Provision Of Boom Barrier At Main Gate Of Cg Complex Malkapuram Visakhapatnam And Provision Of Geysers In C1 Building Type Iii Accommodation At Icgs Malkapuram Under Age I Cg Vizag, VISAKHAPATNAM-Andhra Pradesh

Military Engineer Services-MES has published Provision Of Boom Barrier At Main Gate Of Cg Complex Malkapuram Visakhapatnam And Provision Of Geysers In C1 Building Type Iii Accommodation At Icgs Malkapuram Under Age I Cg Vizag. Submission Date for this Tender is 14-07-2021. Gate Barrier Systems Tenders in VISAKHAPATNAM Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28262151
Corrigendum : Provision Of Boom Barrier At Main Gate Of Cg Complex Malkapuram Visakhapatnam And Provision Of Geysers In C1 Building Type Iii Accommodation At Icgs Malkapuram Under Age I Cg Vizag
Open Tender
Indian
Andhra Pradesh
VISAKHAPATNAM
14-07-2021

Tender Details

Provision Of Boom Barrier At Main Gate Of Cg Complex Malkapuram Visakhapatnam And Provision Of Geysers In C1 Building Type Iii Accommodation At Icgs Malkapuram Under Age I Cg Vizag

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Jun-2021 DATE CORRIGENDUM Date 07-07-2021
2 30-Jun-2021 F BID corrigendum Financial Bid 07-07-2021
3 07-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-07-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 38000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: PROVISION OF BOOM BARRIER AT MAIN GATE OF CG COMPLEX MALKAPURAM, VISAKHAPATNAM & PROVISION OF GEYSERS IN C1 BUILDING (TYPE-III) ACCOMMODATION AT ICGS MALKAPURAM UNDER AGE (I) (CG) VIZAG.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply, install, fixing, testing and commissioning of Automatic Boom Barrier of length 6 meter of Stainless steel material with battery backup supply including Electrical parameters as specified and necessary PCC/Brick work required for installation of equipement.\nMake - Leaptor/Dorma/Patson Hydro tech (PHT) or equivalent. Dimension(D*W*H) 280*355*1050 mm \nIngress protection IP 55 \nFrequency 50 Hz \nWorking temperature -20 to 70 degree \nWeight excluding barrier boom 50 Kgs \nSupply Single phase \nMax Boom length up to 6 m \nPoom profile Octgonal \nPower Consumption 60 W \nOpening/ closing time Up to 6 sec speed \nDrive AC\nMTBF 5 Million \nAutomatic Boom Barrier straight 6 MTR \nClear opening of Boom Arm 5.7 m, \nLED indication lights on casing, Metal Casing with powder coating & Aluminium boom with CE certiifed as per European standards EN 61000-61-2007/ 2008 having protection grade of IP 65 with Manual Push Button- 1 no, \nBoom stand-1 Nos, \nRemote Controll - 2 Nos, \nSafety photocell -1 Nos \nPair Access Control System : \n(i) UHF reader for entry and exit 2\n(ii) UOM 2 Door Controller with standard dekstop based software 1 \n(iii) Windshield Tags (2 & 4 wheeler) RO\nNote- Standard installation to be carried out and material required shall be inclusive in unit rate. 1 Each
2 2 Supply, Install, fixing , testing and commissioning of Elecromechanical Tyre Killer Upto 8 meter, steel weight capacity- upto 70 ton, Protection Level-IP 45 (Fire cabinet IP-65) 230 V Power, 1 KW Power consumption including Electrical and ciivl works (Cutting of land, PCC not less than 600 m wider and not less than 8-9 metter in length, including necessary earth work, PCC work frame work\nMake- Leaptor/ Dorma/Patson Hydro Tech (PHT) or equivalent\nMaterial Galvanized steel\nType Special HUMP/FLAT type\nspike size 25 mm\nLength 3-8 m\nOpening CLosing Time 3-4 sec\nPOwer Supply 230V 50 Hz\nPower Consumption utpo 1 KW\nCurrent Consumption upto 10 amp maximum\nDrive TYpe Electromechanical\nAccessories max current 500 mA\nSpike height 150 mm\nBlocking Angle 45 deg to 60 deg\nLoad Capacity 70 Ton\nEnvironment temperature O0C to + 55 0C\nNote- standard installation to be carried and material required shall be induced in unit rate.\n 1 Each
3 3 Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth and getting out in soft/loose soil complete all as speciifed and as directed 19.44 Cum
4 4 Returning, fitting in including spreading, levelling, watering & well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. 12.47 Cum
5 5 Removing excavated soil/ demolished material not exceeding 50 Mtr from the starting point complete all as specified and as directed. 5.72 Cum
6 6 Material and labour for dry river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as specified in relevant clasue of SSR Part -I 9.72 Cum
7 7 Material and labour for Bricks common burnt clay builidng brick, sub class 'A' designation 75 work in trenches above the cable all as directed. 0.65 Per 1000 Nos.
8 8 Supply ,laying and testing of XLPE insulated, armoured heavy duty electric cable with aluminum conductor, 1100 volts grade, cross-sectional area 4 sq mm 2 core complete all as specified and as directed.\nMake : FINOLEX / ANCHOR / HAVELLS / PLAZA/KEI 50 RM
9 9 Supply ,laying and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core.\nMake : FINOLEX / ANCHOR / HAVELLS / PLAZA/KEI 40 RM
10 10 M&L for Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification. 1 Each Set
11 11 Supply, installing & Testing of Water heater (Geyser) storage type of capacity 25 liters, 02 KW capacity, glass lined coated inner tank, suitable installation with grouting of Nuts, Bolts and washers of suitable size as recommend by the manufacturer including 02 KW heating element, cable of suitable size as recommended by manufacturer, with 3 pin plug Top of suitable capacity, etc complete all as specified and as directed at site by the Engr-in-charge.\nMake: V-Guard Model No Steamer Plus EC or equivalent in the makes detailed in list of makes in Particular Specifications.\n 48 Each
12 12 Supply and laying 16 mm outer dia UPVC pipe including all fittings in trenches/walls/cellings or laying in floors complete all as specified and as directed. 192 RM
13 13 S & F stop valve, cost copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed of size 15 mm complete all as specifed and as directed at site.\n Make- Jaquar or equivalent in the makes detailed in list of makes in Particular Specifications. 48 Each
14 14 S & F Bib taps, Chromium plated , fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed of size 15 mm complete all as specifed and as directed at site.\nMake- Jaquar or equivalent in the makes detailed in list of makes in Particular Specifications. 48 Each
15 15 S & F PVC connection for Hot Water 15 mm with CP nuts and bolts and washers of length 600 mm complete all as specifed and as directed at site. 48 Each
16 16 S & F PVC connection for cold Water 15mm with CP nuts and bolts and washers of length 750 mm complete all as specifed and as directed at site. 48 Each
17 17 Supply and fixing socket combination 2 - in -1 5 pin and 15 Amps complete all as specified ans as directed. 48 Each
18 18 Supply and fix Sub main wiring with 2 runs of single core, 4 Sqmm PVC unsheathed, copper multistranded conductor, ISI marked, drawing into and including PVC heavy duty conduit, 25 mm dia with all accessories, surface type duly earthed with 2.5 Sqmm, single core, PVC insulated unsheathed cable, copper conductor, multistranded complete all as specified and as directed.\nNote :- 2 run of 4 Sqmm & 1 run of 2.5 Sqmm and one run of PVC conduit will be measured as one unit.\nMake of cable : FINOLEX / ANCHOR / HAVELLS / PLAZA\nMake of PVC Conduit: FINOLEX / SUPREME / PRINCE / TIRUPATI / SUDHAKAR/PRESTO PLAST 480 Rm
19 19 S&F On/Off Push Botton switch 15 amps, 230V AC complete all as specified and as directed . \nMake- Legrand or equivalent in the makes detailed in list of makes in Particular Specifications. 48 Each