Construction Of Dharmashala , Parking Shed , Development Of Park And Landscaping Works At Shri Makhaoda Dham , Harraiya Distt- Basti ( U . P . ) , BASTI-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Construction Of Dharmashala , Parking Shed , Development Of Park And Landscaping Works At Shri Makhaoda Dham , Harraiya Distt- Basti ( U . P . ) . Submission Date for this Tender is 03-07-2021. Shed Construction Tenders in BASTI Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

28241762
Construction Of Dharmashala , Parking Shed , Development Of Park And Landscaping Works At Shri Makhaoda Dham , Harraiya Distt- Basti ( U . P . )
Open Tender
Indian
Uttar Pradesh
BASTI
03-07-2021

Tender Details

Construction Of Dharmashala , Parking Shed , Development Of Park And Landscaping Works At Shri Makhaoda Dham , Harraiya Distt- Basti ( U . P . )

Key Value

Document Fees
INR 17700 /-
EMD
INR 269000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: CONSTRUCTION OF DHARMASHALA, PARKING SHED, DEVELOPMENT OF PARK &LANDSCAPING WORKS AT SHRI MAKHAODA DHAM, HARRAIYA DISTT- BASTI (U.P.)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backalite sheet etc.complete in all respect as directed including matching colour wash. BI01010001010000000000000515BI0100001113 114 each
2 2 Wiring point for two ways light point with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box and two number two ways piano type switches & ceiling rose/angle/batten holder on 3mm thick , phenolic laminated backelite sheet etc., complete in all respect,as directed, including matching colour wash. BI01010001010000000000000515BI0100001114 1 each
3 3 Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy gauge rigid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & ceiling rose /angle/batten holder on 3mm thick , phenolic laminated backelite sheet,etc.complete in all respect,as directed, including matching colour wash. BI01010001010000000000000515BI0100001115 41 each
4 4 Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in riggid steel conduit pipe Partly concealed in the wall and partly Laid in slab along with the reinforcement before concreting ,complete with 1.5sqmm. FRLSH PVC insulated multistrand single core copper conductor cable as earth continuity wire , GP box, piano type switch & socket etc.complete in all respect,as directed, including matching colour wash. BI01010001010000000000000515BI0100001116 30 each
5 5 Supply fixing & concealing of PVC conduit in the wall including cutting of brick laying of conduit & fixing it with MS hooks & then plastering.with cement, sand,mortar finished to the level,with matching colour wash including cost of proper thrading of conduit and providing necessary socket ,bend & chucknuts,as directed by engineer incharge with the supply of material labour and T&P required for proper completion of work. BI01010001010000000000000515BI0100001117
6 6 Size 20 mm dia 16SWG (2 mm)thick BI01010001010000000000000515BI0100001118 80 rmt
7 7 Size 25 mm dia 16SWG (2 mm)thick BI01010001010000000000000515BI0100001119 60 rmt
8 8 Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable,with 5 amp flush type switch and 3 pin socket on existing board ,complete with 1.5 sq mm FRLSH PVC insulated multistrand copper conductor cable as earth wire.etc.complete in all respect,as directed, including matching colour wash. BI01010001010000000000000515BI0100001120 28 each
9 9 Add for light /fan point with moduler type switch in place of piano type switch. BI01010001010000000000000515BI0100001121 155 each
10 10 Add for 2 way light point with moduler type switch in place of piano type switch. BI01010001010000000000000515BI0100001122 1 each
11 11 Add for plug point with moduler type switch in place of piano type switch. BI01010001010000000000000515BI0100001123 30 each
12 12 Submains (Copper Wires) BI01010001010000000000000515BI0100001124
13 13 Supply & wiring of submains with 2 nos.1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 1.5 sqmm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. BI01010001010000000000000515BI0100001125 580 rmt
14 14 Supply & wiring of submains with 2 nos.2.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy gauge rigid steel conduit partly concealed in wall and partly laid in slabalong with the reinforcement before concreting, with 1 no. 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. BI01010001010000000000000515BI0100001126 360 rmt
15 15 Supply & wiring of submains with 2 nos.4 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 1 no. 2.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. BI01010001010000000000000515BI0100001127 180 rmt
16 16 Supply & wiring of submains with 4 nos. 6 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 4 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including maching colour wash etc.complete in all respect. BI01010001010000000000000515BI0100001128 80 rmt
17 17 Supply & wiring of submains with 4 nos.10 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 40 mm dia heavy guage rigid steel conduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting, with 2 no. 6 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc.complete in all respect. BI01010001010000000000000515BI0100001129 80 rmt
18 18 ELCB/ RCCB Switches BI01010001010000000000000515BI0100001130
19 19 Supply and fixing of 40 amp DP 30 mA ELCB/ RCCB of Din Rail mounting in DB complete in all respect with connections as required. BI01010001010000000000000515BI0100001131 3 each
20 20 Supply and fixing of 63 amp DP 30 mA ELCB/ RCCB of Din Rail mounting in DB complete in all respect with connections as required. BI01010001010000000000000515BI0100001132 3 each
21 21 Light & Fan Fixture BI01010001010000000000000515BI0100001133
22 22 Supply & fixing of Batton/Angle holder including making connection etc. as required. BI01010001010000000000000515BI0100001134 20 each
23 23 Supply and fixing of recess/surface/pendent mounting round 6 to 8 W LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. Complete in all respect. CAT. - AAA BI01010001010000000000000515BI0100001135 30 each
24 24 Supply and fixing of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. CAT. - AAA BI01010001010000000000000515BI0100001136
25 25 1100-1650 system lumens, 1101m/W, PF>0.95, THD<10% at full load, CRI>80, with 5 year warrantee BI01010001010000000000000515BI0100001137 16 each
26 26 Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED tube light Complete including tube etc on surface complete in all respect. CAT. - AAA BI01010001010000000000000515BI0100001138 30 each
27 27 2420 system lumens, 110 Im/W, PF>0.95, THD<10%, CRI>80, sheet Thickness 0.8 mm, Tube with aluminium heat with 5 year warrantee BI01010001010000000000000515BI0100001139
28 28 Supply and fixing of Single LED light Wall Bracket 3 to 6 Watt on matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA BI01010001010000000000000515BI0100001140 4 each
29 29 Supply and fixing of 3 watt to 4 watt LED (spot light) fitting Confirming to IP 65 and above protection Complete in all respect. CAT. - AAA (Use as a decorative mirror light) BI01010001010000000000000515BI0100001141 14 each
30 30 330-660 system lumens 1101m/W, PF>0.95, THD<20% at full load , with 5 year warrantee BI01010001010000000000000515BI0100001142
31 31 Supply of ceilling fans with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts,50 Hz, 1-Ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. BI01010001010000000000000515BI0100001143
32 32 BEE 5 Star rated-1200 mm sweep BI01010001010000000000000515BI0100001144 25 each
33 33 Cables/Gland/Lug BI01010001010000000000000515BI0100001145
34 34 Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size BI01010001010000000000000515BI0100001146
35 35 size 50 sq mm x 3-1/2core BI01010001010000000000000515BI0100001147 200 rmt
36 36 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable BI01010001010000000000000515BI0100001148
37 37 Size 50 sq mm x 3-1/2core BI01010001010000000000000515BI0100001149 4 each
38 38 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable BI01010001010000000000000515BI0100001150
39 39 Size 50 sq mm BI01010001010000000000000515BI0100001151 12 each
40 40 Chemical Earthing System BI01010001010000000000000515BI0100001152
41 41 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated,Length 3000mm,outer pipe 48.4mmx3.2mm,inner pipe 26.9mm x 2.6 mm,terminal Dia 12mm,coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. BI01010001010000000000000515BI0100001153 2 each
42 42 Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects. BI01010001010000000000000515BI0100001154 30 rmt
43 43 Supply and fixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of work as directed at side. BI01010001010000000000000515BI0100001155 30 rmt
44 44 L.T. Switch Panel Board BI01010001010000000000000515BI0100001156
45 45 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. BI01010001010000000000000515BI0100001157
46 46 Same as above description (or As per requirment directed by project manager.) CAT. B Cubicle Type BI01010001010000000000000515BI0100001158 1 each
47 47 Incoming - BI01010001010000000000000515BI0100001159
48 48 100 Amp MCCB -1 No. (Use as 63 Amps Incomer) BI01010001010000000000000515BI0100001160
49 49 Outgoing - BI01010001010000000000000515BI0100001161
50 50 40 Amp DP MCB - 1 Nos. BI01010001010000000000000515BI0100001162
51 51 63 Amp DP MCB - 1 Nos. BI01010001010000000000000515BI0100001163
52 52 32 Amp DP MCB - 2 Nos. (Spare) BI01010001010000000000000515BI0100001164
53 53 32 Amp 4P MCB - 1 Nos. (Spare) BI01010001010000000000000515BI0100001165
54 54 DBs & MCBs BI01010001010000000000000515BI0100001166
55 55 Supply and fixing of 240 volts C Curve 6-32 amp SP miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A BI01010001010000000000000515BI0100001167 42 each
56 56 Supply and fixing of 240 volts C Curve 40 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A BI01010001010000000000000515BI0100001168 1 each
57 57 Supply and fixing of 240 volts C Curve 63 amp 4P miniature circuit breaker (10 K A ) in existing MCB, DB complete with connections as required. CAT A BI01010001010000000000000515BI0100001169 1 each
58 58 Supply and fixing of flush/surface mounting 6 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A BI01010001010000000000000515BI0100001170 1 each
59 59 Supply and fixing of flush/surface mounting 8 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by engineer incharge. CAT A BI01010001010000000000000515BI0100001171 1 each
60 60 Supply & Fixing of MCB blanking plate for DB. BI01010001010000000000000515BI0100001172 4 each
61 61 Supply and Fixing of Danger Board fabricated from 10 gauge M.S. Sheet as per I.E. Rules BI01010001010000000000000515BI0100001173 1 each
62 62 Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. BI01010001010000000000000515BI0100001174 25 each
63 63 Supply and Fixing of shock treatment chart.prescribed as per I.E. Rules.duly framed with glass and supported from back with hard board or shoft board with supply of all material ,labour,T&P for proper completion of work. BI01010001010000000000000515BI0100001175 1 each
64 64 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules BI01010001010000000000000515BI0100001176 2 each
65 65 Supply and fixing of power plug with 20A/250V flush type Moduler switch and 5 Pin 20A/250V flush type universal Moduler socket in suitable Conceled MS Box including supply of all material, labour,T&P etc.required for proper completion of work. BI01010001010000000000000515BI0100001177 20 each
66 66 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. BI01010001010000000000000515BI0100001178 25 each
67 67 Supply fixing of electronic fan regulator (Modular) 120-280 V. ISI marked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. BI01010001010000000000000515BI0100001179 25 each
68 68 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001180 3 each
69 69 Supplying and fixing TV antenna socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001181 2 each
70 70 Supplying and drawing FRLSH PVC insulated annealed copper conductor, unarmoured cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair BI01010001010000000000000515BI0100001182 75 rmt
71 71 Supplying and drawing UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required. BI01010001010000000000000515BI0100001183 50 rmt
72 72 Supplying and drawing Co axial T V cable, RG-6 grade, 0.7 mm solid copper conductor, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required. BI01010001010000000000000515BI0100001184 30 rmt
73 73 Supply & Fixing of Moduler switch blanking plate for Moduler switch board. BI01010001010000000000000515BI0100001185 20 each
74 74 Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. BI01010001010000000000000515BI0100001186
75 75 1 or 2 Module (75mmX75mm) BI01010001010000000000000515BI0100001187 7 each
76 76 3 Module (100mmX75mm) BI01010001010000000000000515BI0100001188 30 each
77 77 4 Module (125mmX75mm) BI01010001010000000000000515BI0100001189 15 each
78 78 6 Module (200mmX75mm) BI01010001010000000000000515BI0100001190 20 each
79 79 8 Module (125mmX125mm) BI01010001010000000000000515BI0100001191 18 each
80 80 12 Module (200mmX150mm) BI01010001010000000000000515BI0100001192 16 each
81 81 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. (Use as a A.C. Power Plug) BI01010001010000000000000515BI0100001193 2 each
82 82 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) BI01010001010000000000000515BI0100001194 50 mtr
83 83 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required. 50 mm dia BI01010001010000000000000515BI0100001195 20 rmt
84 84 Supply and fixing of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including making connection.Complete in all respect. BI01010001010000000000000515BI0100001196 20 each
85 85 Supply and fixing of AC 230mm Sweep, 230/250 Volts, 50 Hz exhaust fan (light Duty) with blades,cover etc. complete as required BI01010001010000000000000515BI0100001197 16 each
86 86 Supplying and fixing LAN socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001198 2 each
87 87 FIRE FIGHTING WORK BI01010001010000000000000515BI0100001199
88 88 Manual Fire Alarm System : BI01010001010000000000000515BI0100001200
89 89 Supplying, installation, testing & commissioning of addressable fire control module complete as required. BI01010001010000000000000515BI0100001201 2 NOS
90 90 Supplying, installation, testing & commissioning of addressable manual call point complete as required. BI01010001010000000000000515BI0100001202 2 NOS
91 91 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. BI01010001010000000000000515BI0100001203 2 NOS
92 92 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. BI01010001010000000000000515BI0100001204 40 metre
93 93 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. BI01010001010000000000000515BI0100001205 40 metre
94 94 Fire Fighting System : Fire Extinguishers BI01010001010000000000000515BI0100001206
95 95 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. BI01010001010000000000000515BI0100001207 2 Each
96 96 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. BI01010001010000000000000515BI0100001208 2 Each
97 97 Street Light (6.0 mtr. Pole) BI01010001010000000000000515BI0100001209
98 98 Supply & fixingof 6.0 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) in 1:2:4 RCC foundation includingthe cost of foundation,foundation bolts,excavation & back filling and Required T&P completee in all respect. BI01010001010000000000000515BI0100001210 6 Nos.
99 99 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 to 72 Watt. Confirming to IP 66 and above Protection complete in all respect. CAT AAA BI01010001010000000000000515BI0100001211 6 Set
100 100 supply and fixing of 25 amp SPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors , HRC fuse , isolating switch , metering instrument and instrument box with CTs etc.complete in all respect. BI01010001010000000000000515BI0100001212 1 Set
101 101 Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed by the Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size BI01010001010000000000000515BI0100001213
102 102 size 6 sq mm x 2 core BI01010001010000000000000515BI0100001214 60 rmt
103 103 size 10 sq mm x 2 core BI01010001010000000000000515BI0100001215 40 rmt
104 104 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earth as per direction of engineer -incharge.for cable BI01010001010000000000000515BI0100001216
105 105 size 6 sq mm x 2 core BI01010001010000000000000515BI0100001217 6 each
106 106 size 10 sq mm x 2 core BI01010001010000000000000515BI0100001218 2 each
107 107 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to cable leads for pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable BI01010001010000000000000515BI0100001219
108 108 size 6 sq mm BI01010001010000000000000515BI0100001220 12 each
109 109 size 10 sq mm BI01010001010000000000000515BI0100001221 4 each
110 110 PARKING SHED-1 BI01010001010000000000000515BI0100001222
111 111 Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. BI01010001010000000000000515BI0100001223 18.006 CUM
112 112 Filling of carted earth. BI01010001010000000000000515BI0100001224 45.448 CUM
113 113 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.(Including Royality) BI01010001010000000000000515BI0100001225 75.004 CUM
114 114 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. BI01010001010000000000000515BI0100001226 41.793 CUM
115 115 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) BI01010001010000000000000515BI0100001227 424.5 SQM
116 116 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. For the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001228 3.94 CUM
117 117 Boring providing & installing cast-in-situ single under reamed pile of specified dia and length below pile cap in cement concrete with mix M-20 of 20mm nominal size of grit to size to carry a safe working load not less than specified excluding the cost of steel reinforcement but including boring with pentonide solution and length of pile to embedded in the pile cap. 300 mm dia Piles (P1) BI01010001010000000000000515BI0100001229 156 RM
118 118 As in item 209 above but in R.C.C. Raft foundation and footing with stone ballast.(Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001230 6.21 CUM
119 119 As in item 209 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. BI01010001010000000000000515BI0100001231 0.486 CUM
120 120 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. BI01010001010000000000000515BI0100001232 5769.08 KG
121 121 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. BI01010001010000000000000515BI0100001233 636.468 SQM
122 122 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified BI01010001010000000000000515BI0100001234 487.313 SQM
123 123 Providing and laying of Interlocking Concrete Block Pavements having thicknes 80mm including leveling and dressing of surface to required level and slope spreading and moisting 30mm thick local sand on bend filling joints with local sand etc, for proper completion of the work as per drawing and Technical specification clause1504. BI01010001010000000000000515BI0100001235 500.025 SQM
124 124 PARKING SHED-II (2 Nos) BI01010001010000000000000515BI0100001236
125 125 Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. BI01010001010000000000000515BI0100001237 22.85 CUM
126 126 Filling of carted earth. BI01010001010000000000000515BI0100001238 43.994 CUM
127 127 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.(Including Royality) BI01010001010000000000000515BI0100001239 86.446 CUM
128 128 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete,including cost of form- work,in foundation and floors. BI01010001010000000000000515BI0100001240 48.092 CUM
129 129 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) BI01010001010000000000000515BI0100001241 424.5 SQM
130 130 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001242 7.88 CUM
131 131 Boring providing & installing cast-in-situ single under reamed pile of specified dia and length below pile cap in cement concrete with mix M-20 of 20mm nominal size of grit to size to carry a safe working load not less than specified excluding the cost of steel reinforcement but including boring with pentonide solution and length of pile to embedded in the pile cap. 300 mm dia Piles (P1) BI01010001010000000000000515BI0100001243 156 RM
132 132 As in item 222 above but in R.C.C. Raft foundation and footing with stone ballast.(Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001244 4.32 CUM
133 133 As in item 222 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. BI01010001010000000000000515BI0100001245 0.972 CUM
134 134 Mild steel or iron work of small sizes & sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for & welding, grinding & making holes as required fabrication of holes doors, chaukhats nosing. BI01010001010000000000000515BI0100001246 8341.01 KG
135 135 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. BI01010001010000000000000515BI0100001247 167.892 SQM
136 136 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified BI01010001010000000000000515BI0100001248 487.312 SQM
137 137 Providing and laying of Interlocking Concrete Block Pavements having thicknes 80mm including leveling and dressing of surface to required level and slope spreading and moisting 30mm thick local sand on bend filling joints with local sand etc, for proper completion of the work as per drawing and Technical specification clause1504. BI01010001010000000000000515BI0100001249 576.3 SQM
138 138 DEVELOPMENT WORK OF PARK (Road Side Development) BI01010001010000000000000515BI0100001250
139 139 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. BI01010001010000000000000515BI0100001251 365.72 CUM
140 140 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. BI01010001010000000000000515BI0100001252 81.02 CUM
141 141 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. BI01010001010000000000000515BI0100001253
142 142 As in item 232 above but in R.C.C. Raft foundation and footing with stone ballast.(Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001254 12 CUM
143 143 As in item 232 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001255 7.04 CUM
144 144 As in item no. 232 above but for slabs (Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001256 16.69 CUM
145 145 M-150 brick work in in super-structure above plinth level up to floor two level (up to two storeys) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand). BI01010001010000000000000515BI0100001257 219.94 CUM
146 146 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. BI01010001010000000000000515BI0100001258 33.56 QTL
147 147 25mm thick Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete with base of cement mortar. BI01010001010000000000000515BI0100001259 659.8 SQM
148 148 PARK DEVELOPMENT BI01010001010000000000000515BI0100001260
149 149 Concrete with 4 cm gauge stone ballast, coarse sand of 1.25 fm fineness modules and cement in the proportion 1:4:8 in foundation including supply of all materials, labour tools and plants etc. (PWD-281) BI01010001010000000000000515BI0100001261 228.2 Cum
150 150 P/L of 80mm thick Inter locking bricks in Pathway including all material etc. (SI No- Ch- 20 NS) BI01010001010000000000000515BI0100001262 1576.43 Sqm
151 151 LANDSCAPING OF PARK BI01010001010000000000000515BI0100001263
152 152 Supplying and stacking sludge at site including royalty and carriage up to 1 km (sludge measured in stacks will be reduced by 8% for payment). BI01010001010000000000000515BI0100001264 632.37 CUM
153 153 Carrigae of sludge upto 5 K.M. BI01010001010000000000000515BI0100001265 632.37 CUM
154 154 Supplying and stacking at site dump manure from approved source including carriage upto 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm BI01010001010000000000000515BI0100001266 105.4 CUM
155 155 Carrigae of manure upto 5 K.M. BI01010001010000000000000515BI0100001267 105.4 CUM
156 156 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge. BI01010001010000000000000515BI0100001268 737.77 CUM
157 157 Spreading of sludge, dump manure or/and good earth in required thickness (cost of sludge dump manure or/and good earth to be paid separately). BI01010001010000000000000515BI0100001269 737.77 CUM
158 158 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%), flooding with water, dressing, including removal of rubbish and surplus earth, if any with all leads and lifts ( cost of manure, sludge or extra good earth if needed to be paid for separately). Holes 0.9 m dia. and 0.90 m deep. BI01010001010000000000000515BI0100001270 350 NO.
159 159 Plantation of trees. (Decorative Plants) BI01010001010000000000000515BI0100001271 350 EACH
160 160 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). With grass Turf. BI01010001010000000000000515BI0100001272 2107.9 Sqm
161 161 PAVILION (3 NOS) BI01010001010000000000000515BI0100001273
162 162 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. BI01010001010000000000000515BI0100001274 14.85 CUM
163 163 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. BI01010001010000000000000515BI0100001275 3.681 CUM
164 164 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. BI01010001010000000000000515BI0100001276 2.667 CUM
165 165 Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) BI01010001010000000000000515BI0100001277 17.787 SQM
166 166 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. BI01010001010000000000000515BI0100001278
167 167 As in item no. 256 above but for slabs (Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001279 6.564 CUM
168 168 As in item no. 256 above but for Beam (Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001280 3.651 CUM
169 169 As in item no. 256 above but for Footing (Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001281 2.43 CUM
170 170 As in item no. 256 above but for Column (Using 1:1.5:3 Mix concrete) BI01010001010000000000000515BI0100001282 2.317 CUM
171 171 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. BI01010001010000000000000515BI0100001283 2.841 CUM
172 172 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. BI01010001010000000000000515BI0100001284 13.563 QTL
173 173 20mm Thick cement plaster in two coats, backing coat 17mm and finishing coat 3mm thick on rough side of single or half brick wall for interior plastering up to floor two level including arises, internal rounded angle chamfers and or rounded angle not exceeding 30mm in grith and finished even and smooth. (i) 1 cement: 3 coarse sand BI01010001010000000000000515BI0100001285 52.5 SQM
174 174 Laying of 25mm thick KOTA stone of size 45x45 cm and above flooring over previously prepared base with 2 cm thick 1:3 cement and sand mortar including filling of joints with cement mixed with pigment required for matching the shade of floor as per direction of E/I including cutting polishing with wax polish including supply of all materials T &P etc. required for proper completion of the work. BI01010001010000000000000515BI0100001286 25.887 SQM
175 175 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) BI01010001010000000000000515BI0100001287 146.301 SQM
176 176 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. BI01010001010000000000000515BI0100001288 146.301 SQM
177 177 Cartage earth filling in the campus with watering ramming and proper compaction of earth. BI01010001010000000000000515BI0100001289 3126.74 CUM
178 178 GST Extra as applicable BI01010001010000000000000515BI0100001290
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail