| 1 | SUB HEAD-I (EI work) 1. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(a). Group C |
| 2 | 2. Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | 3. Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | 4. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a). 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | (b). 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire |
| 6 | 5. Supplying and drawing of following size PVC insulated copper conductor cable in existing steel conduit etc as required.(a). 2 x1.5sqmm |
| 7 | (b). 3 x1.5sqmm |
| 8 | {c}. 4 x1.5sqmm |
| 9 | 6. Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
| 10 | 7. S/F of DP sheet steel enclosure on surface/ recess a/w 25/32 A 240 volt Ccurve DP MCB complete with connection, testing and commissioning etc. as reqd. (for AC point) |
| 11 | 8. Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(a). 4 way (4 + 12), Double door |
| 12 | 9. Supplying and fixing of 18 Watt LED tube light fitting i/c connection, testingetc. complete as required. |
| 13 | 10. Supply/ fixing of following faulty items in existing switch boards/ meter boards/ MCBDBs etc. i/c connection ,testingetc. complete as required.(a). 5 A switch |
| 14 | (b). 5 Amp 3pin Socket |
| 15 | {c}. 15 Amp Switch |
| 16 | (d). 15 Amp 6pin Socket |
| 17 | (e). Brass holder |
| 18 | (f). 63A kit kat fuse unit |
| 19 | (g). ceiling rose |
| 20 | (h). phenolic laminated round sheet 3\" |
| 21 | (i). 63 A four pole isolator |
| 22 | (j). 40 A DP Isolator |
| 23 | (k). MCB (6A to 32 A) |
| 24 | 11. Servicing / repairing of existingceiling fani/c dismantling & replacement of faulty accessories,reinstalling, connection and testing etc as reqd. (a). Ceiling fan rewinding |
| 25 | (b). Condensor for Ceiling fan |
| 26 | {c}. Bearing for ceiling fan |
| 27 | 12. Supplying and fixing of 2mm thick phenolic sheet on the existing switch board i/c cuttung etc. cpmplete as required. |
| 28 | 13. Supplying and fixing of 10 Watt LED bulb in the existing angle holder etc. complete as required |
| 29 | 14. Supplying and fixing of 7 Watt LED bulb in the existing angle holder etc. complete as required |
| 30 | 15. Supply/ replacement of 63 A ( L& T make FN 63) TPN switchi/c removal of existing switch , fixingof new switch, connection , testing etc. as complete as reqd. |
| 31 | 16. Supply/ replacement of 63 ATPNswitch with steel enclouseri/c removal of existing switch , fixingof new switch, connection , testing etc. as complete as reqd.(Havells/ HPL) |
| 32 | 17. Supply/ replacement of 63 Afour pole on load change over switch with steel enclouseri/c removal of existing switch , fixingof new switch, connection , testing etc. as complete as reqd.(HPL/ Havells) |
| 33 | 18. Repairing of existing compound light fitting i/c replacement of faulty holder , 20 watt LED bulb , fixing , connection and testing etc. complete as reqd. |
| 34 | 19. Replacementof faulty gatelight fitting i/c pdg. 10 watt LED bulb, fixing , connection and testing etc. complete as reqd. |
| 35 | 20. S/F of 15 watt LED street Light fitting i/c connection ,testing etc complete as reqd (Havells or ss make) |
| 36 | 21. S/F of 32mm GI steel pipe including bending suitable for fixing of Street light fitting i/c clamps etc completeas reqd. |
| 37 | 22. S/F of 1200 mm sweep ceiling fan i/c connection , testing etc as reqd. |
| 38 | 23. Re- fixingand redressof all cables & conduit pipes i/c pdg. suitable size saddles etc, as reqd. |
| 39 | 24. Laying of existing one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Up to 35 sq mm) |
| 40 | 25. Laying and fixing of existing one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.(Up to 35 sq mm) |
| 41 | 26. Supply & Fixingof one No. PVC insulated PVC sheathed weatherproof flat Aluminium conductor cable of size 2x6 Sq. mm on the surface for connection to compound light and gate light etc.as required. |
| 42 | 27. Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.(a). 2x10 sq mm |
| 43 | (b). 4 x16 sqmm |
| 44 | {c}. 3.5x25 sq m |
| 45 | SUB HEAD-II (Earthing) 1. Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 46 | 2. Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required |
| 47 | 3. Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 48 | SUB HEAD-III ( Air Conditioning Work) 1. ITC of 1.5TR split air conditioner unit including fixing of indoor and outdoor units and copper pipe laying of standard length with wraping the insulation on copper pipe, drainage piping i/c power connection etc complete as required. |
| 49 | 2. Transportation of two nos 1.5TR split Ac units alongwith indoor unit, outdoor unit installation kitfrom main T E Gonda to T. E Kotwa sadak in Barabanki SSA etc complete as required |
| 50 | 3. Supplying and fixing of powder coated M.S. wall /floor mounted stand for mounting of the outdoor unit i/c grouting with fastners etc complete as reqd. |
| 51 | 4. S/Laying of following items/ accessories of 1.5 TR SAC unit i/c brazing, bending, connections etc complete as reqd.(a). 1/2\" dia copper refrigerant pipe |
| 52 | (b). 1/4\" dia copper refrigerant pipe |
| 53 | {c}. 3x2.5 sq mm copper AC lead |
| 54 | 5. SITC of 4 KVA Single phase 50 Hz automatic voltage stablizer suitable for input voltage range 140- 280 Volts and output voltage 220 volts +/- 10% with high/low cutoff device with visual insication i/c all accessories and connection testingetc. Complete as required. |
| 55 | SUB HEAD-IV ( AFD system) 1. S.I.T.C. of 4 Zone solid state microprocessor based Main A.F.D. panelsuitable for working on 240 V AC supply/24 V DC supply and fabricated with16swg CRCA steel sheet with louvers for ventilation, in corporating audio visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities, provision of space for 2 Nos. suitable size battery, Battery charger trickle cum boost to take complete load of fire alarm i/c S/Fixing of 2 Nos. sealed maintenance free batteries 12 V, 7AH etc as required. (M/s Agni or any BSNL approved Make) |
| 56 | 2. Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600 / 1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 57 | 3. Supplying & laying of 3x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 58 | 4. Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 59 | 5. Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 60 | 6. Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 61 | 7. Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 62 | 8. Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 63 | 9. S/F of 4.5 Kg co2 type fire extinguishers with hose of suitable length i/c first charge etc. complete as reqd. ( BSNL approved make) |