Augmentation of Existing Water Supply Scheme Aima Kalan & Aima Khurd (MH/PC),Block Gandiwind, Distt. Tarn Taran. Under Nabard-XXIII. (PRWSS-W-DIV09-8257-1)Part A :- Providing & Installing deep tubewell 200 mm i/d straight 150 mtr depth with 15 mtr stainle, Distt. Tarn Taran-Punjab

Water Supply And Sanitation Department-WSSD has published Augmentation of Existing Water Supply Scheme Aima Kalan & Aima Khurd (MH/PC),Block Gandiwind, Distt. Tarn Taran. Under Nabard-XXIII. (PRWSS-W-DIV09-8257-1)Part A :- Providing & Installing deep tubewell 200 mm i/d straight 150 mtr depth with 15 mtr stainle. Submission Date for this Tender is 23-08-2021. Conductor Tenders in Distt. Tarn Taran Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

28613517
Corrigendum : Augmentation of Existing Water Supply Scheme Aima Kalan & Aima Khurd (MH/PC),Block Gandiwind, Distt. Tarn Taran. Under Nabard-XXIII. (PRWSS-W-DIV09-8257-1)Part A :- Providing & Installing deep tubewell 200 mm i/d straight 150 mtr depth with 15 mtr stainle
Open Tender
Indian
Punjab
Distt. Tarn Taran
23-08-2021

Tender Details

Augmentation of Existing Water Supply Scheme Aima Kalan & Aima Khurd (MH/PC),Block Gandiwind, Distt. Tarn Taran. Under Nabard-XXIII. (PRWSS-W-DIV09-8257-1)Part A :- Providing & Installing deep tubewell 200 mm i/d straight 150 mtr depth with 15 mtr stainless strainer with hand boring, Pumping machinery, Chlorinator, const. Pump Chamber with WC & Gravel Pit, Construction of one No. OHSR 50 KL capacity having height 20.00mtr up to FSL including the cost of inlet, outlet, overflow and scour and vertical pipe, CI duck foot bends, expansion joints, puddle collar, lightening conductor, earthling, MS steel ladder of tank portion stair case with G.I pipe Aluminum ladder inside OHSR, scour/overflow sluice valves and making connection with rising main and distribution pipe line, All civil works, supplying and laying PVC pipes, sluice vales and special for rising main and distribution system etc. House hold connection, Development of water works, etc. complete in all respects. Part B :- Operation & Maintenance of scheme for (Three Months) after execution of the work at site including salary of pump operator-Cum Chowkidar, Energy charges and providion of sodium hypo-chloride for disinfection of water with Electricity bill, etc.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Aug-2021 Date extend Corrigendum 1 Date 12-08-2021
2 13-Aug-2021 Date extend Corrigendum 2 Date 23-08-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 83280.0 /-
Tender Value
INR 41.64 Lakhs /-

BOQ Items

Name of Work :- Bid Document for Augmentation of Existing Water Supply Scheme Aima Kalan & Aima Khurd (MH/PC),Block Gandiwind, Distt. Tarn Taran. Under Nabard-XXIII. (PRWSS-W-DIV09-8257-1) Part A :- Providing & Installing deep tubewell 200 mm i/d straight 150 mtr depth with 15 mtr stainless strainer with hand boring, Pumping machinery, Chlorinator, const. Pump Chamber with WC & Gravel Pit, Construction of one No. OHSR 50 KL capacity having height 20.00mtr up to FSL including the cost of inlet, outlet, overflow and scour and vertical pipe, CI duck foot bends, expansion joints, puddle collar, lightening conductor, earthling, MS steel ladder of tank portion stair case with G.I pipe Aluminum ladder inside OHSR, scour/overflow sluice valves and making connection with rising main and distribution pipe line, All civil works, supplying and laying PVC pipes, sluice vales and special for rising main and distribution system etc. House hold connection, Development of water works, etc. complete in all respects. Part B :- Operation & Maintenance of scheme for (Three Months) after execution of the work at site including salary of pump operator-Cum Chowkidar, Energy charges and providion of sodium hypo-chloride for disinfection of water with Electricity bill, etc.
Sl. No. Item Description
1Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tubewellis lowered & tested, equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect.
2(c) Boring with 250mm id Housing Pipe 0 to 150 m
3Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
4(d) 200 mm nominal diameter (weight 41.6 kg per meter) 8 mm thickness
5Supplying, fixing & lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest ISI marked Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
6(i) 200 mm steel starainer (slot size 0.15mm)6.30 mm thickness
7Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect.
8(c) 200 mm internal diameter
9Supplying, Lowering & fixing of stainless steel socket as per IS 8110-2000 or latest ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into T/Well borecomplete in all respect.
10( b)200 mm i/d
11Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
12Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis)
13Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect
14(c) 200 mminternal diameter
15Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
16(c) 200mm internal diameter (weight 41.6 kg per meter) 8.00 mm thickness
17Supplying & fixing of M.S. Clamp of size 200mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
18Development of stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
19(a) Capacity of Air compressor 300 cfm at 250 PSI
20Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
21Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
22Constructionof One No. RCC OHSR having capacity 50KL (50,000 ltrs) height 20 mtr. up to FSL & 17.00 mtr. up to sill level from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single man hole cover lightening conductor, aluminium ladder inside tank portion etc. complete as decribed in schedule No. 3. Providing & fixing CI/D/F expansion joint conforming to IS -1536-1989 or latest and bail mouth and D/F puddle collars as per DWSS design, Duck foot bends conforming to ISI-13382 and CI/DF sluice Valve duly ISI marked ( IS 14846-2000 or latest) one each with inlet, outlet and scour pipes including providing and installing intel, outlet, scour pipes and overflowDI double flanged pressure pipes horizontally as per IS 8329-2000 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification.TMT steel and painting of all complete shall be included in cost complete in all respect as per specifications. (The specification & drawing are based on safe bearing capacity of soil of 8.75 tones per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per sqm. the contractor shall submit his own design for foundation portion based on actual safe bearing standard capacity as per DWSS specifications. The difference in quantites from the standard drawing based on 8.75 tone per sqm. to the safe bearing capacity will bepaid as per CSR+prevalling celling premium). It also includs, providing & fixing automatic Electronic water level control device and construction of Plinth protection around OHSR with masonary toe wall with 40mm thick CC 1:2:4 on top over 100mm thick CC 1:8:16 & inside earth filling including overflow haudi complete in all respects.
23Providing, Laying , fixing & jointing ofP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications
24110mm o/d pipe of 10 Kg/cm2 lines laidcomplete
25Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
26100mm i/d
27Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete
28Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health departmentsize 0.6m x 0.6m Including Carriage
29Providing, Laying , fixing & jointing ofP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (Manually) (6kgf/cm2) (excavation & including specials)
30PVC pipe 63mm o/d
31PVC pipe 90mm o/d
32Providing, Laying , fixing & jointing ofP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (Mechnically) (6kgf/cm2) (excavation & including specials)
33PVC pipe 63mm o/d
34PVC pipe 90mm o/d
35PVC pipe 160mm o/d
36Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
37PVC pipe 63mm o/d
38PVC pipe 90mm o/d
39Dismentalling of Mettaled roads and back filling with excavated earth and fully compacted only
40PVC pipe 63mm o/d
41PVC pipe 160 mm o/d
42Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
4380mm I/d
44150mm I/d
45Providing, Fixing & jointing ISI Marked Gun-metal peet valve(Heavy pattern) as per IS 778 with hand wheels,on Gi pipe line laid in the ground or inside building includingcarriage complete in all respects. 50mm i/d Gun metal peet valve heavy pattern
46Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages completein all respects
47Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department of Size 0.6m x 0.6m Including Carriage
48Bailing out water from the trenches for making new connections in existing pipe lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in- Charge including cost of specials9PVC to PVC)
49Providing & Fixing One No. Bulk Meter inside pump chamber inlcluding rubber joint, nut bolt and other required accessories code 4064-2005 complete in all respect
50Providing proposed water connection withto household up to Wall with providing, laying, jointing, testing GI pipe lines 15 mm i/d = 2.50 mtr. , B-Class as per CSR 28.36 (A) , (Above ground level) , Providing & fixing MDPE pipe 15 mm i/d with specials 2.00 mtr. (Below GL), including cost of special such as tees, bends, sockets, elbow, peet valve, union, nipples and hocks etc, cutting, threading and testing in trenches in the ground and ISI 15 mm i/d GM ferrule as per IS" 2692 and 3" i/d clamp with C..I. bib cock, 15 mm i/d as per IS " 210 with stainless steel spindle of approved make as per CSR 30.65 (b) Complete in all Respect
51Providing & Installing Testing & Commissioning of One No. Electrically driven diaphragm opreated metering system chemical dosing chlorinator suitable for for delivering 0.5 to 6 liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg/cm2 and suction left not less than 1.5 mtr., as per DWSSstandard specifations.
52Construction of Pump Chamber size 3.05 x 3.70 mtr. with toilet block with Gravel Pit and Ceiling Fan, including cost of Electric wiring & sanitary installations as per standar designcomplete in all respect. Including Carriage
53Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 377 LPM against a head of 70 mtr along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including G.I. Column Pipe of suitable size 80 mm =50 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (reputed make) complete in all respects as per standard Specifications. ( 4 star rating)
54Cost of pumping set 377 LPM Head 70 mtr.) excluding cost of old machinary
55Cost of lowering (with length) G.I Column Pipe 80 mm i/d
56Cost of submersible cable (with length) 4mm² B-class
57Cost of pannel board
58C.I FITTING OUTSIDE PUMP CHAMBER Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects
59Development of Water Works
60Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing . (including carriage)
61Providing & fixing PCC fencing poles with 6" height 3"x3" top & 4"x3" base providing with 3 Nos. hooks complete in aii respects.
62Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing . (including carriage)
63Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing . (including carriage)
64Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including& Analysiscomplete in all respects (including carriage)
65Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7. (including carriage)
66Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-20 (including carriage)
67Environmental
68Making lawns including ploughing & dragging with "Sohaga" breaking of clods, removal of earth rubbish dressing & Supplying doob grass roots and planting at 15 cm. apart including Supplying and spreading of farm yard manure@ 0.18 cum per 100 sqm & loosening.
69Supplying and Planting prmanent trees including digging of eirth pits size 75x75x75 cm deep refilling the excavated eirth with manure supplyed @0.113cum each and watring supplying through tractor tanker(trees like Neem, Ashoka, Dake, arjun etc.)
70Planting ground cover plants including digging and refilling of beds with excavated soil and FYM, Fertilizer and insecticides, planting of saplings at 30cm distance from plant to plant and row to row, providing and fixing brick tiles edging.
71Planting, flower beds including digging and refilling of beds with excavated soil and FYM, fertilizer and insecticides, plating of sapling at 30cm distance from plant to plat and row to row.
72Provision for one way stand post with khura complete in all recpect as per standard design drawing.
73Part B Operation & Maintenance of scheme for (Three Months) after execution of the work at site including salary of pump operator-Cum Chowkidar, Energy charges and providion of sodium hypo-chloride for disinfection of water with Electricity bill, etc.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail