Military Engineer Services-MES has published Special Repairs To Compound Wall Between Offrs Mess And Girls Area , Near Contingent Cdr Block And Jcos Living , Replacement Of Ac Sheet Roofing With Cgi Sheet In 14 Girls Bks Provn Of New Granite On Concrete Pillars At Gate No 2 , Speed Brakers On In. Submission Date for this Tender is 29-07-2021. Shed Construction Tenders in GE (East) Delhi Cantt-10 Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 05-Jul-2021 | Amendments in BOQ | BOQ | 22-07-2021 |
2 | 13-Jul-2021 | Amendments | BOQ | 22-07-2021 |
3 | 22-Jul-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-07-2021 |
Name of Work : SPL REPAIRS TO COMPOUND WALL BETWEEN OFFRS MESS AND GIRLS AREA, NEAR CONTINGENT CDR BLOCK AND JCOs LIVING, REPLACEMENT OF AC SHEET ROOFING WITH CGI SHEET IN 14 GIRLS BKS PROVN OF NEW GRANITE ON CONCRETE PILLARS AT GATE NO 2, SPEED BRAKERS ON INTERNAL ROADS OF DGNCC CAMP AND 01 STORE ROOM NEAR P-7A AT POLO ROAD IN THE AREA OF AGE B/R - III UNDER GE (EAST) DELHI CANTT - 10. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and as directed. | 10 | Cum | |
2 | 2 | Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and as directed. | 0.8 | Cum | |
3 | 3 | Demolition of brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, complete all as specified and as directed. | 129 | Cum | |
4 | 4 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified and as directed. | 2.6 | 10 Sqm | |
5 | 5 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings, complete all as specified and as directed. | 2061 | Sqm | |
6 | 6 | Surface excavation in soft/loose soil not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and as directed. | 115 | Sqm | |
7 | 7 | Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr deep and getting out complete in soft/loose soil, complete all as specified and as directed. | 55.75 | Cum | |
8 | 8 | Excavation in trenches not exceeding 1.5mtr wide and exceeding 1.5mtr deep but not exceeding 3.0mtr deep and getting out complete in soft/loose soil, complete all as specified and as directed. | 3 | Cum | |
9 | 9 | Returning, filling in, including spreading, leveling watering and well raming in layers not exceeding 25cms thick complete all as specified and as directed. | 28.9 | Cum | |
10 | 10 | Removal of surplus soil to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed. | 29.9 | Cum | |
11 | 11 | Hard core of gauge not exceeding 63mm stone aggregate, deposited, spread and levelled in layers not exceeding 15 cm thick watering and ramming to a true surface, complete all as specified and directed | 10 | Cum | |
12 | 12 | Plain cement concrete 1:4:8, Type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and as directed. | 6.6 | Cum | |
13 | 13 | Plain cement concrete 1:2:4 type B- 1 using 20mm graded crushed stone aggregate as in window or door cills, lintels, bressumers, steps, quoins blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundry pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone wlling), corbels, brackets etc. (of any indicated section), with plain fair faces, including chamfes, weathering, throaing etc., and set in cement mortar 1:4 with matching joints, complete all as specified and as directed. | 2.5 | Cum | |
14 | 14 | RCC M-25 Design Mix ( using 20mm graded crushed stone aggregate) as in foundations footings, plinth beams etc., complete all as specified and directed. | 13.8 | Cum | |
15 | 15 | RCC M-25 Design Mix ( using 20mm graded crushed stone aggregate) as in columns, pillars etc., complete all as specified and directed. | 5.8 | Cum | |
16 | 16 | RCC M-25 Design Mix using 20mm graded crushed stone aggregate, as in beams, cantilevers, bressumers, lintels over 1.5mtr span and the like, complete all as specified and as directed. | 16 | Cum | |
17 | 17 | RCC M-25 Design Mix ( using 20mm graded crushed stone aggregate) as in roof/floor slabs supported on walls, beams and shelves etc., complete all as specified and directed. | 11.5 | Cum | |
18 | 18 | RCC M-25 Design Mix ( using 20mm graded crushed stone aggregate) as in chajjas, shelves etc., complete all as specified and directed. | 2.5 | Cum | |
19 | 19 | Pre-cast cement concrete (1:2:4), type B-O, using 12.5mm graded stone aggregate as in 40mm thick louvers and jallies, including mouldings & frame work, set in cement mortar 1:4, complete all as specified and as directed. | 90 | Sqm | |
20 | 20 | Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:6 using old size bricks, including demolition of brick work built in cement mortar, complete all as specified and as directed. | 13 | Cum | |
21 | 21 | Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:6 using old size bricks, complete all as specified and as directed. | 159 | Cum | |
22 | 22 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and as directed. | 52 | Sqm | |
23 | 23 | Use and waste of formwork to sides of columns, pillars, posts dtruts etc., for fair finished surfaces of concrete, complete all as specified and as directed. | 74 | Sqm | |
24 | 24 | Use and waste of form work to soffits and sides of floor and roof beams, beam haunchings, bressumers, lintels, cantilevers, shelves including supports and overhangs for fair finished concrete surfaces, complete all as specified and as directed. | 152 | Sqm | |
25 | 25 | Use and waste of form work to soffits of suspended slabs such as roof slabs, shelves etc., not exceeding 200mm thickness for fair finished concrete surfaces, complete all as specified and as directed. | 72 | Sqm | |
26 | 26 | Use and waste of form work to soffits of chajjas, chullah hoods and similar type of work etc., for fair finished concrete surfaces, complete all as specified and as directed. | 10 | Sqm | |
27 | 27 | Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and as directed. | 34 | RM | |
28 | 28 | 18-20mm thick Granite stone slab (table rubbed and polished) in steps, shelves, and the like not less than 1Sqm (in one piece), laid over 20mm thick layer of cement mortar 1:3 after rougheniung of existing concrete surface and applying a layer of neat cement slurry @ 3Kg/Sqm including pointing in white cement 1:2 using marble dust with admixture of pigments to match with shade of stone, including moulding of edges, complete all as specified and as directed. | 45 | Sqm | |
29 | 29 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm, and fixed with tinned tacks or galvanised mild steel staples, complete all as specified and as directed. | 18 | Sqm | |
30 | 30 | Curtain rod/rail of anodised Aluminium rod fancy type 20mm dia including roller and roller plate fixed to wooden/mild steel brackets, complete all as specified and as directed. | 25 | RM | |
31 | 31 | Box type Steel windows with double shutters (inside for wiremesh & out side for glass), hinges, steel handle, tower bolt and steel peg stay complete with glazing bars dovetailed or welded including a coat of red oxide after preparation of surface before fixing all as shown in drg No. TD-A sheet 1/3 to 3/3, complete all as specified and as directed. | 13 | Sqm | |
32 | 32 | Box type Steel windows with double shutters (inside for wiremesh & out side for glass), hinges, steel handle, tower bolt and steel peg stay complete without glazing bars dovetailed or welded including provision for AC/desert cooler opening and cover including a coat of red oxide after preparation of surface before fixing all as shown in drg No. TD-A sheet 1/3 to 3/3, complete all as specified and as directed. | 13 | Sqm | |
33 | 33 | Mild steel framed work as in doors (as in chowkats) or gates of angle or other section with gusset plates, rails, braces etc., exclusive of steel sheeting or other covering, hanging or fastening and fixing complete conforming to Gde Fe-410-0 or Fe-310-0 including shop coat of red oxide including preparation of surface before fixing, complete all as specified and as directed. | 190 | Kg | |
34 | 34 | Mild steel framed work as in grills, gratings etc., with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladder, framed balusters, railing, frame work for water tanks and similar work, complete conforming to Fe 290 Gde-E-165 including shop coat of red oxide including preparation of surface before fixing, complete all as specified and as directed. | 707 | Kg | |
35 | 35 | Mild steel TMT bars upto 10mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hopping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0, complete all as specified and as directed. | 7465 | Kg | |
36 | 36 | TMT bars 5mm dia and over upto and including10mm dia cut to length, in stirrups and spacers including cutting and bending, hooking ends & binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. | 1820 | Kg | |
37 | 37 | Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. | 1910 | Sqm | |
38 | 38 | Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws, complete all as specified and as directed. | 151 | Sqm | |
39 | 39 | 15mm thick screed bed in cement mortar 1:4 on concrete surfaces over top of roof slabs to receive water proofing treatment, finished even and rough, complete all as specified and as directed. | 85 | Sqm | |
40 | 40 | 15mm thick screed bed in cement mortar 1:4 on concrete surfaces over top of roof slabs to receive water proofing treatment, finished even and rough, complete all as specified and as directed. | 60 | Sqm | |
41 | 41 | E-board 4mm thick self design type tiles ceiling on GI Powder coated channel/Tee/Grid of make(Armstrong or equivalent) frame work with the following specification including cutting holes to brick wall built in cement mortar & making good in cm 1:3 of cement concrete 1:2:4 type BO complete all as specified and as directed.\n(a) Plugging to wall around the rooms & supplying & fixing GI Powder coated angle of size 25mm x 25mm x 1.0mm \n(b) S&F of 1.60 mm dia GI wire suspenders with adjustable clamps including fixing to ceiling dash free fasterers\n(c) S&F 25mm x 25mm x1.5mm GI Powder coated tee as in main & cross members at 595mm c/c supported suspenders alongwith adjustable clamp to maintain level. \n( d) S&F E-board 4mm thick self design type ceiling tiles of size 595mm x 595mm confirming to relevant IS in squares of GI Powder coated Tee with clips made to shape. Shade and pattern of Gypsum board shall be as approved by GE | 245 | Sqm | |
42 | 42 | 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate, as in sub base to receive topping layer finished even and rough, complete all as specified and as directed. | 80 | Sqm | |
43 | 43 | Machine cut kota stone slab 18-20mm thick as in floors laid, bedded and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to mirror finish complete including screed bed or bedding layer of mortar 20mm thick in cement mortar 1: 4 for laying floor finishes, complete all as specified and as directed. | 85 | Sqm | |
44 | 44 | Machine cut kota stone slab 18-20mm thick as in as in vertical surfaces of dados/skirtings/sides of pillars etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick backing layer in cement mortar 1:4 including dismantling of old tiles with backing, complete all as specified and as directed. | 11 | Sqm | |
45 | 45 | 75 MM thick plain Cement Concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) finished even and fair at top without using extra cement and providing joints 40mm deep and 12 mm wide in plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as and as directed. | 20 | Sqm | |
46 | 46 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified and as directed. | 195 | Sqm | |
47 | 47 | Rendering 5mm thick on fair faces of concrete surfaces as in ceilings in cement mortar 1:3 finished even and smooth without using extra cement, complete all as specified and as directed. | 80 | Sqm | |
48 | 48 | Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and as directed. | 931 | Sqm | |
49 | 49 | Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and as directed. | 26 | Sqm | |
50 | 50 | Preparation of newly plastered or unplastered surface of ceilings and applying three coats of white wash, complete all as specified and as directed. | 80 | Sqm | |
51 | 51 | Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified and as directed. | 195 | Sqm | |
52 | 52 | Preparing newly plastered surfaces of wall and applying two exterior acrylic emulsion weather shield paint over a coat of primer, complete all as specified and as directed. | 931 | Sqm | |
53 | 53 | Preparation of new steel surfaces and applying two coats of synthetic enamel paint on surfaces of any description exceeding 10 cm width or girth over a coat of red oxide, complete all as specified and as directed. | 55 | Sqm | |
54 | 54 | Sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and as directed. | 12 | Sqm | |
55 | 55 | Heavy duty speed breaker and supports loads of up to 40 tons with all connected fixing accessories and the colour of the sppeed breaker is black and yellow and height min 50mm and width 300mm completed all as specified and as directed by Engr in Charge. Make : Model H2PB75-3 of H2 Safety India Pvt Ltd or equivalent in Dark Eye/3M. | 35 | RM | |
56 | 56 | Point wiring complete with 1.5 Sqmm (nominal area) FRLS, PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS, PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size for fixing modular switches/sockets/fan regulator etc , with and including Modular cover plates of suitable size and making good surface as original by plastering, whitewash/colour and distemper etc complete all as specified and as directed for the following :-\n one light point / fan point/ wall fan point/ bell/ buzzer controlled by one 1-way switch/ bell push. | 14 | Per Point | |
57 | 57 | All as per description of Srl item No. 56 here-in-before but for one socket outlet 5/6 Amps on same board. | 3 | Per Point | |
58 | 58 | All as per description of Srl item No. 56 here-in-before but for one socket outlet 5/6 Amps on independent board. | 2 | Per Point | |
59 | 59 | Replacement of Switch piano flush type, single pole, one way, 5/6 Amps, complete all as specified and as directed. | 19 | Each | |
60 | 60 | Replacement of socket two-in-one, 5 pin, 5/6 Amp universal type, complete all as specified and as directed. | 5 | Each | |
61 | 61 | Replacement of electronic fan regulator flush type, in step and making all necessary connections, complete all as specified and as directed. | 1 | Each | |
62 | 62 | PVC insulated armoured XLPE heavy duty U/G aluminium conductor cable served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and overall PVC sheathed of size 6Sqmm 2 core, complete all as specified and as directed. | 35 | RM | |
63 | 63 | Material and labour for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable, complete all as specified and as directed. | 217 | Each | |
64 | 64 | Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as directed. | 2.03 | Cum | |
65 | 65 | MCB DB confirming to IP 43 - IK 09 with double door, SPN 08 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces, complete all as specified and as directed. | 1 | Each | |
66 | 66 | MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specified and as directed. | 4 | Each | |
67 | 67 | MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole and Neutral of 32 to 63 Amp capacity, complete all as specified and as directed. | 1 | Each | |
68 | 68 | Replacement of Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps and making good surface as original by plastering and whitewash/ colour/ distemper etc., complete all as specified and as directed. | 13 | Each | |
69 | 69 | Ceiling fan 1200mm sweep 240volts, double bearing with 1 Star BEE rating, ISI marked including provision of hanging arrangement for hanging in ceilings and making all necessary electric connections, complete all as specified and as directed. | 1 | Each | |
70 | 70 | Fresh air fan 250mm sweep plastic body with self closing louvers including fixing in opening and making all necessary electric connections, complete all as specified and as directed. | 2 | Each | |
71 | 71 | Wall mounting tube light fitting, 22 watt including making all electric connections using PVC Sheathed copper conductor flexible cable, complete all as specified and as directed. | 7 | Each | |
72 | 72 | LED security light luminaire 45 watt pressure die cast aluminium housing with heat resistance toughned glass and IP- 66 protection with and including driver/transformer and including connector, complete all as specified and as directed.\n | 4 | Each | |
73 | 73 | Street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with nut, bolts, washer etc., inclusive of one primer coat, one under coat and one finishing coat of silver paint, complete all as specified and as directed. | 4 | Each | |
74 | 74 | Earthing complete with GI earth plate electrode 600 mm x 600mm x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20 mm dia for watering pipe with funnel, wire mesh, salt, charcoal dust and excavation, complete all as specified and as directed. | 1 | Each Job | |
75 | 75 | NOTE:- For minimum fair wages ,EPF and payment to labour employed, refer Sch A Note No-17,18 and Special Condition No 5 & 21.2 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record. | |||
76 | 76 | NOTE:- Irrespective of whatever specified elsewhere in tender documents, all the debris/waste materials produced out of above mentioned work shall be removed out of Cantonement land and disposed off at locations notified by the Delhi Cantonment Board for disposal of waste building materials within NCR area, without any extra cost to Department under own arrangement of contractors. The rates quoted by the contractors against the items catered here-in-above in the BOQ are inclusive of said provision. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail