three phase monoblock pump for water circulation with ball valve. Two bend PVC eliminator to stop carryover of water particles along with air, DIDW centrifugal forward curved fans TEFC squirrel cage induction motor of IE-2 efficiency suitable for 415 ± 10% volts suitable for VFD operation, 50 Hz , 3 phase AC supply. anti vibration mount to avoid transmission of vibration on casing. Fan outlet will be connected with fire retardant, lint free canvass connection, V belt and pulley set for power transmission between motor and fan, complete with all accessories such as make-up, drain, over flow, quick fill valves, float valve, vibration isolators, foundations bolts complete etc. as reqd.
34(i) Capacity 5000 CFM at 50mm static pressure
35SITC of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbow, splitter dampers, vanes, hangers, support etc. as per approved drawings and specifications of following sheet thickness complete as reqd.
36Thickness 0.63 mm Sheet
37Supplying, Installation, Testing & Commissioning of wall mounted three phase DOL Starter 440V 50Hz for company made suitable for 3/5 HP motor complete with all accessories overload relays, contactor, single phase preventer, Ammeters, Voltmeter, auto & manual switch i/c connection etc as required.
38Supplying, fixing, testing and commissioning fire retardant double canvas flexible connections suitable for 5000 CFM capacity ETAC unit complete etc. as reqd.
39Complete servicing of existing on suitable GI frame 22 SWG capacity ETAC Plants / Wet Scrubber units i/c opening the filter section, cleaning of parts with suitable compound like veminclean, greasing, checking/ replacement of packing, nut bolts etc.as reqd.
40Cleaning of 3 nos. kitchen hoods i/c cleaning of the G.I. ducting (200 sqmt. approx.) compete with chemical with the help of high pressure water machine, high pressure steam machine, scrapers etc., removing the heavy carbon, oil/grease from the hoods and ducts and SS baffle type filters, (applying chemical to make hood & duct free from breeding of insects in order to maintain kitchen hygiene, minor repairs etc.) shifting and throwing the scrapped/ removed waste from hospital building to outside the building etc. complete as reqd.
41Supplying & Fixing of following accessories in the existing capacity ETAC after dismantling worn out parts & disposing off the same i/c credit/buy back of old etc.as required.
42V-Belt-B-64
43Providing and Replacement of damaged / broken 200 mm thick (NS) cellulose cooling media/ pads honeycomb type suitable for ETAC unit having capacity upto 4500 CFM at 40 static pressure for different sizes as per site requirement i/c credit/buy back of old etc.as required.
44Supply and replacement of worn out defective metallic viscous pre-air filter, constructed of 5 layers of Al. wiremesh interspaced with 2 crimped layers and 3 flat layers. The media is supported with expended metal from both sides as reinforced and housed in 2” deep Al. frame of 1.6 mm thick and burfi jali of 14 guage on both sides of filters sizes and buyback of the same as reqd at site of following specification: Media – Wiremesh Air flow – 2000 CFM / 4 Sqft Type – Box type Efficiency – 65 to 85% Frame – Al
45Credit buyback of old dismantled material including dismantling etc. as required.
46Rusted MS Pipe/ Angle Iron
47Wornout/ Rusted Fire Fighting Panel
48Burnt 800 Amp MCCB
49Rusted Sprinkler
50Rusted Feeder Piller with accessories
51Conventional Tube Fitting
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail