Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-07-2021 | Tender Date Extend | Date | 03-08-2021 |
| 2 | 27-07-2021 | Minor rectification | Other | 03-08-2021 |
| Sl. No. | Item Description |
| 1 | (A) CIVIL WORK Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000: 1:4:8 (1Cement :4 Course Sand :8 Graded stone aggregate 40 mm nominal size (Crusher Broken) |
| 3 | Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall in :Cement Mortar 1:6 (1-Cement:6-Sand). |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing compaction finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement.All work up to plinth levelIS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size) |
| 5 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level. |
| 6 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidatingeach deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr. |
| 7 | Random Rubble stone masonry for superstructure above plinth level one storey height above 30 Cm. thick walls in : Cement Mortar 1:6 (1-Cement:6-Sand). Extrafor : Wall up to 30 Cm. and less thickness. |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs, girders having slopes up to 15o, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases, up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good and joints excluding the cost of centering, shuttering and reinforcement IS 456-2000: with 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size). |
| 9 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members andremoval of formwork for superstructure up to 4.5 mtr aboveplinth,for: Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands , coping, bed plates, anchor blocks, sills, chhajjas lintel, beam etc. |
| 10 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. Hot rolled deformed bars (IS : 1139) |
| 11 | Supply and fixing Jodhpur sand stone Machine cut Dash, Coping,sill,lintel fixed in cement sand mortar 1:4. (B) 9 cm (3.5\") thick |
| 12 | Supplying and fixing stone liri in CM 1:4 work facing with proper projection and chiesel dressing of edges of stone two line dressing of building corners, jambs etc. including uniform joints using aluminium square section of size 12 mm to 15 mm as per requirement of course and width of stone not less than 12 Cm., with requisite humber headers (minimum length of stone 0.9 M) 14 cm (5.5\")thick. |
| 13 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finished: 20 mm thick. |
| 14 | Deep groove pointing on stone masonry in white cement sand mortar (1:3) with colour pigment of approved shade for all type of masonry incl. racking of joint as per specification complete in all respect. |
| 15 | Half brick masonry in foundation & plinth using bricks of designation 75 with nominal hoop reinforcment (2 Nos. 6mm MS bar) at every fourth course Cement sand mortar 1:4 (1-Cement:4-coarse sand).Add extra for half brick masonary in superstructure up to third story. |
| 16 | Supply and fixing 7 to 10 cm. Soorsagar or equivalent stone chaps in lime mortar or gypsum rough dressed more than 0.60 m. length |
| 17 | Providing and fixing Granite stone slab mirror polished and machine edge cut in Walls, Pillars, Steps, Shelves, Sills, Counters. Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 (1 white cement: 2 marble dust) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing ofIS 3316-1974 : Green/Black/Other granite Above 3601 Cm2 Slab |
| 18 | Extra for providing edge moulding to 18 mm thick marble stone counters, vantities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 19 | Plaster on new surface on walls in cement sand mortar 1:4 including raking of joints etc. complete fine finish:12 mm thick. Add extrafor plaster done over ceiling. |
| 20 | Grading roof water proofing treatment with :Cement concrete 1:2:4 (1-Cement:2-coarse sand :4-graded stone aggregate 20mm nominal size). |
| 21 | Providing and laying 20 to 25 mm size glazed tiles pieces for rooof treatment having colour and shade as approved by the Engineer incharge over 25 mm thick layer of cement mortar mix 1:4 with application of cement slurry including finishing of joints with ordinary cement and curing etc. complete in all respect. Washing with acid. |
| 22 | Providing & laying vitrified Porcelain dianomite floor tile, skirting, dado, size 600x600, 10 mm thick flooring over 20 mm thick bed mortar 1:4 mix with 2-3 mm thick joint to be filled with cementious grout or polymer based non shrink grout of matching colour as per requirement of site. |
| 23 | Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20x10x2mm and brackets with flat iron diagonals 20x5mm, size with top and bottom rail of T-iron 40x40x6mm, with 40 mm dia steel pulleys / ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). IS 10521-1983. With 100 mm opening when closed. |
| 24 | Providing & fixing anodizing alumium work (Anodizing to be got done from approved Anodizer) for doors, windows, ventilators and partition with extruded built up standard tubular and other sections of approved make confirming to IS : 733 and IS : 1285 anodised transparent 81 dyed to required shade according to IS : 1868 (Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gas at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required inlcuding cleat angle Aluminum snap beading for glazing/paneling, C.P. Brass/ Stainless Steel screws, Al. Tower bolt & Al. handle & Al. Aldrop etc. all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and peneling to be paid for separately).For Fixed portion |
| 25 | For shutters of doors, windows & ventilators incl. providing and fixing hinges/ rollers etc. and making provision for fixing of fittings wherever reqd. (lockes shall be paid for separately). |
| 26 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVS/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost. of aluminium snap beading shall be paid in basic item.) With glass panes of 5.0mm thickness (weight not less than 13.75 Kg/Sqm) as per IS : 2835 |
| 27 | P&F expanded grill made of anodised aluminium as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminium window/ vent with reqd. screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. |
| 28 | Supplying & Fixingfixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws at not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 29 | Providing and Fixing 12mm thick prelaminated three layer medium density (exterior grade) particle board Grade-I, Type-II confirming to IS 12823 bonded formaldehyde synthetic resin of approved brand and manufacture in paneling fixed in aluminium doors, windows/ stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 30 | Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete |
| 31 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work including preparation of base with primer, & touching of existing putty, lippy complete in all respect |
| 32 | Painting with enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 33 | Painting with weather coat paint (Asin paint/ I.C.I./Berger or eq. ISI make paint) two or more coat to give an even shade on new work. |
| 34 | Providing and fixing brass lock without handle for aluminium door, or approved quality, make & design as directed by Engineer incharge |
| 35 | Providing and Fixing hydraulic door closure ISI marked IS 3564-1995. |
| 36 | Providing and fixing Ist quality MAT finished ceremic tile size 300x300mm confirming to IS : 13753 colour such as white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slsurry including nicely finished joints using water proof joint filler power and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). Add extra for floor work due to extra cost of cement mortar 1:4 (1-Cement:4- fine sand) 20 mm thick. |
| 37 | Providing and fixing Ist quality standard White Ivory Glazed Tiles ISI marked [IS:13753] of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster). Category-I. |
| 38 | P & F European type white glazed vitreous china Ist quality W.C. pan (IS:2556 Mark) with P or S trap including cutting and making good the wall and floor. |
| 39 | P & F water closet Seat Covers with brass hinges completeIS 2548-1996 : Solid PVC (ISI marked) grade-I White for EWC. |
| 40 | P & F Ist quality WVC Urinal (IS:2556 mark) with 25 mm dia G.I. waste pipe, dome couplings, concealed iron brackets or screws etc. complete. Flat Back (large) or half stall size 590x375x390 mm. |
| 41 | P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : PVC with PVC bend as per IS : 7231 |
| 42 | P & F C.P. brass Urinal Spreader for stall urinal of approved make. |
| 43 | P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 25 mm G.I. waste pipe complete including cutting & making good the wall :Size 530 mm x 450 mm |
| 44 | P & F kitchen & Lab Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up to floor level complete including cutting and making good the wall & floorIS 771 (Part-II) -1985.1.0mm thick salem stainless steel AISI -304 kitchen sink of approved make with large waste coupling. Size 24x18x820x16x8 |
| 45 | P&F looking mirrors with PVC frame of approved ISI make. Size 500x400mm |
| 46 | P&F towel rail or ring of approved quality /make: C.P. brass towel rail with bracket 600 x20mm. |
| 47 | P&F Grating of approved quality/ make Stainless steel sheet Heavy quality of approved make 125mm |
| 48 | P&F Soap dish or tray of approved quality/ make. C.P. brass |
| 49 | P&F Jet spray for water closet with C.P. copper tube flange of approved make |
| 50 | P & F G.I. Pipes (Internal work) with G.I. fittings (IS:1239 Mark) & M.S. clamps including cutting and making good the walls and floors : (a) Exposed on wall (A) 15 mm dia nominal bore.\"B\" Class |
| 51 | (B) 25 mm dia nominal bore.\"B\" Class |
| 52 | Making connection of G.I. distribution branch with G.I. main including all fitting. Beyond 25 mm & up to 100 mm dia. |
| 53 | P & F Bib Cock (IS:8931 Mark) Superior quality of approved make : (A) C.P. Brass bib cock, 15 mm nominal bore. |
| 54 | P & F Stop cock (IS:8931 Mark) superior quality & of approved make : C.P. Brass 15 mm nominal bore. |
| 55 | P & F Sink Cocks of superior quality & approved made: C.P. Sink cock swinging spout 15 mm. |
| 56 | P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete : Brass wt. 400 gm, 15 mm. |
| 57 | P & F 15 mm. Dia Connection pipe of approved quality/make: PVC pipe with C.P. Brass nuts 450 mm. |
| 58 | P & F Full-way valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 15 mm nominal bore. |
| 59 | P & F Full-way valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 25 mm nominal bore. |
| 60 | P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design. 1000 litres capacity. |
| 61 | Hoisting Charges for each floor : For item 2.26.5 to 2.26.8 |
| 62 | P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant (A) 75mm dia |
| 63 | (B) 110mm dia |
| 64 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:(A)Plain Tee 110mm dia |
| 65 | (B) Door Tee 110mm dia |
| 66 | (B) Bend 45 110mm dia |
| 67 | (D) Bend 87.5 110mm dia |
| 68 | (F) Door Bend (top side) 110mm dia |
| 69 | (G) Vent Cowel 110mm dia |
| 70 | (H) Pipe clip 110mm dia |
| 71 | (I) Plain floor trap 110mm dia |
| 72 | Construction of manhole in all type of soil inner size 90 X 60 Cm. thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring,making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C.flooring , 25 Kg. CI cover with frame of 40mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth upto 0.5mtr |
| 73 | Construction of soakage well in all type of soil 300 mm thick dry masonry top and bottom 300 mm course in CM 1:6, 80 mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring, earth work complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 300 Cm. dia outside & 300 Cm. depth. |
| 74 | Construction of chamber in all type of soil with 300 mm thick masonry in Cm 1:6 m 100mm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm upto depth of 0.5m & 15Kg CI cover with frame |
| 75 | Clearing and grubbing road landincluding uprooting rank vegetation, grass, bushes, shrubs, saplingsand trees girth upto 300 mm, removal of stumps of trees cut earlierand disposal of unserviceable materials and stacking of serviceable material upto a lead of 1000m including removal and disposal of top organic soil not exceeding in 150 mm thickness as per MORTH specification clause 201 By mechanical Means . A. In area of light jungle |
| 76 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1-Cement:3-coarse sand) and making good the joints excluding cost of centering shuttering and reinforcement IS 456-2000: 1:1.5:3 (1-Cement:1.5 coarse sand:3-graded stone aggregate 20 mm nominal size). |
| 77 | Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways with wooden members andremoval of formwork for superstructure up to 4.5 mtr aboveplinth,for: Columns, pillars, posts and struts etc. |
| 78 | Construction of un-reinforced, dowel jointed, plain cement concrete pavement (M-30 grade) over a prepared sub-base with 43 grade cement @ 400 Kg per cum , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 31.5 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrance, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing complete as per MoRTH specification clause 602. |
| 79 | Supplying and fixing of rolling shutters of approved make, made of 80x1.25mm ms laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangments for in side and out side locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3 cm long wire spring grade No 2 and ms top cover 1.25 mm thick for rolling shutters as per design(Clear openable area to be measured for payment.) IS 6248-1979. |
| 80 | Providing & fixing steel glazed doors, windows and ventilators shutters of standard rolled steel section joint mitred and welded with steel 13x3mm lugs 10 Cm. long embedded in cement concrete blocks 15x10x10 Cm. of 1:3:6 (1-Cement:3-coarse sand:6-graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of plain glass panes 4mm thick with copper glazing clips and special metal-sash putty of approved make, or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings except necessary hinges of pivots steel handles and peg stay etc. as required. IS 1038-1983.windows side hung (Openable) |
| 81 | Providing and fixing angle iron frame 25x25x3mm for ventilators with fixed wire gauge 16 mesh 24 gauge including 100 mm square bars at interval of 100 mm welded screwed to frame with metal beading 20x3mcomplete in all respect as per design. |
| 82 | Providing and fixing Square bars or other flat welded to window, ventilators etc. |
| 83 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance. |
| 84 | White washing with lime to give an even shade including all scaffolding IS 6278-1971 : New work (three or more coats) |
| 85 | Providing & fixing Self Supported truss less roof system using Base Metal of Cold Rolled Structural Quality Steel Sheets ofof min. grade D- 350 Mpa yield strength(as per ASTM A -792) having Base Galvalume Coating of AZ 150, 150 gms/sqm including fabrication, panel formation, mechanical sealing and erection with proper provision of skylight, hangers, turbo ventilator exhaust system, anchoring with RCC gutter Beams etc complete in all respect as per manufacturer\"s specification and direction of Engineer-in-charge (excluding cost of skylight,turbo ventilator exhaust&RCC gutter beams) For BMT of 1.00 mm |
| 86 | P&F rigid PVC Pipe (IS:4985 mark) class II(4 Kg. /Cm.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant 160mm dia |
| 87 | Providing and fixing ball bearing for rolling shutters |
| 88 | Add extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 10.0 Sqm and upto 16.80 Sqm in the aera |
| 89 | Extra for subsequent storey or height of 4.5 Mtr. or part thereof for all masonary work. Quantity in Cum. |
| 90 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 91 | Add extra for plaster work on exterior wall of height more than 4.5M. from plinth level of every additional height of 4.5 Mtr. or part thereof. |
| 92 | Add extra for Centering and shutteringevery additional 1 m ht. Or part thereof beyond 4.5 mtr. of shuttering. |
| 93 | Providing and fixing set of skylight (2\"x7\") and turbo ventilator exhaust system (24\") for Self Supported truss less roof system |
| 94 | Providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finished with cement mortar 1:3 as per standard design. |
| 95 | (B) ELECTRIC WORK Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / lamp Holder/ 3 pin connector , screws etc, making connections,all as per pre approved by Engineer in charge, testing etc. complete as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07 . For additional technical parameters of products/ work, referAnnexure \"A\" attached with this BSR . |
| 96 | (A) Short point (up to 3 mtr.) |
| 97 | Medium point (up to 6 mtr.) |
| 98 | Long point(up to 10 mtr..) |
| 99 | Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & it\"s all accessories( J.B. , Bends etc.) , round tiles, 18 SWG Hot Dipped Galvanized Modular Box with earth terminal, 6 A modularswitch, 3/ 5 pin 6 A modular socket, Modular face plate with grid plate, screws etc,all as per pre approved by Engineer in charge,making connections, testing etc. complete as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 100 | On board |
| 101 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, referAnnexure \"A\" attached with this BSR . |
| 102 | MMS ( IS:9537 P - III ) PVC conduit |
| 103 | (A) 25 mm |
| 104 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.99% purity copper, class 5 stranding in acc. to IEC 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4,, in existingsurface or recessed PVC/ MS conduit/casing capping includingall as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work, referAnnexure \"A\" attached with this BSR . |
| 105 | (a) 2 x 1.5 sq.mm |
| 106 | (b) 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 107 | (c) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 108 | (d) 4 x 10.0 sq.mm |
| 109 | Providing & Fixing of surface/recessed type 10 mm thickwood board duly antitermite treated, varnished and fixed by using gutties/ PVC fasteners of following size as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 110 | 300 mm x 375 mm |
| 111 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load andsite requirement) 4KV impulse withstand voltage,as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted withexisting distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A ratingincluding making connections, testing etc. as required.. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 112 | Single pole MCB |
| 113 | 6 A to 32 A rating |
| 114 | Four pole MCB |
| 115 | 50-63 A rating |
| 116 | Providing & Fixing of 240/415 V isolator as per PWD specification for electrical Works with ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm. , label holding facility , IP 20 contact protection and fitted with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 117 | Four pole Isolator |
| 118 | 80 A/ 100 A rating |
| 119 | Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thickDistribution board as per PWD specificationfor electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DBterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 120 | IP-43 Double door (Three phase) |
| 121 | 6 Way ( 18 O/G + 8 I/C ) |
| 122 | Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling roses as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 123 | Providing & Fixing of ISI marked (IS:1258)6 ampbatten/angle lampholder as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 124 | Providing & Fixing of ISI marked (IS:2268-1994) single / multi tone electronic call bell as per PWD specification for electrical Works, including making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 125 | Providing & Fixing of modular type Step Fan regulator duly ISI marked (IS :11037) as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR |
| 126 | 5 step fan regulator 100 watt 2 Module |
| 127 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) [ as per detailed in respective item in BSR] , making connection , testing , etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 128 | SITC of IP 40quick make and quick break4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings as per PWD specification for electrical Works, conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 800 V, provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections with lugs & spreaders,etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 129 | With Thermal Magnetic release |
| 130 | 160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu |
| 131 | Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/IS-8623 & IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31,front openable bus bar made out of Coppersuitable for 200 amp. Capacity, bus barfixed on porcelain/DMC insulators at approved spacingincluding making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 132 | 450 mm long , 4 strip |
| 133 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- |
| 134 | (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I |
| 135 | (b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures . |
| 136 | (c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 137 | Armoured Cable |
| 138 | 70.0 Sq. mm 4 Core |
| 139 | Labour charges for Excavation of 30cmx75cm size trench in loose soil including refilling of excavatedearth,compaction of earth, making good the same complete as required . |
| 140 | Supplying and makingend termination with heavy aluminiumlugs Pin / ring type (as per IS 8309 -1993 & IS 8337-1976 ) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc of following size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 141 | 70.0 Sq.mm |
| 142 | SITC ofchemical Gel earthing system ofDual Pipe Technology made of with \"B\" ClassG I Pipeas per IS 1239 ( part-1):2004of Medium duty of following sizesas per points mentioned (a), (b), [c), (d), (e) below :- |
| 143 | (a) filled with anti corrosiveconductivecompounds with the permanent sealings at both the ends, CPRI/ ERDAtested with RMS capacity of minimum 35- 40 KA for withstanding 1 second . |
| 144 | (b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL acredeated labfor lowresistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major contentas per referance of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendemnts |
| 145 | ©Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. |
| 146 | (d)Testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. |
| 147 | (e) Self certificate for confirming above standards from OEM is mandatory. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 148 | With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell |
| 149 | GI pipe 2000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip |
| 150 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cuthimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .8 SWG copper Wire |
| 151 | 8 SWG copper Wire |
| 152 | Supply & Laying following size\" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 153 | 80 mm dia. |
| 154 | Providing & Fixing of ISO Certified company made BEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanas per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V- 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 155 | 1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) |
| 156 | Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. OEM shall be an ISO certified company.Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 157 | 225 mm sweep |
| 158 | Providing & Fixing ofISO Certified company made ISI marked (IS:2082) of 5 star ratedvertical storage water heater with outer casing made of M.S.sheet finished with anti-corrosive powder coating,inner tank made of pure electrolytic copper/stainless steel / SPHP, Tubular copper sheathed and Nickel plated heating element/ twin ceremic cartridge heating element, stem type thermostat and thermal cut out, Dual indicating lamps for power supply and thermostat, PUF insulation, Pressure release valve,fusible plug etc. as required held in position with 4 no. rag bolts,duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top with Portable Residual Current Device ( PRCD ) facility form OEM ,including making inlet,outlet heavy gauge C.P./ Flexible alloyconnection,testing etc. complete in all respect. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 159 | 6 Ltr. |
| 160 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coatedhousing with in built driver, Power Consumption of18W/20W ,system lumen efficacy = 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.=0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. |
| 161 | OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \"A\" attacheded with this BSR. |
| 162 | 4\" LED Tube shape fixture 18/20 W (Polycarbonate Base) |
| 163 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be usedand potted driver must be potted & has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <1000mA shown in LM79 report. The luminaireshall be BIS certified and T.C. certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min = 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. |
| 164 | OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 165 | LED Street Light fixture120 Watt |
| 166 | Providing & Fixing of Street light bracket made out from following size of \" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 167 | 40 mm Dia. |
| 168 | Supply & Fixing of ABC Type (MAP 50)type powder Fire Extinguisher (Stored Pressure type) of following capacity duly current and valid BIS certification conforming to IS: 15683:2006, withDry chemical powder used as extinguishing agent should be Mono Ammonium Phosphate 50% concentration conforming to IS 14609:1999. OEM will produce supplier certificate complete with squeeze grip release valve, locking arrangement, pressure gauge and bracket includinginitial fill and wall suspension complete in all respect. Serial no. and date of manufacturing should be embossed or printedon the body of the fire extinguisher. The firm should submit the product certificate from an EN notified body & product performance test report from NABL accredited Lab as per IS 15683. . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . |
| 169 | 6 kg |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy