Special Repair To Bldg No P 02 And Tr 04 Otm Of Sata Bty Under Ge North Akhnoor, Akhnoor-Jammu And Kashmir

Military Engineer Services-MES has published Special Repair To Bldg No P 02 And Tr 04 Otm Of Sata Bty Under Ge North Akhnoor. Submission Date for this Tender is 07-07-2021. Building Repair Tenders in Akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

28150787
Corrigendum : Special Repair To Bldg No P 02 And Tr 04 Otm Of Sata Bty Under Ge North Akhnoor
Open Tender
Indian
Jammu And Kashmir
Akhnoor
07-07-2021

Tender Details

Special Repair To Bldg No P 02 And Tr 04 Otm Of Sata Bty Under Ge North Akhnoor

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Jun-2021 Amendment to BOQ BOQ 30-06-2021
2 30-Jun-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-07-2021

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work : SPL REPAIR TO BLDG NO P-02 AND TR-04 (OTM) OF SATA BTY UNDER GE(N) AKHNOOR.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Dismantling of AC corrugated or semi-corrugated in roof covering including ridges, hips, valleys and flashings etc complete all as specified and as directed by Engineer-in-Charge. 120 Sqm
2 2 Dismantling timber scantlings (Framed work) 40 Sqcm and over in section, in any position complete all as specified. 2 Cum
3 3 M&L plain cement concrete type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in bed block, plinth courses, apex stones etc complete all as specified. 0.5 Cum
4 4 S&F structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified. 1500 Kg
5 5 S&F pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specifiedd.\n 120 Sqm
6 6 Ditto all as per item No 5 here-in-before but plain sheets 10 Sqm
7 7 Demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer -in-Charge 8 Cum
8 8 Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and as directed by Engineer -in-Charge 5 Cum
9 9 -Ditto- all as per Srl item No. 8 here-in-before, but except bricks. 3 Cum
10 10 Demolition of cement concrete (reinforced) in any description and any position otherwise described for (reinforcement cut as reqd to facilitate to demolition) complete all as specified and as directed.\n 2 Cum
11 11 Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,\nlintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and\nbeams, etc. complete all as specified and directed. 80 Sqm
12 12 M&L Reinforced Cement concrete (Designl mix) M-25 using 20 mm graded stone aggregate as in beams, cantilevers, lintels over 1.5m span, lintel bends etc complete all as specified and as directed. 5 Cum
13 13 TMT steel bars 10mm dia and over, cut to length bent to shape required including cranking bending etc and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. 500 Kg
14 14 ditto- all as per item No 13 above but 5mm dia and over upto and incl 10mm dia as in stirrups 150 Kg
15 15 Taking down cement plaster on brick or stone walls & ceiling surfaces etc including raking out joints hacking for key scrubbing down with water etc., complete all as specified and directed. 800 Sqm
16 16 Rendering 10 mm thick in cement and sand mortar 1:6 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and as directed. 300 Sqm
17 17 M&L 15mm thick plastering on other than fair faces of bricks or concrete surfaces finished even and smooth w/o using extra cement in CM1:4, mixed with water proofing compound @ 3% by weight of cement, complete all as specified and directed.\n(Note:- Water proofing compound shall be measured and paid separately). 400 Sqm
18 18 Supply only Integral water proofing compound, complete all as specified and directed. 110 Kg
19 19 Rendering 5 mm thick in cement and sand mortar 1:4 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified and as directed. 100 Sqm
20 20 Fixing 10mm outer dia PVC nozzles by drilling 1/3rd depth of the slab / sunken floor and injection grouting using Dr Fix IT URP 301 of M/s Pidilite Industries or equivlent as in sunken floor/roof slab all as specified and directed as per manufacturers instruction. 30 Each
21 21 Applying two coats of Dr Fix IT fast flex 113 ( coverage area 0.50 Sqm per Kg for two coats) of M/s Pidilite Industries or equivlent as in floor/wall all as per manufacturer's instruction. 200 Sqm
22 22 Taking down old treatment incl padding, removing existing bitumen felt treatment incl brushing cleaning top surface of roof slab by brooming etc., complete all as specified and directed. 30 Sqm
23 23 M&L for rendering 10mm thick cement plaster with cement mortar (1:4) on roof slab, complete all as specified and directed. 30 Sqm
24 24 Roof treatment :- \n(a) Apply a coat of biruminous primer conforming to IS - 3384 @ 0.40 Kg/Sqm on prepared surfaces. (b) After drying of primer apply a coat of hot blown 85/25 penetration grade blown bitumen conforming to IS-702 @ 1.20 Kg/Sqm of surfaces. \n(c) Provide APP modified polymeric five layred membrane with central core of 100 micron high molecular high density film. Minimum width of APP modified water proofing membrane shall be 3 Kg per Sqm. Product Name Multi plus manufactured by M/S STP texa Ltd Gurgoan/Hyper Plus Standard Manufactured by IWL India ltd Chennai, Bengal Acquaflux manufactured by Bengal bitumen New Delhi/Superior plus 310 by STP Lfd and any other product as appproved by E-in-C Br will be used. APP membranne will be laid across the slope from lowest line of slopping roof toward ridge with minimum end lap of 150mm and side lap of 75mm bonded with hot blown. (d) Over the APP membrane apply semi hot blown 85/25 grade bitumen penetration of bitumen when tested as per IS 1203 will not be more than 40/Confiming to IS 702 @ 1.20 Kg/Sqm and blended with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bitumen coat. (e) After providing above treatment provide two coats of aluminium paint as per manufacturing instruction. \n(f) Coved fillet in PCC (1:2:4) type B0 radius 75mm shall be provided at the junction of roof and vertical surface such as parapet wall around opening and treatment mentioned above (except fine sand) shall be applied followed by a cement plaster 20mm thick in CM 1:6. 30 Sqm
25 25 Complete removal of existing treatment on walls all as specified. 1000 Sqm
26 26 Preparation of old ( removal of existing treatment shall be paid under item No 25 above ) & new plastered surfaces and applying two coats of OBD over 3mm thick wall care putty all as specified and as directed. 1300 Sqm
27 27 Preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. 100 Sqm
28 28 Preparing of new plastered surface and applying two coats cement base paints over a coat of cement primer on walls, complete all as specified and directed. 400 Sqm
29 29 Preparation of old treated surfaces of walls (plastered or unplastered) and applying two coats of Apex exterior emulsion paint over a coat of primer as in roof projection / chajjas or pillar projections complete all as specified and directed. 50 Sqm
30 30 Dismantling of ceiling boards of any type and any thickness including cover fillets/GI grid framework complete all as specified and directed by Engineer-in-Charge. 240 Sqm
31 31 S&F of 8mm thick gypsum board false ceiling decorative vinyl lamination tiles (595x595mm) with aluminum foil backing for thermal insulation over GI snap grid frame work (Grid size 600x600mm) with powder coated GI angle of size (25x25x3) mm, main runner 'T' of size (25x40x3) mm , secondary runner 'T' of size (25x30x3) mm suspended with 3mm GI wire @ 1200mm c/c complete all as specified. 240 Sqm
32 32 Dismantling floor hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. 260 Sqm
33 33 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust , etc all as specified and directed. 300 Sqm
34 34 Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed.\n 15 Cum
35 35 Providing cement concrete type C-1, 1:3:6 ( using 20mm graded stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight), complete all as specified and directed. 180 Sqm
36 36 M&L cement concrete type B1 1:2:4 using 20mm graded stone aggregate 25mm thick as in flooring levelling course etc., complete all as specified and directed. 310 Sqm
37 37 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20mm thick screed bed in cement and sand mortar 1:3 complete all as specified and as directed by Engineer-in-Charge. 750 Sqm
38 38 Ditto all as per item No 37 here-in-before but in skirting/dado but with 10 mm thick backing plaster in CM (1:3) complete. 100 Sqm
39 39 20 mm thick makrana white marble as in border/cooking platform etc, bedded and jointed in cement mortar 1:6 of 20mm thick including pointing in white cement 1:2 using marble dust including cutting and polishing complete all as specified and as directed by Engineer-in-Charge. 40 Sqm
40 40 M & L Non skid coloured ceramic tiles 7mm to 8mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces incl 10mm thick screed bed/bedding layers in cement and sand mortar 1:4, complete all as specified and directed. 60 Sqm
41 41 M & L Glazed ceramic tiles coloured in vertical surfaces of size 450x350x7mm thick, jointing in neat cement slurry and pointing in colour cement to match including incl 10mm thick backing plaster in cement and sand mortar 1:3, complete all as specified and directed. 200 Sqm
42 42 S & F GI water tubes 15mm bore dia medium grade galvanised (ISI Marked) with all fittings and fixed complete to walls and ceiling or laid in floor including taking down existing water tubing, all as specified and directed 60 Rm
43 43 S & F GI water tubes 20mm bore dia medium grade galvanised (ISI Marked) with all fittings and fixed complete to walls and ceiling or laid in floor including taking down existing water tubing, all as specified and directed 30 Rm
44 44 Vitreous China squatting pan “Orissa pattern” size 580x440mm white incl provision of lime concrete bedding fixed in repairs, complete all as specified. 12 Each
45 45 PVC low level flushing cistern, valveless, syphonic action type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 90 cm long etc, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. 12 Each
46 46 Vitreous china oval counter wash basin (560x470mm), white, incl CP bottle trap, fixed in repairs complete all as specified. 8 Each
47 47 Stop valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15 mm, supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge 4 Each
48 48 Stop valves cast copper, screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 20 mm, supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge 8 Each
49 49 Stop valves/angle valve, cast copper alloy, chromium plated fancy type screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions, for bore dia of pipe 15 mm, supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge 35 Each
50 50 Bib taps, cast copper alloy (chromium plated, fancy type) with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, for bore dia of pipe 15mm, supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge. 20 Each
51 51 Pillar taps cast copper alloy, fancy type with capstan head, CP, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut, screwed for iron pipe 15 mm bore, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge. 8 Each
52 52 PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge. 35 Each
53 53 600mm x 450mm beveled edge mirror of selected quality glass, mounted on 6mm thick commercial quality ply-wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete supplied and fixed in repairs, all as specified and as directed by Engineer-in-Charge. 4 Each
54 54 Brass chromium plated tubular towel rail 20 mm dia, D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and as directed by Engineer-in-Charge. 4 Each
55 55 Stainless steel gratings 100mm bore size fixed with cement motar. 10 Each
56 56 S & F Rotational moulded polyethiene water storage tanks ISI marked of capacity 1000 litres (cylindrical vertical with closed top triple layered) hoisted and fixed in position including making necessary arrangement for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down of old existing tank, complete all as specified and directed by Enginieer-in-Charge. 4 Each
57 57 Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) complete all as specified and as directed by Engineer-in-Charge. 4 Each
58 58 S&F mild steel framed work as in grills, gratings ladders etc with ends of bar shouldered and/or riveted or welded or forged into spikes,framed guard bars,ladders,framework for watertanks and similar work conforming to Fe-290,grade E-165, complete all as specified 300 Kg
59 59 Taking down chowkats or frames n.exc 1..5 Sqm each with shutters (without taking off shutters from the frames) all as specifed and directed. 140 Each
60 60 Taking down chokhats or frames with shutters (without taking off shutters from frames) exceeding 1.5 Sqm but n.exc 4 Sqm each , complete all as specified and directed. 16 EACH
61 61 Pressed steel frames for doors of 1.25 mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, provding mild steel 6mm dia thresh hold bar and filling hollow of frame of sizes of frame 125 x 60mm, complete all as specified and directed. 40 RM
62 62 Pressed steel frames for doors of 1.25 mm thick sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, provding mild steel 6mm dia thresh hold bar and filling hollow of frame of sizes of frame 105 x 60mm, complete all as specified and directed. 40 RM
63 63 PCC 1:3:6 type C-0 using 12.5mm graded stone aggragate as in filling of pressed steel frame complete all as specified and directed. 0.5 Cum
64 64 PCC 1:3:6 type C-1 using 20mm graded stone aggregate for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and as directed by Engineer-in-Charge. 1 Cum
65 65 35mm thick factory made , IInd class hard wood plain, framed, panelled factory made shutters (two panel) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified & as directed by Engineer-in-Charge. 25 Sqm
66 66 35 mm thick factory made , 2nd class hard wood , glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified and as directed by Engineer-in-Charge. 20 Sqm
67 67 S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube supplying and fixing in opening as per specification and drawing. 80 RM
68 68 Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item in MES, schedule Part-II , 2004 as specified. 25 Sqm
69 69 S&F butt hinges 100 mm medium weight, cold rolled mild steel ISI marked, complete all as specified and directed. 60 Each
70 70 Aluminium alloy, anodised silding door bolt of length 300mm with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast aluminium extruded alloy and fixed, complete all as specified and directed.\n. 14 Each
71 71 S&F aluminium anodised barrel tower bolt 200 mm, extruded section, complete all as specified and directed. 80 Each
72 72 Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified. 80 Each
73 73 300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified and as directed by Engineer-in-Charge. 10 Each
74 74 S&F Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 . 90 Sqm
75 75 All as per item No 74 here-in-before but without glazing bars. 50 Sqm
76 76 S&F sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane 3mm thick, complete all as specified and directed. 80 Sqm
77 77 S&F for glavanised Mild steel wire cloth. 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvnaised wire staples, complete all as specified and directed. 70 Sqm
78 78 Applying two coat of synthetic enemal paint over & including a coat or red oxide zinc chrome primer over a new steel & iron surfaces of any description not otherwise described over 10cm in width or girth including prepartion of surfaces, complete all as specified and directed. 210 Sqm
79 79 Applying two coat of synthetic enemal paint to steel surfaces over factory coated a coat of red oxide primer of any description not otherwise described over 10cm in width or girth including prepartion of surfaces, complete all as specified and directed. 90 Sqm
80 80 Preparation of old painted steel surfaces of any description exc 10 cm width or girth, and applying two coats of synthetic enamel paint incl removal of old paint complete all as specified and directed. 100 Sqm
81 81 Preparation of new wooden surfaces of any description exc 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 75 Sqm
82 82 Dismantling of CI pipe of 50/75/100mm bore all as specified. 65 RM
83 83 S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. 20 RM
84 84 S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified. 15 RM
85 85 S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified. 20 RM
86 86 S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified. 10 RM
87 87 S&F 110mm PVC (SWR) bends any radius, provided with access door complete all as specified. 10 Each
88 88 S&F 75mm PVC (SWR) bends any radius, provided with access door complete all as specified. 10 Each
89 89 S&F 110mm PVC (SWR) 'P' trap all as specified. 12 Each
90 90 S&F 75mm PVC (SWR) floor trap, plain with grating incl jointing with solvant cement all as specified. 12 Each
91 91 Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; for laying Salt-glazed stoneware drain pipes, manholes, not exceeding 10 Sqm on plan and not exceeding 1.50 mtr in depth and getting out, in any type of soil, complete all as specified and as directed by Engineer-In-Charge. 67 Cum
92 92 Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore, set in cement mortar, complete all as specified and as directed by Engineer-In-Charge. 100 Rm
93 93 Plain cement concrete (1:3:6), type C-2 (using 40mm crushed stone aggregates) as in bed to drain pipes of 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-In-Charge. 100 Rm
94 94 Salt-glazed stoneware drain pipes, internal dia 150 mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-In-Charge. 100 Rm
95 95 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed by Engineer-In-Charge. 49 Cum
96 96 Removing excavated materials/ soils, not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge. 18 Cum
97 97 Plain cement concrete (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge. 5 Cum
98 98 Pre-cast reinforced cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in manhole cover slabs and finishing the surface as per clause 4.11.16 and MES SSR-1991 Part-1 5 Cum
99 99 Plain cement concrete M-15 (1:2:4), type B-1, (using 20mm graded crushed stone aggregate), nominal mix, as in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work, complete all as specified and as directed by Engineer-In-Charge. 1 Cum
100 100 Demolition of built-in cup board of particle/ wooden board of size (0.60 x 0.75 x 0.45 ) mt complete all as directed by Engr-in-charge. 80 Each
101 101 Taking down carefully copper/aluminium point wiring (light,fan , llight socket or power socket) complete, incluing fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per condition separately) and making good disturbed surfaces of wall, floor etc. 304 Per point
102 102 Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover plate as per numbers of switch modules for modular switches,sockets,fan regulators,red colour indicator, blank plates etc as approved coloures and including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- \n(Note:- All necessary accessories such as modular steel box,top cover plate, blank plate, screws,washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)\nMake of Cable Havells, KEI, Anchor \n\nOne light point controlled by one way switch 126 Per point
103 103 All as per srl item No 102 here-in-before but One fan point controlled by one switch and one regulator. 20 Per point
104 104 All as per srl item No 102 here-in-before but One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board . 99 Per point
105 105 All as per srl item No 102 here-in-before but One 5 pin 6 amps socket point controlled by one 6 amps switch on same board . 25 Per point
106 106 All as per srl item No 102 here-in-before but One light point controlled by two way switch. 2 Per point
107 107 M&L for concealed point wiring complete with 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) drawn into PVC conduit 20 mm dia, medium grade, ISI marked and fixed in concealed surface of wall,ceiling/false ceiling including cutting/chasing as required and its accessories, terminating in MS sunken box covered with and including 3 mm thick bakelite laminated sheet top cover "Hylam" and including 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and connected to earth dolly complete asll as pecifed and directed for\n\nOne 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board.\n\n( Note for ser No 4 & 5 - (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one RM). \n\n(b) Rate are inclusive cutting chases of bricks and making good to disturbed surfaces when ever required). \n\n(c) Proper colour coding should be adopted for phase, neutral and earth . 26 Per point
108 108 S & F modular type switch 6 amp 2 way, 1 module ,240V, ISI Marked complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor 4 Each
109 109 Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V, ISI Marked complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor 177 Each
110 110 Supply & fixing modular type switch 16 Amps, single pole,1way,1 module,240V, ISI Marked Complete all as specified and directed.Make : Indoasian glint, Crabtree, Anchor 18 Each
111 111 Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked Complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor 124 Each
112 112 Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module with light indication ,240V,AC ISI Marked Complete all as specified and directed . Make : Indoasian glint, Crabtree, Anchor 18 Each
113 113 Supply & fix fan regulator modular type electronic, stepped type(01 to 4/5), 100 to 120 Watts,240Volts,AC,ISI marked complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor 26 Each
114 114 Supply & fix angle lamp holder, insulated body with back plate for batten fittings including LED lamp 10 watts complete all as specified and directed. Make : Indoasian glint, Crabtree, Anchor 16 Each
115 115 Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed Make : Indoasian glint, Crabtree, Anchor 136 Each
116 116 Taking down unserviceable DBs and Supply and fixing in replacement of VTPN verticle loadline double door distribution box (DB) are fitted with Bus bar neutral link, blanking plates of 4 way with suitable for incomming MCCB 'I/C' frame \nMake -Indoasian part No- 811888 or its equivalent in Havells ,Legrand, L & T etc. 1 Each
117 117 Taking down unserviceable DBs and Supply and fixing in replacement of sheet metal enclosure double door type for DBs single pole and neutral 12 way 240 V with 200 Amp bus bar including blanking plates where required . \nMake : Indoasian, Legrand, Schiender, Havells etc. 4 Each
118 118 Taking down unserviceable DBs and Supply and fixing in replacement of sheet metal enclosure double door type for DBs single pole and neutral 6 way 240 V with 200 Amp bus bar including blanking plates where required . \nMake -Indoasian part No- 811806 or its equivalent in Havells ,Legrand, L & T etc. 1 Each
119 119 Supply and fix MCCB TPN 415 volts 16 KA, 63 Amp suitable for TPN vertical loadline DB mentioned at ser No 17 here in before. \nMake : Indoasian, Legrand, Schiender, Havells etc. 1 Each
120 120 Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed \nMake -Indoasian part No- 811122 TO 811129 or its equivalent in Havells ,Legrand, L & T etc. 44 Each
121 121 Supply & fix MCB SPN 32 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed. \nMake -Indoasian part No- 811151 or its equivalent in Havells ,Legrand, L & T etc. 9 Each
122 122 Taking down unserviceable Sub main wiring and M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade with all connected accessories such as Bend, Tee, Elbow, Short peices etc concealed in wall / roofs / floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLS type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Make of Cables Havells, KEI,Anchor\nNote : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. 200 RM
123 123 Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmx 600mmx 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45x 45x 45 CM,RCC cover 1:2:4 type B1 of size 45x45x6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. \n\nNote : 1. On testing , after completion , if the earth resistance equal or less 2 ohms is not obtained , earthing will be regenerated at no extra cost till the desired earth resistance is obtained. 2 Each
124 124 S& F in replacement of Energy saving 10 Watt LED Bulk head luminaries, 230V, 50Hz with oval shape, surface mounted, comprising high brightness LEDs complete all as specifed and directed. \nMake- Havells, Cat part No RUGBYNEONFT10WLED760SSYMBOPC or its equivalent in Bajaj, Philips, Crompton Greaves etc. 4 Each
125 125 Taking down UNSV flourescent fitting and M & L for LED batten Regal suitable for T8 LED tube incl T8 LED tube crystal glass with very high efficacy suitable for installation in existing T8 fitting with G13 lamp 20Watt 4 ft white all as specified and directed. \nMake : Havells Part No for batten- REGALBATTENT8UPTO1X22W DSBSWH, \nCat Part No- LED Tube T8 : CRYSTAL1213T8DSTL18WLED865SGLASS or equivalent in CG, Philips, Bajaj etc. Note :- Rate quoted include the cost of both batten and Tube rod T8 and shall match with the batten in. 96 Each
126 126 Taking down the existing ceiling fan and hanging the same and connecting upto including provision of cable from ceiling rose or connector to fan. 26 Each
127 127 Taking down old unserviceable Exhaust fan of any type/size from existing location and deposit in MES store yard and Supply and fix exhaust fan single phase metal body, AC 230 Volt, 50 Hz of size 300mm sweep with louvers shouter complete with all accessories including connecting up from ceiling rose to motor all as specified and directed. Make : Havells,Halonik, Bajaj, Usha etc 4 Each
128 128 S & F in replacement of 20 Watt LED energy saving light fitting environment friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 with GI bracket made of light grade GI pipe 40 mm dia of 1.2 mtr long bend to shape with 02 Nos of FI clamp 32 x 4mm with suitable size nuts, bolts, washers etc. and making the connection from ceiling rose to fitting with suitable size twin core copper conductor cable complete all as specified and directed . \n(Make- Havells, cat part No ENDURAPEARLSL20WLED757SASYTOPCMP or Bajaj/Philips/Crompton Greaves or its equivalent). 6 Each
129 129 Taking down unserviceable DBs and Supply and fix in replacement of Single pole and netural enclosure with two pin and earth plug and socket with one single pole MCB of capacity 20 namp 240 volts and connecting electrically including taking down unserviceable MCB complete all as specified.\nMake : Indoasian, Legrand, Schiender, Havells etc. 8 Each
130 130 Supply and lay XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 35 sqmm 3.5 core all as specified and directed. 60 RM
131 131 Supply and lay XLPE Insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross sectional area 10 sqmm 2 core all as specified and directed. 40 RM
132 132 S & F GI pipe light grade 50 mm bore for cable protection fixed on poles or laid in trenches under floor, ducts etc with fixing clamps, nuts , bolts etc. all as specified. 12 RM
133 133 Supply and lay sub class "B" burnt bricks, as in cable protection, laid length of brick perpendicular to length of cable, complete all as specified and as directed by Engineer-in-Charge. 0.567 Per 1000 Nos
134 134 M&L sand cushioning in trenches using clean dry river sand for cable cushioning, complete all as specified and as directed by Engineer-in-Charge. Note : Thickness of sand cushioning after punning down will be measured and paid. 5.52 Cum
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail