| 1 | 1 | List of item(s) / work(s) as per tender documents | | | |
|---|
| 2 | 10 | SUPPLY OF MMO ANODES- CANISTER PRE PACKED IN COKE BACKFILL FOR CATHODIC PROTECTION\nSIZE: 25MM DIA X 1500MM LENGTH | Item10 / 7710209022 | 4 | EA |
|---|
| 3 | 20 | PERMANENT REFERENCE ELECTRODES CU/CUSO4 CUM ZINC WITH POLARIZATION COUPOUN FOR CATHODIC PROTECTION | Item20 / 7710209032 | 3 | EA |
|---|
| 4 | 30 | Anode tail cable - 1Cx 10 sq.mm copper cable suitable for Cathodic Protection for MMO anode to AJB. | Item30 / 7731581252 | 500 | M |
|---|
| 5 | 40 | Header cable - 1Cx35sq.mm copper cable suitable for Cathodic Protection | Item40 /7731582752 | 500 | M |
|---|
| 6 | 50 | SFI OF GI CABLE TRAY (INCL. COST OF\nTRAY) Supply ,fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and / or fix to steel / RCC columns, beams, or any other structure members with MS suspenders, angles, channels etc. complete as per the direction of Engineer-in-Charge 100 mm x 25 mm x 2 mm | Item50 /CEL0100901 | 50 | M |
|---|
| 7 | 60 | STRUCTURAL STEEL WORK RIVETTED OR BOLTED IN BUILT UP SECTION\nStructural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including supply of all material & labour, transportation etc.\n | Item60 / CEL1004000 | 40 | KG |
|---|
| 8 | 70 | STRUCTURAL STEEL WORK WELDED IN BUILT UP SECTION\nStructural steel work welded in built up sections, trusses and framed work, including cutting, hoisting,\nfixing in position and applying a priming coat of approved steel primer all complete including supply of\nall material & labour, transportation etc \n | Item70 / CEL1004100 | 30 | KG |
|---|
| 9 | 80 | EXCAVATION OF EARTH FOR CABLE / PIPE LAYING FOR ELECTRICAL WORK \nExcavation of earth for cable trenches/ laying of G.I. pipes for cable work in all types of soils including saturated soil up to a max. depth of 1.5 meters including shoring, strutting and bailing out of water (if necessary), backfilling and compacting in layers not exceeding 20 cm. thick to the finished ground level and disposal and dressing of excess earth within a lead of 50 meters all complete with labour and materials as per standards, drawings, specifications and directions of Engineer-in-charge. \n | Item80 / CEL0100700 | 5 | M3 |
|---|
| 10 | 90 | DEMOLITION OF PLAIN CEMENT CONCRETE Demolishing concrete and disposal of material within 50 meters lead: 1:3:6 or richer mix | Item90 / CEL0601201 | 2 | M3 |
|---|
| 11 | 100 | PCC 1:3:6 IN FOUNDATION\nProviding and laying Plain Cement Concrete 1:3:6 by volume (1 cement: 3 coarse sand: 6 coarse aggregate of specifications given below) for all depths below and upto plinth level in foundations, fillings, non-suspended floors, pavements and ramps etc. including tamping, ramming, vibrating, curing, shuttering etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed; complete with all labour, materials, tools and tackles, consumables, transportation etc.; all as per specifications and directions of the Engineer-in-charge\n\" 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).\" \n | Item100 / CEL1003301 | 2 | M3 |
|---|
| 12 | 110 | LAYING OF LT POWER/ CONTROL/ TELEPHONE/ INSTRUMENT/ CCTV/ COMPUTER AND OTHER CABLES IN TRENCHES\nHorizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed / XLPE LT power (voltage grade upto 1.1 KV)/ control/ telephone/ instrument/ CCTV/ computer and other cables of following sizes in pre-excavated cable trench or existing trench / RCC or\nHume or Stoneware or Metal pipe / masonry duct, fixing of number tags ( if required), testing plus transportation from stores to site, unpacking, straightening, dressing of cable and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge. NOTE: Cables will be supplied by the Owner free of cost. Overall diameter upto 35 MM\n | Item110 / CEL0100101 | 500 | M |
|---|
| 13 | 120 | LAYING OF LT POWER/ CONTROL/ TELEPHONE/ INSTRUMENT/ CCTV/ COMPUTER AND OTHER CABLES ON CABLE TRAYS/ STRUCTURES\nHorizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed / XLPE LT power (voltage grade upto 1.1 KV)/ control/ telephone/ instrument/ CCTV/ computer and other cables on cable racks/ wall and steel structures upto any height, fixing of saddles, aluminium strip, number tags ( if required), testing plus transportation from stores to site, unpacking, straightening, dressing of cable, fixing with clams/ cleats as required and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge.\nNOTE: Cables will be supplied by the Owner free of cost.\nOverall diameter upto 35 MM\n | Item120 / CEL0100201 | 750 | M |
|---|
| 14 | 130 | EXTRA FOR PROVIDING COPPER LUGS\nSupply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent\nCertified by EIC. of the following sizes. 6 sqmm\n | Item130 / CEL0108204 | 6 | EA |
|---|
| 15 | 140 | EXTRA FOR PROVIDING COPPER LUGS\nSupply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent\nCertified by EIC. of the following sizes. 10 sqmm\n | Item140 / CEL0108205 | 6 | EA |
|---|
| 16 | 150 | EXTRA FOR PROVIDING COPPER LUGS\nSupply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent\nCertified by EIC. of the following sizes. 25 sqmm\n | Item150 / CEL0108208 | 6 | EA |
|---|
| 17 | 160 | EXTRA FOR PROVIDING COPPER LUGS\nSupply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent\nCertified by EIC. of the following sizes. 35 sqmm\n | Item160 / CEL0108209 | 6 | EA |
|---|
| 18 | 170 | EXTRA FOR PROVIDING FLAMEPROOF DOUBLE COMPRESSION (BRASS) CABLE GLANDS\nSupply of CMRS / CCE approved\nflameproof double compression (brass) cable gland for following\noverall cable sizes as per directions of Engineer-in-Charge. 10.0 to 16.0 mm\n | Item170 / CEL0108401 | 12 | EA |
|---|
| 19 | 180 | EXTRA FOR PROVIDING FLAMEPROOF DOUBLE COMPRESSION (BRASS) CABLE GLANDS\nSupply of CMRS / CCE approved\nflameproof double compression (brass) cable gland for following\noverall cable sizes as per directions of Engineer-in-Charge. 23.5 to 26.0 mm\n | Item180 / CEL0108405 | 6 | EA |
|---|
| 20 | 190 | EXTRA FOR PROVIDING FLAMEPROOF DOUBLE COMPRESSION (BRASS) CABLE GLANDS\nSupply of CMRS / CCE approved\nflameproof double compression (brass) cable gland for following\noverall cable sizes as per directions of Engineer-in-Charge. 33.5 to 37.0 mm\n | Item190 / CEL0108408 | 6 | EA |
|---|
| 21 | 200 | Testing & commissioning of CP system | Item200 / | 1 | LS |
|---|
| 22 | 210 | Installation of new Cu/CuSO4 reference\ncell for replacement of the\nexisting faulty reference cell as per\ninstructions & directions of\nEngineer-in-Charge (all required\nmaterial & labour shall be in the scope\nof the contractor). | Item210 | 3 | EA |
|---|
| 23 | 220 | Installation of MMO anodes, 25mm dia x\n1500mm length with derated\ncurrent output of 1A/MMO anode\noperating at 8A/m2 anode current density\nin sand with design life of 50 years.\nWork shall be done as per instructions\n& directions of\nEngineer-in-Charge (all required\nmaterial & labour shall be in the scope\nof the contractor). | Item220 | 4 | EA |
|---|