Uttar Pradesh Projects Corporation Limited has published Construction Of Dharmashala , Parking Shed , Development Of Park And Landscaping Works At Shri Makhaoda Dham , Harraiya Distt- Basti ( U . P . ) . Submission Date for this Tender is 03-07-2021. Shed Construction Tenders in BASTI Uttar Pradesh. Bidders can get complete Tender details and download the document.
Name of Work: CONSTRUCTION OF DHARMASHALA, PARKING SHED, DEVELOPMENT OF PARK &LANDSCAPING WORKS AT SHRI MAKHAODA DHAM, HARRAIYA DISTT- BASTI (U.P.) | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backalite sheet etc.complete in all respect as directed including matching colour wash. | BI01010001010000000000000515BI0100001113 | 114 | each |
2 | 2 | Wiring point for two ways light point with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box and two number two ways piano type switches & ceiling rose/angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc., complete in all respect,as directed, including matching colour wash. | BI01010001010000000000000515BI0100001114 | 1 | each |
3 | 3 | Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet,etc.complete in all respect,as directed, including matching colour wash. | BI01010001010000000000000515BI0100001115 | 41 | each |
4 | 4 | Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in riggid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & socket etc.complete in all respect,as directed, including matching colour wash. | BI01010001010000000000000515BI0100001116 | 30 | each |
5 | 5 | Supply fixing & concealing of PVC conduit in the wall including cutting of brick laying of conduit & fixing it with MS hooks & then plastering.with cement, sand,mortar finished to the level,with matching colour wash including cost of proper thrading of conduit and providing necessary socket ,bend & chucknuts,as directed by engineer incharge with the supply of material labour and T&P required for proper completion of work. | BI01010001010000000000000515BI0100001117 | ||
6 | 6 | Size 20 mm dia 16SWG (2 mm)thick | BI01010001010000000000000515BI0100001118 | 80 | rmt |
7 | 7 | Size 25 mm dia 16SWG (2 mm)thick | BI01010001010000000000000515BI0100001119 | 60 | rmt |
8 | 8 | Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable,with 5 amp flush type switch and 3 pin socket on existing board ,complete with 1.5 sq mm FRLSH PVC insulated multistrand copper conductor cable as earth wire.etc.complete in all respect,as directed, including matching colour wash. | BI01010001010000000000000515BI0100001120 | 28 | each |
9 | 9 | Add for light /fan point with moduler type switch in place of piano type switch. | BI01010001010000000000000515BI0100001121 | 155 | each |
10 | 10 | Add for 2 way light point with moduler type switch in place of piano type switch. | BI01010001010000000000000515BI0100001122 | 1 | each |
11 | 11 | Add for plug point with moduler type switch in place of piano type switch. | BI01010001010000000000000515BI0100001123 | 30 | each |
12 | 12 | Submains (Copper Wires) | BI01010001010000000000000515BI0100001124 | ||
13 | 13 | Supply & wiring of submains with 2 nos.1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. | BI01010001010000000000000515BI0100001125 | 580 | rmt |
14 | 14 | Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with 1 no. 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. | BI01010001010000000000000515BI0100001126 | 360 | rmt |
15 | 15 | Supply & wiring of submains with 2 nos.4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 2.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. | BI01010001010000000000000515BI0100001127 | 180 | rmt |
16 | 16 | Supply & wiring of submains with 4 nos. 6 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 4 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including maching colour wash etc.complete in all respect. | BI01010001010000000000000515BI0100001128 | 80 | rmt |
17 | 17 | Supply & wiring of submains with 4 nos.10 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 40 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 6 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. | BI01010001010000000000000515BI0100001129 | 80 | rmt |
18 | 18 | ELCB/ RCCB Switches | BI01010001010000000000000515BI0100001130 | ||
19 | 19 | Supply and fixing of 40 amp DP 30 mA ELCB/ RCCB of Din Rail mounting in DB complete in all respect with connections as required. | BI01010001010000000000000515BI0100001131 | 3 | each |
20 | 20 | Supply and fixing of 63 amp DP 30 mA ELCB/ RCCB of Din Rail mounting in DB complete in all respect with connections as required. | BI01010001010000000000000515BI0100001132 | 3 | each |
21 | 21 | Light & Fan Fixture | BI01010001010000000000000515BI0100001133 | ||
22 | 22 | Supply & fixing of Batton/Angle holder including making connection etc. as required. | BI01010001010000000000000515BI0100001134 | 20 | each |
23 | 23 | Supply and fixing of recess/surface/pendent mounting round 6 to 8 W LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. Complete in all respect. CAT. - AAA | BI01010001010000000000000515BI0100001135 | 30 | each |
24 | 24 | Supply and fixing of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. CAT. - AAA | BI01010001010000000000000515BI0100001136 | ||
25 | 25 | 1100-1650 system lumens, 1101m/W, PF>0.95, THD<10% at full load, CRI>80, with 5 year warrantee | BI01010001010000000000000515BI0100001137 | 16 | each |
26 | 26 | Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED tube light Complete including tube etc on surface complete in all respect. CAT. - AAA | BI01010001010000000000000515BI0100001138 | 30 | each |
27 | 27 | 2420 system lumens, 110 Im/W, PF>0.95, THD<10%, CRI>80, sheet Thickness 0.8 mm, Tube with aluminium heat with 5 year warrantee | BI01010001010000000000000515BI0100001139 | ||
28 | 28 | Supply and fixing of Single LED light Wall Bracket 3 to 6 Watt on matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA | BI01010001010000000000000515BI0100001140 | 4 | each |
29 | 29 | Supply and fixing of 3 watt to 4 watt LED (spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a decorative mirror light) | BI01010001010000000000000515BI0100001141 | 14 | each |
30 | 30 | 330-660 system lumens 1101m/W, PF>0.95, THD<20% at full load , with 5 year warrantee | BI01010001010000000000000515BI0100001142 | ||
31 | 31 | Supply of ceilling fans with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50 Hz, 1-Ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. | BI01010001010000000000000515BI0100001143 | ||
32 | 32 | BEE 5 Star rated-1200 mm sweep | BI01010001010000000000000515BI0100001144 | 25 | each |
33 | 33 | Cables/Gland/Lug | BI01010001010000000000000515BI0100001145 | ||
34 | 34 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size | BI01010001010000000000000515BI0100001146 | ||
35 | 35 | size 50 sq mm x 3-1/2core | BI01010001010000000000000515BI0100001147 | 200 | rmt |
36 | 36 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable | BI01010001010000000000000515BI0100001148 | ||
37 | 37 | Size 50 sq mm x 3-1/2core | BI01010001010000000000000515BI0100001149 | 4 | each |
38 | 38 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable | BI01010001010000000000000515BI0100001150 | ||
39 | 39 | Size 50 sq mm | BI01010001010000000000000515BI0100001151 | 12 | each |
40 | 40 | Chemical Earthing System | BI01010001010000000000000515BI0100001152 | ||
41 | 41 | Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated,Length 3000mm,outer pipe 48.4mmx3.2mm,inner pipe 26.9mm x 2.6 mm,terminal Dia 12mm,coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. | BI01010001010000000000000515BI0100001153 | 2 | each |
42 | 42 | Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects. | BI01010001010000000000000515BI0100001154 | 30 | rmt |
43 | 43 | Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side. | BI01010001010000000000000515BI0100001155 | 30 | rmt |
44 | 44 | L.T. Switch Panel Board | BI01010001010000000000000515BI0100001156 | ||
45 | 45 | Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. | BI01010001010000000000000515BI0100001157 | ||
46 | 46 | Same as above description (or As per requirment directed by project manager.) CAT. B Cubicle Type | BI01010001010000000000000515BI0100001158 | 1 | each |
47 | 47 | Incoming - | BI01010001010000000000000515BI0100001159 | ||
48 | 48 | 100 Amp MCCB -1 No. (Use as 63 Amps Incomer) | BI01010001010000000000000515BI0100001160 | ||
49 | 49 | Outgoing - | BI01010001010000000000000515BI0100001161 | ||
50 | 50 | 40 Amp DP MCB - 1 Nos. | BI01010001010000000000000515BI0100001162 | ||
51 | 51 | 63 Amp DP MCB - 1 Nos. | BI01010001010000000000000515BI0100001163 | ||
52 | 52 | 32 Amp DP MCB - 2 Nos. (Spare) | BI01010001010000000000000515BI0100001164 | ||
53 | 53 | 32 Amp 4P MCB - 1 Nos. (Spare) | BI01010001010000000000000515BI0100001165 | ||
54 | 54 | DBs & MCBs | BI01010001010000000000000515BI0100001166 | ||
55 | 55 | Supply and fixing of 240 volts C Curve 6-32 amp SP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A | BI01010001010000000000000515BI0100001167 | 42 | each |
56 | 56 | Supply and fixing of 240 volts C Curve 40 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A | BI01010001010000000000000515BI0100001168 | 1 | each |
57 | 57 | Supply and fixing of 240 volts C Curve 63 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A | BI01010001010000000000000515BI0100001169 | 1 | each |
58 | 58 | Supply and fixing of flush/surface mounting 6 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A | BI01010001010000000000000515BI0100001170 | 1 | each |
59 | 59 | Supply and fixing of flush/surface mounting 8 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A | BI01010001010000000000000515BI0100001171 | 1 | each |
60 | 60 | Supply & Fixing of MCB blanking plate for DB. | BI01010001010000000000000515BI0100001172 | 4 | each |
61 | 61 | Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules | BI01010001010000000000000515BI0100001173 | 1 | each |
62 | 62 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. | BI01010001010000000000000515BI0100001174 | 25 | each |
63 | 63 | Supply and Fixing of shock treatment chart.prescribed as per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work. | BI01010001010000000000000515BI0100001175 | 1 | each |
64 | 64 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules | BI01010001010000000000000515BI0100001176 | 2 | each |
65 | 65 | Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work. | BI01010001010000000000000515BI0100001177 | 20 | each |
66 | 66 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. | BI01010001010000000000000515BI0100001178 | 25 | each |
67 | 67 | Supply fixing of electronic fan regulator (Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. | BI01010001010000000000000515BI0100001179 | 25 | each |
68 | 68 | Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001180 | 3 | each |
69 | 69 | Supplying and fixing TV antenna socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001181 | 2 | each |
70 | 70 | Supplying and drawing FRLSH PVC insulated annealed copper conductor, unarmoured cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair | BI01010001010000000000000515BI0100001182 | 75 | rmt |
71 | 71 | Supplying and drawing UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required. | BI01010001010000000000000515BI0100001183 | 50 | rmt |
72 | 72 | Supplying and drawing Co axial T V cable, RG-6 grade, 0.7 mm solid copper conductor, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. | BI01010001010000000000000515BI0100001184 | 30 | rmt |
73 | 73 | Supply & Fixing of Moduler switch blanking plate for Moduler switch board. | BI01010001010000000000000515BI0100001185 | 20 | each |
74 | 74 | Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. | BI01010001010000000000000515BI0100001186 | ||
75 | 75 | 1 or 2 Module (75mmX75mm) | BI01010001010000000000000515BI0100001187 | 7 | each |
76 | 76 | 3 Module (100mmX75mm) | BI01010001010000000000000515BI0100001188 | 30 | each |
77 | 77 | 4 Module (125mmX75mm) | BI01010001010000000000000515BI0100001189 | 15 | each |
78 | 78 | 6 Module (200mmX75mm) | BI01010001010000000000000515BI0100001190 | 20 | each |
79 | 79 | 8 Module (125mmX125mm) | BI01010001010000000000000515BI0100001191 | 18 | each |
80 | 80 | 12 Module (200mmX150mm) | BI01010001010000000000000515BI0100001192 | 16 | each |
81 | 81 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (Use as a A.C. Power Plug) | BI01010001010000000000000515BI0100001193 | 2 | each |
82 | 82 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) | BI01010001010000000000000515BI0100001194 | 50 | mtr |
83 | 83 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia | BI01010001010000000000000515BI0100001195 | 20 | rmt |
84 | 84 | Supply and fixing of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including making connection.Complete in all respect. | BI01010001010000000000000515BI0100001196 | 20 | each |
85 | 85 | Supply and fixing of AC 230mm Sweep, 230/250 Volts, 50 Hz exhaust fan (light Duty) with blades,cover etc. complete as required | BI01010001010000000000000515BI0100001197 | 16 | each |
86 | 86 | Supplying and fixing LAN socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001198 | 2 | each |
87 | 87 | FIRE FIGHTING WORK | BI01010001010000000000000515BI0100001199 | ||
88 | 88 | Manual Fire Alarm System : | BI01010001010000000000000515BI0100001200 | ||
89 | 89 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. | BI01010001010000000000000515BI0100001201 | 2 | NOS |
90 | 90 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. | BI01010001010000000000000515BI0100001202 | 2 | NOS |
91 | 91 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. | BI01010001010000000000000515BI0100001203 | 2 | NOS |
92 | 92 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. | BI01010001010000000000000515BI0100001204 | 40 | metre |
93 | 93 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. | BI01010001010000000000000515BI0100001205 | 40 | metre |
94 | 94 | Fire Fighting System : Fire Extinguishers | BI01010001010000000000000515BI0100001206 | ||
95 | 95 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. | BI01010001010000000000000515BI0100001207 | 2 | Each |
96 | 96 | Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. | BI01010001010000000000000515BI0100001208 | 2 | Each |
97 | 97 | Street Light (6.0 mtr. Pole) | BI01010001010000000000000515BI0100001209 | ||
98 | 98 | Supply & fixingof 6.0 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) in 1:2:4 RCC foundation includingthe cost of foundation,foundation bolts,excavation & back filling and Required T&P completee in all respect. | BI01010001010000000000000515BI0100001210 | 6 | Nos. |
99 | 99 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 to 72 Watt. Confirming to IP 66 and above Protection complete in all respect. CAT AAA | BI01010001010000000000000515BI0100001211 | 6 | Set |
100 | 100 | supply and fixing of 25 amp SPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors , HRC fuse , isolating switch , metering instrument and instrument box with CTs etc.complete in all respect. | BI01010001010000000000000515BI0100001212 | 1 | Set |
101 | 101 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size | BI01010001010000000000000515BI0100001213 | ||
102 | 102 | size 6 sq mm x 2 core | BI01010001010000000000000515BI0100001214 | 60 | rmt |
103 | 103 | size 10 sq mm x 2 core | BI01010001010000000000000515BI0100001215 | 40 | rmt |
104 | 104 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable | BI01010001010000000000000515BI0100001216 | ||
105 | 105 | size 6 sq mm x 2 core | BI01010001010000000000000515BI0100001217 | 6 | each |
106 | 106 | size 10 sq mm x 2 core | BI01010001010000000000000515BI0100001218 | 2 | each |
107 | 107 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable | BI01010001010000000000000515BI0100001219 | ||
108 | 108 | size 6 sq mm | BI01010001010000000000000515BI0100001220 | 12 | each |
109 | 109 | size 10 sq mm | BI01010001010000000000000515BI0100001221 | 4 | each |
110 | 110 | PARKING SHED-1 | BI01010001010000000000000515BI0100001222 | ||
111 | 111 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. | BI01010001010000000000000515BI0100001223 | 18.006 | CUM |
112 | 112 | Filling of carted earth. | BI01010001010000000000000515BI0100001224 | 45.448 | CUM |
113 | 113 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.(Including Royality) | BI01010001010000000000000515BI0100001225 | 75.004 | CUM |
114 | 114 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. | BI01010001010000000000000515BI0100001226 | 41.793 | CUM |
115 | 115 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) | BI01010001010000000000000515BI0100001227 | 424.5 | SQM |
116 | 116 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. For the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001228 | 3.94 | CUM |
117 | 117 | Boring providing & installing cast-in-situ single under reamed pile of specified dia and length below pile cap in cement concrete with mix M-20 of 20mm nominal size of grit to size to carry a safe working load not less than specified excluding the cost of steel reinforcement but including boring with pentonide solution and length of pile to embedded in the pile cap. 300 mm dia Piles (P1) | BI01010001010000000000000515BI0100001229 | 156 | RM |
118 | 118 | As in item 209 above but in R.C.C. Raft foundation and footing with stone ballast.(Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001230 | 6.21 | CUM |
119 | 119 | As in item 209 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. | BI01010001010000000000000515BI0100001231 | 0.486 | CUM |
120 | 120 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001232 | 5769.08 | KG |
121 | 121 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. | BI01010001010000000000000515BI0100001233 | 636.468 | SQM |
122 | 122 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified | BI01010001010000000000000515BI0100001234 | 487.313 | SQM |
123 | 123 | Providing and laying of Interlocking Concrete Block Pavements having thicknes 80mm including leveling and dressing of surface to required level and slope spreading and moisting 30mm thick local sand on bend filling joints with local sand etc, for proper completion of the work as per drawing and Technical specification clause1504. | BI01010001010000000000000515BI0100001235 | 500.025 | SQM |
124 | 124 | PARKING SHED-II (2 Nos) | BI01010001010000000000000515BI0100001236 | ||
125 | 125 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. | BI01010001010000000000000515BI0100001237 | 22.85 | CUM |
126 | 126 | Filling of carted earth. | BI01010001010000000000000515BI0100001238 | 43.994 | CUM |
127 | 127 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.(Including Royality) | BI01010001010000000000000515BI0100001239 | 86.446 | CUM |
128 | 128 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. | BI01010001010000000000000515BI0100001240 | 48.092 | CUM |
129 | 129 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) | BI01010001010000000000000515BI0100001241 | 424.5 | SQM |
130 | 130 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001242 | 7.88 | CUM |
131 | 131 | Boring providing & installing cast-in-situ single under reamed pile of specified dia and length below pile cap in cement concrete with mix M-20 of 20mm nominal size of grit to size to carry a safe working load not less than specified excluding the cost of steel reinforcement but including boring with pentonide solution and length of pile to embedded in the pile cap. 300 mm dia Piles (P1) | BI01010001010000000000000515BI0100001243 | 156 | RM |
132 | 132 | As in item 222 above but in R.C.C. Raft foundation and footing with stone ballast.(Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001244 | 4.32 | CUM |
133 | 133 | As in item 222 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. | BI01010001010000000000000515BI0100001245 | 0.972 | CUM |
134 | 134 | Mild steel or iron work of small sizes & sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for & welding, grinding & making holes as required fabrication of holes doors, chaukhats nosing. | BI01010001010000000000000515BI0100001246 | 8341.01 | KG |
135 | 135 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. | BI01010001010000000000000515BI0100001247 | 167.892 | SQM |
136 | 136 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified | BI01010001010000000000000515BI0100001248 | 487.312 | SQM |
137 | 137 | Providing and laying of Interlocking Concrete Block Pavements having thicknes 80mm including leveling and dressing of surface to required level and slope spreading and moisting 30mm thick local sand on bend filling joints with local sand etc, for proper completion of the work as per drawing and Technical specification clause1504. | BI01010001010000000000000515BI0100001249 | 576.3 | SQM |
138 | 138 | DEVELOPMENT WORK OF PARK (Road Side Development) | BI01010001010000000000000515BI0100001250 | ||
139 | 139 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. | BI01010001010000000000000515BI0100001251 | 365.72 | CUM |
140 | 140 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. | BI01010001010000000000000515BI0100001252 | 81.02 | CUM |
141 | 141 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. | BI01010001010000000000000515BI0100001253 | ||
142 | 142 | As in item 232 above but in R.C.C. Raft foundation and footing with stone ballast.(Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001254 | 12 | CUM |
143 | 143 | As in item 232 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001255 | 7.04 | CUM |
144 | 144 | As in item no. 232 above but for slabs (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001256 | 16.69 | CUM |
145 | 145 | M-150 brick work in in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand). | BI01010001010000000000000515BI0100001257 | 219.94 | CUM |
146 | 146 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. | BI01010001010000000000000515BI0100001258 | 33.56 | QTL |
147 | 147 | 25mm thick Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete with base of cement mortar. | BI01010001010000000000000515BI0100001259 | 659.8 | SQM |
148 | 148 | PARK DEVELOPMENT | BI01010001010000000000000515BI0100001260 | ||
149 | 149 | Concrete with 4 cm gauge stone ballast, coarse sand of 1.25 fm fineness modules and cement in the proportion 1:4:8 in foundation including supply of all materials, labour tools and plants etc. (PWD-281) | BI01010001010000000000000515BI0100001261 | 228.2 | Cum |
150 | 150 | P/L of 80mm thick Inter locking bricks in Pathway including all material etc. (SI No- Ch- 20 NS) | BI01010001010000000000000515BI0100001262 | 1576.43 | Sqm |
151 | 151 | LANDSCAPING OF PARK | BI01010001010000000000000515BI0100001263 | ||
152 | 152 | Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). | BI01010001010000000000000515BI0100001264 | 632.37 | CUM |
153 | 153 | Carrigae of sludge upto 5 K.M. | BI01010001010000000000000515BI0100001265 | 632.37 | CUM |
154 | 154 | Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm | BI01010001010000000000000515BI0100001266 | 105.4 | CUM |
155 | 155 | Carrigae of manure upto 5 K.M. | BI01010001010000000000000515BI0100001267 | 105.4 | CUM |
156 | 156 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. | BI01010001010000000000000515BI0100001268 | 737.77 | CUM |
157 | 157 | Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately). | BI01010001010000000000000515BI0100001269 | 737.77 | CUM |
158 | 158 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). Holes 0.9 m dia. and 0.90 m deep. | BI01010001010000000000000515BI0100001270 | 350 | NO. |
159 | 159 | Plantation of trees. (Decorative Plants) | BI01010001010000000000000515BI0100001271 | 350 | EACH |
160 | 160 | Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. | BI01010001010000000000000515BI0100001272 | 2107.9 | Sqm |
161 | 161 | PAVILION (3 NOS) | BI01010001010000000000000515BI0100001273 | ||
162 | 162 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. | BI01010001010000000000000515BI0100001274 | 14.85 | CUM |
163 | 163 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. | BI01010001010000000000000515BI0100001275 | 3.681 | CUM |
164 | 164 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. | BI01010001010000000000000515BI0100001276 | 2.667 | CUM |
165 | 165 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) | BI01010001010000000000000515BI0100001277 | 17.787 | SQM |
166 | 166 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. | BI01010001010000000000000515BI0100001278 | ||
167 | 167 | As in item no. 256 above but for slabs (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001279 | 6.564 | CUM |
168 | 168 | As in item no. 256 above but for Beam (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001280 | 3.651 | CUM |
169 | 169 | As in item no. 256 above but for Footing (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001281 | 2.43 | CUM |
170 | 170 | As in item no. 256 above but for Column (Using 1:1.5:3 Mix concrete) | BI01010001010000000000000515BI0100001282 | 2.317 | CUM |
171 | 171 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. | BI01010001010000000000000515BI0100001283 | 2.841 | CUM |
172 | 172 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. | BI01010001010000000000000515BI0100001284 | 13.563 | QTL |
173 | 173 | 20mm Thick cement plaster in two coats, backing coat 17mm and finishing coat 3mm thick on rough side of single or half brick wall for interior plastering up to floor two level including arises, internal rounded angle chamfers and or rounded angle not exceeding 30mm in grith and finished even and smooth. (i) 1 cement: 3 coarse sand | BI01010001010000000000000515BI0100001285 | 52.5 | SQM |
174 | 174 | Laying of 25mm thick KOTA stone of size 45x45 cm and above flooring over previously prepared base with 2 cm thick 1:3 cement and sand mortar including filling of joints with cement mixed with pigment required for matching the shade of floor as per direction of E/I including cutting polishing with wax polish including supply of all materials T &P etc. required for proper completion of the work. | BI01010001010000000000000515BI0100001286 | 25.887 | SQM |
175 | 175 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) | BI01010001010000000000000515BI0100001287 | 146.301 | SQM |
176 | 176 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | BI01010001010000000000000515BI0100001288 | 146.301 | SQM |
177 | 177 | Cartage earth filling in the campus with watering ramming and proper compaction of earth. | BI01010001010000000000000515BI0100001289 | 3126.74 | CUM |
178 | 178 | GST Extra as applicable | BI01010001010000000000000515BI0100001290 |