Provision Of Addition / Alteration Cum Special Repair To Jcos/Or Marriedd Accommodation At Ncc Gorakhpur

Tender Notice

28210978
Corrigendum : Provision Of Addition / Alteration Cum Special Repair To Jcos/Or Marriedd Accommodation At Ncc Gorakhpur
Indian
Uttar Pradesh
14-07-2021
21-07-2021
23-07-2021

Tender Details

Provn Of Addition / Alteration Cum Special Repair To Jcos / Or Marriedd Accommodation At Ncc Gorakhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jul-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-07-2021

Key Value

Document Fees
INR 1000 /-
EMD
INR 128500.00 /-
Tender Value
INR 69 Lakhs /-

BOQ Items

Name of Work : PROVN OF ADDITION / ALTERATION CUM SPECIAL REPAIR TO JCOs/OR MARRIEDD ACCOMMODATION AT NCC GORAKHPUR
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil. 1 10.8 PER CUBIC METRE
2 2 Returning filling in foundation/trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick complete. 2 6 PER CUBIC METRE
3 3 Removal of excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. 3 4.8 PER CUBIC METRE
4 4 Material and labour for anti-termite treatment (post construction) along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.\n 4 130 PER RUNNING METRE
5 5 Material and labour for anti-termite treatment (post construction) of soil under existing floors using chemical emulsion @ one liter per hole, 300 mm apart including drilling holes and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors etc complete all as specified and directed.\n 5 200 PER SQUARE METRE
6 6 Supply and lay sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and consolidations, complete all as specified and directed by Garrison Engineer / Engr-in-Charge.\nNote :- Punned thickness will be measured and paid. 6 4 PER CUBIC \nMETRE
7 7 Material and labour Provide plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in hold fast etc complete all as specified and directed.\n 7 0.5 PER CUBIC METRE
8 8 Material and labour Provide plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed.\n 8 0.7 PER CUBIC METRE
9 9 Material and labour Provide plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.\n 9 1 PER CUBIC METRE
10 10 Material and labour providng precast cement concrete louvres and jallies, 25 mm thick (measured solid) including all mouldingsbut excluding frame of PCC 1:2:4 type B-0 using 12.5 mm graded aggregate set in cement mortar 1:4 complete all as specified and directed. 10 10 PER SQUARE METRE
11 11 Supply only liquid water proofing compound complete all as specified and directed. 11 25 PER LITRE
12 12 Material and labour brick work with sub-class 'B' bricks (old size) straight or curved on plan exceeding 6 metre mean radius, built in cement and sand mortar (1:6) complete all as specified and directed. 12 1.5 PER \nCUBIC \nMETRE
13 13 Supply and laying in trenches dry well burnt locally available sub class 'B' bricks best class locally available laid over sand cushioning for protection of cable complete all as specified and directed by Garrison Engineer / Engr-in-Charge. 13 0.36 PER THOUSAND NUMBERS
14 14 Material and labour Second class hard wood (SAL) Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in opening complete all as specified and directed.. 14 0.5 PER \nCUBIC \nMETRE
15 15 Taking down wooden Windows/Doors chowkats or frames exc 1.5 sqm but not exc 4 sqm each (without taking off shutters from the frames) including making good for fixing new frame complete all as specified and directed.\nNote :- (i) Old shutters, frame guard bars etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment.\n(ii) Quoted rate shall deem to be included cost of making good jambs portion. 15 56 EACH
16 16 Taking down wooden windows/ventilator/chowkhats or frames with shutter not exceeding 1.5 sqm each (without taking off shutters from frame) including maxing good for fixing new frame complete all as specified and directed.\nNote :- (i) Old shutters, frame guard bars etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment.\n(ii) Quoted rate shall deem to be included cost of making good jambs portion for fixing new frame.\n 16 56 EACH
17 17 Taking down shutters with hinge of any description exceeding 1 square metre and not exceeding 2 square metre each. \nNote :- (i) Old shutters shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment. 17 64 PER LEAF
18 18 Supply and fix 35mm thick second class hard wood rail and style factory made plain framed, panelled shutter (two panel) with lock rail land panel of 9mm thick BWP commercial ply wood. The size of rail and stile as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated fixed of frame. \nNote :-Builder hardware shall be measured and paid for separately under respective item of this schedule at supply only. 18 140 PER \nSQUARE \nMETRE
19 19 Supply and fix 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc including teak wood beading on all edges.\nNote :- Thickness of beading for hinge sides shall be 25 mm and on other three edges 6mm thick.\n(ii) Builder hardware shall be measured and paid for separately at supply only. 19 80 PER \nSQUARE \nMETRE
20 20 Supply and fix 30 mm thick factory made solid panel prelam PVC Flush door shutter consisting frame made out of mild steel tube of 19 gauge (minimum) thickness and minimum size of 40 mmX20 mm for stiles as well as top, lock and bottom rails, mild steel frame shall be have a coat of metal primer of approved make or as per manufacturer instruction mild steel frame shall be covered with heat mould prelem 'C' channel made from 5 mm (minimum) thick PVC sheet of density 600 kg/cum manufacturer by an ISO : 90000 certify company, 110mm (minimum) width forming stiles in which 100 mm (minimum) should be flat & 5 mm should be tappered and 5 mm thick, 135 mm (minimum) wide PVC (rigid) sheet for top rail and bottom rail in which 125 mm should be flat & 5 mm tapper on either sides of panel, also for lock 145 mm (minimum) sheet, 125 mm should be flat and 5mm taper on either sides. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior sides of 'C' channel using PVC solvent cement adnesive, panneling of 10 mm thick prelam PVC sheet to be fitted in the frame/sealed to the stiles and rails with 30mm vide, 5mm (minimum) thick PVC sheet beading on either side complete all as manufacturer instruction and as shown on drawing No.CWE/BAM/TD-40 Sheet No. 1/3 .\nNote :- Builder hardware shall be measured and paid for separately under respective item of this schedule of works at supply only rates . 20 50 PER SQUARE METRE
21 21 Supply and fix 30mm thick factory made prelam wire mesh solid PVC Door Shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm stiles and 15mm x 15mm for top, lock & bottom rails. M.S. frame shall have a coat of matel primer of approval make and manufactured 19mm x 19mm M.S square tubes shall be covered with heat moulded plain sheet 'C' Channel made from 5mm (+0.25) thick PVC sheet of density 600kgs/cbm manufactured by an ISO-9001-2008 certified company of size 30mm thickness. 90mm width out which 75mm shall flat and 15mm shall be bent in 90º angle on either side forming stiles, one of the 90º bend edge is cut from stiles as well as rails to nail from inner of the door to hide wire mesh fixing a steel screws. 5mm(+0.25) thick 115mm wide PVC sheet out of which 100mm shall be flat and 15mm shall be bent in 90º on the inner side to from top and bottom rail and 130mm wide sheet out of 100mm shall be flat and 15mm shall be bent in 90º on both side to from lock rail an additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of 'C' channel using PVC solvent cement adhesive. Panel will be stainless steel wire mess with not less than 0.36mm nominal dia of wire and 1.40mm average width of aperture (Note : Grade of steel to be used in manufacturing the wire cloth shall be S-304) to be fitted inside area of stiles and rails. the wire mesh in top, bottom & lock railed is sealed with 15mm x 15mm tube with steel screw of size 13/6mm. 10mm (5mm x 2 nos) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail door to be fixed to frame with 3 nos. M.S Powder coated butt hinges size 100mm*25mm*2mm and 32mm long steel screw drilled suitable to pass through both the walls of the M.S tube. Other hardware should be fixed with 19mm x 6mm size steel screws etc. Complete as per manufacturer's specification & shown on drawing No CWE/BAM/TD Sheet No 3/3.\nNote :- (i) Frame shall be measured and paid for separately under respective item of this schedule of works.\n(ii) Quoted rate shall be deemed to inclusive of Aluminimum anodised Builders hardware shown on drawings as "Schedule of iron mongry". 21 45 PER SQUARE METRE
22 22 Supply and fix Factory made prelam PVC door frame " of size 100x45mm ((minimum) with a wall minimum thickness of 5 mm made out of extruded PVC sheet of density 600 kg/cum manufactured by an ISO-9000 certfied company and by joining 3 number heat bent PVC sheet section, the inside section of minimum size 90x30mm shall be made from prelam coloured PVC sheet of 5mm (minimum) thickness, the inside section will be covered by sticking two long brackets of 15 mm x15mm mild steel square tube, the two vehicle door frame made of 5mm thick plain colour PVC sheet reinforced with mild steel square tube the vertical door frame are to be reinforced with (minimum) 40mmx20mm mild steel tube of 19 gauge (minimum) through out the frame. the door frame shall be fixed to wall using 8/100mm long mild steel screws through the frame by using and or fasterners. A minimum of 04 number of screw to be provided for each vertical member and two number for horizontal members etc. complete as per manufacturers specifications and as shown on drawing No.CWE/BAM/TD-40 Sheet No.1/3 & 2/3.\nNote :- Gap in between frame & wall/lintel shall be filled properly with suitable materials as per manufacturer's instruction to avoid crackes after wards.\n(ii) Colour & design shall be as approved by GE. 22 160 PER RUNNING METRE
23 23 Supply and fix 18mm thick celuka PVC sheet minimum 600 kg/cum density grade 1 quality of both side pre laminated fixed with screws, solvent cement/adhesive as per manufacturer instructions and supporting the shelf / partition and shall provide with PVC runners in three sides of shelf of size 18 mm x 18mm as per required length. The front side of the edges visible in the front of the shelf / partition to be elgelipped by 18 mm width 1 mm thick complete as per specifications and as directed by the Garrison Engineer. \nNote:- (i) Quoted rates deem to be include fixing of cup board on wall with appropriate raw plug/dash through fastener (hammer type) as specified by manufacturer instructions.\n(ii) Fabrication and installation of cup board to be carried out by authorized vendor of manufacturer only.\n 23 20 PER SQUARE METRE
24 24 Supply and fix 18mm thick celuka PVC sheet minimum 600 kg/cum density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make cupboard sides top and bottom and shelves inside the cup board complete as per specifications and as directed by the Garrison Engineer. \nNote:- (i) Quoted rates deem to be include fixing of cup board on wall with appropriate raw plug/dash through fastener (hammer type) as specified by manufacturer instructions.\n(ii) Fabrication and installation of cup board to be carried out by authorized vendor of manufacturer only.\n 24 20 PER SQUARE METRE
25 25 Supply and fix in repair 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination,and other side balancing white lamination 4mm thick teak wood lipping on all edges and fixed to wooden frame with screws (for pelmet boxex, cupboard shutters etc) complete all as specified and directed.\n 25 20 PER SQUARE METRE
26 26 Supply and fix Iind class hard wood Small fittings such as brackets of any type, latch and hinge blocks shaped door and window stops and the like, including all necessary labours; articles n exc 200 cu.cm each complete all as specified and directed. 26 50 EACH
27 27 Supply only Aluminium, anodised, barrel tower bolts of extruded section size 200 mm long complete. 27 16 EACH
28 28 Supply only Aluminium, anodised, barrel tower bolts of extruded section size 150 mm long complete. 28 64 EACH
29 29 Supply only Aluminium, anodised, handle cast type size 125 mm long complete. 29 64 EACH
30 30 Supply only Aluminium, anodised, handle cast type size 150 mm long complete. 30 128 EACH
31 31 Supply and fix continuous (piano) hinges, mild steel, bright finish or electrogalvanised width of flap (when open) is 30 mm complete all as specified and directed. 31 19 PER RUNNING METRE
32 32 Supply and fix 100 mm long stainless steel handles for kitchen cabinet shutter complete all as specified and directed. 32 34 EACH
33 33 Supply and fix 75 mm long stainless steel butt hinges L / Z type openable at 110 degree complete all as specified and directed. 33 34 EACH
34 34 Supply only 100mm long mild steel butt hinges cold rolled complete. 34 192 EACH
35 35 Supply only 250mm length of bolt aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. 35 80 EACH
36 36 Supply and fix Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate, 75 mm size complete all as specified and directed. 36 64 EACH
37 37 Supply and fix in repair coloured plastic coated aluminimum curtain rod (dropery rod) 20mm dia curtain single rod with bracket fixed in brick/concrete wall and decorative nobs on each end of curtain rod fancy type complete all as specified and directed.\n 37 160 PER RUNNING METRE
38 38 Supply and fix in repair fancy type bracket fixed in brick/concrete wall and fancy type decorative nobs on each end suitable for 20 mm dia curtain rod complete all as specified and directed.\n 38 60 EACH PAIR
39 39 Supply and fix stainless steel (S-306 grade) wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed in as repairs and fixed with stainless steel wire stapples to frame complete all as specified and directed.\n. 39 100 PER SQUARE METRE
40 40 Supply and fix in repair stainless steel (S-306 grade) wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed in as repairs and fixed with stainless steel wire stapples to frame complete all as specified and directed.\n. 40 30 PER SQUARE METRE
41 41 Supply and fix flat iron for hold fast etc conforming to FE-290 Gde-E-165 complete all as specified and directed. 41 10 PER KILOGRAM
42 42 Mild steel framed work such as grills, grating etc with ends of bars shoulded, framed guard bars and similar work conforming to Fe-290 Gde E-165 fixed to frame with screws complete all as specified and directed. 42 730 PER KILOGRAM
43 43 Supply and fix steel window with side hung shutter with box type hinges, steel peg stay, lugs, steel handles, without glazing bars complete including one shop coat of red oxide primer complete all as specified and directed. 43 110 PER SQUARE METRE
44 44 Supply and fix steel window with side hung shutter with box type hinges, steel peg stay, lugs, steel handles, with glazing bars complete including one shop coat of red oxide primer complete all as specified and directed. 44 110 PER SQUARE METRE
45 45 Supply and fix steel ventilator with top hung shutter including hinges, steel peg stay, lugs, steel handles, complete including one shop coat of red oxide primer complete all as specified and directed. 45 8 PER SQUARE METRE
46 46 Material and labour for treating the sunken floor with preparing surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surface with funny bags to remove all loose dirt etc, applying consisting of the following operation:-\n(a) 10mm thick plaster/screed bed in cement mortar 1:3 complete mixed with liquid water proofing compound as per manufactures instructions complete all as specified & directed (Note - WPC shall be measured and paid separately).\n(b) Cleaning floor surface by wire brush brooming & removing dust & shall be painted with a coat of bituminous primer conforming to IS : 3384-1986 @ 0.3 Ltr per Sqm uniformily complete all as specified & directed. \n(c) After primer the entire roof surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to 702-1988 @ 1.2 Kg per sqm over primer.\n(d) Over hot bitumen laying polymeric water proofing membrance conisting of 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm over entire area laid with 100mm side lap/end lap on prepared surfaces as per manufacture's technical instruction & sealed complete all as specified & directed.\n(e) Again the entire floor surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to IS 702 @ 1.2 Kg per sqm. 46 33 PER SQUARE METRE
47 47 Material and labour cleaning the roof surface (padding) from dust/dirt and provide water proofing treatment using APP based polymeric water proofing membrance 3 mm thick conisting of reinforced with polyster non wove fabric (weight shall not be less than 150 gms/sqm or as per IS ) 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm with preparing surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surface with funny bags to remove all loose dirt etc, applying consisting of the following operation:-\n(a) 10mm thick plaster/screed bed in cement mortar 1:3 complete mixed with liquid water proofing compound as per manufactures instructions when concrete is still green (PCC padding) complete all as specified & directed (Note - WPC shall be measured and paid separately).\n(b) After the plaster is fully dried cleaning floor surface by wire brush brooming & removing dust & shall be painted with a coat of bituminous primer conforming to IS : 3384-1986 @ 0.3 Ltr per Sqm uniformily complete all as specified & directed. \n(c) After primer the entire roof surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to 702-1988 @ 1.2 Kg per sqm over primer.\n(d) Over hot bitumen laying polymeric water proofing membrance 3 mm thick conisting of reinforced with polyster non wove fabric (weight shall not be less than 150 gms/sqm or as per IS ) 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm over entire area laid with 100mm side lap/150 mm end lap on prepared surfaces and under strict supervision of manufacturer’s technical representative & sealed complete all as specified & directed.\n(e) Cement concrete tiles 20cm x 20cmx20mm thick machine pressed, set jointed with grey cement and no pigment pointed in neat cement slurry over roof slab cut and polished including 20 mm thick screed bed in cement mortar (1:4) mixed with water proofing compound as per manufacturer instructions or @ 100 ml per bag of cement. (Liquid Water proofing compound shall be measured and paid in respective item of this schedule at supply only). \n(f) Water proofing treatment shall be carried out through authorized applicators only. \n(g) The work shall be carried out strictly as per manufacturer’s instructions. 47 600 PER SQUARE METRE
48 48 Material and labour 25mm thick plain cement concrete type B0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) as levelling course on existing concrete surface over a coat of cement slurry as specified in MES SSR Part I complete all as specified and directed.\nNote :- Quoted rate shall deem to be included cost of cement slurry as specified in Para 13.32.7 of MES SSR Part I. 48 600 PER SQUARE METRE
49 49 Material and labour 50mm thick plain cement concrete 1:2:4 type B-1, (using 20mm graded crushed stone aggregate), laid in bays, surface finished even and smooth without using extra cement complete all as specified and directed. \nNote :- Glass dividing strip shall be measured and paid for separetely under respective item of this schedule. 49 100 PER SQUARE METRE
50 50 Material and labour 40mm thick plain cement concrete, type B-1, 1:2:4 (using 20mm graded crushed stone aggregate, laid in bays, over a coat of cement slurry as specified in MES SSR Part I surface finished even a smooth with using extra cement complete all as specified and directed. \nNote :- (i) Glass dividing strip shall be measured and paid for separetely under respective item of this schedule..\n(ii) Quoted rate shall deem to be included cost of cement slurry as specified in Para 13.32.7 of MES SSR Part I. 50 100 PER SQUARE METRE
51 51 Supply only 3mm thick 38mm width glass dividing strips, complete all as specified and directed. 51 15 PER RUNNING METRE
52 52 Material and labour roughening surfaces of old concrete fllor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.\n 52 1103 PER SQUARE METRE
53 53 Material and labour 20-25mm thick machine cut kota stone slab size (550x550mm) in flooring mirror polished, set and jointed in neat cement slurry, pointed with grey cement slurry mixed with pigment to match the shade of the slab complete including rubbing and mirror polishing over and including 20mm thick cement and sand mortar (1:6) bedding layer including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and cement slurry shall be applied over existing concrete surface for bonding with new one as specified in MES SSR Part-I . \nNote:- (i) Quoted rate shall deem to included cost of bedding layer, cement slurry, and roughening surfaces of old concrete floor.\n 53 140 PER SQUARE METRE
54 54 Material and labour 20-25mm thick machine cut kota stone slab in skirting mirror polished, set and jointed in neat cement slurry, pointed with grey cement slurry mixed with pigment to match the shade of the slab complete including rubbing and mirror polishing over and including 15mm thick cement and sand mortar (1:4) as backing coat complete all as specified and directed. \nNote:- (i) Quoted rate shall deem to included cost of backing coat. 54 12 PER SQUARE METRE
55 55 Material and labour rounding to edges of stone slabs one edge such as in steps, cooking platform, and other similar locations complete all as specified and directed. \n 55 584 PER RUNNING METRE
56 56 Material and labour 300 mmX200mm X 7-8 mm thick glazed ceramic coloured tiles in vertical surfaces such as skirting, dado, etc set and jointed in neat cement slurry and pointed in white or colured cement to match over & including 10 mm thick backing coat in cement and sand mortar (1:4) complete all as specified and directed.\nNote :- Quoted rate shall deem to be included cost of backing coat. 56 432 PER SQUARE METRE
57 57 Material and labour joint free non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 Square metre and not exceeding 0.18 Square metre (minimum size 400 x 400 mm) in floor, set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement and sand mortar (1:6) complete all as specified and directed.\nNote :- Quoted rate shall deem to be included cost of screed bed. 57 670 PER SQUARE METRE
58 58 Material and labour joint free non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 Square metre and not exceeding 0.18 Square metre in skirting, set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick backing coat in cement and sand mortar (1:4) complete all as specified and directed.\nNote :- Quoted rate shall deem to be included cost of backing coat. 58 115 PER SQUARE METRE
59 59 Material and labour granite (telephone black) 18 to 20mm thick machine cut, (table rubbed and polished) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including15mm thick screed bed or bedding layer in cement mortar (1:4) over over existing RCC slab work in cooking platform complete all as specified and directed.\nNote :- (i) Quoted rate shall deem to be inlcude cost of cement bedding.\n(ii) Exposed edge of slab shall be rounded, bevelled, chamfered and cost of same be included in the quoted rate.\n(iii) Slab shall be single piece in width and length of platform. 59 45 PER SQUARE METRE
60 60 Material and labour granite (telephone black) 18 to 20mm thick machine cut, (table rubbed and polished) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over and including15mm thick backing coat in cement mortar (1:4) over for skirting complete all as specified and directed.\nNote :- (i) Quoted rate shall deem to be inlcude cost of cement bedding.\n(ii) Exposed edge of slab shall be rounded, bevelled, chamfered and cost of same be included in the quoted rate.\n 60 4.67 PER SQUARE METRE
61 61 Dismantling, floor, hearth or wall tiling including cement mortar bedding etc including preparation of surface to received new floor finish/wall tiles and removing rubbish outside MOD land complete all as specified and directed. 61 560 PER SQUARE METRE
62 62 Material and labour 5 mm thick rendering in cement and sand mortar (1:3) on ceiling surface finished even and fair without using extra cement complete all as specified and directed. 62 65 PER SQUARE METRE
63 63 Material and labour 15mm thick rendering in cement and sand mortar (1:6) on fair faces of brick work, surfaces finished even and fair without using extra cement, complete all as specified and directed.\n 63 2000 PER SQUARE METRE
64 64 Material and labour 15mm thick rendering in cement and sand mortar (1:4) on fair faces of brick work, surfaces finished even and fair without using extra cement mixed with liquid water proofing compound as per manufacturerer instructions complete all as specified and directed.\nNote : Liquid water proofing compound shall be measured and paid in respective item of this schedule supply only rate. 64 1335 PER SQUARE METRE
65 65 Taking down cement plaster on brick walls, etc, including raking out joints, hacking for key, scrubbing down with water etc & prepare surface to receive new plaster complete all as specified and directed. 65 3400 PER SQUARE METRE
66 66 Complete removal of existing treatment from wall and applying 1 mm thick wall care putty including preparing surfaces of wall and applying two coat of oil emulsion distemper over a coat of primer complete all as specified and directed. 66 780 PER SQUARE METRE
67 67 Complete removal of existing treatment from wall including preparing surfaces of wall and applying two coat of cement based paint over a coat of primer complete all as specified and directed. 67 466 PER SQUARE METRE
68 68 Preparing new plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed. 68 1335 PER SQUARE METRE
69 69 Preparing new plastered surfaces of wall and applying two coat of oil emulsion distemper over a coat of primer over a coat of 1 mm thick wall care putty complete all as specified and directed. 69 2000 PER SQUARE METRE
70 70 Preparing new plastered surfaces of ceiling and applying three coat of white wash complete all as specified and directed. 70 65 PER SQUARE METRE
71 71 Preparing old surfaces of ceiling and applying two coat of white wash complete all as specified and directed. 71 40 PER SQUARE METRE
72 72 Supply and fix 3mm thick sheet glass, ordinary quality and glazing with oil putty and clips in square not exceeding 0.5 square metre each pane complete all as specified and directed. 72 100 PER SQUARE METRE
73 73 Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete all as specified and directed. 73 10 PER SQUARE METRE
74 74 Preparing new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 74 130 PER SQUARE METRE
75 75 Preparing old treated steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 75 50 PER SQUARE METRE
76 76 Material and labour preparing new surfaces of wood or wood based materials of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 76 150 PER SQUARE METRE
77 77 Material and labour preparing old treated surfaces of wood or wood based materials of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 77 50 PER SQUARE METRE
78 78 Material and labour preparing surfaces of steel and iron work of any description and girth not otherwise described and treated with tar or coltar (treating end of post etc area tarred exc 0.10 Sqm but n exc 0.5 Sqm each. 78 0.5 PER HUNDRED NUMBERS
79 79 Material and labour preparing surfaces of steel and iron work of any description and girth not otherwise described and treated with tar or coltar (treating end of post etc area tarred but n exc 0.10 Sqm each. 79 1.2 PER HUNDRED NUMBERS
80 80 Material and labour 15mm dia Tubes, ‘medium grade’ galvanised, with all fitting concealed or fixed on walls and ceilings or laid in floors etc and testing complete all as specified and directed.\nNote :- Quoted rate shall deem to be included cost of cutting chasses in wall for concealed pipe. 80 150 PER RUNNING METRE
81 81 Material and labour 20mm dia Tubes, ‘medium grade’ galvanised, with all fitting concealed or fixed on walls and ceilings etc and testing complete all as specified and directed.\nNote :- Quoted rate shall deem to be included cost of cutting chasses in wall for concealed pipe. 81 160 PER RUNNING METRE
82 82 Material and labour 40mm dia Tubes, ‘light grade’ galvanised, fixed on sunken floor as spout including taking out existing pipe complete all as specified and directed.\nNote :- Quoted rate shall deem to be included cost of cutting of holes. 82 16 PER RUNNING METRE
83 83 Supply and fix 50mm bore steel tubing galvanised “Light Grade” in trenches/poles, under floors, roads, along poles for protection of cables, including sealing ends all as specified complete all as specified and directed by Engineer-in-Charge.\nNote :- Clamps for fixing pipe on poles shall be included the unit rate quoted by contractor. 83 3 PER RUNNING METRE
84 84 Taking down 15mm bore GI tubing and connection fixture etc from wall complete. \nNote :- Old retrived pipes, fittings, taps, valve etc shall be contractor property and necessary amount as schedule of credit shall be deducted from the contractor due payment. 84 150 PER RUNNING METRE
85 85 Taking down 20mm bore GI tubing and connection fixture etc from wall complete.\nNote :- Old retrieved pipes, fittings, taps, valve etc shall be contractor property and necessary amount as schedule of credit shall be deducted from the contractor due payment. 85 160 PER RUNNING METRE
86 86 Hoisting and fixing Rotational moulded polyethylene cylindrical vertical with closed top water storage tank double layered, 500 Ltr capacity, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection including ball brass valves high pressure of with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed 20mm dia polythene floated fly nut, tank nipple, 2 Nos 20mm dia union, wash out pipe etc complete all as specified and directed.\n 86 16 EACH JOB
87 87 Supply and fix cast iron floor trap, 75mm outlet dia, plain with stainless steel grating including jointing with run lead to connection pipe and bedded in PCC 1:2:4 type B-1(20 mm graded stone aggregate) complete all as specified and directed.\n 87 8 EACH
88 88 Supply and fix cast iron nahani trap, 75mm outlet dia, plain with stainless steel grating including jointing with run lead to connection pipe and bedded in PCC 1:2:4 type B-1(20 mm graded stone aggregate) complete all as specified and directed.\n 88 8 EACH
89 89 Supply and fix 100 mm outlet dia cast iron bends of any radius, with duck foot heal rest including jointing with run lead to complete all as specified and directed.\n 89 16 EACH
90 90 Supply and fix 75 mm outlet dia cast iron bends of any radius, with duck foot heal rest including jointing with run lead to complete all as specified and directed.\n 90 16 EACH
91 91 Supply and fix cast iron branch pieces, 100 mm dia, double, (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors complete all as specified and directed.\n 91 8 EACH
92 92 Supply and fix PVC (SWR) bends 110 mm dia, of any radius complete all as specified and directed.\n 92 16 EACH
93 93 Supply and fix PVC (SWR) vent cowls 110 mm dia, complete all as specified and directed.\n 93 8 EACH
94 94 Supply and fix 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.\n. \nNote :- Fittings suction Bend, tee and cowl shall be measured and paid for separtely as supply only. 94 110 PER RUNNING METRE
95 95 Supply and fix 100mm bore cast iron centrifugal spun pipe soil waste, and vent rain water pipe single socketed in any length with lead joints laid in walls complete all as specified and directed.\nNote :- (i) Fitting such as bend, tee and cowl shall be measured and paid for separtely. \n 95 40 PER RUNNING METRE
96 96 Supply and fix 75 mm bore cast iron centrifugal spun pipe soil waste, and vent rain water pipe single socketed in any length with cement joints laid in walls complete all as specified and directed.\nNote :- (i) Fitting such as bend, tee and cowl shall be measured and paid for separtely. 96 30 PER RUNNING METRE
97 97 Supply and fix in repairs 15mm bore stop valve cast copper alloy, fancy type, chromium plated screwed down, high pressure with crutch or butterfly handle screwed both ends (externally threaded) for iron pipe or for unions and fixed complete all as specified and directed. 97 32 EACH
98 98 Supply and fix in repairs Bib tap long body with wall flange, fancy type, chromium plated, brass, screwd for 15mm bore iron pipe with capstain head complete all as specified and directed.\nNote :- Bib tap cat part No F200011 of Hindware or equivalent model of make as specified in Appendix 'B' to Particular specifications. 98 80 EACH
99 99 Supply and fix in repairs perforated chromium plated brass shower rose with swivel joints, heavy pattern 125mm dia rim with 150mm long brass chromium plated extension rod (fancy type) suitable for 15mm bore inlet complete all as specified and directed.\nNote :- Shower rose cat part No F160051 of Hindware or equivalent model of make as specified in Appendix 'B' to Particular specifications. 99 16 EACH
100 100 Supply and fix in repairs PVC braided connection 450mm long with two numbers check nut washers etc complete all as specified and directed. 100 32 EACH
101 101 Supply and fix in repairs 125 mm dia chromimum plated grating doom with waste hole complete all as specified and directed. 101 16 EACH
102 102 Supply and fix in repair Vitreous china squatting pan (Orissa pattern) water closed (white) of minimum size 580x440mm with integral foot rests, cast iron 'P' or 'S' trap, connection to trap and flushing pipe, antisyphonage pipe etc with and includng provision of PCC (1:5:10) type E2 in filling, PVC low level flushing cistern of 10 liter capacity, 32mm dia PVC flush pipe connected to water closet with inlet, PVC braided connection and angular stop cock (valve) with flange etc complete all as specified in particular specifications. 102 16 EACH JOB
103 103 Supply and fix in repair vitreous china wash hand basin (white), flat back of minimum size 550mm x 400mm with and including a pair of cast iron brackets embedded in PCC (1:3:6) type C1 blocks of size 10x 7.5x15cm, 32 mm dia PVC waste pipe of suitable length, 32mm bore chromium plated brass waste fitting, PVC braided connection, CP coupling, pillar tap CP long neck, CP angular valve with flange, (for 15 mm bore pipe) CP bottle trap etc complete all as specified in particular specifications. 103 16 EACH JOB
104 104 Supply and fix in repair 600mm long between flanges brass chromium plated towel rack with brackets fixed to wall with chromium plated brass screws complete all as specified in particular specifications.\nNote :- (i) Towel rack cat part No F5002101 of Cera or equivalent model of make as specified in Appendix 'B' to Particular specifications 104 16 EACH
105 105 Supply and fix in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 120mm (minimum) wide with chromium plated brass bracket guard and railing 600mm long complete all as specified and directed. 105 16 EACH
106 106 Supply and fix in repair kitchen plate rack made out 1 mm thick stainless steel sheet, SS screws round pipe of size 600mm x900mmx250mm including fixing with rawal plug and screws complete all as specified and directed.\n 106 16 EACH
107 107 Supply and fix in repair 600mmx450mm and 6mm thick bevelled edge looking mirror selected quality mounted on 6mm thick backing comercial plywood fixed with CP plug with chromium plated brass screws and cup washer fixed on wall complete all as specified and directed. 107 16 EACH
108 108 S&F in repair stainless steel kitchen sink matt finish with drainage board made of 1.00mm (minimum) thick stainless steel (Grade S-304) sheet with plug washer including bedding in cement mortar to wall or including fixing cantilever bracket etc connecting union to pipe overall (minimum ) overall size 940mm x 455mm with bowl depth (minimum) 203 mm complete including waste coupling CP and waste pipe suitable for sink all as specified in particular specifications.\nNote :- (i) Stainless steel kitchen sink cat part No B4512101 of Cera or equivalent model of make as specified in Appendix 'B' to Particular specifications 108 16 EACH JOB
109 109 Taking down carefully existing aluminium/copper batten concealed point, wiring for light/fan/socket/bell or power point excluding all fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc complete all as specified and directed.\nNote :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fitting and fixture as directed and deposited in MES store yard of GE (AF) Bamrauli. Receipt shall be obtained before claiming the payment of new fittings.\n(ii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.\n(iii) Old unserviceable wiring fittings, fixture, etc other than light fittings shall be contractor's property and necessary amount as per schedule of credit from contractor due payment.\n 109 448 PER POINT
110 110 Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed multistranded copper conductor FRLS Cables as earth wire connected to earth dolly incl metal junction box, grid plate and base plate suitable for modular switches, sockets and switch for one light point controlled by one switch.\nNote : (i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit.\n(ii) Switches, sockets, etc shall be measured and paid for separately. 110 202 PER POINT
111 111 Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed multistranded copper conductor FRLS Cables as earth wire connected to earth dolly incl metal junction box, grid plate and base plate suitable for modular switches, sockets and switch for one light point controlled by two, two way switches.\nNote : (i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit.\n(ii) Switches, sockets, etc shall be measured and paid for separately. 111 6 PER POINT
112 112 Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed multistranded copper conductor FRLS Cables as earth wire connected to earth dolly incl metal junction box, grid plate and base plate suitable for modular switches, sockets and switch for one call bell point controlled by one switch.\nNote : (i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit.\n(ii) Switches, sockets, etc shall be measured and paid for separately. 112 16 PER POINT
113 113 Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed multistranded copper conductor FRLS Cables as earth wire connected to earth dolly incl metal junction box, grid plate and base plate suitable for modular switches, sockets and switch for one fan/exhaust fan point controlled by one switch and regulator.\nNote : (i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit.\n(ii) Switches, sockets, etc shall be measured and paid for separately. 113 64 PER POINT
114 114 Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on independent board controller by one switch 5/6 Amps.\nNote :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule.\n(ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box.\n(iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.\n(iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit.\n(v) Switches, sockets, etc shall be measured and paid for separately. 114 64 PER POINT
115 115 Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on same board with other switches 5/6 Amps.\nNote :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule.\n(ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box.\n(iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.\n(iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit.\n(v) Switches, sockets, etc shall be measured and paid for separately. 115 48 PER POINT
116 116 Point wiring with PVC insulated, unsheathed single core, nominal area 4 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 4 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on independent board controller by one switch 15/16 Amps.\nNote :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule.\n(ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box.\n(iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.\n(iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit.\n(v) Switches, sockets, etc shall be measured and paid for separately. 116 48 PER POINT
117 117 Supply and fix switch piano flush 5 Amp single pole one way(one module) complete all as specified and directed. 117 314 EACH
118 118 Supply and fix switch piano flush 5 Amp single pole two way complete all as specified and directed. 118 12 EACH
119 119 Supply and fix switch socket combination 2 in 1 flush type 6 Amp 3 pin complete all as specified and directed. 119 64 EACH
120 120 Supply and fix socket outlet 2 in 1 flush type 5 Amp 3 pin complete all as specified and directed. 120 48 EACH
121 121 Supply and fix switch socket combination 2 in 1 flush type 5 and 15 Amp 3 pin complete all as specified and directed. 121 48 EACH
122 122 Supply and fix in repair bell push switch piano flush type 5 Amp one way. complete all as specified and directed. 122 16 EACH
123 123 Supply and fix Call bell, ding dong type AC 230 volt, single phase, 50 HZ complete all as specified and directed. 123 16 EACH
124 124 Supply and fix ceiling rose, PVC/Polycarbonate isolated body complete all as specified and directed. 124 208 EACH
125 125 Supply and fix stepped type electronic fan regulator flush type and connecting up. Regulator shall be 240 volts on the existing phenolic laminated sheet of make specified in Appendix 'B' to particular specifications complete all as specified and directed. 125 48 EACH
126 126 Supply and fix factory made sheet metal enclosures distribution boards, (protection class IP-42) double door, suitable for mounting MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, tripple pole and neutral, 4 ways, 240 volts\nNote :- MCBs shall be measured and paid for separately under respective item of this schedule. 126 3 EACH
127 127 Supply and fix factory made sheet metal enclosures distribution boards, (protection class IP-42) double door, suitable for mounting MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, single pole and neutral, 8 ways, 240 volts\nNote :- MCBs shall be measured and paid for separately under respective item of this schedule. 127 16 EACH
128 128 Supply and fix MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before.. 128 111 EACH
129 129 Supply and fix MCB, Single pole and neutral, 230 volt, 32 to 40 Amp rating 10KA, C series fixed in DBs catered herein before. 129 16 EACH
130 130 Supply and fix MCB, TPN, 415 volt, 63 Amp rating 10KA, C series fixed in DBs catered herein before. 130 3 EACH
131 131 Disconnecting / talking down carefully existing ceilling fan of any size, single phase, AC, 240 volts, kept in safe custody for refixing / Hanging and connecting the same ceilling fan of size 1200mm/1400mm sweep, single phase 230 Volts, after cleaning/painting/greassing etc, and hanging properly on roof of building with the provisioning of suitable sizes of mild steel clamps / plungers, nuts, bolts etc as reqd at site complete all as specified and directed by Garrison Engineer/ Engr-in-Charge.\n 131 32 EACH
132 132 Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete.\nNote:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment.\n(b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish. 132 190 PER RUNNING METRE
133 133 Supply, fixing in replacement and connecting wall mounted LED light fitting 20 Watt LED (6000K/6500K) (1200/1144mm) extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection including taking down old fittings complete all as specified and directed..\nNote :- Fitting shall be of Make Philips cat part No BN 100CLED 405-6500 PSU L1 20 GR Havells cat part No LUMILINEPLUSBS22WLED865SPCSS or equivalent model of make specified in Appendix 'B' to particular specifications. \nNote :- Serviciable old light fittings retrieved under this item including tube light/bulb, shall be deposited in the MES store yard of AGE (E/M) under GE (AF) Gorakhpur for checking of serviciability and receipt shall be obtained before allowing payment for new fittings.\n(ii) Light fittings (other than servicable ) retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. 133 80 EACH
134 134 Supply, fixing in replacement and connecting wall mounted LED light fitting 2 feet long 10 Watt LED (6000K/6500K) (1200/1144mm) extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection including taking down old fittings complete all as specified and directed..\nNote :- Fitting shall be of Make Philips cat part No BN 021 LED10S 6500 PSU GR S1, Havells cat part No LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make specified in Appendix 'B' to particular specifications. \nNote :- Serviciable old light fittings retrieved under this item including tube light/bulb, shall be deposited in the MES store yard of AGE (E/M) under GE (AF) Bamrauli for checking of serviciability and receipt shall be obtained before allowing payment for new fittings.\n(ii) Light fittings (other than servicable ) retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. 134 42 EACH
135 135 Supply and fix in replacement lamp holder PVC/polycarbonate type with back plate suitable for batten fitting including LED lamps of 9 watt complete all as specified and directed by Garrison Engineer / Engr-in-Charge. 135 80 EACH
136 136 Supply, fixing, connecting and testing LED light fitting 30 Watt, 6000 K pressure die cast aluminium housing, heat resistant toughned glass, with frame IP-66 protection, better optics for uniform distribution roadway luminairies complete and connecting the fitting electrically including provision of single arm bracket made of 40 mm dia light grade GI pipe (1.2 metre long) bending to angle of 120 degree and mild steel flat iron 32 x 6 mm clamps of suitable size two numbers including nut, bolt and washers fixed on pole complete. \nNote :- (i) Fitting shall be of Philips cat part No BRP046 LED 30 CW MR S1 PSU GR, Bajaj cat part No Havells cat part No ENDURAPEARLSL30WLED757SASYTOPCMP or equivalent model of make specified in Appendix 'B' to of Particular Specifications. Light fitting of other make of higher capacity may be used without any price adjustment. \n(ii) Cable from junction box to fitting shall be measured and paid for separately under respective item of this schedule of works .\n(iii) MS clamps shall be painted with two coat of aluminium paint over a coat of redoxide primer.\n 136 6 EACH
137 137 Supplying, laying, testing and commissioning of XLPE insulated, PVC bedded, galvanised steel strip armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade, connecting both end with suitable lugs of cross sectional area 25 sqmm 3.5 core, complete all as specified and directed by Garrison Engineer / Engr-in-Charge.\nNote :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule. 137 33 PER RUNNING METRE
138 138 Supply and fix ceiling fans 1200 mm sweep white in colour of Aluminium blades(three numbers) and body,double ball bearing, down rod.fan motor,pair of canopy, shackle, assembly kit etc suitable for SP 230 to 250 volts, 50 Hz, AC supply including three core PVC insulated multistanded copper conductor cable size 1.5 sq.mm from ceiling rose including taking down old ceiling fan and deposited to store yard of AGE EM of GE (AF) Gorakhpur complete all as specified and directed by Garrison Engineer / Engr-in-Charge.\nNote :- (i) Make Havells CAT No ES-50, 5 star (energy saving fan) or equivalent model of make specified in Appendix 'B' to particular specifications.\n 138 16 EACH
139 139 Supply and fix exhaust fans (metallic) of 300/308 mm sweep, heavy duty, four blade, double ball bearing ,1400 RPM, minimum suitable for SP, 230 / 250V, 50 Hz, AC supply with louver shutters including making holes in brick wall of suitable size and disturbed surfaces shall be made good to match the existing finishes complete all as specified and directed by Garrison Engineer / Engr-in-Charge.\nNote :- (i) Make Havells Model No : Ventil Air or equivalent model of make mentioned in Appendix 'B' to particular specifications.\n(ii) Unit rate quoted by tenderer is deemed to include the cost of demolition /dismanting of brick work in wall for making hole and making good the surfaces to match existing schedule of finishes. 139 16 EACH
140 140 Supply, fixing and commissioning water heater storage type 25 liters capacity, BEE 5 star and 8 bar pressure rated, stainless steel (minimum wall thickness 2mm) tank with feroglass coated inner container energy saving high density PUF insulation vertical, ABS shock proof plastic body grouting of studs in wall in cement mortar (1:3) nuts, washers, provision of two numbers PVC braided connection 600mm long with brass nuts and two numbers brass chromium plated angular valve suitable for 15mm bore pipe for water supply connection complete.\nNote :- (i) GI pipe will be measured and paid for separtely under respective items of schedule of works. \n(ii) Point wiring, switch & socket shall be measured and paid for separtely under respective items of this schedule of works.\n(iii) Geyser shall be of make Crompton Greaves Model No. : MONZAEC of equivalent model of make mentioned in Appendix 'B' to particular specifications. 140 16 EACH
141 141 Supply and fix temper proof energy meter electronic type single phase 5-30 Amps current rating single phase 230V AC with optical port dully scaled in place of unsericeable energy meter including electric connection with single core multi stranded copper conductor cable with flexible conduit of proper size.\nNote :- (a) The meter will be fixed on wooden board of suitable size.\n 141 20 EACH
142 142 Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4 mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Garrison Engineer / Engr-in-Charge. \nNotes \n(i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.\n(ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate.\n(iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted. 142 2 EACH SET
143 143 Taking down carefully sub main, wiring Aluminimum / copper of any size including earth continuity conductor on teak wood batten or conduit and removing from site and making good the surfaces of wall etc to meet the existing finishes etc complete all as specified and directed.\nNote :- Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. \n 143 190 PER RUNNING METRE
144 144 Taking down existing DB TPN 4 way and DB SPN 8 ways of any capacity and size and removing from site and making good the surfaces of wall etc to meet the existing finishes complete all as specified and directed by Garrison Engineer / Engr-in-Charge. \nNote :- Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. \n 144 19 EACH
145 145 Demolition of brick masonry quions, arches, pillars etc, but excluding ashlar fackings, dressed stonewrk and precast concrete articles.\nNote : (i) Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. \n(ii) Rubbish shall be removed out site MOD land. 145 1.5 PER CUBIC METRE
146 146 Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (RCC water tank over roof slab) including cutting reinforcement as required to facilitate demolition all as specified and directed. 146 5 PER CUBIC METRE
147 147 Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete including roof padding, including cleaning the surfaces with wire brushes etc complete all as specified and directed. 147 27.33 PER CUBIC METRE
148 148 Taking down 110mm dia PVC SWR rain water / vent pipe of any size including fittings etc from walls/ trenches. \nNote :- Excavation and earth work shall be measure and paid separately under respective item.\n(ii) Bed concrete shall be made good for laying new pipe under respective item of this schedule. 148 110 PER \nRUNNING \nMETRE
149 149 Demolition of brick tiles flat or edges pointed in any type of mortar complete all as specified and directed.\nNote :- (i) Material (other than servicable ) retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. \n(ii) Rubbish shall be removed out site MOD land. 149 60 PER TEN SQUARE METRE
150 150 Dismantling of cast iron pipes, or reinforced concrete drain pipe or asbestos cement pipes jointed in cement mortar and taking out of trenches if required of 75 mm dia and any location. \nNote :- Excavation and earth work required shall be measured and paid for separately. 150 30 PER \nRUNNING \nMETRE
151 151 Dismantling of cast iron pipes, or reinforced concrete drain pipe or asbestos cement pipes jointed in cement mortar and taking out of trenches if required of 100 mm dia and any location. \nNote :- Excavation and earth work required shall be measured and paid for separately. 151 40 PER \nRUNNING \nMETRE
Disclaimer :