Supply, Installation, Testing And Commissioning Of Indoor And Outdoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System And Allied Works In Connection With Replacement Of Existing Rri System By Ssi At Bsl , Gurgaon-Haryana

Rail India Technical And Econimics Services Ltd-RITES has published Supply, Installation, Testing And Commissioning Of Indoor And Outdoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System And Allied Works In Connection With Replacement Of Existing Rri System By Ssi At Bsl . Submission Date for this Tender is 02-08-2021. Railway Signaling Systems Tenders in Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

28442478
Supply, Installation, Testing And Commissioning Of Indoor And Outdoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System And Allied Works In Connection With Replacement Of Existing Rri System By Ssi At Bsl
Open Tender
Indian
Haryana
Gurgaon
02-08-2021

Tender Details

Supply, Installation, Testing And Commissioning Of Indoor And Outdoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System And Allied Works In Connection With Replacement Of Existing Rri System By Ssi At Bsl

Key Value

Document Fees
INR 18000 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:Supply, Installation, Testing & Commissioning of Indoor & Outdoor gears of Signalling & Telecommunication system including Electronic Interlocking system and allied works in connection with Replacement of existing RRI system by SSI system at Steel Works Station BSL
Sl. No. Item Description
1SCHEDULE -1(S&T work)
2Supply of Electronic Interlocking (Hot Standby) with dual VDU of 55" with Signalling functions as per RDSO Specification No. RDSO/SPN/192/2019 Ver.2.0 and to suit the signalling plan and to suit the signalling plan of stations. Scope of supply against this item includes all the indoor equipments necessary for successful functioning of centralised EI system, mainly consisting of but not limited to followings conforming to attached Technical specifications . 1. Microprocessor equipment. 2.I/O cards with card cage and motherboard. 3. Power supply cards. 4. All types of connectors and couplers as required. 5. Industrial grade Dual VDU of 55" . 6.Industrial grade PC & monitor of 42" 7.maintenance VDU of 42" console with Laser printer at panel building. 8. All types of relays required for interfacing. 9. ECRs suitable for LED signal lamps. 10. DC-DC convertors (input voltage 110 V DC and output voltage as required) 11. All types of indoor wires as required. 12. All types of indoor terminals and fuses as required except terminals for main CTR.
313. Racks for mounting EI equipments and interfacing relays. 14. Termination rack for indoor cables. 15. Fixtures, mounting arrangements, Ladders for wire run andother accessories as required. 16. Softwares used for designing, configuration, maintenance, data logging and fault diagnosis of EI system. 17. Protective devices like lightning protectors for DC and AC supplies, isolator/convertor for serial communication etc. 18. Documents and manuals as per RDSO/SPN/192/2019 Ver.2.0 in three sets. 19. Ring Earthing and EMI shielding of EI room. 20. Any other item contractor feels neccessary as per their sysyem. 21.Completion plan of stations. 22. Class "A"type surge protection device protection at each SSI room/goomty, mounting arrangements and accessories necessary to make the EI system functional. 23. Work place for EI is also provided by the contactor
4Note: 1. Supply of Optic Fibre Cable, 60Cx1mm indoor cable, IPS, 24 V point operatingrelays(QBCA1), KLCR, Main Cable Termination Rack & terminals for Outdoor cables and relay rack for mounting pointrelays are not included in this item. 2. All the materials, submitted by the bidder as above and are neccessary for successful commissioning of system, shall be supplied by the contractor without anyextra cost. Variation in Bits and variation in number of routes upto (+) 10% shall have no cost bearing. 3. For further variation (above 10%) of routes, cost will be recovered on prorata basis for % of routes increased.
5(i) SWSYARD
6Spares of O&M
7Supply of all spares to the extent of 10% of that supplied against EI item subject to minimum of one, for the cards/modules,connectors /couplers, fuses & relays.used in the EI system. Item-wise details of spares to be supplied with unit rates should be listed out by the tenderer along with offer.
8(i) SWS YARD
9Supply of Laptop based work station for data inputs & configuration, simulation and functional testing, diagnostics, trouble shooting and commissioning of EI system, complete with necessary softwares preloaded. as per specifications mentioned in TS.
10Tool kits and Measuring Instruments for Technicians /Junior Engineers for testing & maintenance and repair at site as specified by Original Equipment Manufacturer of EI.* Above items includes suitable cabinet for storing tools to ensure longer life.
11Supply of Hard & soft copy (6 copies as built ) offollowing indoor drawings for RITES/ Rly approval including one copy on good quality 7.5 micron polyster film: thisincludes expenses for checking/rechechecking/ obtaing appovals from Railways /RITES .Thealso includes supply of two sets of drawings for checking, approval and corrections thereon as suggested by RITES/Rly) & threater supply of 2 copies for testingcopy & 2 copies ascostruction copy.RITES shall make available Schematic SIP.Contractor to Prepare and submit SIP"s and other Misc Drgs as per concerened Rly practice and get its approval from railways,if requiered- (i) Signalling Interlocking Plan (as per Rly practice) (ii) Selection table, (iii) Vital & non-vital I/O Bit Chart, (iv) EI configuration diagram, Equipment layout plan, Relay disposition chart. (v) Front plate diagram of control/indication panel. (vi) Application logic (vii) Interface circuit with contact analysis. (viii) Equivalent circuit of application logic. (ix) Prepration & supplyofSWRD (station Working Rule Diagram). (x) Prepration & supplyof station working Rule.
12Relay Rack assembly complete with fixtures for mounting point group relays/"Q" style relays in Relay or EI Hut with all accessories like scaffolding, ladder, runway for indoor cables/wires alongwith mounting arrangement as per drg. No. NR/S&T/project/14/2015
13Main cable termination rack complete assembly with hylam sheet , screws, nuts & bolts, scaffoldingladders for cable wires alongwith mounting arrangements etc. as per Drg No..NR/S&T/project/13/2015..Fuse block shall be suitable for round head type voltage fuses rating:2A/4A/16A
14Fuse block made of PBT as per IRS:S-75/2006 (Rev-2) & RDSO Drg.No.SA-23748 Alt.4 and Spec.No.IRS S 78/92 (Amdt-2) or latest amendment. Fuse block shall be suitable for round head type voltage fuses rating:2A/4A/16A.
15Non deteriorating type fuses as per IRS-S-78/92 with latest amendment. Rating 2Amps-65%, 4Amps-25%, 16Amps-10%.Fuse shall be suitable for round head type voltage fuses rating:2A/4A/16A
16ARA terminal (1 way)made of PBT as per drg.no.23746 & specn. No.IRS-S-75/2006 (Rev.2 or latest) with disconnection link as per Drg.SA-23746 Or 23745(Alt-5).
17ARA terminal (6way)made of PBT as per drg.no.23746 & specn. No.IRS-S-75/2006 (Rev.2 or latest) with disconnection link as per Drg.SA-23746 Or 23745(Alt-5).
18Supply of 2 conductor disconnect terminal block for test and measurement 0.8 sq.mm-2.5 sq.mm centre marking with test slot for test plug 2mm/0.079IN and 2.3mm/0.091IN carreir rail DIN 35 front entry cage clamp connection Grey wago or similar as RDSO/SPN/189/2004 Ver.2.0 or latest.
19Supply of End and Intermediate Plate 2.5mm/0.098 in Thick Wago or similar as per RDSO/SPN/189/2004 Ver.2.0 or latest.
20Supply of Steel carrier Rail 35x7.5mm/0.039in thick unslotted, yellow with Chrome Wago or similar as per RDSO/SPN/189/ 2004 Ver.2.0 or latest.
21Supply of screw less end stop 10mm/0.394 in wide carrier rail DIN 35 Grey Wago or similar as per RDSO/SPN/189/2004 Ver.2.0 or latest.
22SMPS based Integrated Power Supply as per RDSO Specification No. RDSO/SPN/165/2012, (Ver 3.0) with latest ammendment alongwith LMLA Battery Bank of 200AH & Battery rack(Configuration based on RDSO dwg. no. SDO/IPS/PI-6L/RE/004and site specific load requirement, shall be put up to RITES with load calulation sheet shall be approved by employer/consultant before supply)
23DG set 15 KVA, 230 V ACsingle phase with only Mahindra or Kirloskeror Cummins or crompton or similar quality alternatormake , two wall mounting control panels (one main and one subsidisry for remote operation) to start generatoe by push button battery operated- 15KVA to IRS-S-69/86 along with sound proof enclosure for DG set as per latest guidelines of Central pollution control board of india. This includes a) Supply of batteries 12v, 200AH 1 No. with each DG set for self starting and Iron clad siemens or sony single phase (2 way ON-OFF-ON) changeover switch 63 Apms). Suitable Battery cahrger for charging this battery c) 60 liter diesel tank
24Supply of Automatic change-over unit for change-over between three power supply sources of 63 A/230 volts, single phase with provision of manual bypass arrangement. Drawing shall be got approved by Engineer Incharge.
25Supply & installation of maintenance free single earthing for IPS Equipment. All the materials required shall be supplied by the contractor including cadmium bronze wire rope for connection between earth electrode and equipment box).
26Supply and installation of Earth leakage Detector for monitoring different AC and DC supplies including all accessories as per Spn RDSO/SPN/256/2002 or latest and stipulations of tender doccuments (ELD having 12 channel type).
27Supply of Crank handle Box 1000 x 250 x 150mm made of 12 mm thick Teakwood with a glass front and padlocking and sealing arrangement as per standard practice.Pad locks to be supplied by contractor, all materials i.e. Teakwood, handle, hinges, Glass sheet of 3mm thick to be supplied by the contractor.Box to be polished and description to be painted as per instructions of Engineer in charge.
28Wooden block counter of size 700 mm x 700 mm W x 900 mm H made of teakwood frame & 10 mm /20 mm thick water proof ply with formica finish on top and all four sides having two compartment inside & two doors on opposite sides.
29Office Chair of continuous arms having cushened seats and rest T.W. Arm rest size 36" x 21" x 22 approx steel tubular frame gauge of the pipes 25mm dia x 18 gauge with olive green colours, Green stove enamelled "Indian Make". Godrej/Jalaram Make.
30Office Table of size of table top 1220 mm x 610mm height 750mm with laminated top with 3 drawers on the left hand side and one locker on the right hand side olive brown with Duplicate keys.Olive green colour Godrej Make.
31Plain storage almirah with 4 adjustable shelves size 1980mm height, 915mm width, 485mm depth, GodrejMake.
32Airy Revolving and tilting working cushioned adjustable height chair with arm rests, polished black.The chair has plastic caned seat and back on 25 mmround tubular frame.The base is of pressedsheet metal. Godrej/ Allwyn/ Chandan/ Khira make.Width 700 mm,Depth 700 mm, Height 870 mm, Adjustable seat height 410 mm to 520 mm, ColourGrey.
334 door book case of size 1675x840x308mm Godrej make
34Supply of desk type magneto telephone suit IRS TC:36-97 (Amndt.1) or latest with latest amendments.
35Relay "Q" series neutral line, AC Immune, plug-in type, Style `QNA1".DC Neutral line, 24V, 8F/8B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDGH.
36Relay "Q" series neutral line, AC Immune, plug-in type, Style `QNA1".DC Neutral line, 24V, 12F/4B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDFH.
37Supply of Key Lock Relay, type TMA 24V DC with 2F/2B contacts cofiguration with different wards combination as per latest RDSO specification. Details of ward combination will be provided during execution of work.
38Supply, Installation, testing and commissioning of LED based operating cumindication panel of size 450mm x 300mm to be installed in the adjacent cabins/control rooms to SWS station as per requirement for slotting purpose. This includes supply of teakwood, sunmica, SM"s Key,operating heavy duty push buttons, indication lamps, terminal strip(s) for termination of cable(s) and any other material required for its fabrication, intallation, testing andcommissioning as per instruction of Site Engineer.
39PVC Insulated Armoured un-screened, under- ground Railway Signaling copper conductor cable confirming to RDSO Specification no. IRSS- 63/2014 with amendment -4 or latest
40(i) 6 core x 1.5 sq.mm.
41(ii) 12 core x 1.5 sq.mm.
42(iii) 24 Corex1.5 Sq mm
43PVC insulated armoured, Unscreened, Underground Power cable, 2x25 sq. mm. Stranded Aluminium conductor confirming to RDSO specification IRS:S-63/2007 with latest amendment and IS 1554 (part-1)
44Underground railway jelly filled 6 Quad cable for signalling & telecom installations confirming to IRS: TC-30/2005 (Ver. 1) Amndt 1 to 5 orlatest amendment having 0.9mm dia.
45Armoured Optical Fibre cable 24 Fibers as per RDSO specification No. IRS:TC:55-2006 rev. 1 with Amdt. 1.1
46Cable unarmoured PVC insulated, unseathed with plain annealed high conductivity 650V grade copper conductor as per colour coding scheme of Raliways in 100 meter coils, confirming to RDSO Specification No: IRS-S-76/89 with latest amendment-
47(i) 16 x 0.2 mm.(Grey)
48(ii) 3 x 0.75 mm. (Red, Green & Black)
49(iii) 1x6 sq mm. (multistrand flexible wire)
50(iv) 1x10 sq mm.(multistrand flexible wire)
51Thermo Shrink joining kit suitable for 6 QUAD jelly filled cable-straight throughas RDSO specn. No.IRS: TC 77/2012 (Rev.3.0) with (Amdt.-1 to 3) or latest.
52Supply of HDPE telecom duct with outer diameter of 40 and inner diameter of 33 mm permanently lubricated as per Specification no. RDSO/SPN/TC/45/2013, Rev.-2.0 Amdt.-1.0 & 2.0 orTEC GR No.G/CDS 08/02 Nov.2004 with latest amendment as available or latest. HDPE pipe shall be suppliedFor each Km. of HDPE duct following items are to be supplied alongwith 4 mm dia polypropylenerope of approved quality inside whether required. For each Km. of HDPE duct following items are to be supplied a) End plugs-2 No.b) Cable sealing plugs - 2 Nos.C) Plastic couplers slip fit/push fit type-2 No.d) End plugs to be provided along with drum - 2 No.
53Supply of Half split double wall corrugated (DWC) pipe of HDPE in2/3 meter length produced out of full round DWC pipes as perIS:14930 part-II marked on it. This item includes supply of necessary fixing & coupling arrengement.
54(i) Size : 120 mm outer dia. and 103 mm inner dia.
55(ii) Size : 200 mm outer dia. and 175 mm inner dia.
56Non-Split HDPE DWC pipe Confirming to IS:14930 part-II, with threaded coupler, of following sizes:
57(i) Size 120mm outer dia and 103 mm inner dia
58(ii) Size 200mm outer dia and 175 mm inner dia
59Supply and placing of second class bricks/Fly Ash brick size 225mm x 112mm x 75mm after laying of cable & refilling the trench by loose soil of 100mm to over cable.
60Galvanised Iron pipe 100 mm dia `B" class,(6 Mtr. Length) as per specn.No.IS-1239, part 1 / 1990. along with threaded coupler (Perforated with 6 mm holes)
61Fabrication, supply and fixing of cable marker of 1:3:6 concrete as per No.RITES/SIG/GEN/48-08. The marker shall be fixed at various places of cable route as per instructions of Engr. at site
62Colour light signal (2 aspect) complete set as per drg.No.SA - 23003 A/M (adv.) & Specn. IRS-S-26/64 consisting of the following items :
63Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81.
64Signal base Cast Iron 140 mm dia. to drg. No. S-2011/M.
65CLS ladder complete with platform and base 4.5 mtrs.long to drg.No.SA-23153 (Adv.) Alt 1.
66Colour Light Signal Unit 2 Aspect complete with outsignal transformers, lenses & lamps, suitable for 140 mm dia.post as per drg.No.SA - 23003 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.
6704 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78
68Colour light signal (3 aspect)complete set as per drg.No.SA23002 A/M (adv.) & Specn. IRS-S-26/64 consisting of the following items :
69Signal post 140 mm dia 4.5mtrs. long to IRS-S-6-81.
70Signal base Cast Iron 140 mm dia. to drg. No.S-2011/M.
71CLS ladder complete with platform and base 4.5 mtrs.long to drg.No.SA-23153 (Adv.) Alt 1.
72Colour Light Signal Unit 3 Aspect complete with outsignal transformers,lenses & lamps, suitable for 140 mm dia.post as per drg.No.SA - 23002 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.
7304 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 with latest amendment.
74Universal AC/DC numeric Route Indicatorfor 1-25 Routes complete housing with LED lamps and one left and one right arm
75OFF set bracket for Colour light signal 140mm outside dia.post with "U" bolt and nuts as per drg No: SA-23080 (adv.) alt. 1.
76Independent shunt signal complete having following items.
77Shunt signal post 90 mm dia 1m long to IRS-S-6/81.
78Shunt signal surface base 90 mm dia drg.No. S-2011.
79Position light shunt signal unit without lamp holder unit,lenses & lamps to RDSO drg.No.SA-23840(adv.) ALT-2.
8004 nos. anchor bolts for shunt signal (305mm. X 50mm. X 20mm.) to drg.No.SA-110 A/M.
81Shunt signal dependent type drg No. SA-23840 (adv.) Alt.-1 and S-23845 (adv.) with offset bracket 3½"" dia.to suit 140mm. Outside dia post complete without lenses, lamps & lamp holders.
82Calling on signal unitposition light type complete with mounting socket to Drg No. SA-24351 (Adv) or latest, specn. No. IRS-S:10/78, IRS-S:26/64.
83LED signal lighting unit for calling on signal conforming to Indian Railway chromaticallity standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing)
84Supply of LED Signal Lighting Unit for Main Signals as per RDSO specification No. RDSO/SPN/199/2010 (Rev 1.1) ) or latest
85(i) For Redaspect
86(ii) For Yellow aspect
87LED signal lighting unit for shunt signal conforming to Indian Railway chromatically standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 or latest (This item includes fuses and other accessories required for fixing)
88Supply and fixing of Crank handle Box 1000 x 250 x 150mm made of 12 mm thick Teakwood with a glass front and padlocking and sealing arrangement as per standard practice.Pad locks to be supplied by contractor, all materials i.e. Teakwood, handle, hinges, Glass sheet of 3mm thick to be supplied by the contractor.Box to be polished and description to be painted as per instructions of Engineer in charge.
89Relay AC immune, plug in type style QBCA1, DC based point contactor, 24V DC, 2F (HD) 4B contacts, front contacts heavy duty and back contacts metal to carbon complete with plug board, retaning clip and connectors confirming to BRS943, IRS S-34 & IRS S-23 interlocking code BCESK.
90Relay, AC Immune, plug-in type, Style "QNA1K" 24 V/1000 Ohm
91Single Section Digital Axle Counter System complete with dual detection as per RDSO specification No. RDSO/SPN/177/2012 (Ver 3.0) or latest consisting of: (i) Track Side High Availability Single Section Digital Axle CounterSystem DACF-720P=2 Nos. (ii) High Frequency TX coil & RX Coil (AD-711) (Each set consisting of web mounting type 2Nos. TX nd 2 Nos. RX Coil)= 2 Sets. (iii) Vital Relay Box Model VR-722=02 Nos duly wired with the following relays Vital Relay QN1 K.24V 6F-6B=02Nos. b) Reset Relay QN1K.24V 6F-6B=01Nos. c) PR Relay QNN1 24V 6F-2B (Dual)=1No. (iv) Clamp withDefletorPlstes and hardware= 4 Nos.(v) Reset Box model No. 259A=02Nos. (vi) Surge Voltage Protection Device Mounted on DIN Rail= 02 Nos.
92Multi section digital Axle Counter (MSDAC) system shall comprise of Axle detectors , DAC field unit, Central evaluator, Reset unit, relay unit & event logger, and maintenance free earth as per OEM"s requirement.confirming to RDSO specification no-RDSO/SPN/176/2013, Ver.3 or latest/
93Supply of following as spares, Quantity of each item should be 10% of that supplied against item no. 10 above, rounded off up to zero decimal subject to minimum of one,1. All types of cards/modules and card cage including power supply & CPU cards. 2. All type of Relays3. All type of connectors/couplers, fuses and terminals. 4. All type of DC-DC convertors 5. Detection point (double rail contact) and line side electronic box with housing. 6. reset box and PDCU. Note: 1. All the materials suuplied as spares will be exactly similar to that supplied against item no above.
94Tool kit for Multi section/Single section Digital axle counter as per specified by Original Equipment Manufacturer.
95Electrical point machine, IRS heavy duty non-trailable rotary locking type 143mm throw to operate on 110V DC complete with lock & detector slides and cable termination box as per IRS:S-24/2002 (Amd 1) & IRS-S-37/82 (Amd 3 or latest), Drg. No. S-10910 for motor Assembly Drg. No. S-10800. (One No. tool kit will be supplied for installaton for a group of 08 Nos of point machine), D Brackets, L bracket including ground connection.
96lock facing point (HP type) - Single, complete with plunger, split stretcher bars and "E" type lock and keys to Drg. No. SA-3148/M complete in all respect
97lock facing point (HP type) - double, complete with plunger, split stretcher bars and "E" type locks and keys to Drg. No. SA-3149/M complete in all respect
98Single apparatus case Full steel RE with "E" type locks and key ward No 42 & handle as per Drg No. RITES/SIG/GEN/043-08
99Apparatus case steel RE half with "E" type locks and key ward No 42 & handle as per Drg No. RE/S&T/ALD/SK/220/82 & 221/82 with Alt.B.
100Key Lock "E" type with key Drg.No.SA-3376/M. Alt-2. Spec.No.IRS-S-30/64 different wards.
101Design, prepearation & supply ofSix (06) hard copies of each documents along with soft copy for the mention below alongwith original tracing on a standard 7.5microne polyester film in AUTO CAD FORMAT. (The item includes supply of two sets of drawings for approval and corrections thereon as suggested by RITES)
102i) Cable route plan
103ii) Location box details with location wiring diagram
104iii) Cable termination details
105iv)Cable corage plan
106v) C.T. Rack details
107vi) Track bonding plan
108vii) Cable jointing details
109viii) Signal lighting circuit
110ix) Circuit diagram for LC Gate No.
111x) Gate Working Rule with Gate Signal Diagram
112Supply and fixing of Stop Board/SLB/BSLB/Good warning Board/Calling-on Board as per RDSO Drg No SA-2373 with latest amendment, Casting, concreting and curing of foundation & erection SLB/BSLB/SB asas per SE RailwayDrawings.
113Supply of hand cuff (universal) locks with key (one key for every 4 locks).
114Supply and Installation of Demineralizer plant of aquaguard make or similar capacity 65 Litres per hour approx. This includes all thepipe connections from water source to unit and also to collection unit.
115Supply & installation of Annunciator (Multiway telephone exchange) 15 lines as per RDSO Drg no. TCA-3352 (Adv.) or latest.
116Supply, writing and fixing of description boards made of ply 6mm thick with white sunmica glued over its surface and 1"x1" wooden batton fitted all around onthe rear as per instruction of Engineer at site. All the materials to be supplied by contractor.
117Supply of Hydrometer of reputed make for measuring specific gravity of the battery graded acid with mounting stand in battery room /location boxes.
118Supply of electronic Cable Route Locator/Tracer equipmentofC-scope/Stanley make or similar. (i) Cable avoidance tool DXL2 digital under ground cable & pipe locating receiver and cable avoidance tool. (ii) SGV2 signal generator. (iii) Signal lamp accessory ST-SC. (iv) Carry bag ST-CB and as per technical specification.
119Supply of cable fault locator for underground cable as per model no. Telscout TS-90 (Test signal output1/2 Sine, Pulse width 5nsec to 2500nsec, Max Range:1500m, Filter cut-off Frequency:150kHz(High Pass Filter), Gain:0 to 63dB), Stanley or similar branded make as per specification.
120Supply of Digital insulation Tester (Megger) 100 V,Motwani, Philips or equal to make. Inspection.
121Various types of markers as
122( i) P markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter "P" shall be written in black.
123(ii) C markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used.Letter "C" shall be written in black.
124(iii) Signal number plate as per drawing no. RITES/SIG/GEN46-08 3mm. thick white laminated MS sheet shall be used.Letter shall be written in black on yellow background.
125Supply of maintainer"s tool kit consisting of items as per list below :-
126Insulated Screw Driver 12" (Gedore or Taparia make)-2 No.
127Plier electric 8" - 2 Nos
128Plier cutting 8" - 2 Nos
129Stripper - 1 No.
130Nose Plier - 1 No.
131Spanner Set-1 No
132Spanner double ended -1 No
133Hammer Ball piece (medium) - 1 No
134Soldering Iron 125 watt-1 No
135Soldering Iron 65 watt - 1 No
136Multimeter digital - 1 No.
137Tool Boxof 18" size similar to VIP or Alfa make
138Supply of true RMS Digital Multimeter (Fluke Make Model -187 or similar)
139Electric track drilling machine (110/230V AC operated) for drilling hole up to 15mm. Dia on rail web including jigs for horizontal drilling.
140Digital Earth Tester 4-terminal Range 0-10/100 ohm with Ni-Cd rechargeable battery with the accessories kit and other required accesseories. Tec. Spen. No. GR/TIE-10/01 April 2005 or latest.
141Supply, Installation, testing and commissioning of Hi wall split AC of 1.5TR capacity suitable for single phase 50 Hz AC 230V comprising of following items complete in all respect for achieving successful operation of the unit:
142(a) Outdoor Conditioning Unit
143(b) Indoor Evaporative Unit
144(c) Interconnecting refrigerant piping with insulation, drain pipe, charge of refrigerant and oil etc. The unit should includerefrigerant piping, power cabling and drain pipe up to 8 running meter.
145(d) Automatic voltage controller/Voltage Stablizer of appropriate rating complete as required.
146(e) Iron stand of appropriate size for mounding outdoor unit with foundation/grouting as required.
147(f) All required safety and operational control
148VHF transreceiver set simplex, 25 wattMotorola model no. GM 338 or similar with suitable antenna attached to 12 feet support pipe and 30M RF cable. This shall also include the Power supply for 25W radio (12V/15Amp) with Sealed maint. Free battery (65AH) and one BNC to VHF adapter. This item shall comply to technical specification para.-16.0.
149VHFmobile transreceiver simplex, 5 wattMotorola model no. GP 328 or similar with rechargeable battery. This will include battery charger, one rechargeable spare battery and two spot frequencies for 5W and 25W radios.(supplier shall also do all the liasoning for obtaining spot frequencies from WPC). This item shall comply to technical specification para.-16.0.
150Supply and installation of single line press to talk intercom set with power supply for communication between panel room and relay room.
151(Execution of S&T)
152Installation, wiring, programming, Bell test,Site acceptance test (SAT), commissioning, Screening arrangementnt with Copper strips ,lightening- protection arrangement,Earthing wiring etcas per Railways practice and All Pre-commissioning tests of EI and other equipments supplied against each station, as per latesttechnical specifications of RDSO and OEM . This also includes preparation of design documents and supply of materials for installation, wiring, grouting, cutting of floors, walls etc. refilling of same, replastering, required CC/mesonary works, termination of cables with lugs/connectors, painting/lettering on relay rack/termination rack are to be done by the contractor.
153SWS
154Training of Technician/Jr. Engineers in installation, Testing, commissioning & trouble shooting of Electronic interlocking supplied against item no. 1 of this schedule including provision of hard copies of course modules for each trainee.
155Training of Sr. Engineers/Managers in installation, Testing, commissioning, trouble shooting and Repairs supplied against item no. - 1 of this schedule including provision of hard copies of course modules for each trainee.
156Testing and commissioning of completesignalling system integrationwith outdoor gears ,slotting,etc at the staion as a whole. All artisan staff and labours required for testing and with MACLS work shall be provided by contractorfor for indoor and outdoor work. Testing equipment such as simulation panel, signal and point operation simulation arrangement, multimeter,etc. shall be provided by contractor at his own cost. testing shall be carried out by contractor in presence of engineer-in-charge up to his satisfaction and neccesary alterations shall be done. Contractor shall depute sufficient staff to carryout outdoor work during commissioning for completion of work within stipulated time.It also includes provision of temporaty tents/Huts,arranging lights,Chairs & tables, provision of temorary telphones,snacks/drinking water for NI staff round the clock at siteetc as reqired duing the NI period in Railways.
157Termination of all cores of all types of Indoor/outdoor cables (Excluding termination in location boxes and terminations on items coming under item No.1 of Schedule A (Supply )after its laying, onboth ends and providing number ferrule on each core. This also includes fixing of ARA terminals/disconnecting type terminal block/ 8 way strip, meggering and preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also includes dressing and lacing of cables on both ends. Proforma for testing and material for lacing to be supplied by the contractor.
158Erection of cable termination rack.Clamping of cables, Numbering of cables with engraved aluminium strips, Supply of nuts & bolts, MS clamps & cement for massonary works.This will also include paintng ofCable/core particulars for each trminationwith contractors own paint.The place for erection of Termination Rack shall placed as decided by Site Engineer
159Installation of relay rack assembly complete alongwith wall supports, sccaffolding, ladders/runway for cables, relay base plates etc. This includes Fixing of Relays with retaining clips, Fixing of disconnecting type terminals/ARA Terminals, PBT Fuse bases( supplied under Schedle A,) , termination of cable cores/wires, Supply of nuts & bolts, MS clamps & cement for massonary works.:This will also include Painting of Relay description on the front side and back side of the Relays as per instruction of site engineer.
160Wiring of relay base plate to other base plate, to tag blockas per approved diagram & soldering after testing.This includes fixing of relay plug boards, terminal, blocks, terminals fuse board, fuses bus bar etc. Note: This item is for wiring of relays in relay room, which are not covered as part of EI system.
161Installation, wiring, testing and commissioningof multi channel earth leakage detector including supply of mounting arrangement.
162Necessary arrangement for manufacture, transportation & installation of station masters console for fixing telephones & other equipments as per instruction of Engineer incharge. This includes : All materials like 25mm thick hylum sheet etc. required for the above including sundry items like bolts & nuts, screws, MS angle / flat shall be supplied by the contractor.
163Installation, wiring, testing and commissioning of Integrated Power Supply (IPS) system, at station/cabin as per technical specification and instructions given in Installation manual of OEM.Approvalfor installation drawingsshall be obtained from project consultant before installation. This includes supply of allmaterials required for installation and initial charging of low maintenance Lead-Acid batteries (3 cycles).
164Installation of DG set, testing and commissioning. This includes casting of vibration free foundation, installation of ASM panel, outlet for exhaust panel, laying of power cable from DG room to ASM room for remote operation of DG set and wiring of DG set of ASM panel, laying of cables/wires should be carried out in HD PVC channel/ conduit pipe. This includes cost of all mateials required for installation except DG set andperASM panel. Wires/cables as extant practice on Railways and instruction of Engineer at site.
165Installation,wiring,testing & commissioning of LT power panel with auto change-over at Central Cabin. This includes fixing of power panel.termination of LT cables & fixing of Auto-change-over management and its wiring and supply of MS angle,nuts & bolts etc.
166Excavation of Trench, Depth 1.0 Mtr. & width 0.3 Mtr., in all soils including soft/hard rocky area and clearing of roots of trees, bushes, rocks etc., ballast and reconditioning etc., (including bailing out water and disposal of extra soil) including back filling with excavated earth and ramming of trenches after cable laying for the following depth and width as given below. The contractor has to conduct detailed site survey of the cable route.Prepare a plan to get approval of the owner"s authorised representative, putting white lime powder marking before excavation of earth under supervision of owner"s authorised representative.Whereverseveral cables of different categories have to be laid in the same path, all cables shall be separated with brick through out the length, instead of seperate trench in the concerned area.
167Excavation of cable trench of 1.0 m. depth & 300 mm. wide across the track width at level / track/Road crossing platform &refilling after laying DWC/RCC pipe (laying of DWC/RCC pipe shall be paid under separate item of schedule) as per cable route chart & technical specification. as per This include repairing and plastering of platform/pucca road after cable laying.
168NOTE:- Power cable, signalling cable, Quad cable, PIJF, OFC etc. as mentioned above, where required, shall be laid in the same trench as signalling cable but in a separate pipe.
169Excavation and refilling of trenches in rocky soil to the level of ground with rammed earth so as not form a drain 0.3 M wide & 0.5 M deep. This includes (i) clearance of routes of trees & bushes and (ii) 50 mm thick concreting work throughout in 1:3:6 ratio. All concreting material shall be supplied by the contractor. Lesser depth of trench shall be paid proportionately.
170Filling of cable duct by sieved silver/fine sand after laying of cable in relay rooms. Supply of sand shall be made by the contractor.
171Fixing/ laying of DWC/RCC pipes for laying of cables (including under-neath the track, Road crossing or other platform cutting etc.) as per drg.No. RITES/SIG/GEN/028-98 & RITES/SIG/GEN/031-98
172Fixingof Galvanised iron pipe 100 mm dia. on panel buildings. This includes supply of clamps, support, nuts, bolts etc. & concreting of ends with brick masonary work including supply of cement, sand an aggregate.
173Laying of 40/33 mm dia HDPE pipe as per approved cable route plan in the excavation trench at 1 mtr depth.
174Transportation of cables in roll with or without wooden drums to work site and meggering before loading and after laying, and recording the values in cable insulation register along with representative.
175Laying of signalling/Telecom cable in the trench/GI/RCC/DWC pipe as per cable route plan (Note: before issuing of cable to the contractor, the cable will be meggered jointly by the contractor and RITES Engineer at site and meggering certificate will be submitted in the office of the Engineer In Charge. Where cable is laid in HDPE pipes, no protective bricks are required. The same procedure will be adopted after the cable in laid at site without which no payment will be made to the contractor. If the insulation resistance after laying of cable is less than the reading previous meggering report. The contractor will have to repair or replace the defective cable at his own cost for which no charges will be paid .
176Laying of power cable in the trench or DWC pipe as per tech. specification.
177Layingof 6 quad cable in the trench/DWC pipe as per tech. specification..
178Making Heat Shrinkable joint for U/G signalling cable Joint supplied as per of supply schedule
179Making straight through joint with heat shrinkable jointing kit for 6 quad cable.
180Transportation, supply of U-Clamps and anchoring of cable at every 30 mtrs.
181Installation, wiring, testing and commissioning of 110 V,DC point machine as per specifications andapproved wiring diagrams.Thisincludes:
182Fixing of point machines on MS plate fixed onsleepers complete with fixing of anti theft covers, cable terminal box, ground connection.
183Fixing of insulation for gauge tie plate and crossingplate for 52 / 60 Kg. points and crossings.
184Fixing of insulation for switch extention pieces (D brackets) andleading & following stretcher bars.
185Wiring from the cable termination box to the point machine as per specifications.
186All smithy works.
187Supply of MS plates, flat, angle, bolts, nuts, pins as required.This item also includess supply & fixing of GI pipe bend for the protection of cablefrom cable termination box to piont machine.
188Testing the point machines from point of operationincluding testing with 5 mm test piece.
189P-way works required before provision of point machines such as .squaring of switches, packing and leveling/alignment of track,easing or rails on either side of points to be interlocked,making proper spacing of sleepers etc
190Fixing and testing of facing point lock, this includes fixing of switch extension pieces, HP lock on gauge tie plate, cutting notches on locks, connecting with levers through rodding for points. Supply of HP lock cover made from 3mm. M.S. sheet, testing and commissioning.
191Intallation, programming, Testing along Commissioningof Central Evaluators of MSDAC (includes & OEM certification),wiring from CT rack to the Central Evaluator, Installation and wiring the reset box and wiring the power supply to the Central Evaluator including the supply of shielded cable of required conductor size as applicable with other accessories, with their own material.Note: 1. Variation in detection points and/or track sections upto (+) 10% shall have no cost bearing.2. Installation of detection points and line side electronics box is not included in this item.
192Installation, Testing & Commissioning of track device (double rail contact) including digging of trench, track crossing, laying of double walled antirodent corrugated pipe from track device to track side housing and making its terminations. Termination of 4Quad cable in track side electronic box. Fixing of deflector plates. (Double walled antirodent corrugated pipe made up of high density polyethylene of required diameter and all other accessories as per site requirement to be supplied by the firm & installation of EJB/ Track side electronic box inside the track side housing, including supply of wires and other accessories.
193P-way work required for provision of Axle counter track detection devices to be fixed on rails including work involving re-spacing of sleepers, packing of sleepers etc
194Excavation of pit, casting & plastering of concrete foundation for C.L.Signal & ladder. as per drg.SIG/GEN/001-98.This includes :Supply of cement, sand, stone chip & mixingin the ratio 1:3:6.
195Erection of2 aspect colour light signals.This includes :
196Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing ofhoods & LED lamp units with current regulating transformer on 2aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity.
197Wiring & testing of signal unit as per the specifications and directives of engineer at site.
198Erection of3/4 aspect colour light signals.This includes :
199Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing ofhoods & LED lamp units with current regulating transformer on 2aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity.
200Wiring & testing of signal unit as per the specifications and directives of engineer at site.
201Testing & commissioning of 2 /3/4aspect colour light signals.
202Excavation of pit, casting & plastering of concrete foundation for shunt signal.As per Drg. NoRITES/SIG/GEN/002-98.This includes : Supply of foundation nuts & Bolts, cement, sand, stone chip & mixingin the ratio 1:3:6.
203Erectionof shunt signal.This includes :
204a). Erection of surface base, shunt signal post, shunt signal unit.
205b). Fixing ofhoods and LED lamps with regulating transformer.
206c). Termination of the tail cable in the signal unit.
207d). Wiring of shunt signal unit with wiring material.
208e) Necessary arrangement of material to be used by bidder own arrangement.
209Excavation of pit, casting of concrete foundationsfor full location box as perDrg.No.RITES/CO/S&T/03/09This includes : Supply of Foundation Bolts and nuts, cement, sand, stone chip & mixing in the ratio 1:3:6.
210Erection of full location box on foundation including fixing of `E"type lock & locking arrangement,wiring, testing & commissioning as per approved disposition plan& wiring diagram. Thisincludes -
211(i). Necessary arrangement of material& fixing of hylum sheet on 25 x 25 x 3 mm angle iron frame , resin bonded 10 mm thick grade P3 in standard size for shelves, boardfor fixing ARA terminal, disconnecting type terminal blocks, fuse blocks etc.
212(ii). Termination of cables with number embossed ferrules, bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.This also includes clamping of cables with contractors own material
213(iii). Filling up pit inside the location box by sand and plastering on the topof the sand.
214(iv).Fixing of terminals, 8 way strips, disconnecting type terminal blocks, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams.
215Excavation of pit, casting of concrete foundations for half location box as per as per TS para.-8 &9 and Drg.No.RITES/CO/S&T/04/09. This includes: (i) Supply of 4 nos. anchor bolts as per RDSO drawing no. SA-112A with nuts and washers. (ii) Supply of cement, sand, stone chip & mixing in the ratio 1:3:6.
216Erection of half location box on foundation including fixing of `E" type lock & locking arrangement wiring, testing & commissioning as per approved disposition plan & wiring diagram. This includes : (i) Supply & fixing of hylum sheet, resin bonded 10 mm thick grade P3 for fixing ARA terminal, fuse blocks etc. (ii) Bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc. (iii) Filling up pit inside the location box by sand and plastering on the top of the sand. (iv) Fixing of angle iron frame for "Q" type relays in location box. This includes supply of angle iron for fixing relays. (v) Fixing of terminals, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams .
217Supply and Installation of Earth electrode assembly and concrete encloser with cover as per drg. No. RITES/SIG/GEN/013-98 and RITES/SIG/GEN/014-98 respectively. This includes providing connection to location box, signalunit, block instruments, cables etc. through GI wire 8 SWG suitably sparted on MS flats size 30 x 3 mm as per drg.No. RITES/SIG/GEN/015-98,RITES/SIG/GEN/016-98 & RITES/SIG/GEN/017-98. This includes: (i) Digingof pit in earth 3 m deep. (ii) Casting of cement concrete enclosure as per drg.No.RITES/SIG/GEN/014-98. (iii) Soil treatment as per standard practice involving supply & pouring of salt & charcoal. (iv) Connecting the equipment through earth lead wire & soldering. (v) Supply of cement,wiring material & soldering material.
218Dismantling of the following: -
219Signal posts/BSLB/SLB/Stop Board.
220Steel apparatus case with fittings.
221TLJB/Point JB
222Location Foundation/ Signal Foundation.
223ALL INDOOR
224Point MACHINEWITH Ground fitting
225Hand point lever
226Painting of two coats ofenamelpaint over one coat ofRed oxide primer on the following items after scrapping and cleaning of the surface whereever necessary. Primer & paints both Asian make are to be supplied by contractor. Location boxes inside & outside surfaces with Aluminium paint.
227Full case
228Half case
229Painting of Main signal post with signal unit,surface base complete with route indicator, dependent shunt, calling On unit, ladderfittings as per Indian.Rlys. standard practice.
230Painting of two coats ofenamelpaint black Asian and Aiuminiumwhite asapproved by Site engineer over one coat ofprimeron Shunt signal unit , base and post
231Painting of two coats ofenamelpaint black Asian and red oxide asapproved by Site engineer over one coat ofprimeron point machine and ground connection respectively
232Necessary arrangement of material, installation & commissionig ofPre-wired Crank Handle cum key lock relay box along with LEDs, TEKNIC make push buttons, 8-way terminal strips, string rod etc. as per instructions of Engineer at site.
233Cement concrete work for miscellaneous items with supply of cement, sand, stone chips and mixing in the ratio 1:3:6. This item includes excavation, raming, curing and plastering with cement & sand mixture (stone chips size not exceeding 40mm).
234Providing brick massonary in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides. 20mm thick each with contractor"sown IInd nd class bricks including excavation curing, grouting,bolting etc.Whereever required bricks sand and cement to be supplied by the contractor.
235Blowing of OFC through HDPE duct & protective work (elicited in above item) already provided.Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn/laid manually as per standard procedure.All the equipments and machinery required shall be arranged by the contractor at his own cost.In case OFC is to be laid adopting Direct in trench method then this item shall be paid as per accepted rate of item no. (6h) of this schedule.OFC and HDPE pipe shall be supplied by the railway.
236Installation, testing & commissioning of ingle Section Digital Axle Counter Systemcomplete by OEM or itsauthorised dealer. The axle counter will be Single Section type with two detection points and it ispossible to install it without trolley protection track circuit.The axle counter must consist of following: (a) Mounting of high frequency TX and RX coil-2 sets, each set consist of web mounting type 2 Nos. of TX and 2 Nos. of RX. TX & RX shall be supplied by Rly. (b) Mounting of track side digital axle counter Unit-2 Nos. (c) Fixing of vitalrelays etc. duly wired-2 Nos.(d) Clamping with deflectorplate andhardware formounting of two set of TX & RX coil. (e) Resetting arrangementof each axle counter. (f) All the wiring material required forinstallation and commissioning shall be arranged by contractor. (g) This also includesintegration with existing SGE/Tokenless/Token blockinstruments were required as per instructions of siteengineer. The wire and other wiring material will be arranged by contractor at site.
237Training of Technician/Jr. Engineers in installation, Testing, commissioning & trouble shooting of MSDAC system supplied against item no. - 11 of Bill-1, including supply of hard copies of course modules for each trainee.
238Training of Sr. Engineers/Managers in installation, Testing, commissioning, trouble shooting and Repairs of MSDAC system supplied against item no. 11 of Bill-1, including supply of hard copies of course modules for each trainee.
239Installation of desk type magneto telephone with all accessories including standard battery box and 3nos. of 6I cells. All materials for this installation including standard battery box and 6I cells will be supplied by the contractor. Only desk type magneto telephone will be supplied by Railway(included as separate item of this schedule).
240Installation and commissioning of 25W radio at station building. This includes erection of power supply unit and antenna with support pipe.
241Maintenance of all the indoor and outdoor signalling gears installed at SWS yard of Bokaro Steel Plant including EI and MSDAC systems. Note: (i)Materials, which are covered under defect liability / warranty period in terms of contract provisions and required for maintenance of signalling system(s), shall be supplied by the contractor free of cost.(ii) Materials, which are not covered under defect liability / warranty period in terms of contract provisions and required for maintenance of signalling system(s), shall be supplied by Bokaro Steel.
242Supply & Erection of Prefabricated hut (Pota Cabin) size 4.4Mtr X 4.26 mtr as per Design and TS . This shall inculde the elctrification of the Fabticated hut.Material & execution of elctrificationitems will be paid under Electrical BOQ. Before supplying pota hut contractor will get the approval from site engineer.
243Schedule-2 (Track Works)
244Supply and fixing of 15"x12"x6" 1in 8.5 turn out wooden sleeper no-3&4 to suit BG 52 kg as per RDSO Drawing.
245Supply and fixing of insulated leading and following stretcher bars as per RDSO Drawing
246Supply & fixing of slide chair as per RDSO Drawing
247Supply & fixing of MS plate as per RDSO Drawing
248Supply & fixing of insulated Gauge as per RDSO Drawing
249Supply & fixing of plate screw as per RDSO Drawing
250Supply & fixing of Coil washer as per RDSO Drawing
251Supply & fixing of Bolts & Nuts with coil spring as per RDSO Drawing
252Removal of Existing wooden /PSC/Steel Sleeper no-3 & 4 by removing the pendrol clips of existing toung rails.
253Inserting in track Metal / Wooden sleeper lying along the cess / formation /slope / toe with all fittings complete for TSR / ISD work to specified gauge withcontractor’s tools including one packing to make track fit for 20 kmph speedand dressing of ballast, as directed by Engineer in-charge
254For location of work not involving deep screening
255Supply of Elastic Rail Clips ("J-Clips") for fish plated rail joints to RDSO Drawing No. T-4158
256Supply of Grooved rubber sole plate suitable for 52/60 kg rail on 60 kg PSC sleepers as per drg No RDSO/ T-3711
257Supply of cast iron brackets for fixing at check rail along with bolts & nuts, packing plates, spring washers etc. conforming to latest IRS specification and RDSO drg.60 0kg running rail+52kg check rail
258Through renewal of Metal / GFN liners in running track condition includingremoving, cleaning & lubrication of ER Clip & Insert Eye and re-driving thesame with contractor"s grease graphite of approved quality with all lead & lift
259Schedule-3 (Electrical Works)
260WIRING AND DISTRIBUTION BOARDS
261LIGHT/FAN/EX.FAN/CALL BELL POINTS
262Wiring for light point/fan point/exhaust fan point/call bell point with1.5 sq.mm. FRLS PVC insulated, copper conductor single core cable in surface/recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
263a)Group C
264CIRCUIT WIRING : (FOR LIGHT/FAN /EX.FAN /CALL BELL)
265Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cables in surface/recessed steel conduitas required.
266a) 2x 2.5 sq.mm + 1x 2.5 sq.mm earth wire
267b) 2x4 sqmm+1x4 sqmm
268c) 2x6 sqmm+1x6 sqmm
269SUB-MAIN WIRING:-
270Wiring for circuit/sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit as required.
271a) 4x 16 sq.mm + 2 x 16 sq.mm earth wire
272Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
2732 Pair
274Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
27525mm
27615/16A SWITCH SOCKET OUTLET:
277Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6& 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
278Wiring for light/power plug with 2 x 4 sq.mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 no. 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
2795/6 SWITCH SOCKET OUTLETS:-
280supplying and fixing following modular switch/socket on the existing modular plate & Switch box including connections but excludingmodular plate etc. as required.
281a) 5/6amps switch
282b) 3 Pin 5/6 amp socket outlet
283c) 15/16amps switch
284d) 6 pin 15/16amps switch
285e) Telephone socket outlet
286supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
287a) (75 mm X 75 mm)
288b)(100 mm X 75 mm)
289c) 6 Module (200 mm X 75 mm)
29020 A METAL CLAD SOCKET OUTLETS:-
291supplying and fixing 20 amps, 240 volts,SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps ""C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2925amp single pole
293Distribution Boards & MCB:-
294Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper busbar, neutral busbar, earth bar, din bar, inter connections, powder painted including earthing etc. as required (but without MCB/RCCB/Isolotor).
2954 way Single Door
296Supplying and fixing following rating four pole, (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc.as required.
29763 amps
298Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissiong etc as required.
299Single Pole
300Installation, testing and commissioning of pre-wired, LED fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVCinsulated, copper conductor, single core cable and earthing etc. as required.
301Supplyingand fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
302Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with. 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
303Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
304Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required
305Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required
306a) 35 sq. mm
307b) 4x 35 sqmm
308c) up to 35sqmm
309Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required.
310100 mm dia
311BRASS COMPRESSION GLAND
312Supplying andmakingend termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3133.5 C x 50 sq. mm (35 mm)
314EARTHING:-
315Earthing withG.I. earth pipe 4.5 metere long 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
31632mm
317Supplying and laying 25 x 5 mm GI strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm)
318Providing and fixing 25 mmx 5 mm G.I. strip on surface or in recess for connections etc.as required.
319Schedule B
320Non Schedule items (Electrical Works)
321SUPPLY & INSTLLATION OF LIGHT FITTING & FANS:-
322Supply and erection of LED recessed mounted down light fitting with LED similar to catalogue no. 32W LED LHEWEBP7UL1W032, Havells make including all accessories, connecting wires, cost conveynence and all taxes etc. complete in all respect . (Make: Phillips,bajaj, CG,Havells)
323Supplyof surface mounted ceiling light as per bajaj CAT no. BCSC218 CFL W2EB orequivalent approved make approved equivalent make mentioned in the list of approved make of materials. including 2X18 watt CFLcomplete in all respects.
324Supply, installation, testing and commissioning of 230V A. C ceiling fan 1200mm with double ball bearing and suitable capacitor complete with wiring with 1.5 sq.mm FR PVC insulated copper conductor, single/ three core cable as instructed etc. as required.
325Supply of 12" (305 mm) dia (900 rpm) single phase exhaust fan with frame, louvers & bird screen including hardware for fixing complete in all respect including shutter.
326Supply, erection, testing and commissioning of LED Street light fitting ,pressure di-cast aluminium housingwith suitable cover, suitable to work on 220-240V AC supply with system wattageas under :
32760W
328Supplying, erection, Testing and commissioning of , Split typeairconditioner complete with remote control, sweeping arrangement in the cool air outlet category of 3 star (and other accessories and 4 KVA wall mountedCopper model stabilizer of voltage range (90 V to 280 V).
329Split type
330Supplying and laying extra copper refrigerent pipe
331Supplying and laying of suitable PVC drinage pipe for indoor unit of AC
332(Main Distribution Board)
333Supply, erection, testing & commissioningof indoor type Main Distribution Boardfloor mountingtype dust and vermin proof by contstruction of 1.6 mm CRCA sheets with bolted construction powder coatedpanel as specification below :-
334Incomer
335100 amps, 25 KA, 4P, MCCB - 1 No. (Thermal release, Rotary Handle)
336Spreader Link - 1 Set
337RYB Indicating lamps with PF - 1 Set
338Multi Function Meter - 1 No.
339CT 100/ 5 A - 1 Set
340125 amps 4 P Changeover Switch - 1 No.
341Outgoing
34263 amps TPN MCB, C Curve - 2 Nos.
34340 amps TPN MCB, C Curve - 2 Nos.
344Busbar Rating
345One Set 100 amps TPN, 25 KA for 1 Sec. at Copper busbars with colour coated heat shrinkable PVC sleeves and suitable Size.
346Note: MCCB, MCB & Changeover Switch - L&T, Legrand, Siemens approved make.
347LT Cable
348Supply of 1.1 KV grade LT XLPE cable insulated aluminium conductor armoured cable to IS: 7098 (PT-1) including Testing and commissioning of the cables.
3493.5 C x 50 mm2
350Supply & lowering&fixing of KSB make 4C/10 similler type submerssible pump moter set 3 phase AC 1.5HP capable discharge water 75M length and suitable electrical panel operating complete
351Drilling 7 boring hole sinking of tubewell of 150mm using manual/D.T.H process through rock and holder upto the depth as requre
352Schedule-4 (Building Works)
353Foundation
354Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 3 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 3 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
355Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. In layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m.
356Providing and laying in position cement concrete of specified grade excludingbthe cost of centering and shuttering - All work up to plinth level :
357a) 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
358b) 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
359Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering,
360a) All works upto Plinth Level
361b) All works above plinth level upto floor V level
362Supplying and filling in plinth withsand under floors including,watering,ramming, consolidating and dressing complete.
363Brick work with F.P.S bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 (1Cement : 6 coarse sand)
364Brick work with F.P.Sbricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 Cement : 6 coarse sand)
365Half brick masonary with F.P.S bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement:4 coarse sand)
366Half brick masonary with F.P.S bricks of class designation 7.5 in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement:4 coarse sand)
367Brick work withbricks of class designation 7.5 in foundation and plinth in Cement mortar:1:4 (1 cement: 4 coarse sand ),
368Extra for brickwork in superstructure above plinth level upto floor V level. - CM : 1:4 (1 cement: 4 coarse sand)
369Supplying and placing in position High Strength Deformed Steel bars reinforcemetn . (confirming to IS 1786 Grade Fe 500) for RCC works including transporting the steel straightening, cleaning,cutting, bending, binding to required shapes and lenghts as per drawing including the cost of binding wire 18 SWGas needed. Steel shall be from main producers such as SAIL,RINL & TISCO. Rates shall include the cost of protective coating of truncated inhibitedcement slurry.
370Providing and fixing ISI marked flush door shutters confirming to IS 2202 (Part -I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
371a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
372b) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
373Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs of dash fastener shall be paid for separately).
374Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
375a) 12mm cement plaster of mix 1:6 (1cement : 6 coarse sand).
37615mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1cement : 6 coarse sand).
3776mm cement plaster to ceilling of mix 1:3(1cement: 3 fine sand).
37812 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
379Providing and fixing 10 mm thick acid and or/ alkali resistance tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and /or alkali resisting cement as per IS: 4457, complete as per the direction of enfgineer-in-charge.
380a) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement:4 coarse sand) - Acid and alkali resistant tile
381b) in dado/skirting on 12 mm thick mortar1:4 (1 acid proof cement: 4 coarse sand) - Acid and alkali resistant tile
382Providing and fixing 1st quality wall ceramic glazed wall tiles conforming to IS:15622 of minimum thickness 5 mm of approved make like NITCO, ORIENT, SOMANY KAJARIA, or equivalent make in all colours, shades except begundy, bottle green , black of any size as approved by Enginner -in-charge in skirting, risers of steps and dados over 12 mm thick bed of Cement Mortar 1:3 (1 Cement :3 Coarse sand) and jointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment ofmatching shades complete.
383Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality confirming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete.
384Providing and fixing IS : 12817 marked stainless steel butt hinges withstainless steel screws etc. complete :
385a) 25x64x1.90 mm
386b) 100X58X1.90 mm
387Cement Plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement of 18 mm thick.
388Cement concrete flooring(1:2:4 5mm thck wioth 20mm nominal size stone aggregate
389Providing rubber floor tile plain rubber tile confirming to IS:809 1.5mm thick
390Painting with synthetic enamel paint of approved brand and manufactureof required color to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
391Distempering with oil bound washable distemper of approved brand(Asian,Nerolack) and manufacture to give an even shade new work (two or more coats) over and including priming coat with cement primer.
392Making plinth protection 50 mm thick of cement concrete1:3:6(1 cement:3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
393Finishing walls with water proofing cement paint "Snowcem - Plus" of M/s Asian, Berger Ltd. or equivalent of required shade:New work (Two or more coats applied @ 3.84 Kg/10 Sqm.)
394Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 25 to 40mm nominal bore.
395Providing and Fixing brass stop cock of approved quality. 15mm nominal bore.
396Providing and Fixing C.P.Brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690gms.
397a) 15mm nominal bore.
398Providing and Fixing C.P.Brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
39915mm nominal bore
400Providing and Fixing G.I. Pipes complete with GI.Fittings and clamps, including cutting and making good the walls etc. (internal work).
401a) 15mm dia. Nominal bore.
402b) 25mm dia nominal bore.
403Providing and Fixing gun metal gate value with CI wheel of approved quality (screwed end) 25mmNominal bore.
404Providing and fixing water closet squatting pan (Indian type W.C. Pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, Parryware /Hindware / Seabird / Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.White Vitreous chinaOrissa pattern W.C. pan of size 580 x 440mm with integral type foot rests.
405Providing and Fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality colour and make, weighing not less than 105gms (Prayag or equivalent)
406Providing and Fixing PTMT towel ring trapezoidal shape 215mm long, 200mm wide with a minimum distances of 37mm from wall face with concealed fittings arrangement of approved quality, colour and make weighing not less than 88gms (Prayag or equivalent)
407Providing and Fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP Brass screws with concealed fitting arrangement of approved quality colour and make (Prayag or equivalent)450mm long towel rail with total length of 495mm, 78mm wide and effective hight of 88mm, weighin not less than 170gms.
408Providing and Fixing PTMT shelf 440mm long, 124mm width and 36mm height of approved quality, colour and make, weighing not less than 300gms (Prayag or equivalent)
409Providing and fixing kitchen sink including making all connections excluding cost of fittings with White glazed fire clay sink of size 600 x 450 x 250 mm
410Providingand fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require with white vitreous China wash basin size 630 x 450 mm with a pair of 15mm C.P brass pillar taps.
411Providing and Fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. Flexible pipe,40mm dia.
412Constructing masonry chamber 90x90x100 cm, inside with 75 class designation brick work in cement morter 1:4 (1 cement:4 fine sand) for sluice valve, with C.I. surface box 100mm. Top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) neccessary excavation foundation concrete 1:5:10(1 cement:5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design. With F.P.S bricks.
413Making soak pit 2.5 diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W drain pipe 100 mm diameter 1.8m long complete as per standard design. With F.P.S bricks
414Providing M.S. foot rests including fixing in manholes with 20 x 20 x 10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sane : 6 graded stone aggregate 20 mm nominal size) as per standard design with 20 x 20 mm square bar.
415Supply and fixing C.I cover without frame for manholes with 500 mm diameterC.I cover (medium duty ) the weight of thecover to be notless than 58 Kg. (frame + cover) = ( Rs 2507.35 +Rs2507.35 )=Rs 5014.70
416Providing and fixing wash basin with C.I./M.S brackets, 15mm C.P brass pillar taps,Kingston / Gem / Techno / Parko, 32mm C.P brass waste of standard pattern, including painting of fittingsand brackets, cutting and making good the walls wherever require: Flat back wash basin size 550 x 400mm with single 15mm C.P. brass pillar tap.
417Providing & fixing urinal of 580mmx380mmx350mm with white PVC automatic flushing cistern IS:2556
418Providing and fixing 600 x 450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete.
419Providing and fixing soil, waste and vent pipes : 100mm dia. sand cast iron S & S pipe.
420Providing and Fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete. Flexible pipe,40mm dia.
421Providing and fixing 100mm sand cast Iron grating for gully trap.
422Providing & fixing 100mm S.C.I. trap with 100mm inlet and 100mm outlet.
423Providing and fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. (1) Single socketed pipes. 110mm diameter.
424a) Bend 87.5 degree,110mm bend
425b) Shoe (plain), 110mm shoe
426Providing and fixing M.S.holder bat clamps of approved design to C.I. or S.C.I. Rain water pipes embeded in and including cement concrete blocks 10 x 10 x 10cm of 1:2:4 mix (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and cost of cutting holes and making good the walls etc. 100mm diameter.
427Providingandplacingontarrace(at all floor levels) polyethylene water storage tank IS:12701 marked indicating the BIS license No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (Sintex,Electroplast,Star,Lotusor equivalent having valid ISI License).
428Providing and fixing S.W. intercepting trap in manholes with stiff mixture of cement mortar 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete – 150 mm dia.
429Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
430150 mm diamete
431Providing and Fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
432300x10mm
433250x10 mm
434Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required color or shade with necessary screws etc. Complete 125mm.
435Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screwsetc. complete :
436300x16 mm
437Providing andfixingfactory made ISImarkedsteelglazed doors, windows and ventilators side/top/centre hung with beading and all members suchas F7D, F4B, K11 B and K12 B etc.complete of standard rolled sections, joints mitred and welded and sash bars tenoned and rivetedwith 15 x 3mm lugs, 10cm long, embedded in cement concrete blocks 15 x 10 x 10cm of 1:3:6 (1cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and apriming coat of approved steel primer excluding the coast of metal beading and other fittings except necessary hinges of pivots complete as per approved design.(sectional weight of only steel members shall be measured for payment).
438Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
439Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
4409.118 Providing and fixing to existing door frames.
441a) With float glass panes of 4.0 mm thickness
44224 mm thick factory made PVC door shutters made of stylesand rails of a uPVC hollow section of size 59x24 mm and wallthickness 2 mm (± 0.2 mm) with inbuilt edging on both sides.The styles and rails mitred and joint at the corners by meansof M.S. galvanised/ plastic brackets of size 75x220 mm havingwall thickness 1.0 mm and stainless steel screws. The stylesof the shutter reinforced by inserting galvanised M.S. tube ofsize 20x20 mm and 1 mm (± 0.1 mm) wall thickness. Thelock rail made up of "H" section, a uPVC hollow section of size100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to theshutter styles by means of plastic/galvanised M.S. "U" cleats.The shutter frame filled with a uPVC multi-chambered singleThe shutter frame filled with a uPVC multi-chambered singlepanel of size not less than 620 mm, having over all thicknessof 20 mm and 1 mm (± 0.1 mm) wall thickness . The panelsfilled vertically and tie bar at two places by inserting horizontally6 mm galvanised M.S. rod and fastened with nuts andwashers, complete as per manufacturer"s specification anddirection of Engineer-in-charge.
443Providing and fixing factory made P.V.C. door frame of size 50x47 mmwith awall thickness of 5 mm, made out of extruded 5mm rigid PVCfoam sheet, mitred at corners and joined with 2 Nos of 150 mm longbrackets of 15x15 mm M.S. square tube, the vertical door frame profilesto be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDMrubber gasket weather seal to be provided through out the frame. Thedoor frame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer’s specification and direction of Engineein-Charge.
444Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete
445With 12 mm mild steel U beading
446Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
447Centering and shuttering including strutting, propping etc. and removal of form for all heights Foundations, footings, bases of columns, etc. for mass concrete :
448Columns, Pillars, Piers, Abutments, Posts and Struts
449pvc pipe for electrical work 25mm dia