Nit No . 04 Item No . 09 Renovation/Electrification Of Room No . 101 Being Used By Member ( A ) At Varunalaya Ph-Ii And Room No . 401 , 408 , 415 , D/Man Cabin At Varunalaya Ph-I And Other Allied Works . , Wiring Of Light Point /Fan Point/ Exhaust Fan Point /Call Bell Point With 1 . 5 Sq . Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/Recessed Medium Class Pvc Conduit , With Modular Switch , Modular Plate , Suitable Gi Box And Earthing The Point With 1 . 5 Sq . Mm . Frls Pvc Insulated Copper Conductor Single Core Cable Etc . As Required . ( Dsr No . 1 . 10 . 3 Group C ) , Supply And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess , Including Providing And Fixing 6 In 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch , Connections Etc . As Required . ( Dsr No . 1 . 32 ) , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess , Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/6 A Modular Switch , Connections Etc . As Required . ( ( Dsr No . 1 . 31 ) , Supply And Fixing Two Module Stepped Type Eletronic Fan Regulator On The Existing Modular Plate Switch Box Including Connecctions But Excluding Modular Plate Etc . Ass Required . ( Dsr No . 1 . 25 ) , Wiring For Circuit/Submain Wiring Along With Earth Wire With The Following Size Of Frls Pvc Insulated Copper Conductor , Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required . 2 X 1 . 5 Sq . Mm + 1 X 1 . 5 Sq . Mm Earth Wire . ( Dsr No . 1 . 14 . 1 ) , Wiring For Circuit/Submain Wiring Along With Earth Wire With The Following Size Of Frls Pvc Insulated Copper Conductor , Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required . 2X2 . 5 Sq . Mm +1X2 . 5 Sq . Mm Earth Wire . ( Dsr No . 1 . 14 . 2 ) , Wiring For Circuit/Submain Wiring Along With Earth Wire With The Following Size Of Frls Pvc Insulated Copper Conductor , Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required . 2X4 Sq . Mm +1X4 Sq . Mm Earth Wire . ( Dsr No . 1 . 14 . 3 ) , Wiring For Circuit/Submain Wiring Along With Earth Wire With The Following Size Of Frls Pvc Insulated Copper Conductor , Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required . 4X10 Sq . Mm +2X6 Sq . Mm Earth Wire . ( Dsr No . 1 . 14 . 10 ) , Supplying And Fixing Of 4 Way ( 4 + 12 ) , Double Door , Surface/ Recess Mounting , Vertical Type , 415 V , Tpn Mcb Distribution Board Of Sheet Steel , Dust Protected , Duly Powder Painted , Inclusive Of 200 A Tinned Copper Bus Bar , Common Neutral Link , Earth Bar , Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Dsr No . 2 . 5 . 1 ) , Supplying And Fixing 5 A To 32 A Rating , 240/415 V , 10 Ka , C Curve , Miniature Circuit Breaker Suitable For Inductive Load Of Single Pole In The Existing Mcb Db Complete With Connections , Testing And Commissioning Etc . As Required . ( Dsr No . 2 . 10 . 1 ) , Providing And Fixing 63 A Capacity Tp&N Disconnector Fuse Switch Unit Inside The Existing Panel Board With Isi Marked Hrc Fuses Including Drilling Holes In Cubicle Panel , Making Connections , Etc . As Required . ( Dsr No . 2 . 1 . 2 ) , Installation , Testing And Commissioning Of Ceiling Fan , Including Wiring The Down Rods Of Standard Length With 1 . 5 Sq . Mm Frls Pvc Insulated , Copper Conductor , Single Core Cable Etc . As Required . ( Dsr No . 1 . 44 ) , Installation , Testing And Commissioning Of Pre- Wired , Florescent Fitting/Compact Florescent Fitting Of All Types , Complete With All Accessories And Tube /Lamp Etc . Directly On Ceiling/Wall , Including Connections With 1 . 5 Sq . Mm Frls Pvc Insulated , Copper Conductor , Single Core Cable And Earthing Etc . As Required . ( Dsr No . 1 . 41 ) , Installation Of Exhaust Fan In The Existing Opening , Including Making Good The Damage , Connection , Testing , Commissioning Etc . As Required Upto 450Mm Sweep . ( Dsr No . 1 . 50 . 1 ) , Supply And Fixing Call Bell/ Buzzer Suitable For Single Phase 230V , Complete As Required . ( Dsr No . 1 . 38 ) , Complete Recess Direct/Indirect Luminaire With High Brightness Led And De Glaring Panel Cover For Efficient Down Light 4X1 Ft . Diffused Optics 36 To 42 Watt . ( Make:Philips/Crompton/Havells ) . ( Rate-Mrp ) , Supply Of Led Batten 36-40 Watt . Make: Crompton/Havells/Philips . ( Rate-Mrp ) , Supply Of Ceiling Fan 240 Volt 1200Mm Sweep Size ( Market Rate ) Make:- Orient/Havells ( Rate-Mrp ) , Supply Of Vantilation Fan 250 Mm . ( Make- Havells/ Crompton/ Orient ) . ( Rate-Mrp ) , Supply Of 1 . 5 Sq . Mm . Copper Cable , Single Core , Pvcflexible , Fr . ( Make:-Havells/Polycab/Anchor ) . ( Rate-Mrp ) , Supply Of 2 . 5 Sq . Mm . Copper Cable , Single Core , Pvcflexible , Fr . ( Make:-Havells/Polycab/Anchor ) . ( Rate-Mrp ) , Supply Of 4 Sq . Mm . Copper Cable , Single Core , Pvcflexible , Fr . ( Make:-Havells/Polycab/Anchor ) . ( Rate-Mrp )