Supply Of Miscellaneous C And I Items For 200Mw Units, Btps, Obra , Thermocouples K-Type ( Duplex Type, Mineral Insulated ) With Head, Length 400 Mm, Stem Dia9.0 Mm , Connection½ Bsp ( M ) Thread, Adjustable Compressionfitting With Suitable Thermo Well , Insert Length-150 Mm, Material Ss-316, Thermo Well Minimun Thickness- 3Mm, Od-19 Mm, Outer Thread- 1 Bsp ( M ) .Make -Detrive / Rajput / Temcon , K-Type Thermocouple ( Od 6Mm ) With Mi Capillary With Head, Duplex Type, Length : 320Mm , Connection½ Bsp ( M ) Thread , Adjustable Compressionfitting.Make -Detrive / Rajput / Temcon , K-Type Without Head Connection Thermocouple For Boiler / Turbine Metal Temp. Measurement Mineral Insulated Ss-316 Duplex And Capillary Length :10 Mtr ( Od 6Mm ) . Make -Detrive / Rajput / Temcon , K-Type Without Head Connection Thermocouple For Boiler / Turbine Metal Temp. Measurement Mineral Insulated Ss-316 Duplex And Capillary Length:15 Mtr ( Od 6Mm ) . Make -Detrive / Rajput / Temcon , K-Type Without Head Connection Thermocouple For Boiler / Turbine Metal Temp. Measurement Mineral Insulated Ss-316 Duplex And Capillary Length : 5 Mtr ( Od 6Mm ) . Make -Detrive / Rajput / Temcon , K-Type With Head Connection Thermocouple For Boiler / Turbine Metal Temp. Measurement Mineral Insulated Ss-316 Duplex And Capillary Length :10 Mtr ( Od 6Mm ) . Make -Detrive / Rajput / Temcon , K-Type With Head Connection Thermocouple For Boiler / Turbine Metal Temp. Measurement Mineral Insulated Ss-316 Duplex And Capillary Length :15 Mtr ( Od 6Mm ) . Make -Detrive / Rajput / Temcon , K-Type With Head Connection Thermocouple For Boiler / Turbine Metal Temp. Measurement Mineral Insulated Ss-316 Duplex And Capillary Length :5 Mtr ( Od 6Mm ) . Make -Detrive / Rajput India / Temcon , Pt. Pt. Rh 10% ( S-Type ) Thermocouple For Flue Gastemperature Measurement With Protection Sheaths Ss-316, Od-19Mmand Adjustable Male And Female Flange Set With Washer And Nut Both, Length 1000 Mm, Outer Shelth Thickness- Min 3Mm. Make -Detrive / Rajput / Temcon , Temp Switches And Gauges. Anti Vibration Type Dial Thermometer, Dial Size 150Mm, Connection½bsp ( M ) Threadadjustable Compressionfitting , Bottom Entry, Steam Length 400Mm , Stem & Bulb Dia 9 Mm, Stem And Bulb Material Ss-316.: Range : 0-4000 C. Make: H-Guru / Gic / Tiwac. , Temp Switches And Gauges. Anti Vibration Type Dial Thermometer, Dial Size 150Mm, Connection½bsp ( M ) Threadadjustable Compressionfitting , Bottom Entry, Steam Length 400Mm , Stem & Bulb Dia 9 Mm, Stem And Bulb Material Ss-316.: Range : 0-2500 C. Make: H-Guru / Gic / Tiwac. , Temp Switches And Gauges. Anti Vibration Type Dial Thermometer, Dial Size 150Mm, Connection½bsp ( M ) Threadadjustable Compressionfitting , Bottom Entry, Steam Length 400Mm , Stem & Bulb Dia 9 Mm, Stem And Bulb Material Ss-316.: Range : 0-1500 C. Make: H-Guru / Gic / Tiwac. , Temp Switches And Gauges. Anti Vibration Type Dial Thermometer, Dial Size 150Mm, Connection½bsp ( M ) Threadadjustable Compressionfitting , Bottom Entry, Steam Length 400Mm , Stem & Bulb Dia 9 Mm, Stem And Bulb Material Ss-316.:Range : 0-1000 C. Make: H-Guru / Gic / Tiwac. , Temp Switches And Gauges. Bimetallic :- 0 – 1500 C For Bowl Mill Oil Temperature Measurement, Stem Length 175 Mm, Stem And Bulb Dia 06Mm, Connection½ Bsp ( M ) Thread Adjustable Compressionfitting, Bulb And Stem Material : Ss-316, Dial Size 100 Mm.Make: H-Guru / Gic / Tiwac , Temp Switches And Gauges. Dial Gauge Type Temperature Switches For Bfp Working Oil Outlet Temperature Range 0-150 0C, Capillary Length3 Meter And Od 6 Mm With Flexible Pvc Conduit, Bulb Length- 120Mm, Bulb Dia- 10.0 Mm , Dial Size 150Mm With ½ Bsp ( M ) Compression Adjustable Fitting And Double Contact ( No ) .Make: H-Guru / Gic / Tiwac , Temp Switches And Gauges . Dial Gauge Temperature Switches For Id , Fd And Pa Fan Lube Oil Temperature Range 0-1200 C, Capillary Length10 Meter And Od 6 Mm With Flexible Pvc Conduit, Bulb Length- 240Mm, Bulb Dia- 10.0 Mmdial Size 150 Mm With ½ Bsp ( M ) Compression Adjustable Fitting & Double Contact ( No ) . Make: H-Guru / Gic / Tiwac. , Temp Switches And Gauges .Dail Gauge Type, 0-1500 C For Bfp Brg. Temp. ( For Voith Hydraulic Couplings ) Switch, Capillary Length5 Meter And Od 6 Mm With Flexible Pvc Conduitdail Size 150 Mm With ½ Bsp ( M ) Compression Adjustablefitting And Stem Dia 10 Mm, Length 120 Mm With Single Contact ( No ) . Make:H-Guru / Gic / Tiwac. , Temp Switches And Gauges .Temp Gauge 0 To 200 0C Capillary Length 5 Mtrsand Od 6 Mm With Flexible Pvc Conduit , Dail Size 150 Mm With Adjustable Male And Female Flange Set With Washer And Nut Both And Stem & Bulb Dia 10 Mm, Length 240 Mm.Make: H-Guru / Gic / Tiwac. , Mtm Pad , Id- 6.20Mm, Metal Ss-316 , Rtd ( Prt-100 Ohm ) , Thermocouple Type Along With Thermowell, Head Connection ( Ss-316 ) With 320Mm Length Duplex Type, Bulb Dia 06Mm, Connection ½ Bsp ( M ) Thread Adjustable Compression Fitting.Make-Detrive / Rajput / Temcon. , Rtd ( Prt-100 Ohm ) , Thermocouple Type Along With Thermowell, Head Connection ( Ss-316 ) With 1000 Mm Length Duplex Type, Bulb Dia 12 Mm, As Per Standard And Adjustable Male And Female Set With Washer And Nut Bolt. Make-Detrive / Rajput / Temcon. , Rtd ( Prt-100 Ohm ) , Capsule Type, Duplex Length 20 Mm And Od4 Mm.Make-Detrive / Rajput / Temcon. , Stub For Steam / Water Line Sh / Rh / Mill, Id- 1 Bsp ( F ) . , Thermowell For Steam / Water Line, ½Bsp Inner Thread, 1 Bsp Outer Thread, Material- Ss-316, Insert Length- 150Mm, Id-12 Mm, Min Thickness- 2Mm.