| 1 | 1 | M&L for taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer-in-Charge. | | 560 | Sqm |
|---|
| 2 | 2 | M&L for demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches,pillars,etc,but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engineer-in-Charge. | | 6 | Cum |
|---|
| 3 | 3 | M&L for demolition of cement concrete (un reinforced) in ground floor and paving n. exe 15 cm thickness (below or above ground level), complete all as specified and directed by Engineer-in-Charge. | | 7 | Cum |
|---|
| 4 | 4 | M&L for demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided and removing the demolished material from the site to a distance n. exc 500M and depositing where directed by Engineer-in-Charge. | | 8 | Cum |
|---|
| 5 | 5 | M&L for demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided and removing the demolished material from site, complete all as specified and directed by Engineer-in-Charge. | | 3 | Cum |
|---|
| 6 | 6 | M&L for dismantling floor, hearth or wall tiling including Cement Mortar bedding(but not backing coat), complete all as specified and directed by Engineer-in-Charge. | | 269 | Sqm |
|---|
| 7 | 7 | M&L for dismantling wall and ceiling boards, fibre pulp insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets,all as specified. | | 60 | Sqm |
|---|
| 8 | 8 | M&L for taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm & 20 mm dia complete all as specified and directed by Engineer-in-Charge. | | 140 | Rm |
|---|
| 9 | 9 | M&L for dismantling asbestos cement/any type of sheet (corrugated, semicorrugated, etc) sheets in roof coverings complete all as specified and directed by Engineer-in-Charge. | | 380 | Sqm |
|---|
| 10 | 10 | M&L for dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed by Engineer-in-Charge. | | 4.5 | Qtl |
|---|
| 11 | 11 | M&L for dismantling cast iron work of any description etc complete all as specified and directed by Engineer-in-Charge. | | 1.5 | Qtl |
|---|
| 12 | 12 | M&L for taking down Chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.50sqm each and removing from site complete all as specified and directed by Engineer-in-Charge. | | 10 | Each |
|---|
| 13 | 13 | M&L for taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5sqm but not exc 4 sqm each and removing from site complete all as specified and directed by Engineer-in-Charge. | | 12 | Each |
|---|
| 14 | 14 | M&L for dismantling of AC/PVC pipe with all fittings and fixing acessories, any dia and any location complete all as specified and directed by Engineer-in-Charge. | | 60 | RM |
|---|
| 15 | 15 | M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips, complete all as specified and as directed by Engineer-in-Charge. | | 30 | Sqm |
|---|
| 16 | 16 | M&L for brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.. | | 4 | Cum |
|---|
| 17 | 17 | M&L for brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified and directed by Engineer-in-Charge. | | 2 | Cum |
|---|
| 18 | 18 | M&L for brick work with sub class ‘B’ bricks (old size), straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified and directed by Engineer-in-Charge. | | 5 | Sqm |
|---|
| 19 | 19 | M&L for broken stone or boulders hardcore of gauge exc. 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge. | | 2 | Cum |
|---|
| 20 | 20 | M&L for precast reinforced cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in cover slabs ( for manholes etc). and similar articles with plain faces, set in cement mortar 1:4, complete all as specified and directed by Engr-in-Charge.\nNOTE:-Reinforced measured and paid separataly in respective item. | | 2 | Cum |
|---|
| 21 | 21 | M&L for reinforced cement concrete 1: 2 : 4 type B-1 using 20mm graded crushed stone aggregate as in chajjas complete all as specified and directed by Engineer-in-Charge. | | 1 | Cum |
|---|
| 22 | 22 | M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. | | 7 | Cum |
|---|
| 23 | 23 | M&L for plain cement concrete (1:3:6) type C-0 using 12.5mm graded crushed stone aggregate for filling in the pressed steel door/hold fast, complete all as specified and directed by Engineer-in-Charge. | | 0.5 | Cum |
|---|
| 24 | 24 | S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified. | | 20 | Sqm |
|---|
| 25 | 25 | S&F4 mm thick figured glass, pin head type and glazing with oil putty in squares in exc 0.5 sq.m in each pane complete all as specified and directed by Engineer-in-Charge. | | 10 | Sqm |
|---|
| 26 | 26 | S&F Factory made solid pannel PVC door shutter 30 mm thick ( style) consisting of frame made out of M S tubes for top and bottom rails. M S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail ; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement , supplying and fixing in the frame at site as per specification and drawing , complete all as specified in SSR and as directed. | | 15 | Sqm |
|---|
| 27 | 27 | M&L for solid PVC Door frame of size 50mmx47mm made out of 5mm plain color PVC sheet reinforced with MS Square tube, supply and fixing in opening as per specification and drawings and incluiding making good disturbed surfaces complete all as specified and directed. | | 42 | RM |
|---|
| 28 | 28 | M&L for 35mm thick factory made plain framed, panelled shutter (two panel), 2nd class hard wood rail and style with lock rail and panel of 9 mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003,(Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer In Charge. | | 12 | Sqm |
|---|
| 29 | 29 | All as per Serial Item 28 here-in-before but without interlocking rail and with one panel only ditto, complete all as specified and directed by Engineer-in-Charge. | | 10 | Sqm |
|---|
| 30 | 30 | M&L for 125 mm Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed by Engr-in-Charge. | | 14 | Each |
|---|
| 31 | 31 | M&L for aluminium alloy, anodized, sliding door bolts with hasp staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium, 300 mm long and dia of rod not less than 16 mm, ISI marked, complete all as specified and directed by Engineer-in-Charge.\n | | 15 | Each |
|---|
| 32 | 32 | M&L for 150 mm size aluminium handles cast type anodised, complete all as specified and directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 33 | 33 | M&L for 150mm long aluminium anodised, barrel tower bolts extruded section, complete all as specified and directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 34 | 34 | M&L for mild steel barrel tower bolts, stove enamelled black with 100 mm long bright bolt, complete all as specified and directed by Engineer-in-Charge. | | 10 | Each |
|---|
| 35 | 35 | Mild steel cold rolled butt hinges medium weight 100 mm long fixed to pressed steel/angle iron frames by welding, complete all as specified and directed by Engineer-in-Charge. | | 30 | Each |
|---|
| 36 | 36 | M&L for steel windows with side hung shutters including box type hinges, steel handle, mild steel ISI marked tower bolt 100 mm size (minimum 2 for each shutter), and steel peg stay, complete with glazing bars, dovetailed or welded with one shop coat of zinc chromate primer, complete all as specified. | | 3 | Sqm |
|---|
| 37 | 37 | M&L for steel windows with side hung shutters including box type hinges, steel handle, mild steel ISI marked tower bolt 100 mm size (minimum 2 for each shutter), and steel peg stay, complete without glazing bars, dovetailed or welded with one shop coat of zinc chromate primer, complete all as specified. | | 5 | Sqm |
|---|
| 38 | 38 | M&L for pressed steel frames, conforming to IS, having profile 105 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., complete, as specified, supplied and fixed with one shop coat of zinc chromate primer, complete all as specified and directed by Engineer-in-Charge. | | 18 | RM |
|---|
| 39 | 39 | M&L for pressed steel frames, conforming to IS, having profile 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., complete, as specified, supplied and fixed with one shop coat of zinc chromate primer, complete all as specified and directed by Engineer-in-Charge. | | 20 | RM |
|---|
| 40 | 40 | M&L for mild steel TMT bars 6 to 8mm dia ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clips, complete all as specified and directed by the Engineer-in-Charge. | | 95 | Kg |
|---|
| 41 | 41 | M&L for 6mm thick non asbestos cement corrugated or semi corrugated sheets in roof, walls etc fixed with 'L' type or 'J' type hoks or cranked hook bolts complete all as specified. | | 95 | Sqm |
|---|
| 42 | 42 | All as per item No 41 but except sheet complete all as specified and directed by Engineer-in-Charge. | | 30 | Sqm |
|---|
| 43 | 43 | Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed by Engineer-in-Charge. | | 200 | Kg |
|---|
| 44 | 44 | M&L for roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engineer-in-Charge. | | 250 | Kg |
|---|
| 45 | 45 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge. | | 20 | Sqm |
|---|
| 46 | 46 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and directed by Engineer-in-Charge. | | 155 | Sqm |
|---|
| 47 | 47 | M&L for 0.63mm thk Galvanised, corrugated mild steel sheeting with two corrugations side lap,fixed with L-type or J-type or\ncranked hook bolts in lieu of screws, in roofs, wallsetc. with grade of zinccoating 275 complete all as specified and directed by Engineer-in-Charge. | | 40 | Sqm |
|---|
| 48 | 48 | M&L for 0.63 mm thk Plain, galvanised, mildsteel sheeting, in ridges,hips, valley gutters, drip and straight flashings\n(length and girth as fixed) with grade of zinc coating 275complete all as specified and directed by Engineer-in-Charge. | | 10 | Sqm |
|---|
| 49 | 49 | M&L for 2mm thick Fibre glass reinforced translucent corrugated\nsheeting with two corrugations side lap fixed with L- type or J-type or cranked hook bolts in leiu of screws in roof, wallcomplete all as specified and directed by Engineer-in-Charge. | | 30 | Sqm |
|---|
| 50 | 50 | M&L for 6mm thick non asbestos cement two pieces adjustable plain wing ridge for corrugated or semi corrugated sheets fixed with 'L' type or 'J' type or cranked hook bolts complete all as specified and directed by Engineer-in-Charge. | | 18 | RM |
|---|
| 51 | 51 | M&L for mild steel conforming to Fe-290 Gde E-165 Framed work such as grills, grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters,walk ways, railings and similar work including dismantling of existing steel, complete all as specified and directed by Engineer-in-Charge. | | 70 | Kg |
|---|
| 52 | 52 | M&L for stainless steel wire cloth,0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with Stainless steel wire staples fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 25 | Sqm |
|---|
| 53 | 53 | M&L for providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection even and smooth without using extra cement complete all as specified. | | 75 | Sqm |
|---|
| 54 | 54 | M&L for 25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded crushed stone aggregate, finished even and rough as in floors to received tiles, complete all as specified and directed by Engineer-in-Charge. | | 90 | Sqm |
|---|
| 55 | 55 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:4 , complete all as specified and directed by Engr-In-Charge | | 120 | Sqm |
|---|
| 56 | 56 | M&L for glazed ceramic tiles size 300 mm x 200 mm x 7to8mm thick on vertical surfaces such as skirting /dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete surfaces as backing coat complete all as specified and directed by Engineer-in-Charge. | | 59 | Sqm |
|---|
| 57 | 57 | M&L for glazed ceramic tiles size 450 mm x 300 mm x 7to8mm thick on vertical surfaces such as skirting /dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete surfaces as backing coat complete all as specified and directed by Engineer-in-Charge. | | 90 | Sqm |
|---|
| 58 | 58 | M&L for 15mm thick rendering on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge. | | 210 | Sqm |
|---|
| 59 | 59 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:4), including integral WPC by wt of cement as per manufacturer instruction (NOTE : Supply only WPC will be measured and paid for separately), complete all as specified and directed by Engr-in-charge. | | 325 | Sqm |
|---|
| 60 | 60 | M&L for rendering 5 mm thick on fair faces of concrete surfaces on ceiling,roof projection,chajja in cement mortar (1:3) finished even and smooth , complete all as specified and directed by Engineer-in-Charge. | | 25 | Sqm |
|---|
| 61 | 61 | M&L for treatment of sunken floor surfaces with 0.488 kg/Sqm first layer of slurry of cement mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer shall be allowed to be cured for 4 hours and then applying in second layer slurry of cement @ 0.242 Kg /Sqm mixed with acrylic based polymer based modified cementitiousc omposite compound @0.126 Kg/Sqm. This layer shall be allowed to be cured for 4 hours incl fixing of 32 mm dia GI spout pipe 450mm long including taking down the existing complete all as specified and directed by Engineer-in-Charge. | | 35 | Sqm |
|---|
| 62 | 62 | M&L for rendering 15 mm thick on fair faces of concrete surfaces, finished even and smooth (without using extra cement) in cement mortar (1:4) for roof treatment , complete all as specified and directed by Engr-in-charge. | | 175 | Sqm |
|---|
| 63 | 63 | M&L for preparing RCC roof slab top by wire brushing and cleaning the dust and forign material etc complete and applying a coat of hot blown bitumen 85/25 grade @ 1.2 Kg per Sqm over coat of bitumen primer @ 0.40 Ltrs/Sqm and there after laying of a layer of APP based polymenic membrane (five layered with centre core as 100microns, high molecular high density ployethlene film) minimum weighing 3 Kg/Sqm and reinforced with polyster non woen fabricd (wt not less than 150 gms/Sqm laid on bituminous surface by press application method with 75 mm side ov erlap and 100mm end overlap the membrane has to be laid with LPG torch application and overlaps sealed and finished neat, after taqht applying one coat of bitumen, 85/25 grade on top surface @ @ 1.20 kg/Sqm and blinded with premier dry sand @ 0.5 kg/Sqm dusted over bitumen coat including taking down the existing, complete all as specified and as directed.\nNote :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed by engaging local labour. | | 175 | Sqm |
|---|
| 64 | 64 | M&L for 25cmx25cmx22mm Thick Cement Concrete tiles with grey cement and no pigment , machine pressed, set jointed and pointed in neat cement slurry in floors, terece over and including 20mm thick bedding layer in CM 1:4. including taking down the existing complete all as specified and directed by Engr-in-charge. | | 50 | Sqm |
|---|
| 65 | 65 | Apply two coats of Aluminium paint on roof surface,complete all as specified and directed by Engr-in-charge. | | 125 | Sqm |
|---|
| 66 | 66 | M&L for two coat of Oil bound distemper including a coat of primer including preparation of newly plastered surfaces of wall complete all as specified and directed by Engineer-in-Charge. | | 210 | Sqm |
|---|
| 67 | 67 | M&L for two coat of cement base paint including preparation of newly plastered surfaces of wall complete all as specified and directed by Engineer-in-Charge. | | 325 | Sqm |
|---|
| 68 | 68 | Preparation of new wooden or untreated wood surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed by Engineer In Charge | | 47 | Sqm |
|---|
| 69 | 69 | Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over priprimed, complete all as specified and directed by Engineer-in-Charge. | | 8 | Sqm |
|---|
| 70 | 70 | M&L for vitreous china squatting pan, 'Orissa' pattern, size 580 x 440 mm white, with integral foot rests including replacement of 'P' or 'S' CI trap front or back excluding flushing cistern & flush pipe and lime concrete bedding and making good existing floor fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 71 | 71 | M&L for vitreous china European,Wash down water closet pan (Pedestal pattern), including Seat and cover but with recessed bottom excluding flushing cistern & flush pipe and lime concrete bedding and making good existing floor fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 72 | 72 | M&L for 10 ltrs PVC flushing cistern low level (white) with inlet, ball valve float and handle including PVC Connection and 32mm dia PVC long bend for squar pattern etc. set with concrete and making good to floor fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 8 | Each |
|---|
| 73 | 73 | M&L for plastic water closet seat, white/black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 4 | Each |
|---|
| 74 | 74 | M&L for vitreous china wash hand basin white, flat back of size 550mmx400mm including waste chain and plug and porcelain stopper but including brackets CP Waste coupling,15mm x450mm long PVC connection, 32 mm dia PVC waste pipeand all waste fitting etc fixed in repair , complete all as specified and directed by Engineer-in-Charge. | | 7 | Each |
|---|
| 75 | 75 | M&L for 20mm dia CP tubular towel rail 60 cm long incl bracket fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 15 | Each |
|---|
| 76 | 76 | M&L for rating square 150 mm size of PTMT (Minimum weight 100gms fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 10 | Each |
|---|
| 77 | 77 | M&L for cast copper alloy,chromium plated hand shower (health faucer) with 8mm dia, 1.0 meter long flexible tube and wall hook, fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 12 | Each |
|---|
| 78 | 78 | M&L for looking mirror of size 600x450mm with bevelled edges, fancy type, made of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 18 | Each |
|---|
| 79 | 79 | M&L for stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100/110mm bore pipe fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 80 | 80 | M&L for stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm bore pipe fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 81 | 81 | M&L for 75mm bore cast iron sand cast soil waste and vent pipe in any length with or without ears with cement joint fixed to walls with mild steel Clamp including takind down of existing pipe complete all as specified and directed by Engineer-in-Charge. | | 25 | RM |
|---|
| 82 | 82 | M&L for 100mm bore cast iron sand cast soil waste and vent pipe in any length with or without ears with cement joint fixed to walls with mild steel Clamp including takind down of existing pipe complete all as specified and directed by Engineer-in-Charge. | | 25 | RM |
|---|
| 83 | 83 | M&L for 100mm bore cast iron branch pieces, single, (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches suitable for cast iron soil waste discharge pipe fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 6 | Each |
|---|
| 84 | 84 | M&L for 75mm bore cast iron branch pieces, single, (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches suitable for cast iron soil waste discharge pipe fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 6 | Each |
|---|
| 85 | 85 | M&L for 100mm bore cast iron bend (any radius) with duck's foot or heel rest fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 6 | Each |
|---|
| 86 | 86 | M&L for 75mm bore cast iron bend (any radius) with duck's foot or heel rest fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 6 | Each |
|---|
| 87 | 87 | M&L for 100mm bore cast iron diminishing pieces/junction plain any radius fixed as reducer, suitable for CI spun pipes fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 8 | Each |
|---|
| 88 | 88 | M&L for 75mm bore cast iron diminishing pieces/junction plain any radius fixed as reducer, suitable for CI spun pipes fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 8 | Each |
|---|
| 89 | 89 | M&L for vitreous china urinal, half stall type,white with grating and union for discharge pipe (excluding flushing cistren, flush pipe and waste pipe) including CP Waste coupling, complete bedding urinal against wall in cement mortar 1:2 securing urinal to, plugs with and including 60mm long brass screws, pointing around urinal back in cement fixed in repair, complete all as specified and directed by Engineer-in-Charge, | | 3 | Each |
|---|
| 90 | 90 | M&L for urinals spreader of PTMT any colour for fixing with 15mm dia pipe (minium weight 60gms) fixed in repair, complete all as specified and directed by Engineer-in-Charge | | 3 | Each |
|---|
| 91 | 91 | M&L for 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed by Engineer-in-Charge. | | 60 | RM |
|---|
| 92 | 92 | M&L for 110mm bore PVC (SWR) bends/shoe any radius fixed in repair complete all as specified and directed by Engineer-in-Charge. | | 16 | Each |
|---|
| 93 | 93 | 75mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 1:2:4 of size 200mm x200mmx250mm, fixed in repair , complete all as specified and directed by Engineer-in-Charge. | | 6 | Each |
|---|
| 94 | 94 | M&L for 150 x 150mm size salt glazed stoneware gully traps, square or round mouthed type ‘P’ , fixed in repair , complete all as specified and directed by Engineer-in-Charge. | | 8 | Each |
|---|
| 95 | 95 | M&L for 100mm bore cast iron traps P or S fixed in repair , complete all as specified and directed by Engineer-in-Charge. | | 5 | Each |
|---|
| 96 | 96 | M&L for 300x300mm corner glass shelf with Chromium plated brackets fixed in repair , complete all as specified and directed by Engineer-in-Charge. | | 15 | Each |
|---|
| 97 | 97 | M&L for bib taps, brass, chromium plated, fancy type,with butterfly handle screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15mm fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 98 | 98 | M&L for angle valve/stop valve, brass, chromium plated, fancy type, with capstan head handle screwed down high pressure, including CP brass wall flanges; screwed for 15mm bore pipe connection fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 25 | Each |
|---|
| 99 | 99 | M&L for float valve 20 mm PTMT high pressure incl epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 20 | Each |
|---|
| 100 | 100 | M&L for pillar mixture with hot and cold provision chromium plated 15mm bore fancy type fixed in repair, complete all as specified and directed by Engineer-in-Charge. | | 8 | Each |
|---|
| 101 | 101 | S&F non asbestos fibre Cement board ceiling 4mm, thick in 600x600mm panel (Make-everest) designed ceiling conforming to IS-14862 type B category three incl snapgrid frame work, hold fast, suspenders complete all as specified and directed by Engineer-in-Charge. | | 60 | Sqm |
|---|
| 102 | 102 | S&F Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm complete all as specified and directed by Engineer-in-Charge. | | 50 | Rm |
|---|
| 103 | 103 | Description all as per item no 102 above but of 20mm bore complete all as specified and directed by Engineer-in-Charge. | | 40 | Rm |
|---|
| 104 | 104 | Fixing only steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia15 mm, all as specified. | | 30 | Rm |
|---|
| 105 | 105 | Description all as per item no 104 above but of 20 mm bore complete all as specified and directed by Engineer-in-Charge. | | 20 | Rm |
|---|
| 106 | 106 | S&F Rotational moulded PVC water tanks of Cap 1000 Ltrs cylindrical verticle with closed top hoisted and fixed in position all as spd in SSR Part incl fixing of 20mm PTMT float valve medium grade dismanteling of existing unserviceable water tanks and removal from site complete all as specified and directed by Engineer-in-Charge. | | 5 | Each |
|---|
| 107 | 107 | S&F Rotational moulded PVC water tanks of Cap 500 Ltrs cylindrical verticle with closed top hoisted and fixed in position all as spd in SSR Part incl fixing of 20mm PTMT float valve medium grade & dismanteling of existing unserviceable water tanks and removal from site complete all as specified and directed by Engineer-in-Charge. | | 3 | Each |
|---|
| 108 | 108 | S&F brass chromium plated shower rose 125mm dia complete all as specified and directed by Engineer-in-Charge. | | 10 | Each |
|---|