Sales : +91-777 804 8217
| Name of Work: Construction of Girls Resident Hostel at MAMC Agroha (Hisar) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CIVIL WORKS \nEarth workin excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10sqm on plan),inluding dressing of side sand ramming of bottoms, lift upto1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. (HSR - 4.14.1) ALL KIND OF SOIL | BI01010001010000000000000515BI0100001113 | 2209.88 | Cum |
| 2 | 2 | Filling available excavated earth (excluding rock) in trenches, cum plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.( HSR - 4.32) | BI01010001010000000000000515BI0100001114 | 883.95 | Cum |
| 3 | 3 | Providing and injecting chemical emulsion for PRE- sqm ONSTRUCTIONAL anti termite treatment and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20%. (HSR-4.39) | BI01010001010000000000000515BI0100001115 | 1267 | SQM |
| 4 | 4 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): HSR 5.8\n5.8.3 From brick work in cement mortar | BI01010001010000000000000515BI0100001116 | 7500 | nos. |
| 5 | 5 | Centering and shuttering including strutting, propping etc. and removal of form work for: FOUNDATION, FOOTING, BASE FOR COLUMN. (HSR-6.29.1) | BI01010001010000000000000515BI0100001117 | 498 | SQM |
| 6 | 6 | Centering and shuttering including strutting, propping etc. and removal of form work for Columns, piers, abutments, pillars, posts and struts (HSR-6.29.3) | BI01010001010000000000000515BI0100001118 | 762.02 | SQM |
| 7 | 7 | Centering and shuttering including strutting, propping etc. and removal of form work for Lintels, beams, plinth beams, girders, bressumers and cantilevers. (HSR-6.30.5) | BI01010001010000000000000515BI0100001119 | 2150.21 | SQM |
| 8 | 8 | Centering and shuttering including strutting, propping etc. and removal of form work for Suspended floors, roofs, landings, balconies and access platform (HSR-6.30.3) | BI01010001010000000000000515BI0100001120 | 2210.25 | SQM |
| 9 | 9 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases . (HSR-6.30.7) | BI01010001010000000000000515BI0100001121 | 49.58 | SQM |
| 10 | 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Cement Concrete 1:4:8 with stone aggregate 40mm nominal size in foundation and plinth. (HSR-6.1.6) | BI01010001010000000000000515BI0100001122 | 220 | cum |
| 11 | 11 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge . \n(Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix).All works up to plinth level. (HSR-6.25.1) | BI01010001010000000000000515BI0100001123 | 387.83 | CUM |
| 12 | 12 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge .\n(Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement isused as per design mix).All works above plinth level up to floor IV level. (HSR-6.25.2) | BI01010001010000000000000515BI0100001124 | 571.48 | CUM |
| 13 | 13 | Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). All works above plinth and up to floor IV level M-20 grade plain cement concrete (cement content considered @ 300 kg/cum) . (HSR-6.22.1) | BI01010001010000000000000515BI0100001125 | 12.89 | CUM |
| 14 | 14 | 20 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded:HORIZONTAL . (HSR-6.12.2) | BI01010001010000000000000515BI0100001126 | 140.7 | SQM |
| 15 | 15 | 20 mm thick EXTRA cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded :HORIZONTAL(HSR-6.12.2) | BI01010001010000000000000515BI0100001127 | 140.7 | SQM |
| 16 | 16 | 20 mm thick cement plaster damp-proof course 1 :3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded:Vertical. (HSR-6.12.1) | BI01010001010000000000000515BI0100001128 | 357.09 | SQM |
| 17 | 17 | Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) (HSR-7.21.2) | BI01010001010000000000000515BI0100001129 | 93.73 | CUM |
| 18 | 18 | Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS:2222 in superstructure above plinth level up to floor four level in cement mortar 1:6 (1 cement : 6 coarse sand) :With non-modular bricks. (HSR-7.23.1) | BI01010001010000000000000515BI0100001130 | 310.42 | CUM |
| 19 | 19 | Brick work in cement mortor 1:6 in foundation and plinth (Brick suppled by the Department free of cost) N.S.. | BI01010001010000000000000515BI0100001131 | 15 | CUM |
| 20 | 20 | Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level upto floor IV level.Cement mortar 1:4 (1 cement :4 coarse sand). (HSR-7.28.2) | BI01010001010000000000000515BI0100001132 | 2191.02 | sqm |
| 21 | 21 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR-9.18) | BI01010001010000000000000515BI0100001133 | 14 | each |
| 22 | 22 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 75x75 mm deep chase. (HSR-9.17.1) | BI01010001010000000000000515BI0100001134 | 193.68 | mtr |
| 23 | 23 | Base course of floors consisting of 100mm thick cement concrete 1:8:16 and 100mm sand or stone filling.(HSR-10.1) | BI01010001010000000000000515BI0100001135 | 811.08 | Sqm |
| 24 | 24 | Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. (HSR-10.4) | BI01010001010000000000000515BI0100001136 | 707.38 | Sqm |
| 25 | 25 | (HSR-10.4) 2nd floor | BI01010001010000000000000515BI0100001137 | 707.38 | Sqm |
| 26 | 26 | Conglomerate floor 40mm thick cement Concrete topping 1:2:4.\n(HSR-10.8) terrace floor | BI01010001010000000000000515BI0100001138 | 7.76 | Sqm |
| 27 | 27 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)size of tiles 600mmx600mm. NITCO, KAJA-RIA, SOMANI, ORIENT & JOHNSONS. (HSR-10.69.2) | BI01010001010000000000000515BI0100001139 | 1799.52 | sqm |
| 28 | 28 | Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.size of tiles\n600mmx600mm.(HSR-10.70.2) | BI01010001010000000000000515BI0100001140 | 1799.52 | sqm |
| 29 | 29 | Providing and laying ceramic glazed floor (ANTISKID) tiles of size 300mmx300mm of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.\nNote: Tile shall be of premium quality (first quality) of reputed manufacturer like NITCO, KAJA-RIA, SOMANI, ORIENT & JOHNSONS.(HSR-10.59) | BI01010001010000000000000515BI0100001141 | 234.3 | SQM |
| 30 | 30 | Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S :15622 (thickness to be specified by the manufacturer) ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR-10.58) | BI01010001010000000000000515BI0100001142 | 1331.25 | SQM |
| 31 | 31 | Providing and fixing of Kotastone slab flooring over20mm (average)thick base laidover andjointed with grey cement slurry mixed with pigment tomatch theshade of the slab,including rubbing and polishing complete with base of cement mortar 1:4(1cement : 4 coarse sand) :25 MM (HSR-10.37.1) | BI01010001010000000000000515BI0100001143 | 504.96 | SQM |
| 32 | 32 | Providing and fixing of Kota stone slabs 20mmthick in risers of steps,skirting,dado and pillars laid on 12mm(average) thick\ncement mortar1:3 (1cement:3coarsesand) andjointed withgreycement slurrymixed with pigment to matchthe shade of the\nslabs, including rubbing and polishing complete. (HSR-10.38) | BI01010001010000000000000515BI0100001144 | 149.4 | SQM |
| 33 | 33 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. (HSR-10.42) | BI01010001010000000000000515BI0100001145 | 195.3 | RMTR |
| 34 | 34 | Providing and laying Polished Granite stone flooring in required design and patterns,in linear as well as curvilinear portions of the building all complete as per the architectural drawings with18mmthickstone slabover 20mm(average)thick base of cement mortar1:4 (1cement:4coarsesand) laid andjointed with cement slurry and pointing with white cement slurry admixed with pigment ofmatching shade including rubbing,curingand polishingetc. all complete as specified and as directed by the Engineer- in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (HSR-10.50.1) | BI01010001010000000000000515BI0100001146 | 24.38 | SQM |
| 35 | 35 | Providing and laying flamed finish Granite stone flooring in required design and patterns,in inear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20mm (average) thick base of cement mortar1:4(1cement:4coarsesand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc.all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (HSR-10.49.1) | BI01010001010000000000000515BI0100001147 | 96.62 | SQM |
| 36 | 36 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:.(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). (HSR- 28.14) | BI01010001010000000000000515BI0100001148 | 233.99 | SQM |
| 37 | 37 | 15 mm cement plaster on rough side of single or half brick wall of mix:1 :4 (1 cement: 4 coarse sand). (HSR- 11.9.1) | BI01010001010000000000000515BI0100001149 | 2081.14 | Sqm |
| 38 | 38 | Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :\n15 mm wide and 15 mm deep groove. (N.S.) | BI01010001010000000000000515BI0100001150 | 676.23 | RM |
| 39 | 39 | Providing and finishing 12mm thick cement plaster 1:6. (HSR- 11.5.4) | BI01010001010000000000000515BI0100001151 | 7643.39 | Sqm |
| 40 | 40 | 1 0 mm thick cement plaster 1 :3 (1 cement: 3 fine sand) (HSR- 11.4.2) | BI01010001010000000000000515BI0100001152 | 2268.94 | Sqm |
| 41 | 41 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. HSR 11.35 | BI01010001010000000000000515BI0100001153 | 400 | Sqm |
| 42 | 42 | Providing and applying two coats white cement based putty of approved brand and manufacturer,over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material, labourcharges, scaffolding, sundries etc. complete. (HSR- 11.58) | BI01010001010000000000000515BI0100001154 | 11314.3 | sqm |
| 43 | 43 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : HSR 11.67\n11.67.1 Water thinnable cement primer | BI01010001010000000000000515BI0100001155 | 9912.34 | sqm |
| 44 | 44 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied ). (HSR- 11.95.1) | BI01010001010000000000000515BI0100001156 | 2760.28 | sqm |
| 45 | 45 | Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade(Two or more coat on new work). (HSR- 11.71.1) | BI01010001010000000000000515BI0100001157 | 9912.34 | sqm |
| 46 | 46 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work(ON PRESSED STEEL DOOR FRAMES). (HSR- 11.73.1) | BI01010001010000000000000515BI0100001158 | 467.17 | Sqm |
| 47 | 47 | Float glass panes HSR 12.9.7\n12.9.7.1 4 mm thick glass pane (weight not less than 10kg/sqm). | BI01010001010000000000000515BI0100001159 | 25 | Sqm |
| 48 | 48 | Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete: 20 mm dia. (HSR- 12.48.2) | BI01010001010000000000000515BI0100001160 | 190.4 | RMTR |
| 49 | 49 | Providing and fixing pressed steel door frames conforming to IS:4351,manufactured from commercial mild steel sheet of 2.0 mm thickness, includinghinges,jamb,lockjamb,bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00mm,pressed mild steel welded or rigidly fixed together by mechanical means,including M.S.pressed butt hinges 2.5mm thick with mortar guards,lockstrike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:Profile E Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (HSR- 13.3.3.2) | BI01010001010000000000000515BI0100001161 | 1300 | RMTR |
| 50 | 50 | Providing and fixing carbon steel galvanised (minimum coating 5micron) dashfastener of10 mm dia double threaded 6.8grade (yield strength 480N/mm2) , counter sunk head, comprising of 10mm dia polyamide PA6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.SIZE 10X120MM. (HSR- 13.5.3) | BI01010001010000000000000515BI0100001162 | 1496 | EACH |
| 51 | 51 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: HSR 12.37\n12.37.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws | BI01010001010000000000000515BI0100001163 | 178.39 | Sqm |
| 52 | 52 | Providing and fixing bright/matt finished Stainless Steel handles of approved quality & make with necessary screw set call:125MM. (HSR- 12.75.1) | BI01010001010000000000000515BI0100001164 | 416 | each |
| 53 | 53 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : HSR 12.98\n12.98.1 300x16 mm | BI01010001010000000000000515BI0100001165 | 20 | each |
| 54 | 54 | 12.98.2 250x16 mm | BI01010001010000000000000515BI0100001166 | 20 | each |
| 55 | 55 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : HSR 12.99\n12.99.4 150x10 mm | BI01010001010000000000000515BI0100001167 | 20 | each |
| 56 | 56 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : HSR 12.102\n12.102.1 125 mm | BI01010001010000000000000515BI0100001168 | 20 | each |
| 57 | 57 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.\nWith stainless steel cover plate minimum 1.25 mm thickness. (HSR- 12.160.1) | BI01010001010000000000000515BI0100001169 | 2 | each |
| 58 | 58 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :\nFixed portion (Anodised aluminium transparent or dyed to required shade according to IS: 1868, minimum anodic coating of grade AC 15) (HSR- 12.157.1.1) | BI01010001010000000000000515BI0100001170 | 463.05 | kg |
| 59 | 59 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium transparent or dyed to required shade according to IS: 1868, minimum anodic coating of grade AC 15). (HSR- 12.157.2.1) | BI01010001010000000000000515BI0100001171 | 534.27 | kg |
| 60 | 60 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.\n(a) Pre-laminated particle board with decorative lamination on one side & balancing lamination on both side. (HSR- 12.158.2) | BI01010001010000000000000515BI0100001172 | 47.85 | sqm |
| 61 | 61 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):\nb) with float glass panes of 5.0mm thickness. (HSR- 12.159.2) | BI01010001010000000000000515BI0100001173 | 6.96 | SQM |
| 62 | 62 | Providing and fixing ISi marked, IS: 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete:100x75x3.50 mm FOR DUCTS. (HSR- 12.56.2) | BI01010001010000000000000515BI0100001174 | 126 | EACH |
| 63 | 63 | 125x90x4.00 mm FOR MAIN DOOR (HSR- 12.56.1) | BI01010001010000000000000515BI0100001175 | 4 | EACH |
| 64 | 64 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.MS TUBE. (HSR-13.42.1) | BI01010001010000000000000515BI0100001176 | 2000 | kg |
| 65 | 65 | 13.29.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | BI01010001010000000000000515BI0100001177 | 2500 | kg |
| 66 | 66 | Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect.\nNote:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.Thermo-Mechanically Treated bars of grade Fe-500D kg or more. (HSR-6.33.6) | BI01010001010000000000000515BI0100001178 | 186000 | KG |
| 67 | 67 | Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area, as per technical clause 201 of MORT&H specifications.\nBy Manual Means. (HSR- 17.1) | BI01010001010000000000000515BI0100001179 | 0.24 | HACTARE |
| 68 | 68 | Providing and laying 60mm thick factory made cement concrete inter1ocking sqm 128 495 623 paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over (BIS 15658:2006) and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (HSR- 10.76) | BI01010001010000000000000515BI0100001180 | 1200 | SQM |
| 69 | 69 | Cast in Sib.I Cement Concrete M20 Kerb Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-1 O grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408: USING CONC. MIXER. (HSR- 34.1.1) | BI01010001010000000000000515BI0100001181 | 614 | RMTR |
| 70 | 70 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete (HSR- 34.49) | BI01010001010000000000000515BI0100001182 | 184.2 | SQM |
| 71 | 71 | Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 sqm cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR- 6.13) | BI01010001010000000000000515BI0100001183 | 99 | SQM |
| 72 | 72 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: HSR 6.1\n1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size). (HSR- 6.1.2) | BI01010001010000000000000515BI0100001184 | 7.43 | CUM |
| 73 | 73 | Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. HSR 10.22\n10.22.1 40 mm wide and 4 mm thick | BI01010001010000000000000515BI0100001185 | 219.6 | RMT |
| 74 | 74 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay non-modular bricks of class designation 7.5 including grouting with cement mortar 1 :4 (1 cement : 4 fine sand). (HSR- 7.55) | BI01010001010000000000000515BI0100001186 | 165 | RMT |
| 75 | 75 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction ofEngineer-in-charge.(HSR- 5.7.4) | BI01010001010000000000000515BI0100001187 | 31.05 | CUM |
| 76 | 76 | Dismantling steel work in built up sections in angles, tees, flats kg and channels Including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. (HSR- 5.33) | BI01010001010000000000000515BI0100001188 | 132.3 | KG |
| 77 | 77 | Demolishing R.C.C. work manually/ by mechanical means cum including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge. (HSR- 5.25) | BI01010001010000000000000515BI0100001189 | 4.05 | CUM |
| 78 | 78 | Demolishing R.C.C. work manually/ by mechanical means cum including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge.Nominal concrete 1: 1.5:3 or richer mix (i/c equivalent cum design mix) (HSR- 5.23.1) | BI01010001010000000000000515BI0100001190 | 9 | CUM |
| 79 | 79 | Earth filling under floors/road/along with boundary wall/in open area with dune sand (tiba sand), brought from outside (any lead), in 15 cm layer including laying, dressing, watering ramming, consolidating, excavation, carriage, loading, unloading and compensation, etc., complete (NS) | BI01010001010000000000000515BI0100001191 | 1537.73 | Cum |
| 80 | 80 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge (Plan area shall be measured for payment\nWith average thickness of 120 mm and minimum thickness at khurra as 65 mm. N.S. | BI01010001010000000000000515BI0100001192 | 773.31 | sqm |
| 81 | 81 | Supplying and fixing of water resistant Poly VinylChloride (PVC) FALSE CEILING TILE 12MM thick (595MM X 595 MM) with plain grid size 24mm x 26mm x 1mm Make Sant Gobin USG Boral with M 8 fastner complete in all respect / Direction of Engineer-in-Charge. (NS) | BI01010001010000000000000515BI0100001193 | 238.02 | SQM |
| 82 | 82 | Providing ,fixing on Architect recommended partition, avg. 1 mm thk select laminate of CENTURY, MARINO, FORMICA LAMINATE approved colour, make as approved, glued with approved phenol formaldehyde based adhesive or approved equivalent overlaying on substrate without any gap/air bubbles pressed uniformly to line level and plumb, item complete with all edge lipping with water based PU TW lipping mounted flush to surface as per detailed drawings and Architects recommendations: all accessories, fixing implements , men material and lift upto 6 mtrs. Finished complete with all necessary masking with avg. mim 10mm wide masking tape before applying polish to edge lipping and getting mock up approved by Architect/Engineer in charge. Item to include protecting finished item by avg. 20 microns thk polythene sheet till handover of facility complete. Item to be completed in all respects as per drawings and instructions from Project in charge. (NS) | BI01010001010000000000000515BI0100001194 | 356.78 | SQM |
| 83 | 83 | Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete :300X16MM. (N.S.) | BI01010001010000000000000515BI0100001195 | 63 | each |
| 84 | 84 | Providing and fixing ISI marked stainless steel sliding door bolts with nuts and screws etc. complete :200X16MM. (N.S.) | BI01010001010000000000000515BI0100001196 | 63 | each |
| 85 | 85 | Providing and fixing ISI marked bright finished stainless steel hanging type floor door stopper with necessary screws, etc. complete. (N.S. ) | BI01010001010000000000000515BI0100001197 | 186 | each |
| 86 | 86 | Providing and fixing bright/matt finished Stainless Steel handles of approved quality & make with necessary screw set. LENGTH:900 MM ,DIA 20 MM Make Ozone, Dorama. (NS) | BI01010001010000000000000515BI0100001198 | 2 | each |
| 87 | 87 | Providing and fixing bright finished ISI marked stainless steel tower bolts with necessary screws etc. complete ::150MM. (N.S.) | BI01010001010000000000000515BI0100001199 | 416 | each |
| 88 | 88 | Supplying and fixing of DOMAL JINDAL MAKE ALUMINIUM minimum 16 GAUGE PROFILE. DESIGN BASE EURO STANDERD HEAVY DUTY MULTI FUNCTION WINDOW. SINGLE AND MULTI FUNCTION LOCKING GROVE . HIGH STANDRED EURO HARDWARE FITTING.3 track sliding WINDOW withmesh shutter – partly fixed and partly openable (glazed / wiremesh as per drawing, duly manufactured using (108 mm x 45 mm) for outerframes, (39 mm x 75 mm) for sliding shutter frames capable of mountingsingle glazing system with hot dip galvanized up to 50 microns of prefabricated & welded through fusion welding. The window sash shall befitted with 5 mm thick brown toughened reflective glass of reputedmake and mesh shutter frame shall be (30 mm x 48.5 mm) fitted with S.S. mesh of 304 grade on rollers/ pulley duly fixed with approved colour EPDM Gasket for sash & Glazing bead shallbe co extruded with Grey colour . Door/window shall be provided with standard hardware & multi point locking system of bent handle espagulate. the system is to be installed at the site using anchorfasteners, silicon rubber sealant, easy glazing/deglazing at site etc. INCLUDING TRANSPORTAION, LABOUR, complete in all respects as per direction of Engineer-in-charge. (NS) | BI01010001010000000000000515BI0100001200 | 177.41 | SQM |
| 89 | 89 | Supplying and fixing of DOMAL JINDAL MAKE ALUMINIUM minimum 16 GAUGE PROFILE. DESIGN BASE EURO STANDERD HEAVY DUTY MULTI FUNCTION WINDOW. SINGLE LOCKING GROVE . HIGH STANDRED EURO HARDWARE FITTING.BOTTOM HUNG VENTILATOR – partly fixed / partly openable (glazed / wiremesh) as per drawing duly manufactured using (108 mm x 45 mm) for outerframes, (39 mm x 75 mm) for shutter frames capable of mountingsingle glazing system with hot dip galvanized up to 50 microns of prefabricated & weldedthrough fusion welding. The window sash shall befitted with 5 mm thick brown toughened reflective glass of reputedmake and mesh shutter frame shall be (30 mm x 48.5 mm) fitted with S.S. mesh- on rollers/ pulley duly fixed withGrey colour EPDM Gasket for sash & Glazing bead shallbe co extruded with approved colour & mesh shutters shall be fitted with S.S.wiremesh of 304 grade,System shall beprovided standard hardware, single point lockingusing cockspur handle and friction stays. and the system is to be installedat the site using anchor fasteners, silicon rubbersealant, easy glazing/ deglazing at site etc. complete in all respects as per the direction of Engineer-in-charge. (NS) | BI01010001010000000000000515BI0100001201 | 47.22 | SQM |
| 90 | 90 | Supplying and fixing of DOMAL JINDAL MAKE ALUMINIUM minimum 16 GAUGE PROFILE. DESIGN BASE EURO STANDERD HEAVY DUTY MULTI FUNCTION WINDOW. FIXED WINDOW, partly fixed / partly openable (galzed / wiremesh) duly manufactured using (108 mm x 45 mm) for outerframes, with hot dip galvanized up to 50 microns of prefabricated & weldedthrough fusion welding. The window sash shall befitted with 5 mm thick approved toughened reflective glass of reputedmake and duly fixed with approved colour EPDM Gasket for sash & Glazing bead shallbe co extruded with appoved colour . WINDOW shall be provided with standard hardware . the system is to be installed at the site using anchorfasteners, silicon rubber sealant, easy glazing/deglazing at site etc. ( W) complete in all respects as per direction of Engineer-in-charge. (NS) | BI01010001010000000000000515BI0100001202 | 7.68 | SQM |
| 91 | 91 | Structural Glazing Providing and Fixing with aluminium section (AC 15) 50 x 50mm x 2mm thickness incluidnt gasket, silicon, radtap, ABRO Tape incluidng necessary screw, angle with complete fitting and including 5 mm thick toughened reflective glass of Saint Gobin, Modi Guard, AIS of approved make Complete in all respect or as per direction of Engineer-in-Charge N.S. | BI01010001010000000000000515BI0100001203 | 102.76 | SQM |
| 92 | 92 | Providing & fixing of cuboard 2'-0 deep made up of water proof , terminte treatment ,WPC 18 MM thick board MIN DENSITY OF 650 KG/CUM of Reputed Brands for Sides , Top , Bottom & Horizontal & Vertical shelves of box cupboard complete as per Drawings. The front Openable shutters shall be 25mm thick WPC and its outer face covered with 1.0 mm laminate of approved colour and makes . The exposed edge of shutter & shelves shall be covered with edge binding tape matching with laminate colour . The shutter shall be fixed to the Cupboard Box with S.S. Continous Hinges 3/4\"X3/4\" . The item shall Iinclude all Accessories steel Handle 150mm, steel Tower Bolts 150mm, curtain rod, Hanging rods, Cupboard lock and 40mmX40mm (6 NO.) S.S. Studs etc. Complete in all respects as per drawing/ Direction of Engineer-in-charge (only front area of the cupboard shall be measured for payment) (NS) | BI01010001010000000000000515BI0100001204 | 300 | sqm |
| 93 | 93 | PUBLIC HEALTH WORK \nProviding and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mm. (HSR 22.210.4) | BI01010001010000000000000515BI0100001205 | 58 | Each |
| 94 | 94 | Providing and fixing toilet paper holder C.P Brass. (HSR 22.42.1) | BI01010001010000000000000515BI0100001206 | 58 | Each |
| 95 | 95 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (HSR 22.119.2) | BI01010001010000000000000515BI0100001207 | 58 | Each |
| 96 | 96 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore. (HSR 22.108.1) | BI01010001010000000000000515BI0100001208 | 290 | Each |
| 97 | 97 | Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating. (HSR - 22.132.2) | BI01010001010000000000000515BI0100001209 | 116 | Each |
| 98 | 98 | Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (HSR- 22.33) | BI01010001010000000000000515BI0100001210 | 58 | Each |
| 99 | 99 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White vitreous chinaware Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. (HSR- 22.1.4) | BI01010001010000000000000515BI0100001211 | 58 | Each |
| 100 | 100 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR- 22.15) | BI01010001010000000000000515BI0100001212 | 58 | Each |
| 101 | 101 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms. (HSR- 22.115.1) | BI01010001010000000000000515BI0100001213 | 58 | Each |
| 102 | 102 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter. (HSR- 22.102.2) | BI01010001010000000000000515BI0100001214 | 58 | Each |
| 103 | 103 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with LP./ H.P.H.D. plastic ball. 50 mm nominal bore, 242mm long, weighing not less than 1240 gms. (HSR- 22.124.5) | BI01010001010000000000000515BI0100001215 | 5 | Each |
| 104 | 104 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore. (HSR- 22.104) | BI01010001010000000000000515BI0100001216 | 58 | Each |
| 105 | 105 | Providing and fixing jet spray with 2'-6\" long PVC pipe. (N.S.) | BI01010001010000000000000515BI0100001217 | 58 | Each |
| 106 | 106 | Providing and fixing in position CP Brass Grab Bar of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. (N.S.) | BI01010001010000000000000515BI0100001218 | 1 | Each |
| 107 | 107 | Providing & Fixing in position C.P./ Aluminium Khunti of approved make (to the approval of Engineer-in-Charge ) fixed into wall with CP brass screws and rawl plugs etc. complete in all respect. (f) Aluminium khunti with 6 pegs. (N.S.) | BI01010001010000000000000515BI0100001219 | 58 | Each |
| 108 | 108 | P/F in position PVC flexible tube connection of approved make (to the approval of Engineer-in-Charge) Complete in all respect.b) PVC tube connection of size 15mm x 450mm with CP brass nut. (N.S.) | BI01010001010000000000000515BI0100001220 | 290 | Each |
| 109 | 109 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm . (HSR-4.16.1.3) | BI01010001010000000000000515BI0100001221 | 382.02 | MTR |
| 110 | 110 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes 6 KG PRESSURE having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. INCLUDING ALL DOORS AND SIMPLE FITTING , Cutting holes making good surface of R.c.c. or brick wall , elbow , tee with door , coupler ,bends etc. ( N.S.)\n110 mm o/d pipes | BI01010001010000000000000515BI0100001222 | 107 | Mtr |
| 111 | 111 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (HSR-9.60) | BI01010001010000000000000515BI0100001223 | 50 | Each |
| 112 | 112 | SEWERAGE SYSTEM (INTERNAL WORKS)\nProviding and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) \nA neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-incharge. 25 Litres capacity. (HSR-22.216.1) | BI01010001010000000000000515BI0100001224 | 58 | each |
| 113 | 113 | Providing, laying and jointing glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diameter.( HSR-22.163.2) | BI01010001010000000000000515BI0100001225 | 76.1 | METRE |
| 114 | 114 | ( HSR-22.163.3) 200mm diameter | BI01010001010000000000000515BI0100001226 | 198.92 | METRE |
| 115 | 115 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design\n(HSR - 22.164.2 )150 MM OUTER DIAMETER | BI01010001010000000000000515BI0100001227 | 76.1 | METRE |
| 116 | 116 | (HSR - 22.164.3 )200 MM OUTER DIAMETER | BI01010001010000000000000515BI0100001228 | 198.92 | METRE |
| 117 | 117 | Constructing brick masonry inspection Chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design.\n(b) Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping). (HSR - 21.84.2 ) | BI01010001010000000000000515BI0100001229 | 12 | each |
| 118 | 118 | M) Masonry Chambers\nEXTRA FOR EVERY 0.30 METER DEPTH OF INSPECTION CHAMBER\n(HSR - 21.85.2 ) b) 450mm X 600mm | BI01010001010000000000000515BI0100001230 | 12 | each |
| 119 | 119 | Constructing brick masonry inspection Chamber sizes as given below upto 0.60 metre average depth in cement mortar 1:5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement R.C.C. 1:2:4 slab 100 mm thick/cement concrete topping, 50mm thick with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per I.S.I. specification painted with 3 coats of black bitumastic superior paint complete as per standard design.\n(c) Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab). (HSR - 21.84.3 ) | BI01010001010000000000000515BI0100001231 | 4 | each |
| 120 | 120 | M) Masonry Chambers\nEXTRA FOR EVERY 0.30 METER DEPTH OF INSPECTION CHAMBER\n (HSR-21.85.3) c) 600mm X 900mm | BI01010001010000000000000515BI0100001232 | 4 | each |
| 121 | 121 | Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar complete to the requirement of the Engineer in-charge . \na) SINGLE ROAD GULLY CHAMBER\ni) size 610 mm x 457mm x 800mm (HSR-21.87.1.1) | BI01010001010000000000000515BI0100001233 | 32 | each |
| 122 | 122 | Reduction for every 7.5 cm depth of road gully chamber from the rate of item no.29.87 above. \n (HSR-21.88.1) a) SINGLE road gully chamber | BI01010001010000000000000515BI0100001234 | 32 | each |
| 123 | 123 | Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 (as per specified in item No.10.6) in foundations 1st class brick work laid in cement sand mortar 1:5, 40 mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12mm in thickness of 1:2 cement sand plaster and finished with floating coat of neat cement 1 mm thick left absolutely smooth polished and correct to templates including labour for fixing the C.I. road gully grating and frame including painting with coal tar complete to the requirement of the Engineer in-charge . b) DOUBLE ROAD GULLY CHAMBER\nsize 1448mm x 457mm x 800mm (HSR-21.87.2.1) | BI01010001010000000000000515BI0100001235 | 6 | each |
| 124 | 124 | Reduction for every 7.5 cm depth of road gully chamber from the rate of item no.29.87 above. \n(HSR-21.88.2) DOUBLE road gully chamber | BI01010001010000000000000515BI0100001236 | 6 | each |
| 125 | 125 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With sewer bricks conforming to IS : 4885.( HSR-22.166.2.2) | BI01010001010000000000000515BI0100001237 | 20 | each |
| 126 | 126 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR 22.181 | BI01010001010000000000000515BI0100001238 | 20000 | litre |
| 127 | 127 | Construction of rectangular standard brick masonry manhole chambers to standard drawings on S.W. pipe sewers or other circular pipe sewers upto the required depth in 1.5 cement sand mortar, lime concrete in bed and sides of pipe sewer and cement concrete 1:2:4 in benching, 12 mm thick water tight 1:2 cement sand plaster with a floating coat of neat cement and finished with 2 coats of sodium silicate on interior surface where required, reinforced cement concrete slab 180mm thick fixing 560 mm internal diameter C.I. manhole cover and frame weight not less than 2.5 quintal painted with 3 coats of black bitumen paint, fixing galvanised malleable iron steps embedded in 1:2 cement sand mortar complete. the rate covers the cost of M.S. steel for R.C.C. slab labour for fixing and carriage of C.I. manhole frame and cover and malleable iron steps from the stores of the Engineer-in-charge of the works to the site of works. The rate also include the cost of accurately planned and fitted centring, supports for all works as well as for all curves and special work, cleaning out their beds etc. sodium silicate shall be supplied free of cost at the stores of the Engineer-in-charge.\nOn 200 mm internal diameter pipe sewer.\nfor 1.80m depth below ground level. (HSR-21.90 .4.1) | BI01010001010000000000000515BI0100001239 | 2 | each |
| 128 | 128 | Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1 :3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge.Type:- Extra Heavy Duty Set (EHD-10) 560MM Clear Opening. (HSR-21.93.3) | BI01010001010000000000000515BI0100001240 | 2 | EACH |
| 129 | 129 | Fixing galvanized malleable iron holder bats hold fasts to pipe line fixed on walls and ceilings including all cutting to walls and making good to original condition. (HSR-20.30)\n20mm I/d of pipeline. (HSR-20.30.2) | BI01010001010000000000000515BI0100001241 | 139.2 | each |
| 130 | 130 | 25mm I/d of pipeline. (HSR-20.30.3) | BI01010001010000000000000515BI0100001242 | 270 | each |
| 131 | 131 | 50mm I/d of pipeline. (HSR-20.30.6) | BI01010001010000000000000515BI0100001243 | 110 | each |
| 132 | 132 | Providing and fixing of gun metal gate valve with C.I. Wheel of approved quality (screwed end) (HSR-22.98)\n20mm I/d of pipeline . (HSR-22.98.2) | BI01010001010000000000000515BI0100001244 | 85 | each |
| 133 | 133 | 25mm I/d of pipeline (HSR-22.98.1) | BI01010001010000000000000515BI0100001245 | 40 | each |
| 134 | 134 | 32mm I/d of pipeline . (HSR-22.98.3) | BI01010001010000000000000515BI0100001246 | 30 | each |
| 135 | 135 | 40mm I/d of pipeline . (HSR-22.98.4) | BI01010001010000000000000515BI0100001247 | 4 | each |
| 136 | 136 | 50mm I/d of pipeline . (HSR-22.98.5) | BI01010001010000000000000515BI0100001248 | 5 | each |
| 137 | 137 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes 6 kg / cm2 , having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. ( INTERNAL RING)( HSR-22.86)\n20 mm nominal outer dia Pipes. ( HSR-22.86.2) | BI01010001010000000000000515BI0100001249 | 139.2 | METRE |
| 138 | 138 | 25 mm nominal outer dia Pipes . ( HSR-22.86.3) | BI01010001010000000000000515BI0100001250 | 270 | METRE |
| 139 | 139 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. ( TERRACE) . (HSR-22.88)\n25 mm dia nominal bore. (HSR-22.88.3) | BI01010001010000000000000515BI0100001251 | 270 | METRE |
| 140 | 140 | 32mm dia nominal bore. (HSR-22.88.4) | BI01010001010000000000000515BI0100001252 | 215 | METRE |
| 141 | 141 | 40 mm dia nominal bore . (HSR-22.88.5) | BI01010001010000000000000515BI0100001253 | 10 | METRE |
| 142 | 142 | 50 mm dia nominal bore . (HSR-22.88.6) | BI01010001010000000000000515BI0100001254 | 110 | METRE |
| 143 | 143 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : (HSR-22.89)\n20 mm dia nominal bore. (HSR-22.89.2) | BI01010001010000000000000515BI0100001255 | 139.2 | METRE |
| 144 | 144 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (HSR-22.94)\n20 mm nominal bore . (HSR-22.94.2) | BI01010001010000000000000515BI0100001256 | 27.84 | EACH |
| 145 | 145 | 25 mm nominal bore . (HSR-22.94.3) | BI01010001010000000000000515BI0100001257 | 54 | EACH |
| 146 | 146 | 32 mm nominal bore . (HSR-22.94.4) | BI01010001010000000000000515BI0100001258 | 43 | EACH |
| 147 | 147 | 40 mm nominal bore . (HSR-22.94.5) | BI01010001010000000000000515BI0100001259 | 2 | EACH |
| 148 | 148 | 50 mm nominal bore . (HSR-22.94.6) | BI01010001010000000000000515BI0100001260 | 22 | EACH |
| 149 | 149 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main (HSR-22.100)\n20 mm nominal bore. (HSR-22.100.2)\n | BI01010001010000000000000515BI0100001261 | 27.84 | EACH |
| 150 | 150 | 25 mm nominal bore . (HSR-22.100.3) | BI01010001010000000000000515BI0100001262 | 54 | EACH |
| 151 | 151 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. HSR 22.106\n22.106.1 15 mm nominal bore | BI01010001010000000000000515BI0100001263 | 120 | EACH |
| 152 | 152 | Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): 100 mm diameter Class I. ( HSR - 22.162.1.1) | BI01010001010000000000000515BI0100001264 | 2 | EACH |
| 153 | 153 | Providing and fixing M.S. grills of required pattern in frames for protection of water tank with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.( HSR - 12.50.1) | BI01010001010000000000000515BI0100001265 | 476.15 | KG |
| 154 | 154 | Making connection of newly laid sewer in walls of existing manhole of fully charge sewer including cost of pluging sewer, desilting, removal of sullage water and making good of khudda.\nSewer connections upto 300 mm id. (N.S.) | BI01010001010000000000000515BI0100001266 | 2 | EACH |
| 155 | 155 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. (HSR--22.120) | BI01010001010000000000000515BI0100001267 | 58 | EACH |
| 156 | 156 | Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge.Up to 200 mm internal diametre. (HSR--20.49.1) | BI01010001010000000000000515BI0100001268 | 5 | EACH |
| 157 | 157 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.\n15 mm nominal bore . (HSR--22.107.1) | BI01010001010000000000000515BI0100001269 | 174 | EACH |
| 158 | 158 | Providing and fixing Cast Iron Detachable Joints class-15 marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with 15:5382 & IS:10292 and appropriate number of nut and bolts marked with 15:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) 100mm i/d CID Joint. ( HSR - 20.58.2) | BI01010001010000000000000515BI0100001270 | 5 | EACH |
| 159 | 159 | Providing and fixing P.V.C. waste pipe for sink or wash basin including U.P.V.C. wastepipe 6 kg / cm2 including all fitting ( plain or door ) e.g bends , junction , cowl , offsets acesses piece , clamps etc. fixing with rubbering / solvent cement joints, laying pipes in proper slopes and poly. Adequate means of supporting / clamping adjustable requied as site requirement of pipe i,e. cutting & making holes on wall / floors in brick work / r.c.c. and making good where required (32 MM O/D ,)The rate includes the cost of all types of clamping and no other separate rate shall be given. The supports required for the Pipes shall be be made up of cold rolled steel of quality DX51 or greater with minimum GSM of 275 or greater and shall be have universal mounting slot on the front of the rail for accurate positioning of fasteners and system compatible round and long holes on back of the rail the pipe. The pipe clamps shall be be either split type with EPDM inner rubber lining or shall be be MSS-SP manufactured with FM approval and UL listing. (NS)\nThreaded rods shall be be of 4.8 strength class or greater and necessary accessories such as Hexagonal Nuts and Bolts shall be be of 8.8 strength class. Note: This item is inclusive of all accessories, packing charges, Transportation, complete in all respect as approved by architect and engineer incharge at all floors/ ht upto 38m. | BI01010001010000000000000515BI0100001271 | 58 | Each |
| 160 | 160 | Providing and fixing Robe Hooks and Model no. F880004 or equivalent\nNote: This item is inclusive of all accessories, packing charges, Transportation, Labour installation complete in all respect as approved by architect and engineer incharge at all floors/ ht upto 38m. (NS) | BI01010001010000000000000515BI0100001272 | 519 | Each |
| 161 | 161 | Supplying, installing, testing and commissioing of uPVC Soil, Waste, Vent and Rain water pipes 6 kg / cm2 (SWR) conforming to IS:13592 solvent / rubber (yellow seal) ring manufactured with co-moulded technology providing 100% leak proof joints inclusive of all necessary specials manufactured conforming to IS:14735, likes bends, swept tee's, offsets, door bends or tees, bends, junctions, cowls, threaded type cleanout, etc. The rate shall include chasing of walls, laying of pipes as per standard working procedures. All the internal drainage pipes are to be suspended below the ceiling level and the pipes are to be supported by modular clamps. The rate includes the cost of all types of clamping and no other separate rate shall be given. The supports required for the Pipes shall be be made up of cold rolled steel of quality DX51 or greater with minimum GSM of 275 or greater and shall be have universal mounting slot on the front of the rail for accurate positioning of fasteners and system compatible round and long holes on back of the rail the pipe. The pipe clamps shall be be either split type with EPDM inner rubber lining or shall be be MSS-SP manufactured with FM approval and UL listing. Threaded rods shall be be of 4.8 strength class or greater and necessary accessories such as Hexagonal Nuts and Bolts shall be be of 8.8 strength class. \nDN 50 mm o/d PP mineral filled SWR pipe (To be used for connection of Floor Drain to Rain Drainage stack) \nNote: This item is inclusive of all accessories, packing charges, Transportation, Installation complete in all respect as approved by architect and engineer incharge at all floors/ ht upto 38m. (NS) | BI01010001010000000000000515BI0100001273 | 150 | Mtr |
| 162 | 162 | Providing and fixing UPVC pipe 6 kg / cm2 including all fitting ( plain or door ) e.g bends , junction , cowl , offsets acesses piece , clamps etc. fixing with rubbering / solvent cement joints, laying pipes in proper slopes and poly. Adequate means of supporting / clamping adjustable requied as site requirement of pipe i,e. cutting & making holes on wall / floors in brick work / r.c.c. and making good where required (110 MM O/D ) The rate shall include chasing of walls, laying of pipes as per standard working procedures. All the internal drainage pipes are to be suspended below the ceiling level and the pipes are to be supported by modular clamps. The rate includes the cost of all types of clamping and no other separate rate shall be given. The supports required for the Pipes shall be be made up of cold rolled steel of quality DX51 or greater with minimum GSM of 275 or greater and shall be have universal mounting slot on the front of the rail for accurate positioning of fasteners and system compatible round and long holes on back of the rail the pipe.\nThe pipe clamps shall be be either split type with EPDM inner rubber lining or shall be be MSS-SP manufactured with FM approval and UL listing. Threaded rods shall be be of 4.8 strength class or greater and necessary accessories such as Hexagonal Nuts and Bolts shall be be of 8.8 strength class. Note: This item is inclusive of all accessories, packing charges, Transportation, complete in all respect as approved by architect and engineer incharge at all floors/ ht upto 38m. (NS) | BI01010001010000000000000515BI0100001274 | 452 | metre |
| 163 | 163 | Providing & Fixing Floor Trap with minimum 50mm water seal having 3nos of DN 40/50mm inlets and 1nos of DN 110mm Top inlet and 1nos of DN 75mm outlet. The baffle construction shall be be air tight under all circumstances. The inspection plug enables to access the area under the baffle in order to inspect and clean this area. The Floor Trap volume shall be be in such a way that a maximal discharge capacity is reached. In case not all the inlets are used PP-blind plugs are to be added to the Floor Trap. These blind plugs shall be secure a leakage free sealing of unused connections to the Floor Trap. The rate includes the complete cost of clamping as per the detailed drawing complete in all respects.\nNote: This item is inclusive of all accessories, packing charges, Transportation, complete in all respect as approved by architect and engineer incharge at all floors/ ht upto 38m. (NS) | BI01010001010000000000000515BI0100001275 | 116 | EACH |
| 164 | 164 | Providing and fixing CP BRASS soap Dish Holder . (NS) | BI01010001010000000000000515BI0100001276 | 58 | EACH |
| 165 | 165 | Providing and fixing CP BRASS towel Ring. (NS) | BI01010001010000000000000515BI0100001277 | 58 | EACH |
| 166 | 166 | Providing and fixing G.I. extension nipple for water tank pipe, fittings of approved quality \n 20 mm nominal bore. (NS) | BI01010001010000000000000515BI0100001278 | 6 | EACH |
| 167 | 167 | 25mm nominal bore. (NS) | BI01010001010000000000000515BI0100001279 | 7 | EACH |
| 168 | 168 | 32 mm nominal bore . (NS) | BI01010001010000000000000515BI0100001280 | 8 | EACH |
| 169 | 169 | 50 mm nominal bore . (NS) | BI01010001010000000000000515BI0100001281 | 9 | EACH |
| 170 | 170 | Providing and fixing UPVC pipe 6 kg / cm2 including all fitting ( plain or door ) e.g bends , junction , cowl , offsets acesses piece , clamps etc. fixing with rubbering / solvent cement joints, laying pipes in proper slopes and poly. Adequate means of supporting / clamping adjustable requied as site requirement of pipe i,e. cutting & making holes on wall / floors in brick work / r.c.c. and making good where required (90 MM O/D )Note: The rate shall include chasing of walls, laying of pipes as per standard working procedures. All the internal drainage pipes are to be suspended below the ceiling level and the pipes are to be supported by modular clamps. The rate includes the cost of all types of clamping and no other separate rate shall be given. The supports required for the Pipes shall be be made up of cold rolled steel of quality DX51 or greater with minimum GSM of 275 or greater and shall be have universal mounting slot on the front of the rail for accurate positioning of fasteners and system compatible round and long holes on back of the rail the pipe. \nThe pipe clamps shall be be either split type with EPDM inner rubber lining or shall be be MSS-SP manufactured with FM approval and UL listing. Threaded rods shall be be of 4.8 strength class or greater and necessary accessories such as Hexagonal Nuts and Bolts shall be be of 8.8 strength class. This item is inclusive of all accessories, packing charges, Transportation, complete in all respect as approved by architect and engineer incharge at all floors/ ht upto 38m. (NS) | BI01010001010000000000000515BI0100001282 | 374.2 | metre |
| 171 | 171 | Providing and fixing floor Clean out plug 4\" (FCO). ) (NS) | BI01010001010000000000000515BI0100001283 | 120 | EACH |
| 172 | 172 | Providing and fixing Clean out plug 4\" (COP). (NS) | BI01010001010000000000000515BI0100001284 | 58 | EACH |
| 173 | 173 | Providing and fixing PVC CORNER 9\"X9\" CERA( NS) | BI01010001010000000000000515BI0100001285 | 58 | EACH |
| 174 | 174 | FIRE FIGHTING ITEMS:\nSupplying, Installation, testing and commissioning of PRESSURE PUMP(450 LPM) suitable for automatic operations and consisting for the following complete in all respects.Horizontal type multistage, centrifugal split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure 3.5 Kg per sqcm at highest and fastest outlet at a specified flow of 450 LPM at 20 Mtr head conforming to IS 1520. 7.5 HP motor, IP 55 protection for enclose horizontal, foot mounted type with class F insulation, confirming to IS 3245.Including electrical panel , cable and controlling , pressure switch and and automatic on -off foundation finishing , strainer , suction and delivery connection , air release valve pressure gauge complete. (NS) | BI01010001010000000000000515BI0100001286 | 2 | Each |
| 175 | 175 | Providing, laying, fixing and testing and commissioning of \"C \" class heavy duty MS Pipe conforming to indian standard IS 1239:3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nut bolts, gasket etc. on surface and providing angle iron support of cement concrete block as support including painting with two or more coats af synthetic enamel paint of required shade complete in all respects .\na ) 100mm inter dia. (N.S.) | BI01010001010000000000000515BI0100001287 | 60 | Mtr. |
| 176 | 176 | Supplying, Installation, Testing and Commissioning of GM Single headed internal hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects. (N.S.) | BI01010001010000000000000515BI0100001288 | 7 | Each |
| 177 | 177 | Supplying, Installation, Testing and Commissioning gun-metal 63 mm dia gun metal branch pipe (ISI marked) with 20 mm (nominal internal dia) size Gun meal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required . (N.S.) | BI01010001010000000000000515BI0100001289 | 7 | Each |
| 178 | 178 | Supplying, Installation, Testing and Commissioning of single suction collecting head with cast iron body, nose coupling (drawout connection) with female outlet complete bolts, nuts and rubber insertions, but without 100mm dia. MS suction pipe (with puddle flange) with a foot valve complete as required. ((N.S.) | BI01010001010000000000000515BI0100001290 | 7 | Each |
| 179 | 179 | Providing and fixing fire brigade intel connection of cast iron body with Gun metal 63mm dia instantanceous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS: 904 (to be connected to static tank). (N.S.)\nFour Way inlet connection | BI01010001010000000000000515BI0100001291 | 1 | Each |
| 180 | 180 | Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required. (N.S.) | BI01010001010000000000000515BI0100001292 | 7 | Each |
| 181 | 181 | Supplying, Installation, Testing and Commissioning of Non-percolating flexible CP HOUSE as per IS-8423 / 1994 ISI marked 63mm dia x 15 m long complete with instantaneous type gun-metal 63 mm dia male & female coupling (IS: 903) bound and riveted to hose pipes. (N.S.) | BI01010001010000000000000515BI0100001293 | 7 | Each |
| 182 | 182 | Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with updo date amendments, complete with the rubber horse pipe (IS-444/1987) 20mm dia 30 meter long type-2 hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required completw with GI pipe. (N.S.) | BI01010001010000000000000515BI0100001294 | 7 | Each |
| 183 | 183 | Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect. (N.S.) | BI01010001010000000000000515BI0100001295 | 7 | Each |
| 184 | 184 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6 mm thickness M.S. sheet with front glass door having looking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings, etc including painting the metal portion with one coat of ready mixed printer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing, etc.\nSize - 600 mm wide x 600 mm high x 300 mm deep (For RRL Reel) . (N.S.) | BI01010001010000000000000515BI0100001296 | 7 | Each |
| 185 | 185 | Supplying & fixing air vessel made of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required .(N.S.) | BI01010001010000000000000515BI0100001297 | 1 | Each |
| 186 | 186 | Providing and fixing of pressure switch of approved make in MS pipe line suitable for the pressure up 15kg/cm2 & including connection with main panel etc, as required complete in all respect. (N.S.) | BI01010001010000000000000515BI0100001298 | 1 | Each |
| 187 | 187 | Providing and fixing S.S. Pressure Gauge complete as required complete in all respect. (N.S.)\nDial diameter 150mm calibration 0-16 Kg | BI01010001010000000000000515BI0100001299 | 3 | Each |
| 188 | 188 | Providing and fixing FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufacturer's specification ISI Mark in all respect. (N.S.)\n4.5 KG. Capacity | BI01010001010000000000000515BI0100001300 | 18 | Each |
| 189 | 189 | Supplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVES PN 1.6 with gun metal seal duly ISI marked complete with rubber insertions, nuts, bolts and washers matching flanges of required thickness complete as per specifications. (N.S.)\n100mm dia. | BI01010001010000000000000515BI0100001301 | 2 | Each |
| 190 | 190 | Providing and fixing in position automatic brass ball Cock in tanks. (N.S.)\nBrass ball Cock with rod and platic ball\n25mm i/d | BI01010001010000000000000515BI0100001302 | 1 | Each |
| 191 | 191 | Making connection with the existing G.I. branch main up to 40mm size pipe including cutting of existing pipe line, threading of pipe lines from both ends and fixing of g.i tee etc. In the pipe line ( including cost of g.i tee) complete in all respects. (N.S.) | BI01010001010000000000000515BI0100001303 | 6 | Each |
| 192 | 192 | Supplying & Fixing of Energy saving double side EXIT sign board (size 12\" x 6\" x 4\") fabricated in 18 swg CRC sheet with LED and acrylic sheet both side display, well ventilated, having nominal size LED lamp, battery backup 6 hour to be installed on wall/ceiling etc. complete as required. (MAKE: FGL/LEGRAND/ABB) (NS) | BI01010001010000000000000515BI0100001304 | 15 | Each |
| 193 | 193 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. HSR-22.181) | BI01010001010000000000000515BI0100001305 | 5000 | LTR |
| 194 | 194 | ELECTRICAL WORK\nWiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper\nconductor cable in 1.6 mm thick PVC conduit pipe. (HSR-23.4.1)\n(HSR-23.4.1.1) GROUP-A | BI01010001010000000000000515BI0100001306 | 519 | EACH |
| 195 | 195 | Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. (HSR-23.4.2)\n(HSR-23.4.2.1)GROUP-A | BI01010001010000000000000515BI0100001307 | 8 | EACH |
| 196 | 196 | Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch (HSR-23.4.3.1)\n(23.4.3.1 )GROUP-A | BI01010001010000000000000515BI0100001308 | 62 | EACH |
| 197 | 197 | POWER OUTLETS\nWiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required. (HSR-23.4.4.1)\n(HSR-23.4.4.1)GROUP-A | BI01010001010000000000000515BI0100001309 | 227 | EACH |
| 198 | 198 | Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required. (HSR-23.4.5.1)\n(HSR-23.4.5.1)GROUP-A | BI01010001010000000000000515BI0100001310 | 164 | EACH |
| 199 | 199 | Supply and erection of sheet steel enclosures 1 pole/2 pole/4 pole on walVon existing pedestal complete as required. (HSR-23.22.3)\n(HSR-23.22.3.2 )S.P.N. or DP enclosure suitable for DP MCB | BI01010001010000000000000515BI0100001311 | 60 | Each |
| 200 | 200 | Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.(HSR-23.8.10)\n(HSR-23.8.10.1)1 & 2 Modules including combined plate for Telephone and data | BI01010001010000000000000515BI0100001312 | 10 | Each |
| 201 | 201 | (HSR-23.8.10.2) 3 Modules ( 15Amp Socket for AC) | BI01010001010000000000000515BI0100001313 | 60 | EACH |
| 202 | 202 | (HSR-23.8.10.3) 4 Modules | BI01010001010000000000000515BI0100001314 | 6 | EACH |
| 203 | 203 | (HSR-23.8.10.4) 6 Modules ( for Computer - 2 nos 5Amp 6 pin socket + 1 no. 15 amp switch ) | BI01010001010000000000000515BI0100001315 | 228 | EACH |
| 204 | 204 | (HSR-23.22.3.2) S.P.N. or DP enclosure suitable for DP MCB | BI01010001010000000000000515BI0100001316 | 60 | Each |
| 205 | 205 | Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR-23.8.11)\n(HSR-23.8.11.1) 5 amp 1 way switch | BI01010001010000000000000515BI0100001317 | 5 | EACH |
| 206 | 206 | (HSR-23.8.11.2) 5 amp 2 way switch | BI01010001010000000000000515BI0100001318 | 5 | EACH |
| 207 | 207 | (HSR-23.8.11.3) 15 amp 1 way switch | BI01010001010000000000000515BI0100001319 | 228 | EACH |
| 208 | 208 | (HSR-23.8.11.4) 5 amp Socket | BI01010001010000000000000515BI0100001320 | 456 | EACH |
| 209 | 209 | (HSR-23.8.11.5) 15 amp 6 pin Socket | BI01010001010000000000000515BI0100001321 | 60 | EACH |
| 210 | 210 | (HSR-23.8.11.10) Blanking plate | BI01010001010000000000000515BI0100001322 | 100 | EACH |
| 211 | 211 | PVC CONDUITING FOR CIRCUIT WIRING\nSupply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. (HSR-23.7.6) \nPVC pipe of 20 mm dia. (HSR-23.7.6.1) | BI01010001010000000000000515BI0100001323 | 300 | METRE |
| 212 | 212 | PVC pipe of 25 mm dia. (HSR-23.7.6.2) | BI01010001010000000000000515BI0100001324 | 5500 | METRE |
| 213 | 213 | PVC pipe of 32 mm dia. (HSR-23.7.6.3) | BI01010001010000000000000515BI0100001325 | 200 | METRE |
| 214 | 214 | PVC pipe of 40 mm dia. (HSR-23.7.6.4) | BI01010001010000000000000515BI0100001326 | 100 | METRE |
| 215 | 215 | CIRCUIT WIRING\nWiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable\n1100 Volts grade in existing MS/PVC Conduit etc as required. (HSR-23.5.6)\n1 run of Size 1.50 Sqmm(1/1.40mm) . (HSR-23.5.6.1) | BI01010001010000000000000515BI0100001327 | 350 | METRE |
| 216 | 216 | 1 run of Size 2.50 Sqmm(1.1.80mm) . (HSR-23.5.6.2) | BI01010001010000000000000515BI0100001328 | 2500 | METRE |
| 217 | 217 | 1 run of Size 4 Sqmm(1/2.24mm) . (HSR-23.5.6.3) | BI01010001010000000000000515BI0100001329 | 4500 | METRE |
| 218 | 218 | 1 run of Size 6 Sqmm(1/2.80mm). (HSR-23.5.6.4) | BI01010001010000000000000515BI0100001330 | 50 | METRE |
| 219 | 219 | ADOPTER BOXES\nSupply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below . (HSR-23.8.3)\n75 mm x 75 mm x 60 mm deep M.S. box. (HSR-23.8.3.1) | BI01010001010000000000000515BI0100001331 | 10 | EACH |
| 220 | 220 | 100 mm x 100 mm x 60 mm deep M.S. box. (HSR-23.8.3.2) | BI01010001010000000000000515BI0100001332 | 10 | EACH |
| 221 | 221 | 180 mm X 100 mm X 60 mm deep M.S. Box . (HSR-23.8.3.3) | BI01010001010000000000000515BI0100001333 | 15 | EACH |
| 222 | 222 | 200 mm X 150 mm X 60 mm deep metal box . (HSR-23.8.3.4) | BI01010001010000000000000515BI0100001334 | 15 | EACH |
| 223 | 223 | FAN BOX\nSupply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cmlong M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. (HSR-23.8.4) | BI01010001010000000000000515BI0100001335 | 74 | EACH |
| 224 | 224 | step type Fan Regulator 2 modules 300 watt. (HSR-23.8.11.7) | BI01010001010000000000000515BI0100001336 | 74 | EACH |
| 225 | 225 | PVC CONDUITING FOR LAN / CCTV / TEL. SYSTEM\nSupply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. (HSR-23.7.6)\nPVC pipe of 20 mm dia.(HSR-23.7.6.1) | BI01010001010000000000000515BI0100001337 | 300 | METRE |
| 226 | 226 | PVC pipe of 25 mm dia. (HSR-23.7.6.2) | BI01010001010000000000000515BI0100001338 | 3000 | METRE |
| 227 | 227 | PVC pipe of 32 mm dia. (HSR-23.7.6.3) | BI01010001010000000000000515BI0100001339 | 200 | METRE |
| 228 | 228 | LV OUTLET BOX\nProviding and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. ( HSR-23.8.10)\n1 & 2 Modules including combined plate for Telephone and data. (HSR-23.8.10.1) | BI01010001010000000000000515BI0100001340 | 10 | Each |
| 229 | 229 | 3 Modules. (HSR-23.8.10.2) | BI01010001010000000000000515BI0100001341 | 125 | Each |
| 230 | 230 | WIRING FOR LV SYSTEM\nSupply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing\npipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work. (HSR-23.23.8)\n2 pair telephone wire. (HSR-23.23.8.1) | BI01010001010000000000000515BI0100001342 | 100 | METRE |
| 231 | 231 | 4 pair telephone wire. (HSR-23.23.8.2) | BI01010001010000000000000515BI0100001343 | 100 | METRE |
| 232 | 232 | Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required. (HSR-23.23.9) | BI01010001010000000000000515BI0100001344 | 1500 | METRE |
| 233 | 233 | Supplying and drawing of 1 no UTP 4 pair CAT Sa LAN Cable in the existing surface/recess MS/PVC conduit as required. ( HSR-23.23.10) | BI01010001010000000000000515BI0100001345 | 1500 | METRE |
| 234 | 234 | LV OUTLET BOX ASSY.\nProviding and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all\nrespect. (HSR-23.8.11)\nTelephone Socket outlet modular type. (HSR-23.8.11.8) | BI01010001010000000000000515BI0100001346 | 10 | EACH |
| 235 | 235 | Blanking plate. (HSR-23.8.11.10) | BI01010001010000000000000515BI0100001347 | 10 | EACH |
| 236 | 236 | RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type. (HSR-23.8.11.11) | BI01010001010000000000000515BI0100001348 | 125 | EACH |
| 237 | 237 | DISTRIBUTION BOARDS\nSupply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. (HSR-23.22.4)\nTPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) For Flood Lights on Terrace and Acs in rooms.(HSR-23.22.4.5) | BI01010001010000000000000515BI0100001349 | 7 | EACH |
| 238 | 238 | TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) -For Light. (HSR-23.22.4.6) | BI01010001010000000000000515BI0100001350 | 6 | EACH |
| 239 | 239 | TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing)-For Power. (HSR-23.22.4.7) | BI01010001010000000000000515BI0100001351 | 6 | EACH |
| 240 | 240 | 4 way Plexo Box for MCB IP 65. Make Legrand or equivelent. (NS) | BI01010001010000000000000515BI0100001352 | 6 | EACH |
| 241 | 241 | MCBs\nSupply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- (HSR-23.22.5)\n6 amp. to 32 amp Single Pole. (HSR-23.22.5.1) | BI01010001010000000000000515BI0100001353 | 336 | EACH |
| 242 | 242 | 6 amp to 32 amp. Double POLE . (HSR-23.22.5.3) | BI01010001010000000000000515BI0100001354 | 60 | EACH |
| 243 | 243 | 40 amp to 63 amp. MCB's FOUR POLE. (HSR-23.22.5.8) | BI01010001010000000000000515BI0100001355 | 19 | EACH |
| 244 | 244 | CABLE TRAY\nSupply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. (HSR-23.23.6)\nMS perforated cable tray painted with powder coating 375 X 50 X2mm. (HSR-23.23.6.3) | BI01010001010000000000000515BI0100001356 | 55 | METRE |
| 245 | 245 | CABLING\nSupply of LT Cables. (NS)\n4 x 6 Sq mm Aluminum armoured cable. (NS) | BI01010001010000000000000515BI0100001357 | 300 | METRE |
| 246 | 246 | 4 x16 Sq mm Aluminum armoured cable. (NS) | BI01010001010000000000000515BI0100001358 | 45 | METRE |
| 247 | 247 | 3.5x35 Sq mm Aluminum armoured cable. (NS) | BI01010001010000000000000515BI0100001359 | 45 | METRE |
| 248 | 248 | 3.5x120 Sq mm Aluminum armoured cable. (NS) | BI01010001010000000000000515BI0100001360 | 150 | METRE |
| 249 | 249 | 3.5x240 Sq mm Aluminum armoured cable. (NS) | BI01010001010000000000000515BI0100001361 | 300 | METRE |
| 250 | 250 | CABLE LAYING\nLaying and fixing of cable on surface/ cable tray etc as required:- (HSR-24.2.5)\n16 Sq mm to 35 sqmm 2 to 4 Core. (HSR-24.2.5.2) | BI01010001010000000000000515BI0100001362 | 90 | METRE |
| 251 | 251 | Laying of underground cable in pipe /existing open/closed trench etc as. (HSR-24.2.4)\n2.5 Sq mm to 10 sqmm 2 to 4 Core (24.2.4.1) | BI01010001010000000000000515BI0100001363 | 300 | METRE |
| 252 | 252 | 50 Sq mm to 150 sqmm 2 to 4 Core. (24.2.4.3) | BI01010001010000000000000515BI0100001364 | 150 | METRE |
| 253 | 253 | 185 sqmm to 240 sqmm 3 to 3½ Core. (24.2.4.4) | BI01010001010000000000000515BI0100001365 | 300 | METRE |
| 254 | 254 | WIRE TERMINATIONS\nSupply and erection of copper lugs including crimping etc. entire satisfaction of Engineer-in- Charge of the work.(HSR-24.2.6)\n1.5 sqmm. (HSR-24.2.6.1) | BI01010001010000000000000515BI0100001366 | 10 | EACH |
| 255 | 255 | 2.5sqmm. (HSR-24.2.6.2) | BI01010001010000000000000515BI0100001367 | 500 | EACH |
| 256 | 256 | 4.0sqmm. (HSR-24.2.6.3) | BI01010001010000000000000515BI0100001368 | 492 | EACH |
| 257 | 257 | CABLE GLANDS\nSupply and erection of suitable compression type brass cable glands for underground Cable :-(HSR-24.2.7)\nUp to 6.0 sqmm Cable 2 to 4 Core. (HSR-24.2.7.1) | BI01010001010000000000000515BI0100001369 | 10 | SET |
| 258 | 258 | 10 sqmm to 16s qmm Cable 2 to 4 Core. (HSR-24.2.7.2) | BI01010001010000000000000515BI0100001370 | 14 | SET |
| 259 | 259 | 25 sqmm to 50 sqmm Cable 2 to 4 Core. (HSR-24.2.7.3) | BI01010001010000000000000515BI0100001371 | 12 | SET |
| 260 | 260 | 120 sqmm to 185 sqmm Cable 3 to 32 Core. (HSR-24.2.7.5) | BI01010001010000000000000515BI0100001372 | 2 | SET |
| 261 | 261 | 240 sqmm to 185 sqmm Cable 3 to 32 Core. ((HSR-24.2.7.6) | BI01010001010000000000000515BI0100001373 | 4 | SET |
| 262 | 262 | CABLE LUGS\nSupply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work . (HSR-24.2.8)\n4 sqmm to 6 sqmm. (HSR-24.2.8.2) | BI01010001010000000000000515BI0100001374 | 40 | EACH |
| 263 | 263 | 16 sqmm. (HSR-24.2.8.4) | BI01010001010000000000000515BI0100001375 | 68 | EACH |
| 264 | 264 | 35 sqmm. (HSR-24.2.8.6) | BI01010001010000000000000515BI0100001376 | 36 | EACH |
| 265 | 265 | 95 sqmm. (HSR-24.2.8.9) | BI01010001010000000000000515BI0100001377 | 2 | EACH |
| 266 | 266 | 120sqmm. (HSR-24.2.8.10) | BI01010001010000000000000515BI0100001378 | 10 | EACH |
| 267 | 267 | 240sqmm. (HSR-24.2.8.13) | BI01010001010000000000000515BI0100001379 | 12 | EACH |
| 268 | 268 | CABLE ROUTE MARKER\nSupply and erection of cable route marker made of 50 cm long 1 O mm dia M.S. Rod welded/riveted at the top with 1 O cm dia 3 mm thick MS plate inscribed with 'cable' word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level. (HSR-24.2.10) | BI01010001010000000000000515BI0100001380 | 10 | EACH |
| 269 | 269 | HDPE PIPE\nS/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.(HSR-24.5.2)\nDWC/HDPE pipe 90/75 mm outer dial inner dia. (HSR-24.5.2.4) | BI01010001010000000000000515BI0100001381 | 150 | METRE |
| 270 | 270 | DWC/HDPE pipe 120/105 mm outer dial inner dia. (HSR-24.5.2.5) | BI01010001010000000000000515BI0100001382 | 300 | METRE |
| 271 | 271 | EARTHING\nEarthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having\nlocking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.(HSR-24.1.3) | BI01010001010000000000000515BI0100001383 | 4 | EACH |
| 272 | 272 | Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode. (HSR-24.1.5) | BI01010001010000000000000515BI0100001384 | 4 | EACH |
| 273 | 273 | Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. (HSR-24.1.7) | BI01010001010000000000000515BI0100001385 | 15 | METRE |
| 274 | 274 | Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. (HSR-24.1.8) | BI01010001010000000000000515BI0100001386 | 160 | METRE |
| 275 | 275 | EARLY STREAMER EMISSION LIGHTNING PROTECTION SYSTEM\nSupply, Erection, Installation & Commissioning of External Lightning Wide Area Protection System based on pro-active Early Streamer Emission (ESE) Technology. No external power source required. Device tested & certified as per NFC17-102 (2011)standards for \"Lightning current impulse of 100Ka in 10/135 wave form. CPRI Tested for 70KA, with protection radius standard 45@ meters / Level-IV protection. Including mast for supporting the device. Lightning Strike Recorder-7 digits electro mechanical display to record the lightning current in an IP 67 enclosure with minimum sensitivity of 1500A & maimum capacity of 220KA (8/20µs second waveform.) the Down Conductor which is a 70 Sq. mm flexible, single core PVC insulated copper cable with fiing accessories. advance chemical gel maintenance free earth for the Lightning Protection System, with earth enhancing compounds to treat the soil for lowering the effective ground impedance. Maintenance free earth pits made of ground enhancing reslow grounding minerals - 25 Kg each and 250 microns copper bonded ground rods -3 nos of size 3mtr. length and 25.4mm diameter connected with each other with 25 x 3 mm Copper Strip and high performance earth clamps & polyplastic earth pit chamber with covers. (NS) | BI01010001010000000000000515BI0100001387 | 1 | EACH |
| 276 | 276 | Supply, installation, testing and commissioning of following MV cubicle type totally enclosed, Free standing type, powder coated, dust, damp and vermin proof, indoor type Distribution Board/Panel complete with2 mm thick CRCA SHEET with 75mmx40mmx6mm chanel iron base fram, for operation on 3 phase 4 wire 50Hz A.C. supply, busbars, MV danger notice plate, interconnections with suitable capacity aluminium leads/ solid aluminium strips/ rods, connection of incoming and outgoing cables with thimbles, and having following incoming and outgoing switchgears complete as per technical specification and as required. Make : Schenider, L&T, ABB, Indo Asian. (NS) \nNOTE:\nAll MCCBs shall have Ics=Icu=100%\nMCB Should be connected through terminal Strip of suitable rating\nExtended rotary operating mechanism with door interlocking with defeat feature and padlock facility. MCCB should have spreader links & phase barriers.\nMV PANEL - LIGHTING SYSTEM\nINCOMER:\n1 Nos. MCCB as per following details/ specifications:\n400 Amp 415 volts, 35 KA FP MCCB with thermal magnetic release having variable current settings of O/L, S/C protection and E/ F Module.\nR,Y&B phase indicating lamp (LED type) with 6A control SP MCB\n1 No. 0 to 500 V Digital voltmeter with selector switch.\nDigital ammeter with selector switch with one set of Suitable C.Ts.\nBUSBARS:\n500 Amp TPN Aluminium busbars\nOUTGOING:\n1 No. 200 Amps, 415 volts, 35 KA, 3 Pole, MCCB.\n9 No. 100 Amps, 415 volts, 35 KA, 3 Pole, MCCB. | BI01010001010000000000000515BI0100001388 | 1 | Each |
| 277 | 277 | MV PANEL - POWER SYSTEM\nINCOMER:\n1 Nos. MCCB as per following details/ specifications:\n600 Amp 415 volts, 35 KA FP MCCB with thermal magnetic release having variable current settings of O/L, S/C protection and E/ F Module.\nR,Y&B phase indicating lamp (LED type) with 6A control SP MCB\nON, OFF, TRIP indication (LED Type)\n1 No. 0 to 500 V Digital voltmeter with selector switch.\nDigital ammeter with selector switch with one set of Suitable C.Ts.\nBUSBARS:\n800 Amp TPN Aluminium busbars\nOUTGOING:\n1 No. 400 Amps, 415 volts, 35 KA, 3 Pole, MCCB.\n13 No. 100 Amps, 415 volts, 35 KA, 3 Pole, MCCB. (N.S.) | BI01010001010000000000000515BI0100001389 | 1 | Each |
| 278 | 278 | FIXTURES\nsupplying ,fixing , testing & commissioning of various type lighting fixtures as follows. Make Trilux / Philips / Havells (NS)\n12W LED Recessed Downlighter with pressure die cast aluminium heat sink & PC diffuser in white powder coated finish with integrated driver Integra neo . (NS) | BI01010001010000000000000515BI0100001390 | 10 | Each |
| 279 | 279 | 20 Watt LED surface and wall mounted,4' ,aluminiumhausing,efficentheatdissipation,(1150x25x40)mm. (NS) | BI01010001010000000000000515BI0100001391 | 304 | Each |
| 280 | 280 | 15Watt Round LED surface Downlighter ,aluminium hausing with integrated driver,NEO HE DL Surface,fixture size in dia 234 mm,Height 57 mm. (NS) | BI01010001010000000000000515BI0100001392 | 224 | Each |
| 281 | 281 | Mirror light led 10 watt ,surface and wall mounted batten type. (NS) | BI01010001010000000000000515BI0100001393 | 55 | Each |
| 282 | 282 | Supplying and installation 7 Watt led foot light 220/240 V aluminium base,3000K. (NS) | BI01010001010000000000000515BI0100001394 | 10 | Each |
| 283 | 283 | Ceilling fan 1200 mm ,72 Watt,White. (NS) | BI01010001010000000000000515BI0100001395 | 74 | Each |
| 284 | 284 | Exhuast fan 250 mm,Power: 35 watts; Operating Voltage: 230 volts. The noise level is 44 dB and the rated frequency is 50 Hz. (NS) | BI01010001010000000000000515BI0100001396 | 58 | Each |
| 285 | 285 | ECO POLES 4 MTR. (NS) | BI01010001010000000000000515BI0100001397 | 7 | Each |
| 286 | 286 | POLE POST LIGHT CORAL(OPAL)-IP 65. (NS) | BI01010001010000000000000515BI0100001398 | 7 | Each |
| 287 | 287 | FLOOD LIGHT 70 WATT IP65. (NS) | BI01010001010000000000000515BI0100001399 | 6 | Each |
| 288 | 288 | BOLLARD 8 WATT CONE IP 65(0.6)M Landscape. (NS) | BI01010001010000000000000515BI0100001400 | 4 | Each |
| 289 | 289 | 90 W CELING LIGHT. (NS) | BI01010001010000000000000515BI0100001401 | 58 | Each |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy