Addition/Alteration Including Repairs To Married Accommodation At Vikram Batra Enclave , Khetrapal Enclave And Bana Enclave At Suratgarh Military Station

Tender Notice

28186531
Corrigendum : Addition/Alteration Including Repairs To Married Accommodation At Vikram Batra Enclave , Khetrapal Enclave And Bana Enclave At Suratgarh Military Station
Indian
Rajasthan
19-07-2021
02-08-2021
09-07-2021

Tender Details

Addition/Alteration Including Repairs To Married Accommodation At Vikram Batra Enclave , Khetrapal Enclave And Bana Enclave At Suratgarh Military Station

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Jun-2021 Date corrigendum Date 14-07-2021
2 06-Jul-2021 Date corrigendum No 02 Date 19-07-2021
3 12-Jul-2021 Corrigendum No 05 Date 24-07-2021
4 12-Jul-2021 Corrigendum No 04 Other 24-07-2021
5 12-Jul-2021 BOQ Corrigendum BOQ 24-07-2021
6 17-Jul-2021 Corrigendum No 06 Date 02-08-2021
7 19-Jul-2021 Corrigendum No 08 Other 02-08-2021
8 19-Jul-2021 Corrigendum No 07 BOQ 02-08-2021

Key Value

Document Fees
INR 2000 /-
EMD
INR 412660.00 /-
Tender Value
INR 3.37 Crore /-

Attachment

FileName File Description File Size
Tendernotice_1.pdf Tender Document-NIT 512.67
Tender10.pdf Tender Document-Tender documents 1497.79
4E2B0A4B-541D-4DCC-81AC-EDA3A92F24D9.html Tender Notice-Tender Notice 0
Drawings.rar Tender Document-Drawings 2331.89
BOQ_503028.xls Tender Document-BOQ 461.00

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work : Addition/Alteration including repairs to Married Accommodation at Vikram Batra Enclave, Khetrapal Enclave and Bana Enclave at Suratgarh Military Station
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for in this Schedule complete all as specified & as directed. 122.5 Cum
2 2 Demolition of reinforced cement concrete of any description and in any position (reinforcement cut as required to facilitate demolition) not otherwise specifically provided for in this Schedule, complete all as specified & as directed. 10.8 Cum
3 3 Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. 37 Cum
4 4 Taking down cement plaster or cement lime plaster, terrazo etc on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified and as directed. 5827.5 Sqm
5 5 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed. 4457.4 Sqm
6 6 Demolition of stone slabs and tiles of any description or thickness in floors, aprons, etc., laid, bedded and pointed in any mortar, complete all as specified & as directed. 99.8 10 Sqm
7 7 Dismantling boarding, any description, fixed in any position with nails, complete all as specified & as directed. 738 Sqm
8 8 Dismantling of cast iron, wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed. 7 Quintal
9 9 Taking down old unserviceable cooler stand of any size & any type fixed at cill level of windows at Ground Floor & First Floor of building on external face of wall and making good the disturbed portion in cement mortar 1:4 and/or PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as required complete all as specified & as directed. 36 Each Job
10 10 Taking down old rusted & damaged steel windows/ventilators of any description and of any type & size with guard bars / grill / glass / iron mongery including cutting holes for lugs / hold fasts and making good disturbed portion in cement mortar 1:4 and/or PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as required complete all as specified & as directed. 613.5 Sqm
11 11 Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm and not exc. 2 Sqm each, complete all as specified and as directed. 132 Per Leaf
12 12 Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) and making good disturbed portion in cement mortar 1:4 and/or PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as required complete all as specified and as directed. 148 Each
13 13 Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) and making good disturbed portion in cement mortar 1:4 and/or PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as required complete all as specified and as directed. 171 Each
14 14 Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed. 50 Sqm
15 15 Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. 283.2 Cum
16 16 Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed. 131.65 Cum
17 17 Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. 151.55 Cum
18 18 M&L for anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified & as directed. 1048 RM
19 19 M&L for PCC 1:5:10 type E2 using 40 mm graded crushed stone aggregate as in Sunken portion, surroundings of WC seats and similar works, complete all as specified & as directed. 115.5 Cum
20 20 M&L for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. 6 Cum
21 21 M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and as directed. 1.2 Cum
22 22 M&L for cement concrete 1:3:6 type C1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, filling up chowkat/frame hollows, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed. 5 Cum
23 23 M&L for cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, roof kerbs or mud stops, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed. 2 Cum
24 24 M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. including placing in position and set in CM (1:4) complete all as specified & as directed.\nNote :- Reinforcement shall be measured and paid for separately under respective item of this Schedule. 1.2 Cum
25 25 M&L for reinforced cement concrete M-25 grade (Design mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like complete all as specified & as directed.\nNote :- Reinforcement & formwork shall be measured and paid for separately. 10.8 Cum
26 26 Supply only integral liquid water proofing compound (ISI marked) complete all as specified & as directed. 478.82 Litre
27 27 M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed. 37 Cum
28 28 M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as directed.\nNote : Brick work under this item shall be carried out in sewage disposal work (i.e. manholes). 20.4 Cum
29 29 M&L for continuous brick edging, with burnt clay bricks of sub class ‘B’ (old size), with width equal to the depth of the brick, laid dry on end vertically, complete all as specified & as directed. 1700 RM
30 30 M&L for 5 cm thick sand stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. not exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4, complete all as specified and as directed. 61.5 Sqm
31 31 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & as directed. 108.3 Sqm
32 32 M&L for plain, solid, straight chowkats and frames of second class hardwood, wrought, framed rebated on the solid rounded or chamfered, put together with glue, pinned at joints, complete all as specified & directed., complete all as specified & as directed. 5 Cum
33 33 Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same or other opening including easing and adjusting of shutter as required including renewal of unserviceable screws complete all as specified & as directed. 187 Per Leaf
34 34 S&F factory made 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified & as directed. 247.7 Sqm
35 35 Supply and fixing factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified & as directed. 42.9 Sqm
36 36 Supply and fixing factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24(a) of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & as directed. 215.9 Sqm
37 37 S&F factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing, complete all as specified and as directed. 720 RM
38 38 S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. 205.3 Sqm
39 39 M&L for 18/19mm thick prelaminated particle board (ISI marked), exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work/hinges, complete all as specified & as directed. 1789.4 Sqm
40 40 S&F continuous (piano) hinges, mild steel, bright finish or electro galvanized width of flaps 30mm (when open), ISI marked, fixed with CP steel screws complete all as specified and as directed. 860 RM
41 41 S&F butt hinges of size 100mm medium weight, cold rolled mild steel (ISI marked) complete all as specified and as directed. 882 Each
42 42 S&F butt hinges of size 100mm extruded aluminium alloy with galvanized mild steel hinge pin, anodized type B-21 complete all as specified and as directed. 444 Each
43 43 S&F 200 mm long mild steel barrel tower bolts, stove enameled black, with bright bolt and fixed, complete all as specified and as directed. 588 Each
44 44 S&F 200 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and as directed. 296 Each
45 45 S&F 150mm size extruded aluminium alloy handle, fabricated type, anodised, ISI marked, complete all as specified and as directed. 744 Each
46 46 S&F 300 mm long mild steel sliding door bolts, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed, complete all as specified and as directed. 169 Each
47 47 S&F mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & as directed. 103 Each
48 48 S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150mm, fixed in floor, complete all as specified and as directed. 294 Each
49 49 S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified & directed. 944 Each
50 50 S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished, complete all as specified & directed. 800 Each
51 51 S&F Telescopic Channels 20 inch long with & including all necessary accessories, powder coated iron in Nickel / Silver / Black colour as approved by GE, superior quality, complete all as specified & as directed.\nMake : GODREJ / HETTICH / EBCO 600 Pair
52 52 S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples, fixed in repairs, complete all as specified & as directed. 130 Sqm
53 53 S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. 537.5 Sqm
54 54 S&F in repairs powder coated mild steel drapery rod of 25 mm inner dia & 1.6mm wall thickness (in lengths as directed) of approved colour/finish with & including sockets & decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam, including PVC curtain rings of matching colour @ 10cm C/C, complete all as specified & as directed. 384 RM
55 55 S&F in repairs aluminium powder coated (of approved colour/finish) brackets with sockets & decorative finials, suitable for 20mm bore drapery rod, fixed with PVC rawl plug & steel screws on walls/beam, complete all as specified & as directed. 576 Pair
56 56 S&F in repairs aluminium powder coated drapery rod of 20mm inner dia & 1.5mm wall thickness (in lengths as directed) of approved colour/finish complete all as specified & as directed. 642 RM
57 57 S&F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Grade E-165 (Fe 290), complete all as specified & as directed. 403.2 Kg
58 58 S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks, cooler stand and similar work including welding conforming to Grade E-165 (Fe 290), complete all as specified & as directed. 4822 Kg
59 59 M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed. 890.7 Kg
60 60 M&L for mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed. 392.5 Kg
61 61 S&F factory made pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, including making good the disturbed surfaces of wall etc in CM 1:4, complete as specified & as directed. 255 RM
62 62 S&F factory made pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, made out of mild steel sheet of 1.25 mm thickness, including making good the disturbed surfaces of wall etc in CM 1:4, complete as specified & as directed. 433.5 RM
63 63 S&F aluminium frame powder coated of any colour as approved (Thickness of powder coating not less than 50 micron) for doors, windows, ventilators, partitions, with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed. 7329.7 Kg
64 64 S&F aluminium window and ventilator shutters, powder coated of any colour as approved (Thickness of powder coating not less than 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.), complete all as specified & as directed. 984.4 Sqm
65 65 Supply and fixing mild steel cupboard shutter with frame, Godrej Pattern, made out of 22 guage mild steel sheet including superior quality chromium plated MS handle with proper locking arrangement (brass mortice lock, vertical type, size 65mm, 4 Levers with escutcheon plates & two keys) with & including two coats of spray painting with synthetic enamel paint of approved tint over a coat of red oxide primer including fixing with 6 Nos 12mm dia bolt 150 mm long grouted in brick wall/concrete including making good the disturbed surfaces as original complete all as specified and as directed.\nNote :- The measurement for payment purpose shall be taken of flat area of front elevation and not girthwise. No other allowance for sides, folded portion, etc shall be admissible. The quoted rate shall be deemed to include this provision. 72 Sqm
66 66 Dismantling of brick tiles or terracing tiles single layer on roofs, complete all as specified and as directed.\nNote : Tiles shall be dismantled carefully and stacked properly including segregating the serviceable & unserviceable tiles as directed. Serviceable tiles shall be reused under the respective item of this Schedule. 578.5 Sqm
67 67 Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and removing of demolished material to a distance exc 250 metre but not exc 500 metre upto the location as decided by GE, complete all as specified and as directed. 57.8 Cum
68 68 M&L for 40mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring, leveling course over roof and similar works, top surface finished fair & even, complete all as specified & as directed. 578.5 Sqm
69 69 M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminous primer @ 0.40 litre/sqm and provide a layer of APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick, reinforced with polyester non woven fabric (weighing not less than 150 gms/sqm) laid on primed surface complete all as described in Para 11.44.5 of SSR Part-I, complete all as specified and as directed. \nNote : The net area of water proofing treatment shall be measured without any extra allowance for laps. 578.5 Sqm
70 70 M&L for 40mm thick burnt clay brick tiles, joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound @ 3% by weight of cement, laid on roof over & including 15 mm thick cement mortar (1:6) bedding, complete all as specified & as directed. 173.5 Sqm
71 71 All as per serial item No. 70.00 here-in-before but except brick tiles.\nNote : Old serviceable brick tiles retrieved from serial item No 66.00 here-in-before shall be used under this item. 405 Sqm
72 72 M&L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls in Sunken portion, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified.\nNote : Supply only integral liquid water proofing compound shall be measured and paid for separately. \n 635.4 Sqm
73 73 M&L for removal of loose concrete and cleaning the surfaces and filling the cracks with Polymer modified mortar using Dr Fixit Pidicrete URP or other equivalent product as approved by GE and thereafter applying two coats of Dr Fixit Bathseal WPC or other equivalent product as approved by GE in Sunken areas complete all as per manufacturer’s instructions, specified & directed.\nNote : Where contractor desire to use equivalent product of Dr Fixit Pidicrete URP and Dr Fixit Bathseal WPC, he shall submit the technical literature of equivalent products to establish the equivalency of products to the entire satisfaction of GE and both products shall be of same manufacturer as approved by the GE. 635.4 Sqm
74 74 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified & as directed. 3195.5 Sqm
75 75 M&L for 75mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even, complete all as specified and as directed. 50 Sqm
76 76 M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded crushed stone aggregate as in flooring, leveling course, etc, surface finished fair and even, complete all as specified and as directed. 1045 Sqm
77 77 M&L for machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 20mm thick in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. 464.2 Sqm
78 78 M&L for machine cut Kota stone slab 20 to 25mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. 189.7 Sqm
79 79 M&L for 18 to 20mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and polished) with true & uniform joints as in steps, jambs, pillars, window cills, cooking platforms & like and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 20mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm complete all as specified & as directed. 344.3 Sqm
80 80 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified & as directed. 353.9 RM
81 81 M&L for non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed. 1807 Sqm
82 82 M&L for vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed. 2383.5 Sqm
83 83 M&L for glazed ceramic tiles (coloured) 7mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e 300mm x 450mm or as directed), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed. 4130.6 Sqm
84 84 M&L for non skid ceramic tiles (coloured) 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed. 121.8 Sqm
85 85 M&L for vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4, size of each tile 595mm x 100mm or size as directed by Engineer-in-Charge to match the size of vitrified tiles provided in floor under respective item in this Schedule, complete all as specified and as directed. 238.3 Sqm
86 86 M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished even and smooth without using extra cement complete all as specified. \nNote :- Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).\n 1275 Sqm
87 87 M&L for factory made 60mm thick machine pressed precast cement concrete coloured designer polished (reflecting type) interlocking paver blocks of Grade M-35 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment with coloured top casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & as directed.\nNote : Shape & colour of paver blocks shall be as approved by the GE. 50 Sqm
88 88 M&L for precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in kerb block (factory casted) with plain fair faces, including weathering, slightly rounded or chamfered angle throating, with plain or interlocking joints and setting in cement mortar 1:4, complete all as specified & as directed. 4.59 Cum
89 89 M&L for taking down / dismantling ceiling plaster, cutting surface in square or rectangular pattern and removing loose material all around the exposed reinforcement, cleaning the surfaces with wire brush, cutting down old rusted & damaged steel reinforcement, fixing hard drawn steel wire fabric, weight not exc 4 Kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia or welded to exposed reinforcement, applying the cement concrete rich mix 1:1½:3 using 6mm stone aggregate, making the surface level, curing for 7 days and ceiling plaster in cement mortar 1:3 with surfaces finished even & smooth without using extra cement, complete all as specified and as directed.\nNote : Hard drawn steel wire fabric shall be measured and paid for separately as “Supply only” under relevant item of this Schedule. 200 Sqm
90 90 Supply only hard drawn steel wire fabric, weight not exc 4 Kg per sqm, complete all as specified & as directed. 400 Kg
91 91 M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified & as directed.\n 1641.8 Sqm
92 92 M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified & directed. 965.5 Sqm
93 93 M&L for 15mm thick rendering in two layer on fair faces of brick masonry or concrete surfaces of walls consisting of 1st layer of 10mm thick plaster in CM 1:4 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4, 2nd layer mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished fair & even, complete, all as specified and directed.\nNote : - Supply only integral liquid water proofing compound shall be measured and paid for separately. 2470 Sqm
94 94 M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement : 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified & as directed. 390 Sqm
95 95 M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and directed.\nNote : Supply only integral liquid water proofing compound shall be measured and paid for separately. 90 Sqm
96 96 M&L for preparation of old surfaces (plastered or unplastered) of ceilings including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coats of white wash complete all as specified & as directed. 4429.3 Sqm
97 97 M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified & as directed. 1165.5 Sqm
98 98 M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 3mm thick white wall care putty complete all as specified & as directed. 1641.8 Sqm
99 99 M&L for complete removal of existing treatment by mechanical equipments like electric wall sander including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint using rollers over a coat of primer over & including 3mm thick white wall care putty on walls complete all as specified & as directed. 11696 Sqm
100 100 M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed. 2470 Sqm
101 101 M&L for preparation of newly plastered surfaces of wall finished to dry dash or rough cast and applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed. 390 Sqm
102 102 M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint on walls complete all as specified and as directed. 7400 Sqm
103 103 S&F 4mm thick figured glass pin head type in square not exc 0.5 sqm in each pane complete all as specified & as directed. 75.8 Sqm
104 104 S&F plain sheet glass 5.50 mm thick selected quality in required sizes, not exc 0.5 sqm in each pane, complete all as specified and as directed. 450.7 Sqm
105 105 M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed. 1805.1 Sqm
106 106 M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed. 898.8 Sqm
107 107 M&L for preparation of new surfaces of wood or wood based materials of any description not exc. 10 cm in width or girth when unconnected with other painting or when painted in a different tint and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed. 66.6 10 RM
108 108 M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed. 248 Sqm
109 109 M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of red oxide, zinc chrome primer complete all as specified & as directed. 958 Sqm
110 110 Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 15mm bore complete all as specified and as directed. 936 RM
111 111 M&L for galvanized steel water tubing medium grade (ISI marked) of 15mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed. 655.2 RM
112 112 Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 15mm bore obtained serviceable vide serial item No. 110.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed.\nNote : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used. 280.8 RM
113 113 Dismantling carefully and taking up or down existing unserviceable/serviceable steel water tubing and connections of 20mm bore complete all as specified and as directed. 936 RM
114 114 M&L for galvanized steel water tubing medium grade (ISI marked) of 20mm bore with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed. 655.2 RM
115 115 Fixing/Laying only, jointing and testing old serviceable galvanized steel water tubing medium grade of 20mm bore obtained serviceable vide serial item No. 113.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings and fixed to walls and ceilings or laid in floors in new or old position complete all as specified and as directed.\nNote : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used. 280.8 RM
116 116 Disconnecting existing serviceable rotational moulded polyethylene water storage tank, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of capacity exc 500 litres & not exc 1000 litres including cleaning & removing all scale & dirt etc from tank and from mouths of circulating pipes, etc, cleaning tank with fresh water and bleaching powder, complete all as specified and as directed. 12 Each Job
117 117 Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top), hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed. 22 Each Job
118 118 Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top), hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed. 10 Each Job
119 119 S&F in repairs Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20mm bore (minimum weight 210 gms) complete all as specified and as directed. 32 Each
120 120 S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, white, size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, complete all as specified and as directed. 36 Each Job
121 121 S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, complete all as specified & as directed. 72 Each Job
122 122 S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 32 mm dia flush pipe of polyethylene of low or high density or PVC, connected to water closet, complete all as specified & as directed. 108 Each Job
123 123 S&F in repairs vitreous china wash basin, angle back, size 600x480mm, white, with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed. 72 Each Job
124 124 S&F in repairs vitreous china wash basin, white, flat back, size 450x300mm, with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed. 36 Each Job
125 125 S&F sink with drainage board made of stainless steel 1mm thick for Kitchen with plugs, washers and wastes, including fixing with cast iron cantilever brackets, bedding in cement mortar on to brick wall, connecting union to pipe, overall minimum size 915mm x 460mm with bowl size 410mm x 330mm x 160mm including 40mm dia waste pipe of polythelene of low or high density, 40mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, making holes in walls for brackets and fixed in CM 1:3 or PCC 1:2:4 type B0, complete all as specified and as directed including taking down old unserviceable sink with fittings. 72 Each Job
126 126 S&F in repairs stainless steel Kitchen plate rack of overall minimum size 750mm x 600mm and 250mm deep, made out of selected quality 0.63mm thick stainless steel sheet, with partitions for small/large plates, hooks etc, shape & design as approved by GE, fixed with rawl plug and brass screws, complete all as specified and as directed. 76 Each
127 127 S&F in repairs PVC connection 450 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified & as directed. 216 Each
128 128 S&F in repairs 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes, complete all as specified & as directed. 108 Each
129 129 S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule, including CP brass wall flange, complete all as specified & as directed. \nMake :- Cat Part No. “CON-047KN” of make “Jaquar” or equivalent in makes mentioned in Appendix 'B' here-in-after. 144 Each
130 130 S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule, including CP brass wall flange, complete all as specified & as directed. 180 Each
131 131 S&F in repairs 15mm bore Stop valve, fancy type with long shank and cup (concealed type) of cast copper alloy chromium plated, screwed down, high pressure with capstan heads, screwed both ends for iron pipe or for union complete all as specified & as directed. 36 Each
132 132 S&F in repairs wall mixer, non telephonic shower arrangement, brass, chromium plated, fancy type, handles with lettered 'hot' and 'cold', screwed down high pressure, including CP brass wall flanges and connecting legs, screwed for 15mm bore pipe connection, complete all as specified as directed.\nMake :- Cat Part No. “FLR-5273UPR” of make “Jaquar” or equivalent in makes mentioned in Appendix 'B' here-in-after. 72 Each
133 133 S&F in repairs 15mm bore Angle stop valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure with capstan head, screwed both ends for iron pipe or for union, CP brass adjustable wall flange, complete all as specified & as directed.\nMake :- Cat Part No. “ARI-39053” of make “Jaquar” or equivalent in makes mentioned in Appendix 'B' here-in-after. 396 Each
134 134 S&F in repairs 15mm bore Angle stop valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure with capstan head, screwed both ends for iron pipe or for union, including CP brass wall flange, complete all as specified & as directed. 144 Each
135 135 S&F in repairs 600mm x 450mm looking mirror of selected quality glass not less than 5.5mm thick, mounted on 6mm thick AC building board or commercial plywood including aluminium framing and fixed to PVC rawl plugs with chromium plated brass screws and cup washers complete all as specified & as directed. 72 Each
136 136 S&F in repair bathroom Mirror cabinet (PTMT) of size 450mm x 350mm (with inside partitions) with 5mm thick high quality mirror, seamless finish, light weight, high strength, fixed on wall with cadmium plated brass screws, complete all as specified & as directed.\nMake :- Cat Part No. “557” of make “Prayag” or equivalent in makes mentioned in Appendix 'B' here-in-after. 72 Each
137 137 S&F in repairs brass chromium plated Health Faucet with 8mm dia & 1.20m long stainless steel braided flexible tube and wall hook suitable for fixing to supply pipe of 15mm bore complete all as specified and as directed.\nMake :- Cat Part No. “ALD-573” of make “Jaquar” or equivalent in makes mentioned in Appendix 'B' here-in-after. 72 Each
138 138 S&F in repairs Toilet paper holder, brass, chromium plated, heavy duty, fixed with brass screw complete all as specified and as directed.\nMake :- Cat Part No. “ACN-1153N” of make “Jaquar” or equivalent in makes mentioned in Appendix 'B' here-in-after. 72 Each
139 139 S&F in repairs shower arm 15 mm bore, 195 mm long with bend of 45 degree with flange of PTMT any colour (minimum weight 40 gms), complete all as specified & as directed. 108 Each
140 140 S&F in repairs Shower rose, round type, brass, chromium plated, long body, fancy type, 125 mm dia, fixing to pipe of 15mm bore or union complete all as specified and as directed. 72 Each
141 141 S&F in repairs Shower rose, round type, brass, chromium plated, 125 mm dia, with swivel joint, fixing to pipe of 15mm bore or union complete all as specified and as directed. 36 Each
142 142 S&F in repairs Soap dish, brass, chromium plated, heavy duty, fixed to wall with plugs with brass cadmium plated screws, complete all as specified and as directed. 144 Each
143 143 S&F in repairs tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges, fixed to PVC rawl plugs with chromium plated brass screws, complete all as specified and as directed. 72 Each
144 144 Dismantling of cast iron drain pipe of 100mm bore, jointed in CM and taking out of trenches or floors, if required, complete all as specified & as directed.\nNote :- Excavation & earthwork shall be measured and paid separately. 522 RM
145 145 Supply and fixing 100 mm bore cast iron, sand cast, soil, waste & vent pipes in any length with or without ears, ISI marked, fixed with cement joints, laid in trenches or floors, complete all as specified and as directed. 140.4 RM
146 146 Supply and fixing 100 mm bore cast iron, sand cast, soil, waste & vent pipes in any length with or without ears, ISI marked, fixed with cement joints, fixed to walls, complete all as specified and as directed. 381.6 RM
147 147 Dismantling of cast iron drain pipe of 75mm bore, jointed in CM and taking out of trenches or floors, if required, complete all as specified & as directed.\nNote :- Excavation & earthwork shall be measured and paid separately. 690 RM
148 148 Supply and fixing 75 mm bore cast iron, sand cast, soil, waste & vent pipes in any length with or without ears, ISI marked, fixed with cement joints, laid in trenches or floors, complete all as specified and as directed. 149.4 RM
149 149 Supply and fixing 75 mm bore cast iron, sand cast, soil, waste & vent pipes in any length with or without ears, ISI marked, fixed with cement joints, fixed to walls, complete all as specified and as directed. 540.6 RM
150 150 S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 100mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed. 112 Each
151 151 S&F stack clamp made out of MS flat 50mm x 5mm and 16 mm dia round iron stays, including bolts & nuts, securing ends of stays to walls or roof for 75mm bore pipe including two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete all as specified & as directed. 62 Each
152 152 S&F in repairs 100mm bore cast iron branch piece, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified & as directed. 90 Each
153 153 S&F in repairs 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified & as directed. 180 Each
154 154 S&F in repairs 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified & as directed. 216 Each
155 155 S&F in repairs cast iron cowl for 75 mm bore CI pipe complete all as specified & as directed. 54 Each
156 156 S&F in repairs cast iron Trap ‘P’ or ‘S’ of 100 mm bore complete all as specified & as directed. 108 Each
157 157 S&F in repairs cast iron Nahani trap of 75 mm bore, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4), complete all as specified & as directed. 192 Each
158 158 S&F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25 gms) complete all as specified & as directed. 192 Each
159 159 S&F in repairs 32mm dia waste pipe of polythelene of low density for WHB, sink, etc, complete all as specified and as directed. 180 Each
160 160 Demolition and breaking up drain pipes 100mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar or taking down 110m bore PVC (SWR) pipes, complete all as specified and as directed. 495 RM
161 161 S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls complete all as specified & as directed. 495 RM
162 162 S&F in repairs 110mm bore PVC (SWR) bend, any radius complete all as specified & as directed. 180 Each
163 163 Demolition and breaking up 150mm bore SGSW/RCC/AC drain pipes set in cement mortar including PCC haunching and bedding and removal of demolished material to a distance exc 250m but not exc 500m complete all as specified and as directed. 75 RM
164 164 S&F salt glazed stone ware drain pipes of 150mm bore, Class ‘SP 2’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified & as directed. 75 RM
165 165 M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and as directed. 75 RM
166 166 Taking down carefully existing unserviceable/perished surface conduit/ concealed conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed. 3840 Per Point
167 167 M&L for Modular point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular switches, sockets, regulators etc with and including modular cover plates with frame of requisite module, complete all as specified and as directed.\nNotes : (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for modular metal flush boxes of requisite module and modular cover plates with frame of requisite module of colour as approved by GE. 2734 Per Point
168 168 All as per serial item No. 167.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches. 388 Per Point
169 169 All as per serial item No. 167.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board. 388 Per Point
170 170 All as per serial item No. 167.00 here-in-before but for one light point controlled by two, two way switches. 46 Per Point
171 171 All as per serial item No. 167.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour. 548 Per Point
172 172 S&F Modular switch 1 way 6A, 1 module, complete all as specified and as directed. 2612 Each
173 173 S&F switch piano, flush type, single pole, one way, 6 Amp, ISI marked, complete all as specified and as directed. 678 Each
174 174 S&F Modular switch 2 way 6A, 1 module, complete all as specified and as directed. 74 Each
175 175 S&F switch piano, flush type, single pole, two way, 6 Amp, ISI marked, complete all as specified and as directed. 18 Each
176 176 S&F Modular Bell push 6A, 1 module, complete all as specified and as directed. 76 Each
177 177 S&F bell push, flush type, 6 Amp, ISI marked, complete all as specified and as directed. 36 Each
178 178 S&F Modular switch, 1 way 16 Amp, 1 module, complete all as specified and as directed. 400 Each
179 179 S&F Modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and as directed. 560 Each
180 180 S&F socket outlet, 3 pin (2 in 1, with 2 pin outlet also), 6 Amp, flush type, ISI marked, complete all as specified and as directed. 108 Each
181 181 S&F Modular Socket 6A/16A - 2/3 pin combined 2 module, complete all as specified and as directed. 400 Each
182 182 S&F switch socket combination, 2 in 1, 6 Amps, flush type, ISI marked, complete all as specified & as directed. 108 Each
183 183 S&F switch socket combination, 5 in 1, 6A/16A Amps, flush type, ISI marked, complete all as specified & as directed. 72 Each
184 184 S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed. 1548 Each
185 185 S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed. 900 Each
186 186 S&F Modular Fan step regulator, 120W - 2 module, complete all as specified and as directed. 240 Each
187 187 S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 150 Watt, 2 modules including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed. 84 Each
188 188 Supply and fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, complete all as specified and as directed. 112 Each
189 189 S&F in replacement LED Bulkhead fitting of 1X10 Watt 6500K complete with Standard profile linear LED lighting fixture with extruded polycarbonate environment friendly complete with all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to fitting connection etc with following specifications, complete all as specified and as directed :- \n(a) Lumen efficacy of system should be minimum 105 Lumen per watt. \n(b) Voltage operating range : 160 to 270 Volts\n(c) Temp operating range Minus 10°C to plus 50°C\n(d) Power factor : Minimum 0.95 \n(e) THD Max 10%\n(f) IP rating IP-65\n(g) CRCA pre coated housing \n(h) LED Driver of the make as of the luminaries. \n(j) LED Driver should be complete with all protections viz open / short circuit protection. Over voltage protection all as per standard design of manufacturer. \n(k) Surge protection device for 2.5 KV\n(l) CRI Minimum 80\nMake : Model “NJE-10-CDL” of M/S Crompton or equivalent model in any of makes as per Appendix ‘B’ in tender documents. 220 Each
190 190 S&F in replacement (including taking down old light fitting any type) LED batten fitting including T-8 Retro LED 1x20 Watt, 6000K, 4 feet complete with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly cover complete with connection with 2 core flexible copper cable 23/0.00076 from ceiling rose to fitting connection with following specifications, complete all as specified and as directed :- \n(a) Lumen efficacy of system should be minimum 105 Lumen per watt.\n(b) Voltage operating range : 160 to 270 volts\n(c) Temp operating range : Minus 10°C to Plus 50°C\n(d) Power factor : Minimum 0.95\n(e) THD : Max 10%. \n(f) IP rating : IP-20. \n(g) CRCA pre coated housing with two coloured plastic end caps.\n(h) LED Driver of the make as of the luminaire. \n(j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer.\n(k) Surge protection device for 2.5 KV. \n(l) CRI : Minimum 80\nMake: Model “LDL-20-WW” of M/S Crompton or equivalent model in any of makes as per Appendix ‘B’ in tender documents. 806 Each
191 191 S&F in replacement Four Star Rated LED lamp 9W LED B-22 base with following specifications, complete all as specified and as directed :-\n(a) Lumen efficacy of system should be minimum 105 Lumen per watt.\n(b) Voltage operating range : 160 to 270 Volts\n(c) Temp operating range : Minus 10°C to Plus 50°C\n(d) Power factor : Minimum 0.90\n(e) CRI : Min 80\nMake: Model “LED 9W-B22-WW” of M/S Crompton or equivalent model in any of makes as per Appendix ‘B’ in tender documents. 900 Each
192 192 S&F in replacement LED mini mirror fitting of minimum and including lamp of 1x10 Watt, 6000K, 2 feet complete with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly cover including connection with 2 core flexible copper cable 23/0.00076 from ceiling rose to fitting connection with following specification, complete all as specified and as directed :- \n(a) Lumen efficacy of system should be minimum 105 Lumen per watt.\n(b) Voltage operating range : 160 to 270 Volts\n(c) Temp operating range : Minus 10°C to Plus 50°C\n(d) Power factor : Minimum 0.95\n(e) THD : Max 10%. \n(f) IP rating : IP-20. \n(g) CRCA pre coated housing.\n(h) LED Driver of the make as of the luminaire. \n(j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer.\n(k) Surge protection device for 2.5 KV. \n(l) CRI : Minimum 80\nMake: Model “LDL-10-WW” of M/S Crompton or equivalent model in any of makes as per Appendix ‘B’ in tender documents. 152 Each
193 193 Supply, installation, commissioning & testing Light Emitting Diode (LED) based street/security light fitting, 25 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 2500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK = 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), fixed in repairs, complete all as specified and as directed. 38 Each
194 193.01 NOTES FOR LED LIGHT FITTINGS & BULBS :\n(i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13.\n(ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80.\n(iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :-\n(a) Manufacturing defects.\n(b) Failure due to mechanical and electrical impact.\n(c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
195 194 Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, fixed in repairs, complete all as specified and as directed. 38 Each Job
196 195 Supply & fixing Exhaust fan of 300mm sweep, heavy duty, double ball bearing, copper wound, steel body, 900 RPM, Single Phase 230 Volt, 50 Hz AC supply complete with blades, frame and louver shutter and connecting up with & including three core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2 mm drawn into & including flexible PVC conduit and fixed by using 4 Nos, 100mm long 8mm dia bolt nuts and washers and grouted in wall in CM (1:3) with and including making suitable opening in existing wall complete all as specified & as directed 228 Each
197 196 Supply, installation & testing electric Geyser (water storage type) of capacity 25 litre, vertical mounting type, glass lined inner tank, rust proof outer body, 2 KW heating element, suitable for 230V Single Phase 50 Hz AC supply, 5 Star rating, energy efficient, 8 Kg/sqcm pressure withstanding capacity, Class I, ISI marked, with & including Thermostat with Thermal Cutout, heating indicator, Multi functional valve (acts as pressure release valve, non-return valve, expansion valve and vacuum release valve), fixed all as per manufacturer’s instructions, fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 12mm dia 200mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface in CM (1:3), complete all as specified & as directed. 36 Each
198 197 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 230 Volt, 10 kA, ‘C’ Curve, ISI marked, fixed in repairs, complete all as specified and as directed. 76 Each
199 198 S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated copper bus bar, 8 way, 240 Volts, flushed in wall, fixed in repairs, complete all as specified and as directed.\nNote : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. 53 Each
200 199 S&F sheet metal enclosure, double door type, suitable for fixing MCBs, TPN with 200 Amps rated copper bus bar, 4 way, 415 Volts, flushed in wall, fixed in repairs, complete all as specified and as directed.\nNote : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. 37 Each
201 200 S&F Isolator 100 Amps TPN suitable for 415 Volt AC supply, fixed in repairs, complete all as specified and as directed. 37 Each
202 201 S&F MCB, 63 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, ISI marked, fixed in repairs, complete all as specified and as directed. 9 Each
203 202 S&F MCB, 40 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, ISI marked, fixed in repairs, complete all as specified and as directed. 44 Each
204 203 S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, ISI marked, fixed in repairs, complete all as specified and as directed. 714 Each
205 204 M&L for disconnecting & taking down carefully existing functional electronic energy meters (Single Phase - 04 Nos) from the multi-meter box/panel, dismantling & taking down old unserviceable meter box/panel of any size & type and supply & fixing new SMC multi meter box of size 650mm x 450mm x 150mm for mounting of electronic energy meters (Single Phase 04 Nos), single hinged door, shockproof, rustproof, cable entry from bottom, 100% weatherproof, pole mounting arrangement, tamper proof, pilferage proof, fire retardant Class FV-0 as per IS-11731 Part-II or V-0 as per UL-94, high heat distortion temperature (200°C as per IS-10192) and re-fixing the electronic energy meters (Single Phase - 04 Nos) & making connections complete all as specified & as directed. \nMake :- Sintex (Product Code No. GSMB-6545) or equivalent in HPL / Secure / Indo Asian / Crompton Greaves. 9 Each Job
206 205 Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.\nNote : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. 83 Each Set
207 206 M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed.\nNotes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item. 900 RM
208 207 Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable of any size complete all as specified and as directed.\nNote :-\n(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.\n(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. 500 RM
209 208 Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable of any size complete all as specified and as directed.\nNote :-\n(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.\n(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions. 600 RM
210 209 M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed.\nNotes :-\n(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used.\n(ii) For the purpose of payment, only punned thickness shall be measured. 80 Cum
211 210 M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed. 8 Per 1000 Nos
212 211 M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete including taking down old unserviceable pipe of any size with clamps. \nNote :- Excavation & earthwork shall be measured & paid for separately. 200 RM